User Manual for keemple models including: Single Touch Light Switch, KP-SW-07

KP-SW-07

USER MANUAL - Catalog of Certified Z-Wave Products

Touch switch is an in-wall switchgear based on Z-Wave wireless radio frequency technology for intelligent control. This product can be added to the gateway ...

USER MANUAL

keemple KP-SW-07

Manufacturer Manual


File Info : application/pdf, 1 Pages, 1.70MB

KP-SW-07user manual
Single Touch Light Switch
USER MANUAL
KP-SW-07 V1.0

1. Product Introducon
Touch switch is an in-wall switchgear based on Z-Wave wireless radio frequency technology for intelligent control. This product can be added to the gateway or PC controller supporng Z-Wave Plus, remotely controlled through the APP interface, or manually controlled by the touch. In addion, the product also supports the scene mode, the user can configure the scene through the APP, combine various devices in the same scene, and run the scene funcon through the APP or manually. KP-SW-07 is an intelligent touch switch that one touch switch buon can control one way output.
2. Package Contents
· 1x Wall Switch · 1x User Manual · 2x Screws
3. Product features
(1) Supporng touch control device switch state; (2) Supporng Smart Start; (3) Supporng S0 and S2 security network; (4) Supporng scene buon mode; (5) Z-Wave Plus cerfied for good compability (500 serials chipset); (6) Supporng LED light indicaon status: inclusion, exclusion, normal working status,
scene mode, etc. (7) Supporng repeater role; (8) Supporng firmware OTA

4. Product layout LED Indicator

Live Wire(input) Neutral Wire(input)

Output

Switch Buon

Scene Buon

5. Specificaons Power supply: Rated load current: Power consumpon: Nominal input voltage: Storage environment: Operaonal temperature: Wireless protocol: Wireless frequency:
Wireless Range:
Dimensions:

AC 110-240V, 50Hz 10A MAX 0.6W 230V -20~60 -10~45 Z-Wave 868.42MHz(EU) More than 100m outdoors About 40m indoors (depending on building materials) 85mm(L)*85mm(W)*32.5mm(H)

6. Installaon Steps
Note: Please disconnect the power before operaon Remark: Below blue wire is neutral wire (N).The red wire is live (L) For the KP-SW-07 Touch Switch, the household loads can only be connected to the L1 of the touch switch.

N

L

L1 L2

1) Screw off the screws of touch switch, then connect family wires of N and L to N and L wires of touch switch.

N

L

L1 L2

2) Screw on the screws.

N

L

L1 L2

3) Connect household loads to the L1 of touch switch.
N L L1

Note: In the state of electricity, do not directly touch the wiring part by hand. The maximum load current cannot exceed 10A, otherwise the touch switch will be damaged.

7. Buon and Indicator LED Funcon of Acon Buon:

Trigger

Descripon

Power on

When the load is open, the red light is on, and when the load is close, the blue light is on.

Short press once

Changing the status of Touch Switch's load. When the load is open, the red light is on, and when the load is close, the blue light is on.

Long press 1-5 seconds

Long press 1-5 seconds, the red light flashes slowly, and the previous indicaon state is restored aer release.

Long press 5-10 seconds

When the buon is pressed for 5-10 seconds, the pink light flashes slowly, and aer the release, the blue light flashes quickly. (Inclusion mode or Exclude mode)

Long press more than 20 seconds

Long press the buon for 20 seconds, the LED flashes slowly from red to pink color, and then LED will keep on for 3 seconds in pink, this procedure will reset Touch Switch to factory default.

Scene buon
Trigger
Short press for 1 me

Funconal descripon Send scene commands

LED status The red light is on for 3 seconds, then cut back to the default state (blue)

8. Security features of Smart Switch in Z-Wave network Touch Switch can be included and operated in any Z-Wave network with other Z-Wave cerfied devices from other manufacturers and/or other applicaons. All non-baery operated nodes within the network will act as repeaters regardless of vendor to increase reliability of the network. This device must be used in conjuncon with a Security Enabled Z-Wave Controller in order to fully ulize all implemented funcons.
Add for inclusion (non-security and security):
(1) Connect the power supply. (2) Set the Z-Wave network main controller into learning mode. (3) Press and hold the buon (the red light flashes slowly) unl the pink light flashes slowly
and then release, the device sends the network informaon (blue light flashes quickly). (4) Aer the network is successfully connected, the LED indicator of the device is steady
blue, and the load is off by default.
Add for inclusion (SmartStart): (1) Scan the QR code on your device, and add the device DSK to the main controller. (2) Power on Touch Switch, the LED indicator starts to flash slowly in blue and enters
SmartStart mode. (3) Aer the device accesses the network successfully, the device LED indicator is steady
blue and the load is off by default.
Note: SmartStart enabled products can be added into a Z-Wave network by scanning the Z-Wave QR Code present on the product with a controller providing SmartStart inclusion. No further acon is required and the SmartStart product will be added automacally within 10 minutes of being switched on in the network vicinity.

The node info frame supports (S2):

COMMAND_CLASS_ZWAVEPLUS _INFO

V2

COMMAND_CLASS_TRANSPORT_SERVICE

V2

COMMAND_CLASS_SUPERVISION

V1

COMMAND_CLASS_SECURITY

V1

COMMAND_CLASS_ SECURITY_2

V1

Security S2 Command Supported Report Frame:

COMMAND_CLASS_VERSION

V2

COMMAND_CLASS_SCENE_ACTUATOR_CONF

V1

COMMAND_CLASS_SCENE_ACTIVATION

V1

COMMAND_CLASS_ASSOCIATION_GRP_INFO

V1

COMMAND_CLASS_ASSOCIATION

V2

COMMAND_CLASS_POWERLEVEL

V1

COMMAND_CLASS_CENTRAL_SCENE

V3

COMMAND_CLASS_CONFIGURATION

V1

COMMAND_CLASS_FIRMWARE_UPDATE_MD

V4

COMMAND_CLASS_DEVICE_RESET_LOCALLY

V1

COMMAND_CLASS_SWITCH_BINARY

V1

COMMAND_CLASS_MANUFACTURER_SPECIFIC V2

9. Z-WAVE NETWORK EXCLUSION
Remove for exclusion: (1) Power on the switch. (2) Set the Z-Wave network controller into the exclusion mode. (3) Long press the switch buon(Red LED blink slowly) when Pink LED indicator light blink
slowly, release the buon, then the device start to send out exclusion informaon(Blue LED indicator in quick blinking). (4) When exclusion successfully, LED display is steady blue, load is off.

10. RESETTING SWITCH
Reset procedure will delete all informaon in the Z-Wave network or Z-Wave gateway, and will restore switch to factory default sengs. 1. Make sure switch is powered. 2. Touch and hold the Switch buon for 20 seconds. 3. Unl the pink light is always on, release the buon.
Note: Once the reset procedure is completed, Switch's relay will turn off. Use this procedure only in the event that the network primary controller is missing or otherwise inoperable.

11. Note for special command
ASSOCIATION Associaon command class allows Touch Switch to communicate with other Z-Wave devices directly. Group 1 is lifeline service that assigned to touch switch status. It enables
touch switch to send reports to Z-Wave Gateway whenever some buon is touched. This Group Support:

Grouping Idenfier Group 1 Group 2

Max Nodes 5 5

Send Commands
1. Switch Binary Report 2. Device Reset Locally Noficaon 3. Central Scene Noficaon 1. Scene Acvaon Set

Switch Binary Command Touch Switch offers a wide variety of advanced configuraon sengs. Below parameters can be accessed from main controllers configuraon interface.
Parameter No. 21 Seng device status aer power failure Define how the Switch reacts aer the power supply is back on.

0 ­ Touch Switch memorizes its state aer a power failure.

1 - Touch Switch does not memorize its state aer a power failure. Connected device will be on aer the power supply is reconnected. 2 - Touch Switch does not memorize its state aer a power failure. Connected device will be off aer the power supply is reconnected.
Default seng: 0 Parameter size: 1 [byte]
Parameter No. 24 Noficaon when Load status change Touch Switch can send noficaons to associaon device when state of Touch Switch's load change.
0 - The funcon is disabled. 1 - Send Switch binary report. 2 - Send Switch binary report only when Load condion is not changed by Z-WAVE Command.
Default seng: 1 Parameter size: 1 [byte]


Adobe PDF library 15.00 Adobe Illustrator(R) 17.0