Instruction Manual for MONOGRAM models including: ZV950, 36-Inch Stainless Steel Vent Hood
GE Monogram
Monogram Monogram 36" Wall-Mounted Vent Hood - Slyman Bros
File Info : application/pdf, 12 Pages, 154.50KB
DocumentDocumentINSTALLATION INSTRUCTIONS 36" Stainless Steel Vent Hood ZV950 MONOGRAM.COM Safety Information BEFORE YOU BEGIN Read these instructions completely and carefully. IMPORTANT -- Save these instructions for local inspector's use. IMPORTANT -- Observe all governing codes and ordinances. N ote to Installer -- Be sure to leave these instructions with the Consumer. N ote to Consumer -- Keep these instructions with your Owner's Manual for future reference. S kill Level -- Installation of this appliance requires basic mechanical and electrical skills. C ompletion Time -- 1 to 3 Hours. 3URSHULQVWDOODWLRQLVWKHUHVSRQVLELOLW\RIWKH LQVWDOOHU3URGXFWIDLOXUHGXHWRLPSURSHULQVWDOODWLRQ is not covered under the warranty. )RU0RQRJUDPORFDOVHUYLFHLQ\RXUDUHDYLVLW monogram.com. ) RU0RQRJUDPVHUYLFHLQ&DQDGDYLVLWmonogram.ca )RU0RQRJUDP3DUWVDQG$FFHVVRULHVYLVLW monogram.com/use-and-care/parts. CAUTION Due to the weight and size of these vent hoods and to reduce the risk of personal injury RUGDPDJHWRWKHSURGXFW TWO PEOPLE ARE REQUIRED FOR PROPER INSTALLATION. ATTENTION À cause du poids et de la taille de ces hottes et pour reduire le risque de blessures et de GRPPDJHV IL FAUT DEUX PERSONNES POUR FAIRE L'INSTALLATION CORRECTEMENT. WARNING To reduce the risk of fire or electrical VKRFNGRQRWXVHWKLVUDQJHKRRGZLWKDQ\H[WHUQDO VROLGVWDWHVSHHGFRQWUROGHYLFH$Q\VXFKDOWHUDWLRQ from original factory wiring could result in damage to the unit and/or create an electrical safety hazard. AVERTISSEMENT 3RXUUpGXLUHOHULVTXHG¶LQFHQGLH RXGHFKRFpOHFWULTXHLOQHIDXWSDVXWLOLVHUFHWWHKRWWH DYHFXQUpJXODWHXUGHYLWHVVHpOHFWURQLTXHH[WHUQH7RXWH modification de ce type du branchement d'usine peute HQGRPPDJHUO¶DSSDUHLORXFUpHUXQULVTXHGHFKRFpOHFWULTXH TO REDUCE THE RISK OF FIRE, USE ONLY METAL DUCTWORK. WARNING 725('8&(7+(5,6.2)),5( (/(&75,&$/6+2&.25,1-85<723(56216 2%6(59(7+()2//2:,1* $ 8VHWKLVXQLWRQO\LQWKHPDQQHULQWHQGHGE\WKH PDQXIDFWXUHU,I\RXKDYHDQ\TXHVWLRQVFRQWDFW the manufacturer. % %HIRUHVHUYLFLQJRUFOHDQLQJWKHXQLWVZLWFKWKH power off at the service panel and lock the service disconnecting means to prevent the power from EHLQJVZLWFKHGRQDFFLGHQWDOO\:KHQWKHVHUYLFH GLVFRQQHFWLQJPHDQVFDQQRWEHORFNHGVHFXUHO\ IDVWHQDSURPLQHQWZDUQLQJGHYLFHVXFKDVDWDJ to the service panel. AVERTISSEMENT 32855e'8,5(/(5,648( '¶,1&(1',('(&+2&e/(&75,48(28'(%/(6685(6 ,/)$872%6(59(5/(65(*/(668,9$17(6 $ 8WLOLVH]FHWDSSDUHLOXQLTXHPHQWGHODPDQLpUpSUpYXHSDU OHIDEULFDQW(QFDVGHTXHVWLRQFRQVXOWH]OHIDEULFDQW % $YDQWWRXWHLQWHUYHQWLRQRXQHWWR\DJHFRXSH] O¶DOLPHQWDWLRQpOHFWULTXHDXGLVMRQFWHXUHWYHUURXLOOH]OH SDQQHDXGXGLVMRQFWHXUSRXUpYLWHUODPLVHVRXVWHQVLRQ accidentelle. S'il n'est pas possible de verrouiller le SDQQHDXGXGLVFRQFWHXUDWWDFKH]XQSODFDUGRXXQH pWLTXHWWHWUqVYLVLEOHDXSDQQHDX )RUJHQHUDOYHQWLODWLQJXVHRQO\'RQRWXVHWRH[KDXVW KD]DUGRXVRUH[SORVLYHPDWHULDOVRUYDSRUV 6WUXFWXUDOIUDPLQJLQVWDOODWLRQZRUNDQGHOHFWULFDO wiring must be done by qualified person(s). In accordance with all applicable codes and standards including fire-rated construction. 6XIILFLHQWDLULVQHHGHGIRUSURSHUFRPEXVWLRQDQG H[KDXVWLQJRIJDVHVWKURXJKWKHIOXHFKLPQH\RIIXHO EXUQLQJHTXLSPHQWWRSUHYHQWEDFNGUDIWLQJ)ROORZ the heating equipment manufacturer's guidelines DQGVDIHW\VWDQGDUGVVXFKDVWKRVHSXEOLVKHGE\ WKH1DWLRQDO)LUH3URWHFWLRQ$VVRFLDWLRQ1)3$WKH $PHULFDQ6RFLHW\IRU+HDWLQJ5HIULJHUDWLRQDQG$LU &RQGLWLRQLQJ(QJLQHHUV$6+5$(DQGWKHORFDOFRGH DXWKRULWLHV:KHQDSSOLFDEOHLQVWDOODQ\PDNHXS (replacement) air system in accordance with local building code requirements. / RFDOFRGHVYDU\,QVWDOODWLRQRIHOHFWULFDOFRQQHFWLRQV and grounding must comply with applicable codes. ,QWKHDEVHQFHRIORFDOFRGHVWKHYHQWVKRXOGEH LQVWDOOHGLQDFFRUGDQFHZLWK1DWLRQDO(OHFWULFDO&RGH $16,1)3$RUODWHVWHGLWLRQ CAUTION To reduce risk of fire and to properly H[KDXVWDLUEHVXUHWRGXFWDLURXWVLGH²GRQRWYHQW H[KDXVWDLULQWRVSDFHVZLWKLQZDOOVRUFHLOLQJVRULQWR DWWLFVFUDZOVSDFHVRUJDUDJHV ATTENTION Il faut prendre soin d'installer un conduit YHUVO¶H[WpULHXUSRXUUpGXLUHOHULVTXHG¶LQFHQGLHHWSRXYRLU pYDFXHUO¶DLUFRUUHFWHPHQW,OQHIDXWSDVpYDFXHUO¶DLUGDQV O¶HVSDFHHQWUHOHVSDURLVG¶XQPXUXQSODIRQGRXXQJUHQLHU un espace sanitaire ou un garage. READ AND SAVE THESE INSTRUCTIONS 2 31-2000900 Rev. 0 Design Information CONTENTS Design Information 3URGXFW'LPHQVLRQVDQG&OHDUDQFHV ........................ 34 2SWLRQDO$FFHVVRULHV..................................................... 4 Installation Preparation $GYDQFH3ODQQLQJ 'XFWZRUN)UDPLQJ ...................................................... 5 3RZHU6XSSO\ ................................................................ 5 'XFW)LWWLQJV................................................................... Tools and Materials Required........................................ 5HPRYHWKH3DFNDJLQJ ................................................. Check Installation Hardware.......................................... 'XFWZRUN:LULQJ/RFDWLRQV ........................................... Installation Instructions 6WHS,QVWDOO)UDPLQJIRU+RRG6XSSRUW ...................... 6WHS,QVWDOO0RXQWLQJ%UDFNHWV .................................. 6WHS,QVWDOO'XFW%UDFNHW ........................................... 6WHS,QVWDOOWKH+RRG ............................................... 6WHS&RQQHFW'XFWZRUN........................................... 6WHS&RQQHFW(OHFWULFDO ........................................... 11 6WHS,QVWDOO'XFW&RYHUV .......................................... 11 6WHS,QVWDOO)LOWHUV .................................................... 11 6WHS)LQDOL]H,QVWDOODWLRQ.......................................... 11 PRODUCT DIMENSIONS AND CLEARANCES 36" Vent Hood Installation Combinations This Stainless Steel Hood can be installed over any 0RQRJUDPFRRNWRSLQFOXGLQJWKH3URIHVVLRQDO UDQJHWRSDQGRUUDQJH &RRNLQJVXUIDFHWRERWWRPRIKRRGVKRXOGEH PD[IRUIWFHLOLQJKHLJKW WRIRUIWFHLOLQJKHLJKW PLQIRUIWFHLOLQJKHLJKW 3ODQWKHLQVWDOODWLRQKHLJKWFDUHIXOO\WRDYRLGXQVLJKWO\ gaps above the hood. *Height to Ceiling 10" 7KLVKRRGPXVWEHLQVWDOOHGPLQDERYHD0RQRJUDP 3URIHVVLRQDO&RRNWRSRU5DQJH&HLOLQJKHLJKWIRUWKLV LQVWDOODWLRQFRPELQDWLRQPXVWEHDWOHDVW KLJK NOTE: The supplied 2-piece duct cover is adjustable to ¿WIWWRIWFHLOLQJV)RUFHLOLQJKHLJKWVJUHDWHUWKDQ IWDQGXSWRIWRUGHU=;6'66VWDLQOHVVVWHHO duct cover accessory. 25" 35-5/8" 7KHVXSSOLHGGXFWFRYHU¿WVIWWRIWFHLOLQJV 7KHYHQWKRRGPXVWEHLQVWDOOHGPLQDQGPD[ DERYHWKHFRRNLQJVXUIDFH7KHKRRGLQVWDOODWLRQKHLJKW IURPWKHFRRNLQJVXUIDFHWRWKHERWWRPRIWKHKRRG depends upon ceiling height. ZV950SDSS Duct Cover Dimensions ZX14SDSS Duct Cover Dimensions Installation Height Depending on Ceiling Height 36" Min. 31-2000900 Rev. 0 3 Design Information PRODUCT DIMENSIONS AND CLEARANCES (Cont.) Using Duct Cover Accessories $'XFW&RYHU$FFHVVRU\PD\EHUHTXLUHGIRU\RXU hood installation height. Use this chart to determine installation height and accessory for your ceiling height. ZV950SDSS Installation Heights Actual Ceiling Height * Possible Hood Installation Height Duct Cover WR WR WR WR WR WR WR 6833/,(' WR WR WR WR WR WR WR WR WR WR PLQ PLQ PLQ PLQ PLQ PLQ =;6'66 PLQ %DVHGRQFRXQWHUWRSKHLJKW 7KHVHULDOSODWHLVORFDWHGEHKLQGWKHUHPRYDEOH¿OWHUV OPTIONAL ACCESSORIES Using Duct Cover Accessories =;6'66RSWLRQDOVWDLQOHVVVWHHOGXFWFRYHULV DYDLODEOHIRUFHLOLQJKHLJKWVJUHDWHUWKDQIWDQGXS to 14 ft. Order the optional duct cover at the same time as the vent hood and have on site before installation. This kit contains hardware required for installation. This kit contains installation hardware. NOTE: Duct covers must be installed as shown in this book. Do not "build-in" the duct cover. If service is UHTXLUHGWKHGXFWFRYHUPXVWEHUHPRYHGWRDFFHVV hood components. 4 31-2000900 Rev. 0 Installation Preparation ADVANCE PLANNING 'HWHUPLQHWKHH[DFWORFDWLRQRIWKHYHQWKRRG 3ODQWKHURXWHIRUYHQWLQJH[KDXVWWRWKHRXWGRRUV 8VHWKHVKRUWHVWDQGVWUDLJKWHVWGXFWURXWHSRVVLEOH)RU VDWLVIDFWRU\SHUIRUPDQFHGXFWUXQVKRXOGQRWH[FHHG IWHTXLYDOHQWOHQJWKIRUDQ\GXFWFRQILJXUDWLRQV 5HIHUWR³'XFW)LWWLQJV´FKDUWRQSDJHWRFRPSXWH WKHPD[LPXPSHUPLVVLEOHOHQJWKIRUGXFWUXQVWRWKH outdoors. :KHQDSSOLFDEOHLQVWDOODQ\PDNHXSUHSODFHPHQW air system in accordance with local building code requirements. Visit Monogram.com for available makeup air solutions. CAUTION To reduce risk of fire and to properly H[KDXVWDLUEHVXUHWRGXFWDLURXWVLGH²GRQRWYHQW H[KDXVWDLULQWRVSDFHVZLWKLQZDOOVRUFHLOLQJVRULQWR DWWLFVFUDZOVSDFHVRUJDUDJHV 8VHPHWDOGXFWZRUNRQO\7KHVHKRRGVPXVWXVH ´URXQGGXFW,WFDQWUDQVLWLRQWR´[´UHGXFLQJ WKHPD[LPXPHTXLYDOHQWGXFWOHQJWKWR IHHW ,QVWDOODZDOOFDSZLWKGDPSHURUURRIFDSDWWKH H[WHULRURSHQLQJ2UGHUWKHZDOORUURRIFDSDQGDQ\ transition needed in advance. Wall Framing for Adequate Support 7KLVYHQWKRRGLVKHDY\$GHTXDWHVWUXFWXUDOVXSSRUW must be provided. The hood must be secured to YHUWLFDOVWXGVLQWKHZDOORUWRDKRUL]RQWDOVXSSRUW 6HHSDJH :HVWURQJO\UHFRPPHQGWKDWWKHYHQWKRRGZLWKGXFW cover be on site before final framing and wall finishing. This will also help to accurately locate the ductwork and electrical service. ATTENTION Il faut prendre soin d'installer un conduit vers O¶H[WpULHXUSRXUUpGXLUHOHULVTXHG¶LQFHQGLHHWSRXYRLUpYDFXHU O¶DLUFRUUHFWHPHQW,OQHIDXWSDVpYDFXHUO¶DLUFRUUHFWHPHQW,OQH IDXWSDVpYDFXHUO¶DLUGDQVO¶HVSDFHHQWUHOHVSDURLVG¶XQPXUXQ SODIRQGRXXQJUHQLHUXQHVSDFHVDQLWDLUHRXXQJDUDJH POWER SUPPLY IMPORTANT (Please read carefully) WARNING )253(5621$/6$)(7<7+,6 $33/,$1&(0867%(3523(5/<*5281'(' AVERTISSEMENT 3285'(65$,6216'( 6e&85,7e&(7$33$5(,/'2,7Ç75(&255(&7(0(17 0,6¬/$7(55( Remove house fuse or open circuit breaker before beginning installation. 'RQRWXVHDQH[WHQVLRQFRUGRUDGDSWHUSOXJZLWKWKLV DSSOLDQFH)ROORZ1DWLRQDOHOHFWULFDOFRGHVRUSUHYDLOLQJ local codes and ordinances. Electrical supply 7KHVHYHQWKRRGVPXVWEHVXSSOLHGZLWK9+] DQGFRQQHFWHGWRDQLQGLYLGXDOSURSHUO\JURXQGHG EUDQFKFLUFXLWDQGSURWHFWHGE\DRUDPSFLUFXLW breaker or time delay fuse. :LULQJPXVWEHZLUHZLWKJURXQG ,IWKHHOHFWULFDOVXSSO\GRHVQRWPHHWWKHDERYH UHTXLUHPHQWVFDOODOLFHQVHGHOHFWULFLDQEHIRUH proceeding. 5RXWHKRXVHZLULQJWKURXJKFRQGXLWDVFORVHWRWKH LQVWDOODWLRQORFDWLRQDVSRVVLEOHLQWKHFHLOLQJRUEDFN wall. &RQQHFWWKHKRRGZLULQJWRWKHKRXVHZLULQJLQ accordance with local codes. Grounding instructions The grounding conductor must be connected to a JURXQGHGPHWDOSHUPDQHQWZLULQJV\VWHPRUDQ equipment-grounding terminal or lead on the hood. WARNING The improper connection of the equipment-grounding conductor can result in a risk of electric shock. Check with a qualified electrician or service representative if you are in doubt whether the appliance is properly grounded. AVERTISSEMENT Le mauvais branchement du fil de PLVHjODWHUUHSHXWFDXVHUXQFKRFpOHFWULTXH(QFDVGHGRXWH FRQVXOWHUXQpOHFWULFLHQTXDOLILpRXXQWHFKQLFLHQSRXUGpWHUPLQHU si l'appareil est à la terre. 31-2000900 Rev. 0 5 Installation Preparation DUCT FITTINGS This Hood Must Use an " Round Duct. It Can Transition to a 3-1/4" x 12" Duct. Equivalent Duct Piece Dimensions 5RXQGVWUDLJKW ´[´VWUDLJKW Equivalent Length* 1 ft. (per foot length) 1 ft. (per foot length) Quantity Used Total Equivalent Length 8VHWKLVFKDUWWRFRPSXWHPD[LPXP permissible lengths for duct runs to outdoors. NOTE:'RQRWH[FHHGPD[LPXP permissible equivalent lengths! HOERZ HOERZ IW IW Maximum duct length: 100 ft. for range hoods. »´[´ HOERZ 43 ft. Flexible ducting: ,IIOH[LEOHPHWDOGXFWLQJLVXVHGDOO the equivalent feet values in the WDEOHVKRXOGEHGRXEOHG7KHIOH[LEOH metal duct should be straight and VPRRWKDQGH[WHQGHGDVPXFKDV possible. '2127XVHIOH[LEOHSODVWLFGXFWLQJ NOTE:$Q\KRPHYHQWLODWLRQ V\VWHPVXFKDVDYHQWLODWLRQKRRG may interrupt the proper flow of FRPEXVWLRQDLUDQGH[KDXVWUHTXLUHG E\ILUHSODFHVJDVIXUQDFHVJDV water heaters and other naturally vented systems. To minimize the chance of interruption of such QDWXUDOO\YHQWHGV\VWHPVIROORZWKH heating equipment manufacturer's guidelines and safety standards VXFKDVWKRVHSXEOLVKHGE\1)3$ DQG$6+5$(:KHQDSSOLFDEOH install any makeup (replacement) air system in accordance with local building code requirements. Visit Monogram.com for available makeup air solutions. ´[´RU HOERZ IW ´[´ IODWHOERZ ´URXQGWR ´[´WUDQVLWLRQ ´[´WR´ round transition ´URXQGWR´[´ WUDQVLWLRQHOERZ IW 2 ft. 5 ft. IW ´[´WR´ 13 ft. URXQGWUDQVLWLRQHOERZ Round wall cap with damper 32 ft. ´[´ZDOOFDS with damper Round roof cap IW 44 ft $FWXDOOHQJWKRIVWUDLJKWGXFWSOXVGXFWILWWLQJHTXLYDOHQW(TXLYDOHQW length of duct pieces are based on actual tests conducted by *($SSOLDQFHV(YDOXDWLRQ(QJLQHHULQJDQGUHIOHFWUHTXLUHPHQWVIRU good venting performance with any ventilation hood. Total Duct Run 31-2000900 Rev. 0 Installation Preparation TOOLS AND MATERIALS REQUIRED (NOT SUPPLIED) 7DSHPHDVXUH 6DIHW\JODVVHV .QLIH 'XFWWDSH 6SLULWOHYHO 7DSHWRPRXQWWHPSODWH :LUHFXWWHUVWULSSHU *ORYHVWRSURWHFWDJDLQVWVKDUSHGJHV :LUHQXWV (OHFWULFGULOOZLWKDQGELWV 9+]RU$PSZLUHZLWKJURXQG3URSHUO\ grounded branch circuit 3KLOOLSVDQGIODWEODGHVFUHZGULYHUV 6WUDLQUHOLHIIRUMXQFWLRQFRYHU +DPPHU URXQGPHWDOGXFWOHQJWKWRVXLWLQVWDOODWLRQ 3OLHUV REMOVE THE PACKAGING The hood is shipped secured to a shipping board with (4) screws. Remove the 4 screws. Two screws are located at the top of the hood. Two are located at the bottom of the hood behind the grease filters. $VKLSSLQJEUDFNHWZKLFKVXSSRUWVWKHEORZHUPXVW DOVREHUHPRYHG,WLVVHFXUHGZLWKWZRVFUHZV$OOVFUHZ LPSUHVVLRQVDUH3KLOOLSV 5HPRYHDOOSDFNDJLQJWKHGXFWFRYHUVDQG accessories. /LIWWKHKRRGRXWRIWKHFDUWRQ 5HPRYHDQGSURSHUO\GLVFDUGDOOSODVWLFZUDSSLQJ Top Of Hood Remove Bottom Shipping Shipping Board Screws and Shipping Bracket 5HPRYHMXQFWLRQER[FRYHU ,QVWDOOVWUDLQUHOLHILQWRMXQFWLRQER[FRYHU Junction Top Shipping Screws Box 31-2000900 Rev. 0 Installation Preparation CHECK INSTALLATION HARDWARE /RFDWHWKHKDUGZDUHDFFHVVRU\ER[SDFNHGZLWKWKH hood and check contents. :RRG Screws :DOO )DVWHQHUV 2 Large )ODW:DVKHUV 2 Mounting Brackets with 4 +H[+HDG/HYHOLQJ6FUHZV 3KLOOLSV+HDG Decorative Screws 6WDLQOHVV6WHHO*UHDVH)LOWHUV 16" 24" 23" Duct Cover Bracket 11" 2-piece Decorative Duct Cover (dimension shown for reference only) 2-5/32" 13-9/16" · Drill 1/8" Pilot Holes For Mounting Brackets. CL 5-7/8" CL CL Align edge 25-1/2" above Cooking Surface. :DOO0RXQW7HPSODWH DUCTWORK, WIRING LOCATIONS 'HWHUPLQHWKHH[DFWORFDWLRQRIWKHYHQWKRRG /RFDWHWKHWHPSODWHSDFNHGZLWKWKHOLWHUDWXUH ±0 HDVXUHIURPWKHÀRRUWRWKHWRSRI WKHFRRNLQJVXUIDFH$GGRURWKHU recommended space) from the cooking surface to the bottom of the hood. Mark that location. Use a level to draw a straight pencil line on the wall. 6-1/4" Centerline To Wall FOR CEILING VENT DUCTING 8-1/2" Dia. Hole FOR WALL VENT DUCT · Drill 1/8" Pilot Holes For Mounting Brackets. 5-7/8" 2-5/32" Centerline 8" Min. Above Top Mounting Bracket Holes 17-1/2" CL Align edge 25-1/2" above Cooking Surface. Tape the template in position along the penciled OLQH&+(&.72%(685(7+(7(03/$7(,6 LEVEL. Ceiling ducting: ,IGXFWZRUNZLOOYHQWVWUDLJKWXSWRWKHFHLOLQJ 8VHDOHYHOWRGUDZDOLQHVWUDLJKWXSIURPWKH centerline on the template to the ceiling. 0HDVXUHIURPWKHEDFNZDOOWRWKH FHQWHUOLQHRIDKROHRQWKHFHLOLQJ NOTE: ,IGU\ZDOOLVQRWSUHVHQWDGGGU\ZDOO WKLFNQHVVWRWKHGLPHQVLRQ Wall Ducting: ,IGXFWZRUNZLOOYHQWWRWKHUHDU 8VHWKHOHYHOWRGUDZDOLQHVWUDLJKWXSIURPWKH centerline on the template. 0HDVXUHDWOHDVWDERYHWKHWRSPRXQWLQJ bracket holes shown on the template to the FHQWHUOLQHRIDQGLDGXFWKROH+ROHPD\EH elongated for duct elbow.) HOUSE WIRING LOCATION: 7KHMXQFWLRQER[LVORFDWHGRQWKHWRSRIWKHKRRG at the back right side. 5RXWHKRXVHZLULQJDVFORVHWRWKHFHLOLQJORFDWLRQ DVSRVVLEOHWKURXJKWKHFHLOLQJVRWRUEDFNZDOO :LULQJVKRXOGHQWHUDWOHDVWDERYHWKHEUDFNHW RQWKHULJKWVLGHQROHVVWKDQDERYHWKH SODQQHGORZHUHGJHRIKRRGDQGLGHDOO\WRWKH right of planned ductwork.) 31-2000900 Rev. 0 Installation Instructions 1 INSTALL FRAMING FOR HOOD SUPPORT IMPORTANT: Framing must be capable of supporting 100 lbs. 8" Min. Opening for Ductwork View From Rear Cleats 1" x 6" Min. Mounting Support 2 INSTALL MOUNTING BRACKET This vent hood must be secured to the horizontal support or wall studs. :LWKWKHWHPSODWHWDSHGLQSODFHXVHDSXQFKWR mark all mounting screw locations. 'ULOO´SLORWKROHVDWWKHSXQFKHGORFDWLRQV 5HPRYHWKHWHPSODWH 7KHVXSSRUWEUDFNHWKROHVPXVWHQWHUVWXGVRUWKH horizontal support. NOTE: 6FUHZV³$´DQG "B" are pre-assembled onto the brackets. Do not remove these screws. Screws "B" Screws "A" Centerline of Installation Space ,IGU\ZDOOLVSUHVHQWPDUNWKHVFUHZKROHORFDWLRQVIRU the top mounting brackets. Remove the template. &XWDZD\HQRXJKGU\ZDOOWRH[SRVHYHUWLFDOVWXGV at the bracket location indicated on the template. ,QVWDOODKRUL]RQWDOVXSSRUWDWOHDVW[EHWZHHQ two wall studs at the mounting screw location. The horizontal support must be flush with the room side of the studs. Use cleats behind both sides of the support to secure to wall studs. 5HLQVWDOOGU\ZDOO 6HFXUHWKHPRXQWLQJEUDFNHWVWRWKHZDOOVWXGVZLWK wood screws provided. 3 INSTALL DUCT BRACKET The duct bracket must be installed against the ceiling. This bracket will hold the decorative duct cover in place at the top. Install the 2 small screws into the sides of the duct EUDFNHW5HPRYHWKHVFUHZV3UHWDSSLQJWKHKROHV ZLOOLQVXUHHDVHRI¿QDOLQVWDOODWLRQ Pre-Tap Side Screw Pre-Tap Side Screw 31-2000900 Rev. 0 Secure the bracket to the ceiling and wall: 0DUNWKHVFUHZKROHORFDWLRQV 'ULOOSLORWKROHVLQPDUNHGEUDFNHWORFDWLRQ ,ISLORWKROHVGRQRWHQWHUVWXGVHQODUJHWKHKROHVWR DQGLQVWDOOZDOOIDVWHQHUDQFKRUV 'ULYHVFUHZVE\KDQGLQWRWKHIDVWHQHUVWRDOORZ DQFKRUVWRH[SDQG5HPRYHWKHVFUHZV 6HFXUHWKHEUDFNHWWRWKHFHLOLQJDQGZDOOZLWKZRRG screws and/or fasteners. Installation Instructions 4 INSTALL THE HOOD 3ODFHWKHKRRGRQWKHEUDFNHWVDQGVOLGHOHIWRUULJKWWR center. $GMXVWWKHLQVWDOODWLRQOHYHOQHVVE\WLJKWHQLQJ RUORRVHQLQJWKHVFUHZV³$´DWWKHERWWRPRIWKH brackets. 2. Mark the 2 lower mounting holes. 3. Remove the hood from the wall. 4. Drill a pilot hole in each lower mounting hole location. The two lower holes can be enlarged to LIWKH\GLGHQWHUVWXGV7DSDQFKRUVIRUZDOO fasteners into the bottom holes. Screws should be inserted by hand into the fasteners to allow anchors WRH[SDQGDJDLQVWWKHZDOOPDWHULDO5HPRYHWKH VFUHZVIRU¿QDOLQVWDOODWLRQ 5. Replace the hood on the mounting brackets. 8 VLQJWZRODUJHÀDWZDVKHUVVXSSOLHGLQVWDOOZRRG screws or wall fastener screws. 7LJKWHQVFUHZV³%´ORFDWHGDWWKHWRSRIWKH mounting bracket against the hood to clamp the position. Do not overtighten screws. Bracket Tabs Screws "B" 5 CONNECT DUCTWORK ,QVWDOOGXFWZRUNPDNLQJFRQQHFWLRQVLQGLUHFWLRQRI airflow as illustrated. 3XVKGXFWRYHUWKHH[KDXVWRXWOHWXQWLOLWUHDFKHVWKH duct stops. 6HFXUHMRLQWVLQGXFWZRUNZLWKVKHHWPHWDOVFUHZV :UDSDOOGXFWMRLQWVZLWKGXFWWDSHIRUDQDLUWLJKW seal. 8VHGXFWWDSHWRVHDOWKHIODQJHFRQQHFWLRQ CAUTION Do not use sheet metal screws at the hood flange connection. Doing so will prevent proper damper operations. Seal connection with tape only. ATTENTION Il ne faut pas utiliser de vis DXWRUDXUGHXVHVjODFRQQH[LRQGXFROOHWGHODKRWWH&HFL HPSrFKHUDLWOHERQIRQFWLRQQHPHQWGXUHJLVWUH1¶XWLOLVHU TXHGXUXEDQDGKpVLISRXUDVVXUHUO¶pWDQFKpLWpGXUDFFRUG Duct Tape Over Seam and Screw Air Flow Screw Duct Tape Over Flange Duct Stops Screws "A" 31-2000900 Rev. 0 Installation Instructions 6 CONNECT ELECTRICAL 9HULI\WKDWSRZHULVWXUQHGRDWWKHVRXUFH WARNING If house wiring is not 2-wire with DJURXQGZLUHDJURXQGPXVWEHSURYLGHGE\WKH LQVWDOOHU:KHQKRXVHZLULQJLVDOXPLQXPEHVXUH WRXVH8/DSSURYHGDQWLR[LGDQWFRPSRXQGDQG aluminum-to-copper connectors. AVERTISSEMENT Si la maison n'est pas câblee avec GHX[ILOVHWXQILOGHWHUUHO¶LQVWDOODWHXUGRLWLQVWDOOHUXQILOGH WHUUH4XDQGOHVILOVVRQWHQDOXPLQLXPLOIDXWSUHQGUHVRLQ d'utiliser des connecteurs aluminium à cuivre avec une pâte DQWLR[\GDQWHDSSURXYpHSDU8/ ,QVHUWKRXVHZLULQJWKURXJKVWUDLQUHOLHIDQGWLJKWHQ &RQQHFWZKLWHOHDGVWREUDQFKFLUFXLWZKLWHOHDG &RQQHFWEODFNOHDGVWREUDQFKFLUFXLWEODFNOHDG &RQQHFWJUHHQ\HOORZOHDGVWREUDQFKFLUFXLWJUHHQ lead or bare ground lead. 6HFXUHDOOFRQQHFWLRQVZLWKZLUHQXWVRQHDFK electrical connector. 3XVKZLUHVLQWRMXQFWLRQER[DQGUHSODFHFRYHU%H sure wires are not pinched. 8 CONNECT ELECTRICAL 5HPRYHSURWHFWLYHILOPRQWKHILOWHUV 7LSWKHILOWHULQWRWKHVORWVDWWKHUHDURIWKHRSHQLQJ Lift the filter and pull the knob forward until the filter rests on the slots. ,QVWDOODOOJUHDVHILOWHUV 7 INSTALL DUCT COVERS 3ODFHWKHGHFRUDWLYHMounting Screws duct covers on top of the hood. ,QVHUWWKHORZHU portion of the duct cover into the impressions on the top of the hood. ([WHQGWKHLQQHU duct upwards to the ceiling bracket. Bottom Notches 6HFXUHWKHGXFWFRYHUWRWKHEUDFNHWZLWKWKHVPDOO 3KLOOLSVVFUHZVSURYLGHG 7RUHPRYHWKHILOWHUVJUDVSWKHNQRESXVKWKHILOWHU towards the rear and tilt downwards. ,IWKH&OHDQ)LOWHU5HPLQGHULVJORZLQJUHGDIWHU ILOWHUVDUHLQVWDOOHGEHVXUHWRFKHFNWKHOHIWVLGH filter is making contact with the filter switch. 9 FINALIZE INSTALLATION 5HPRYHWKHSURWHFWLYHILOPFRYHULQJWKHFRQWURO SDQHORQWKHIURQWIDFHRIWKHKRRGDQGDQ\RWKHU packaging materials. 5HIHUWRWKH2ZQHU¶V0DQXDOIRURSHUDWLQJ instructions. 31-2000900 Rev. 0 11 NOTE::KLOHSHUIRUPLQJLQVWDOODWLRQVGHVFULEHGLQWKLVERRN safety glasses or goggles should be worn. )RU0RQRJUDP®ORFDOVHUYLFHLQ\RXUDUHDYLVLW monogram.com. NOTE:3URGXFWLPSURYHPHQWLVDFRQWLQXLQJHQGHDYRUDW 0RQRJUDP$SSOLDQFHV7KHUHIRUHPDWHULDOVDSSHDUDQFHDQG specifications are subject to change without notice. 31-2000900 Rev. 0 02-21 GEA Printed in Italy