2 SSP 200 • Setup uide (Continued) Mounting and Cabling Step 1 — Mount the device a. Turn off or disconnect all equipment power sources. b. Mount the SSP 200 using optional rack and under-furniture mounting kits (available at www.extron.com), or place on a table using the provided rubber feet.
Media.extron.com
The Extron SSP 200 is a high-performance surround sound processor that automatically decodes Dolby , DTS , and PCM formats from digital input sources to ...
SSP 200 · Setup Guide GusoestrpoegwcupiwifdrIiwocMead.,etuiiPxnoctsntrOtostaonlbRl.atcehtoTfieoomArnpefoioNncwroseTttnhrrnu:esecocctuiotoirmncngesp.,lteahtneed The Extron SSP 200 is a high-performance surround sound processor that automatically decodes Dolby®, DTS®, and PCM formats from digital input sources to discrete audio outputs. Providing up to ten built-in balanced analog outputs, the SSP 200 provides the flexibility needed for pro A/V applications in corporate, commercial, and education environments. It supports the latest immersive formats of Dolby Atmos and DTS:X plus legacy Dolby and DTS formats. An upmix function synthesizes exceptional multichannel audioSOfrUoRmCEstereo content. The SSPIN2P0U0Tfeatures an HDMI inpuVtOwLiUthMEloop through, coaxial and optical digital inputs, and an analog stereo input. It is designed for integration into pro A/V installations, featuring a compact, half-rack 1 2 3 4 5 metal enclosure, RS-232 serial and LAANTMOcSontrol, and balanced line level outputs. This guide provCOidNFeIGs instructionPsCMfor aHDnCPexperienced user to set up and configure the SSP 200. It covers how to connect ocothnee firgdueravticioens and perform bas2i-cCHopeEXrPations using rear panel connections and the front panel controls. For full operation and through Extron Product Configuration Software (PCS), internal web paSUgReROsU,NDaSnOUdNDSSPSRiOmPCEp2SS0lOe0R Instruction Set (SISTM) commands, see the SSP 200 User Guide. A B C D NOTE: For information while using PCS, see the SSP 200 PCS Help File. E Rear Panel Connectors H INPUTS L R 1(LF) 2(RF) 3(C) 4(SUB) 5(LS) 6(RS) 7 8 9 (MIX) 10 100-240V --A MAX OUTS 50-60 Hz 5 1 THRU 2 3 4 DMP EXP RS-232 Tx Rx G LAN RESET SSP 200 A B Figure 1. Rear Panel Connectors C D E FG A AC power connector B Audio inputs C DMP expansion port D RS-232 port E LAN port F Reset button G Status light H Analog outputs The SSP 200 (A) uses an IEC power cable to connect to a 100-240 VAC, 50-60 Hz, power source. The SSP 200 (B) accepts one HDMI input with embedded audio, three digital inputs, and one analog input. In addition, there is an HDMI loop out (through) connector. · Input 1 accepts digital signals through an HDMI cable, supporting HDMI version 2.0 with HDCP version 2.3 compliance. · Input 2 accepts a 75 ohm unbalanced digital coaxial S/PDIF input. · Inputs 3 and 4 accept digital signals through S/PDIF optical (TOSLINK®) cables. · Input 5 accepts a balanced or unbalanced, stereo or mono, analog input through a 6-pole captive screw connector. Connect an EXP-enabled device to the DMP expansion port (C) for a digital audio connection using Extron proprietary protocol. Use the included one-foot long shielded CAT6 cable to connect the SSP 200 to a Primary EXP-enabled device (see the SSP 200 User Guide for EXP bus operation details). The ten outputs (H) are balanced or unbalanced, line level, analog signals made available through captive screw connectors providing outputs for the following surround sound channels. Number 1 2 3 4 5 Abbreviation LF RF C SUB LS Channel Description Left front Right front Center Subwoofer Left surround Number 6 7 8 9 10 Abbreviation Channel Description RS Right surround See note below See note below See note below See note below NOTE: Numbers 7 through 10 are configurable as back, height, or downmix channels using PCS. By default, the SSP 200 is set to 7.1 with downmix enabled with all ten analog outputs enabled. Outputs in this configuration are 7 Left Back, 8 Right Back, 9 Downmix Left, and 10 Downmix Right. 1 SSP 200 · Setup Guide (Continued) Mounting and Cabling Step 1 -- Mount the device a. Turn off or disconnect all equipment power sources. b. Mount the SSP 200 using optional rack and under-furniture mounting kits (available at www.extron.com), or place on a table using the provided rubber feet. The SSP 200 is housed in a 1U-high, 8.5 inch deep, half-rack wide enclosure. Step 2 -- Connect inputs Make the following input connections as needed (see figure 1, B, on the previous page): · Connect digital sources to Inputs 1 through 4 depending on connector type. · Connect balanced or unbalanced analog audio sources to Input 5 through the 6-pole input connector. Step 3 -- Connect outputs Make the following output connections as needed: · Connect balanced or unbalanced analog audio output devices to the captive screw output connector (H). Refer to Audio Wiring on the next page for more information. A representative application diagram is shown below. Ch. 1 & 2 Bridged Extron SF 10C SUB Subwoofer Extron XPA U 1004 Power Ampli er CLASS 2 WIRING 12 10 8 12 10 8 12 10 8 12 10 8 LIMITER/ 14 6 14 6 14 614 6 1 2 3 4 STANDBY 1 G 2 3 4 PROTECT 18 4 4 4 4 26 1 2 12 12 12 100-240V 1.0A, 50-60Hz 1 2 3 4 1 0 2 0 3 0 4 0 XPA U 1004 SIGNAL ATTENUATION INPUTS REMOTE 8/4 OUTPUTS LHF RHF LHB Extron SF 26CT Two-Way Ceiling Speakers STANDBY 100-240V --A MAX OUTS 100-240V 1.5A, 50-60 Hz Extron XPA 4002 Power Ampli er XPA 4002 GREEN - ACTIVE AMBER - STANDBY REMOTE G LIMITER/ PROTECT 12 SIGNAL ATTENUATION 1 2 12 10 8 12 10 8 14 6 14 6 18 4 18 4 26 2 26 2 0 0 INPUTS 1 2 (BRIDGE) BRIDGE MODE 8 / 4 OUTPUTS BRIDGE BRIDGE 8 ONLY 12 ON OFF CLASS 2 WIRING Audio Extron SSP 200 Surround Sound Processor 50-60Hz Audio INPUTS 1 L R 1 (LF) 2 (RF) 3 (C) 4 (SUB) 5 (LS) 6 (RS) 7 8 9 (MIX) 10 5 THRU 2 3 4 DMP EXP RS-232 Tx Rx G LAN RESET SSP 200 HDMI LF Audio CLASS 2 WIRING 12 10 8 12 10 8 12 10 8 12 10 8 LIMITER/ 14 6 14 6 14 614 6 1 2 3 4 STANDBY 1 G 2 3 4 PROTECT 18 4 4 4 4 26 1 2 12 12 12 100-240V 1.0A, 50-60Hz 1 2 3 4 1 0 2 0 3 0 4 0 XPA U 1004 SIGNAL ATTENUATION INPUTS REMOTE 8/4 OUTPUTS Extron XPA U 1004 Power Ampli er Audio Extron SM 28 Speakers Extron LS 100-240V 0.6A, 50-60Hz XPA U 1002 12 10 8 12 10 8 LIMITER/ 14 6 14 6 PROTECT 18 4 4 26 1 2 12 12 1 0 2 0 SIGNAL ATTENUATION Extron XPA U 1002 Power Ampli er 1 2 INPUTS STANDBY G CLASS 2 WIRING 1 2 REMOTE 8/4 OUTPUTS Extron SM 26 Speakers Extron HDMI Source C Extron RHB RF Extron RS Extron Figure 2. Typical Application Diagram for a 5.1.4 Speaker Setup Step 4 -- Connect control devices · To control the SSP 200 through Ethernet, connect a LAN or WAN to the LAN connector (E). · For serial RS-232 control, connect a host device to the 3-pole captive screw connector (D). The default baud rate is 9600. · For control through USB, connect a host device to the front panel USB mini-B port (see figure 3 , B, on the next page). Step 6 -- Connect power Connect a 100 to 240 VAC, 50-60 Hz power source to the AC power connector (figure 1, A, on the previous page). 2 Audio Wiring Wire the audio input and output connectors as shown at right. Use the supplied tie wrap to strap the audio cable to the extended tail of the connector. 3" 16 (5 mm) MAX. (typ) Tip Ring Sleeve Balanced Input Tip Sleeve Jumper Unbalanced Input 3-pole Audio Input Wiring NOTE: The length of exposed wires is important. The ideal length is 3/16 inch (5 mm). Tip Ring Sleeve Tip Ring Sleeve Tip Sleeve Jumper Tip Sleeve Jumper Balanced Input Unbalanced Input 6-pole Audio Input Wiring RS-232 Port Wiring To transmit and receive IR signals, connect a control device to the three-pole RS-232 connector (D) as shown below. Tx Transmit Rx Receive G Ground REMOTE RS-232 Tx Rx G RS-232 protocol defaults · 9600 baud · no parity · 8 data bits · no flow control · 1 stop bit Tip Ring Sleeve Tip NO Ground Here Sleeve Balanced Output Unbalanced Output 3-pole Audio Output Wiring Tip Ring Sleeve Tip Ring Sleeve Tip NO Ground Here Sleeve Tip NO Ground Here Sleeve Balanced Output Unbalanced Output 6-pole Audio Output Wiring Ethernet Connection The Ethernet cable can be terminated as a straight-through cable or a crossover cable and must be properly terminated for your application as shown at right. · Crossover cable -- Direct connection between the computer and the SSP. · Patch (straight) cable -- Connection of the SSP to an Ethernet LAN. Pins: 12345678 Insert Twisted Pair Wires RJ-45 Connector Front Panel Features Crossover Cable (for direct connection to a PC) End 1 Pin Wire Color End 2 Pin Wire Color 1 white-orange 1 white-green 2 orange 2 green 3 white-green 3 white-orange 4 blue 4 blue 5 white-blue 5 white-blue 6 green 6 orange 7 white-brown 7 white-brown 8 brown 8 brown T568B T568A A cable that is wired as TIA/EIA T568A at one end and T568B at the other (Tx and Rx pairs reversed) is a "crossover" cable. Straight-through Cable (for connection to a switch, hub, or router) End 1 Pin Wire Color End 2 Pin Wire Color 1 white-orange 1 white-orange 2 orange 2 orange 3 white-green 3 white-green 4 blue 4 blue 5 white-blue 5 white-blue 6 green 6 green 7 white-brown 7 white-brown 8 brown 8 brown T568B T568B A cable wired the same at both ends is called a "straight-through" cable because no pin/pair assignments are swapped. CONFIG e SOURCE 1 ATMOS PCM HDCP 2-CH EXP INPUT 234 VOLUME 5 SSP 200 SURROUND SOUND PROCESSOR AB C D E Figure 3. Front Panel Features A Status LED B Configuration port INPUTS L H C Input source format indicators D Input selection buttons R 1(LF) 2(RF) 3(C) 4(SUB) 5(LS) 6(RS) E Volume adjustment knob and LED bar 7 8 9 (MIX) 10 A Status LED -- This LED indicates the current power and boot status of the SSP 200. It lights solid green when operational and solid amber during bootup and5 reset. RS-232 RESET 3 100-240V --A MAX OUTS 1 THRU 2 3 4 Tx Rx G B Configuration port -- The SSP 200 can be configured through PCS or by using SIS commands through this USB mini-B port or through the LAN and RS-232 ports on the rear panel. In addition, this configuration port is used for firmware updates from a PC. C Input Source format indicators -- The bank of eight LEDs identify the format of the audio input. D Input selection buttons -- Push one of the buttons to select between the five audio inputs. When a button is selected, the button lights green indicating it is the active input. For digital inputs 1 through 4, the button turns amber when it is selected and the digital clock signal has not been detected. E Volume adjustment knob and LED bar -- Use the rotary encoder to adjust the output volume from 0 to 100. The default setting is 80. Configuration and Operation Extron PCS To configure and operate the SSP 200 using PCS, install the software (available on the Extron website, www.extron.com) to a PC connected to the processor via Ethernet (using the LAN connection) or the front panel USB configuration port. After the installation, start the program and connect to the device (see the SSP 200 User Guide at www.extron.com). For full instructions while operating PCS, press <F1> on the keyboard or click the ? button in the software and select Help File. Toolbelt Software To manage the SSP 200 using Toolbelt, install the software (available on the Extron website, www.extron.com) to a PC connected to the processor via Ethernet (using the LAN connection). After the installation, start the program and connect to the device by using Device Discovery to locate and then select the desired device. For full instructions while operating Toolbelt, press <F1> on the keyboard or click the Help button in the software and select Toolbelt Help. Internal Web Pages To configure the SSP 200 using the factory-installed web pages in a web browser, connect the LAN connector to a LAN or WAN. The default IP address is 192.168.254.254. There is a limited amount of configuration that can be performed with the web pages (see the SSP 200 User Guide at www.extron.com). SIS Commands To configure the SSP 200 with SIS commands via an RS-232, USB, or Ethernet connection, use the Extron DataViewer utility or a control system to send and receive SIS commands. For a list of SIS commands and variables, see the SSP 200 User Guide at www.extron.com. Firmware Updates Download firmware updates from www.extron.com to a local computer and upload them via the internal web pages or PCS (see the SSP 200 User Guide at www.extron.com). For information on safety guidelines, regulatory compliances, EMI/EMF compatibility, accessibility, and related topics, see the Extron Safety and Regulatory Compliance Guide on the Extron website. © 2020 Extron -- All rights reserved. www.extron.com 68-3281-50 Rev. A All trademarks mentioned are the property of their respective owners. 12 20 4 Worldwide Headquarters: Extron USA West, 1025 E. Ball Road, Anaheim, CA 92805, 800.633.9876, Ball, Ram Partosa, Dave LaVine Adobe PDF Library 15.0