DoorKing 6006 Gate Operator Quickstart Guide

For Gates Up To 18 Feet, 600 lbs - "Pull to Open" Installation

Brand: DoorKing

Model: 6006

Standard: UL 325 August 2018

This product is to be installed and serviced by a trained gate systems technician only. Visit www.dkslocator.com to find a professional installing and servicing dealer in your area.

"Pull to Open" Installation

This guide covers the "Pull to Open" installation for the DoorKing 6006 gate operator. The 6006 is intended for installation only on swing gates used for vehicles. Pedestrians must be supplied with a separate access opening.

Installation Measurements:

  • Ideal measurements: A = 7-3/4" (19.7 cm), B = 8-1/2" (21.6 cm).
  • Constraint: The sum of measurements A and B cannot be greater than 18" (45.7 cm).
  • Maximum opening angle: 110°.

Bracket Mounting:

  • Weld front and rear brackets directly to the gate and metal support post.
  • Alternatively, if mounting brackets with sleeve anchors to the gate and wall, weld reinforcing steel plates to the brackets.
  • Fully weld around entire brackets.
  • The rear bracket can be removed and fits in only one direction (refer to the full manual for details).
  • Actuator arm and brackets MUST be level!
  • A support bar must be installed the entire length of the gate to support the pickets.

Opening Direction DIP-Switch (SW 1):

The operator MUST OPEN the gate upon initial power-up and OPEN command.

  • If the operator closes the gate after an open command, shut off power and reverse the setting of SW 1, switch 1.
  • Incorrect settings will prevent the operator from functioning correctly.

Control Box:

Securely mount a control box near the actuator arm with appropriate hardware (not supplied).

Refer to your chosen 115 VAC or Solar powered control box manuals for complete DIP-switch settings.

Power Input:

Connect 115 VAC or Solar Power Input. Ensure power conduit and actuator cable are properly routed.

Limit Sensors Adjustment

Power to the circuit board must be ON when adjusting the limit sensors.

Procedure:

  1. Manually unlock the handle and rotate it 90° (see Manual Release section).
  2. Manually move the gate to the desired open or closed position.
  3. Loosen the set screw on the limit assembly and slowly slide the assembly.
  4. The "SLOW DOWN" LED will light first. Continue sliding until the corresponding "LIMIT" LED on the circuit board lights up.
  5. Tighten the set screw.
  6. Manually move the gate to the other position and repeat the process with the other limit assembly.

Note: The 3 and 5 limit LEDs can function as either Open or Close limits, depending on the DIP-switch SW 1, switch 1 setting.

Tools: Supplied 3/32" Hex Wrench for limit sensors.

Manual Release

To manually operate the gate:

  1. Unlock the handle with a key.
  2. Rotate the handle 90° in either direction to release the carriage, allowing manual movement of the gate.

Note: The handle can be rotated 180° and locked facing either side of the operator for easy key access.

Wiring to Circuit Board

For single operator installations, connect to the PRIMARY connection ONLY on the 115 VAC or Solar control box circuit board.

Note: If factory-wired jumpers are present on the operator terminal, they MUST be removed.

Wire Connections:

  • Wire 1 (Brown): MOTOR
  • Wire 2 (Blue): MOTOR
  • Wire 3 (Orange): LIMIT
  • Wire 4 (Red): SLOW DOWN
  • Wire 5 (Yellow): LIMIT
  • Wire 6 (Green): SLOW DOWN
  • Wire 7 (Green/Yellow): COMMON
  • Terminal 8: COMMON (Not Used for 7-wire operator cable)

Optional Accessories:

Coaxial Cable Antenna Kit P/N 1514-073 (Sold separately) can be used for improved signal range.

Photo Sensors Height

For optimal safety, photo sensors should be mounted:

  • Outside Property: 5" (12.7 cm) or less from the ground.
  • Inside Property: Typically around 21" (53 cm) from the ground.

The sensor should be mounted just below the actuator arm cable.

External Entrapment Protection Devices

Entrapment Protection must be provided for the gate system where the risk of entrapment or obstruction exists. The operator will not run without one or more monitored type B1 or B2 entrapment protection devices in EACH entrapment area.

Required Devices:

  • Only 1 monitored device can be connected for each cycling direction.
  • An OPTIONAL Expansion Kit (sold separately) will allow connection for additional devices.
  • Refer to your chosen 115 VAC or Solar powered control box manuals to wire entrapment protection devices.

Common Devices:

  • Reversing Edge: Mounted along the ENTIRE end of the gate.
  • Photo Sensor: Positioned to detect obstructions in the gate's path.

Note: DO NOT cycle the operator before limit sensors and DIP-switches have been adjusted, as damage could occur to the gate and operator.

Models: 6006 Swing Gate Actuator, 6006, Swing Gate Actuator

PDF preview unavailable. Download the PDF instead.

6006-066-F-2-21 Quickstart 11x17 Adobe InDesign CS6 (Macintosh) Adobe PDF Library 10.0.1

Related Documents

Preview DoorKing 6006 Vehicular Swing Gate Operator Installation and Options Manual
Comprehensive guide for the DoorKing 6006 Vehicular Swing Gate Operator, covering mounting, 4302 control box options, safety instructions, and UL 325 entrapment protection.
Preview DoorKing Model 6555 Heavy-Duty Vehicular Swing Gate Operator Installation and Owner's Manual
Comprehensive guide for the DoorKing Model 6555 Heavy-Duty Vehicular Swing Gate Operator, covering installation, adjustments, wiring, safety compliance (UL 325), operation, and maintenance for Class III and Class IV vehicular applications.
Preview DoorKing 6524-381 Solar Powered Vehicular Swing Gate Operator Installation/Owner's Manual
This manual provides comprehensive installation and owner's information for the DoorKing Model 6524-381 Solar Powered Vehicular Swing Gate Operator. It covers safety instructions, installation procedures, solar power connections, adjustments, wiring terminals, operating instructions, maintenance, troubleshooting, and owner responsibilities, ensuring safe and efficient operation.
Preview DoorKing 6524-380 Vehicular Swing Gate Operator Installation and Owner's Manual
This manual provides comprehensive installation, operation, and maintenance instructions for the DoorKing 6524-380 AC Powered Vehicular Swing Gate Operator. It covers safety guidelines, wiring, adjustments, and troubleshooting.
Preview DoorKing 9050 Vehicular Slide Gate Operator Installation Manual
Comprehensive installation and owner's manual for the DoorKing 9050 Vehicular Slide Gate Operator, detailing setup, safety features, and maintenance for UL 325 and ASTM F2200 compliance.
Preview DoorKing Vehicular Traffic Control Product Reference Guide
Comprehensive guide to DoorKing's range of vehicular traffic control systems, including gate operators, traffic spikes, and accessories. Features detailed specifications, model information, and safety guidelines.
Preview DoorKing 9024-380 AC Powered Vehicular Slide Gate Operator Installation and Owner's Manual
Comprehensive installation and owner's manual for the DoorKing 9024-380 AC Powered Vehicular Slide Gate Operator. Covers safety, installation, adjustments, entrapment protection, wiring, operation, maintenance, and troubleshooting.
Preview DoorKing 9024-381 Solar Powered Vehicular Slide Gate Operator Installation and Owner's Manual
Comprehensive manual for the DoorKing 9024-381 Solar Powered Vehicular Slide Gate Operator. Covers installation, solar power connections, adjustments, entrapment and safety protection, terminal wiring, operating instructions, maintenance, troubleshooting, and owner information. Compliant with UL 325 and ASTM F2200 standards.