Installation Guide for MClimate models including: Vicki LoRaWAN, Target Temperature Control Device, Vicki LoRaWAN Target Temperature Control Device
Manual target temperature control Device operation You can set desired temperature directly from Vicki by rotating the device until you see the target temperature on the display. Low battery indication Child lock Callibration If Vicki's batteries are running low, she indicates that by showing a "Lo" message on the display.
Manual target temperature control Device operation You can set desired temperature directly from Vicki by rotating the device until you see the target temperature on the display. Low battery indication Child lock Callibration If Vicki's batteries are running low, she indicates that by showing a "Lo" message on the display.
Inside the box. Vicki. Vicki's backplate. User manual ... Supported LoRaWAN Features: OTAA, ADR, Adaptive Channels setup ... Energizer Lithium Ultimate L91.
File Info : application/pdf, 9 Pages, 1.33MB
DocumentDocumentInstallation guide Scan the QR Code to access Vicki LoRaWAN extended documentation mclimate.eu/lorawan-resources Bulgarian Vicki, QR . Dutch Om te weten te komen hoe u Vicki installeert, scan de QR-code of bezoek de link ernaast. Czech Chcete-li zjistit, jak nainstalovat Vicki, prohlédnte si kód QR nebo navstivte odkaz vedle nj. Hungarian A Vicki telepítésének kiderítéséhez keresse meg a QR-kódot, vagy keresse fel a mellette található linket. Finnish Tutustu Vicki-laitteen asentamiseen, skannaa QR-koodi tai vierailla sen vieressä olevassa linkissä. Irish Chun a fháil amach conas a shuiteáil Vicki, scanadh an cód QR nó tabhair cuairt ar an nasc in aice leis é. Danish For at finde ud af, hvordan du installerer Vicki, scan QR-koden eller besøg linket ud for det. French Pour savoir comment installer Vicki, scannez le code QR ou visitez le lien à côté de celui-ci. Italian Per installare Vicki scannerizzare il codice QR oppure aprire il link al suo lato. German Um herauszufinden, wie man Vicki installiert, scannen Sie den QR-Code oder besuchen Sie den Link daneben. Estonian Et teada saada, kuidas installida Vicki, QR-koodi või külastada linki kõrval. Swedish För att ta reda på hur du installerar Vicki, skanna QR-koden eller besök länken bredvid den. Latvian Lai uzzintu, k instalt Vicki, skent QR kodu vai apmekljiet saiti blakus tai. Portuguese Para saber como instalar Vicki, digitalize o código QR ou visite o link ao lado dele. Spanish Para saber cómo instalar Vicki, escanee el código QR o visite el enlace al lado. Maltese Biex issir taf kif jinstallaw Vicki, skennjati l-kodii QR jew ur il-link li jmiss lilu. Romanian Pentru a afla cum s instalai Vicki, scanai codul QR sau accesai link-ul de lâng acesta. Lithuanian Nordami suzinoti, kaip diegti Vicki, nuskaitykite QR kod arba apsilankykite nuorod salia jo. Slovak Ak chcete zisti, ako nainstalova Vicki, skenujte kód QR alebo navstívte odkaz veda nej. Polish Aby dowiedzie si, jak zainstalowa Vicki, zeskanuj kod QR lub odwied link obok niego. Russian , Vicki, QR- , . Greek Vicki, QR . Need some help? For more product information and issues related to it, visit: mclimate.eu/lorawan-resources or write us to: lorawan-support@mclimate.eu 00359 800 3 1010 Monday-Friday 09:00 - 18:00 Sofia, Bulgaria Aleksandar Malinov Boulevard 31, Campus X, Building 2, floor 1, office 1-2 Inside the box Vicki Vicki's backplate User manual Technical specifications Safety Instructions Compatibility Description: MClimate Vicki LoRaWAN - Smart Radiator Thermostat Developed & Manufactured by MClimateTM Model: MC-LW-V02 Dimensions: 54x78x50mm Weight: 107gr. Wireless technology: LoRaWAN® 1.0.3 LoRaWAN Security: LoRaWAN® End-to-End encryption (AES-CTR) LoRaWAN Device type: Class A End-device Supported LoRaWAN Features: OTAA, ADR, Adaptive Channels setup Supported LoRaWAN Regions: EU868 870 Link budget: 130dB RF Transmit power: 14dB Power supply: 3V (2 x AA batteries) Sensors: temperature and humidity Work temperature: 0° to +60° Material: ABS + Glass Environmental conditions, in which the device is intended to operate: - Indoor only; - Altitude up to 2000m; - Ambient temperature: 0° to +60°; - Maximum relative humidity of 80% for temperature up to 31°, decreasing linearly to 25% relative humidity at temperature of 50°; - Environment with contamination degree 2 (PD2). Storage and transportation conditions: - Ambient temperature :-40° to +85°; - Relative humidity 5% to 90% without condensation Manufacturer Melissa Climate Jsc Gen. Gurko 4 street 1000 Sofia,Bulgaria Compliance with the WEEE Directive The appliance marked with this symbol should not be disposed of with other household waste. It must be handed over to the relevant collection point for the recycling of electrical and electronic equipment. Please read the safety instructions before installing the device! Failure to follow the recommended instructions in this manual may be dangerous or in violation of the law. The manufacturer Melissa Climate Jsc., is not responsible for any loss or damage caused by failure to follow the instructions in the operating manual. Legal Notices All information, including but not limited to, features, functionality, and / or other product specifications are subject to change without notice. MClimate retains all rights to review or update its products, software or documentation without being required to notify any private or legal person. The MClimate and MClimate logo are trademarks of Melissa Climate Jsc. All other brands and product names mentioned herein are trademarks of their respective owners. EU Declaration of Conformity This device complies with the essential requirements and other applicable provisions of the following EU directives: Health: EN 62479:2010 2014/35/EU Low Voltage Directive: EN 60950-1:2006 / A11:2009 / A1:2010 / A12:2011 / A2:2013 2014/30/EU EMC Directive: EN 301 489-1 V2.1.1 EN 301 489-3 V2.1.1 Radio Equipment Directive (RED): EN 300 220-1 V3.1.1 EN 300 220-2 V3.1.1 You can find a copy of the Declaration of Conformity at: www.mclimate.eu/conformity Vicki works with the majority of radiator valves. Default radiator valve fitting: M30x1.5 Available adaptors: RA, RAV, RAVL, ORAS, Oventrop In order to operate Vicki, you will need: LoRaWAN network Batteries Battery type: 2xAA (1.5VDC each) Device operating voltage: 2.7 - 3.6VDC Batteries Follow the steps below to insert the batteries. 1 Unplug the backplate of Vicki. battery metal cover 2 Open the metal battery cover gently by using two fingers. 3 Insert 2xAA 1.5VDC batteries and fix the battery cover tightly in place. display 4 After successfully inserting the batteries and closing the metal battery plate, the device will display "Hi". Recommended batteries: Energizer Lithium Ultimate L91 Device does not operate with rechargeable batteries! Installation Remove the old thermostatic valve. thermostatic valve 32 1 Mount Vicki on the thermostatic valve 1 Set the old thermostatic valve to the highest setting (e.g. 5) 1 . 2 Unscrew the securing ring 2 and remove the thermostat. Warning: If you already have a thermostatic valve, during installation no water will leak. If you don't have a thermostatic valve, please call a specialist and ask them to replace your valves. 1 Place the backplate of Vicki on the thermostatic valve. 2 Screw tightly the securing ring. Do it by hand, no special instruments required. Do not overscrew. 4 Apply moderate pressure with your palm on Vicki's display and rotate the device clockwise to secure it on the backplate. 3 Insert Vicki on the backplate. display animation 5 After succesfully mounting of Vicki the front display must show the callibration animation. Installation 1 Open your LoRaWAN Network provider access panel and add the device using the supplied Serial Number, DevEUI, AppEUI (JoinEUI) and AppKey. 2 Continue the Installation with the instructions of your LoRaWAN Network provider. Device ID: 9X7621HS DevEUI: 70B3D25DD30009E1 AppEUI: 70B3D25DD3000000 AppKey: a0658dfae72131saf1249abc11 Register You can get DevEUI, AppEUI (JoinEUI) & AppKey information from the LoRaWAN credentials .csv file we sent you with the fulfillment confirmation. The data is example. Do not use. Device operation Manual target temperature control Low battery indication Child lock Callibration animation You can set desired temperature directly from Vicki by rotating the device until you see the target temperature on the display. If Vicki's batteries are running low, she indicates that by showing a "Lo" message on the display. If Child lock is activated, Vicki's display will show "Ch" and the manual temperature control will be disabled. Once you attach Vicki to the radiator, a calibration process will be initiated. The aim of the calibration process is to let Vicki know the kind of valve she is attached to. During calibration, the display will show a loading animation. Please, do not dismount the device during calibration! www.mclimate.eu Designed & Manufactured by MClimate in Europe.