Installation plan Heat-pump dryer PDR 908 HP Always read the operating and installation instructions before setting up, installing, and commissioning the machine. This prevents both personal injury and damage to the machine.
Aug 24, 2021 — Connection optional or required, depending on model. AL. Vented. KLZ. Cooling air intake. ASK. Condensate drain hose. PA. Potential equalization.
12 dic 2021 — Connection optional or required, depending on model. AL. Vented. KLZ. Cooling air intake. ASK. Condensate drain hose. PA. Potential equalization.
File Info : application/pdf, 10 Pages, 664.89KB
DocumentDocumentInstallation plan Heat-pump dryer PDR 908 HP Always read the operating and installation instructions before setting up, installing, and commissioning the machine. This prevents both personal injury and damage to the machine. en-CA 11 276 750/05 Please have the model and serial number of your machine available when contacting Technical Service. Canada Importer Miele Limited Professional Division 161 Four Valley Drive Vaughan, ON L4K 4V8 Phone: 1-888-325-3957 www.mieleprofessional.ca professional@miele.ca Miele Professional Technical Service Phone: 1-888-325-3957 serviceprofessional@miele.ca Manufacturer: Miele & Cie. KG Carl-Miele-Straße 29, 33332 Gütersloh, Germany Legend: Connection required AL ASK B EL F KG KGA KLA Vented Condensate drain hose Machine anchoring Electrical connection Machine feet, adjustable Payment system Payment system connection Cooling air vent 2 Connection optional or required, depending on model KLZ Cooling air intake PA Potential equalization SLA Peak-load connection APCL SST Closed base APCL OB Open base APCL 001 Washer-dryer stacking kit XKM Communication module ZL Air intake All rights reserved. 11 276 750/05 PDR 908 HP en-CA Machine dimensions * The distances between the machine and the wall are recommendations to help make it easier to carry out service work. If installation space is limited, the machine can also be pushed up against the wall. 11 276 750/05 3 PDR 908 HP en-CA Installation * The distances between the machine and the wall are recommendations to help make it easier to carry out service work. If installation space is limited, the machine can also be pushed up against the wall. 4 11 276 750/05 PDR 908 HP en-CA Washer-dryer stack * The distances between the machine and the wall are recommendations to help make it easier to carry out service work. If installation space is limited, the machine can also be pushed up against the wall. 11 276 750/05 5 PDR 908 HP en-CA Installation * The distances between the machine and the wall are recommendations to help make it easier to carry out service work. If installation space is limited, the machine can also be pushed up against the wall. 6 11 276 750/05 PDR 908 HP Technical data Drying system Drum volume Capacity Door opening diameter Electrical connection (EL) Standard voltage CDN & USA Frequency Total rated load Fuse rating Supply cable min. cross-section Supply cable with plug type NEMA L6-30P Length of supply cable Non-standard voltage MAR 208-240 (Marine) Frequency Total rated load Fuse rating Supply cable min. cross-section Supply cable with plug type NEMA L6-30P Length of supply cable Condensate drain hose (ASK) Max. drainage temperature Max. transient flow rate On-site hose sleeve for drain hose Drain hose (internal diameter) Length of drain hose Max. delivery head (from lower edge of machine) Potential equalization (PA) Machine connection (separate kit required) XCI box / XCI AD interface Peak load/energy management (SLA) Machine connection (with XCI box) Payment system connection (KGA) Connection of payment systems (with XCI box / XCI AD) Communication module (XKM) Communication module XKM 3200 WL PLT Installation on machine feet (F) No. of machine feet Machine foot, height-adjustable with thread Machine foot diameter Anchoring (B) Anchoring of Miele bases Miele base installation (fasteners included) Required anchor points Wood screws according to DIN 571 Rawl plugs (diameter x length) Base floor anchoring (to be provided on site) Machine installation on on-site base (concrete or masonry) Min. base installation footprint (W/D) Wood screws according to DIN 571 Rawl plugs (diameter x length) = standard, = optional, + = only on request, - not available 11 276 750/05 PDR 908 HP Heat pump l 130 (4.59 ft3) kg 8.0 (17.6 lb) mm 370 (17 9/16 in) 2 AC 208-240 V Hz 60 kW 1.2 A 2 x 30 3 x AWG10 mm 2,100 (6.9 ft) 2 AC 208-240 V Hz 60 kW 1.2 A 2 x 30 3 x AWG10 mm 2,100 (6.9 ft) °C l/min mm mm mm mm 70 (158°F) 3.6 (0.95 gal/min) 10 x 30 (3/8 x 1 3/16 in) 10 (DN10) 1,500 (4.9 ft) 1,000 (3.3 ft) No. 4 mm ± 5 (3/16 in) mm 31.7 (1 1/4 in) No. 4 mm 8 x 65 (5/16 x 2 9/16 in) mm 12 x 60 (1/2 x 2 3/8 in) mm 600/650 (23 5/8 x 25 9/16 in) mm 6 x 50 (1/4 x 2 in) mm 8 x 40 (5/16 x 1 9/16 in) en-CA 7 PDR 908 HP Technical data Machine data Overall machine dimensions (H/W/D) Casing dimensions (H/W/D) Site-access dimensions (H/W) Min. site-access opening (excl. packaging) Installation dimensions Side gap Recommended side gap washer-dryer stack Recommended distance to opposite wall from front of machine Weights and floor loads Machine weight (net weight) Max. floor load in operation Emissions Sound pressure level (in accordance with EN ISO 11204/11203) Heat dissipation rate to installation site PDR 908 HP mm 850/605/777 (33 7/16 / 23 13/16 / 30 9/16 in) mm 850/596/737 (33 7/16 / 23 7/16 / 29 in) mm 900/605 (35 7/16 / 23 13/16 in) mm 20 (13/16 in) mm 300 (11 13/16 in) mm 1,000 (39 3/8 in) kg 73 (161 lb) N 925 dB(A) <70 W 950 en-CA = standard, = optional, + = only on request, - not available 8 11 276 750/05 PDR 908 HP Installation and planning notes Installation requirements The tumble dryer should only be connected to a power supply provided in accordance with all appropriate local and national legislation and regulations. In addition, all regulations issued by the appropriate utilities as well as standards relating to occupational safety and all applicable valid regulations and technical standards must be observed. General operating conditions Ambient temperature in installation room: +2°C to +35°C (36°F to 95°F). Air drawn in for use in the drying process will be warm when it is expelled back into the room. You must therefore ensure that the room is sufficiently ventilated, particularly if the dryer is located in a small room. Make sure that the room temperature is not too high. If there are other heat-producing appliances in the room in which the dryer is located, make sure the room is well ventilated and switch the other appliances off, if possible. Otherwise running times and energy consumption could be increased. Electrical connection This tumble dryer is supplied with a power cord and plug ready for connection. The machine may only be connected to an electrical system that conforms to the national and local codes and regulations. The tumble dryer should never be connected by an extension cord, e.g. power strips, to avoid the risk of fire. The data plate indicates the nominal power consumption and the appropriate fuse rating. Compare the specifications on the data plate with those of the electrical power supply. If the machine is hard-wired, a dual circuit breaker must be provided on site. When switched off, there must be an all-pole contact gap of at least 3 mm in the isolator switch (including circuit breakers, breakers, and relays according to IEC/EN 60947). The plug connector or isolator switch should be easily accessible at all times. If the machine is disconnected from the electricity supply, the isolator must be lockable or the point of disconnection must be monitored at all times. New connections, modifications to the system, or servicing of the ground conductor, including determining the correct fuse amperage, must be carried out by a qualified electrician, as they are familiar with the pertinent regulations and the specific requirements of the electric utility company. References to cable cross-sections in the technical data refer only to the required power cord. Please consult relevant local and national regulations when calculating any other wire gauges. Condensate drain hose The condensed water is pumped away through the drain hose which is located at the back of the dryer. The condensate is drained via a drain pump with a 1 m (3.3 ft) delivery head. For the water to drain freely, the hose must be installed free of kinks. The swivel elbow at the end of the hose can be turned in either direction or removed as needed. In certain situations, this tumble dryer must be fitted with a non-return valve (optional accessory). Without a non-return valve, water could flow back into the tumble dryer or be drawn back in and leak out. This can cause damage. en-CA Drainage options: 1. Direct connection to a plastic drain pipe with a rubber sleeve. Use a non-return valve if the end of the hose could possibly become submerged in water. 2. Connection to a sink with a plastic nipple. Always use a non-return valve. 3. Connection to a floor drain (gully). Always use a non-return valve. 4. Directed into a sink or basin. Secure the drain hose carefully (e.g. by tying it) to make sure it cannot slip. Otherwise water may escape and cause damage. Use a non-return valve if the end of the hose could possibly become submerged in water. Potential equalization If necessary, potential equalization with good galvanic contact must be guaranteed in compliance with all applicable local and national installation specifications. Connection material for potential equalization must be provided on site or using a kit available from Miele Service. Peak load/Energy management The tumble dryer can be connected to a peak load or energy management system using an optional kit. When the peak-load function is activated, the heating is deactivated. A message appears in the display to inform you of this. Payment system The tumble dryer can be fitted with a single-machine payment system as an optional accessory using an optional kit (XCI box / XCI AD). The programming required for connecting a payment system can be carried out during the initial commissioning process. After initial commissioning, changes may only be carried out by your Miele dealer or Miele Service. Interface The tumble dryer can be retrofitted with an XKM 3200 WL PLT communication module. This module can be used as a WiFi or LAN interface. The LAN interface provided via the module complies with SELV (Safety Extra Low Voltage) in accordance with EN 60950. Connected appliances must also comply with SELV. The LAN connection uses a RJ45 connector in accordance with EIA/TIA 568-B. 11 276 750/05 9 PDR 908 HP Installation and anchoring The machine must be installed on a perfectly smooth, level and firm surface which is able to withstand the quoted loads. The floor load created by the machine is concentrated and transferred to the installation footprint via the machine feet. The tumble dryer should be levelled in both directions with the aid of the adjustable feet. Base installation The tumble dryer can be installed on a machine base (open or box base, available as an optional Miele accessory) or on a concrete base to be provided on site. The quality of the concrete and its strength must be assessed according to the machine load. Ensure that any raised concrete base is adequately bonded to the floor below. Washer-dryer stack The tumble dryer can be installed as a washer-dryer stack together with a Miele Washing Machine. A stacking kit (optional accessory) is required for this. Installation of the stacking kit must be performed by Miele Service or an authorized Miele service technician. en-CA 10 11 276 750/05