Installation Instructions Model MOM2-XMP
MOM-2 Mounting Plate

INTRODUCTION INSTALLATION
COMPATIBILITY SPECIFICATIONS P/N 315-034822-3

The Model MOM2-XMP Mounting Plate from Siemens Industry, Inc., is used in CAB1, CAB2, CAB3 enclosures for mounting MOM-2 modules. A MOM2-XMP mounts in one position on a CAB-MP system mounting plate.
CAB-1 Enclosure is for indoor use only in dry environments.

Remove all system power before installation, first battery then AC. (To power up, connect the AC first, then the battery.)

Refer to Figure 1. There is a top and bottom to the MOM2-XMP Mounting Plate. The top end is the end with the longer (17/8") cutout.
1. With the top end of the MOM2-XMP facing up, place the MOM-2 on the plate with the terminal blocks (TB4/TB2) of the MOM-2 on the right side.

TOP OF MOM2-XMP
MOM-2
TB4 P4

2. Secure in place with two of the 10-32 screws

supplied in the upper and lower threaded holes

TB6

of the plate.

+

-

3. The MOM2-XMP can be installed in any one of

the four mounting positions on the CAB-MP,

however consideration should be given to wiring

requirements. If the terminal blocks of the

MOM-2 will be utilized, it is best to place the

MOM2-XMP in position 4 of the CAB-MP (See

Figure 2). 4. Secure the MOM2-XMP to the CAB-MP with

P2 TB2

two of the 10-32 screws in the top threaded

posts and two of the 10-32 screws in the bottom threaded posts of the CAB-MP.

Figure 1 Mounting The MOM-2 On The MOM2-XMP

The MOM2-XMP can be used in CAB1, CAB2, and CAB3 enclosures.

MOM2-XMP Mounting Plate: 4.75"W x 17"H
Siemens Industry, Inc. Building Technologies Division

firealarmresources.com

POSITION 1

POSITION 2

POSITION 3

POSITION 4

TOP
TOP THREADED POSTS
CAB-MP

BOTTOM THREADED POSTS

POSITION 1

POSITION 2

POSITION 3

POSITION 4

Figure 2 CAB-MP Mounting Positions

Siemens Industry, Inc. Building Technologies Division Florham Park, NJ

Siemens Building Technologies, Ltd. Fire Safety & Security Products 2 Kenview Boulevard Brampton, Ontario L6T 5E4 Canada
firealarmresources.com

P/N 315-034822-3



References