Installation Guide for Altronix models including: Trove2KA2 Trove2 Enclosure with Keyscan Backplane, Trove2KA2, Trove2 Enclosure with Keyscan Backplane, Keyscan Backplane, Backplane

IITrove KA I28U

User Manual

Altronix TROVE2KA2 Access power integration - Fire and Safety Plus

Trove2KA2 TKA2 Trove3KA3 TKA3 Installation Guide

Click to View

Altronix TKA3 | Trove3 Backplane for Altronix/Keyscan-100620


File Info : application/pdf, 8 Pages, 883.82KB

PDF preview unavailable. Download the PDF instead.

Altronix Trove3KA3 Power Integration Enclosure Installation Instructions
Access & Power Integration

SIGNALING

Trove2KA2
- Trove2 enclosure with Altronix/Keyscan backplane (TKA2)
TKA2
- Altronix/Keyscan backplane only
Trove3KA3
- Trove3 enclosure with Altronix/Keyscan backplane (TKA3)
TKA3
- Altronix/Keyscan backplane only
Installation Guide

All registered trademarks are property of their respective owners.

More than just power.TM

Rev. TKA042816 Installing Company: _________________________ Service Rep. Name: __________________________________________

Address: _________________________________________________________ Phone #: _________________________

Overview: Trove2KA2/Trove3KA3 accommodates various combinations of Keyscan boards with or without Altronix power supplies and accessories for access systems.

Specifications:

Trove2KA2

Trove3KA3

Trove2 enclosure with TKA2 Altronix/Keyscan backplane

Trove3 enclosure with TKA3 Altronix/Keyscan backplane

· Includes: tamper switch, cam lock, and mounting hardware.

· Includes: (2) tamper switches, cam lock, and mounting hardware.

Enclosure Dimensions (H x W x D):

Enclosure Dimensions (H x W x D):

27.25" x 21.75" x 6.5" (692.2mm x 552.5mm x 165.1mm).

36.12" x 30.125" x 7.06" (917.5mm x 768.1mm x 179.3mm).

TKA2

TKA3

Altronix/Keyscan backplane only

Altronix/Keyscan backplane only

· Includes mounting hardware.

· Includes mounting hardware.

Dimensions (H x W x D):

Dimensions (H x W x D):

25.375" x 19.375" x 0.3125" (644.5mm x 482.6mm x 7.9mm).

34" x 28" x 0.3125" (863.6mm x 711.2mm x 7.9mm).

TKA2 accommodates a combination of the following: TKA3 accommodates a combination of the following:

Altronix Modules:

Altronix Modules:

· One (1) AL400ULXB2, AL600ULXB, AL1012ULXB, AL1024ULXB2, · One (1) AL400ULXB2, AL600ULXB, AL1012ULXB, AL1024ULXB2,

eFlow4NB, eFlow6NB, eFlow102NB, or eFlow104NB.

eFlow4NB, eFlow6NB, eFlow102NB, or eFlow104NB.

· One (1) T16100, ACM4(CB), ACM8(CB), MOM5, PD4UL(CB),

· One (1) T16100, ACM4(CB), ACM8(CB), MOM5, PD4UL(CB),

PD8UL(CB), PDS8(CB), VR6.

PD8UL(CB), PDS8(CB), VR6.

Keyscan Modules:

Keyscan Modules:

· One (1) CA250B, CA4500B, CA8500B, one (1) DPS-15, one (1) CIM. · Two (2) CA250B, CA4500B, CA8500B, two (2) DPS-15, two (2) CIM.

· Two (2) OCB8

· Four (4) OCB8

Agency Listings: · UL 294 - 6th edition: Line Security I, Destructive Attack I, Endurance IV, Stand-by Power II*.
*Stand-by Power Level I if no battery is supplied. · This Class B digital apparatus complies with Canadian ICES-003.
Cet appareil numérique de la classe B est conforme á la norme NMB-003 du Canada. · CE European Conformity.

Installation Instructions for Trove2/Trove3:

1. Remove backplane from enclosure prior to mounting (do not discard hardware).

2. Mark and predrill holes in the wall to line up with the top keyholes in the enclosure. Install the upper fasteners and screws in the wall

with the screw heads protruding. Place the enclosure's upper keyholes over the screws; level and secure. Mark the position of the lower

holes. Remove the enclosure. Drill the lower holes and install the fasteners. Place the enclosure's upper keyholes over the upper screws.

Install the lower screws and make sure to tighten all screws (Enclosure Dimensions, pg. 6, 8). 3. Mount included UL Listed tamper switch (Altronix Model TS112 or equivalent) in desired location,

Fig. 1

opposite hinge. Slide the tamper switch bracket onto the edge of the enclosure approximately 2"

from the right side (Fig. 1, pg. 2). Connect tamper switch wiring to the Access Control Panel

input or the appropriate UL Listed reporting device.

Enclosure

To activate alarm signal open the door of the enclosure. 4. Mount Altronix/Keyscan boards to backplane, refer to pages 3, 4.

Edge of Enclosure

Hardware: Nylon Spacer |

Metal Spacer |

Pan Head Screw |

Lock Nut

Tamper Switch (included)
To Access Control Panel or UL Listed Reporting Device

- 2 -

Trove2KA2 / Trove3KA3 Installation Guide

TKA2: Configuration of Altronix Power Supply and/or Sub-Assembly Boards and Keyscan Boards 1. Fasten metal and snap on spacers (provided) to pems which match the hole pattern for Altronix Power Supply/Chargers or Altronix Sub-Assembly boards (Fig. 2, 2a, pg. 3). Note: Please fasten metal and snap on spacers in the proper locations (Fig. 2, pg. 3). 2. Mount boards to spacers utilizing 5/16" pan head screws (provided) (Fig. 2, pg. 3). 3. Mount Altronix T16100 transformer to backplane using two locking nuts (Fig. 2, pg. 3). 4. Mount appropriate Keyscan boards into the correct positions (Fig. 2, pg. 3) by postioning spacers over appropriate holes on the backplane and depress down on board to secure spacer to the backplane (Fig. 2b, pg. 3). 5. Fasten backplane to Trove2 enclosure utilizing pan head screws (provided).
Fig. 2
Fig. 2a

Altronix Power Supply
Metal Spacer Placement

Altronix Power Supply or Sub-Assembly
Metal Spacer Placement

Pem
Nylon or Metal Spacer
Backplane Sub-Assembly

Altronix T16100

Keyscan OCB8

Plastic Spacer pre-mounted into Keyscan modules

Fig. 2b

Keyscan DPS15
Locknut

Keyscan CA250B, CA4500B CA8500B

Keyscan OCB8

Insert into TKA2 or TKA3 backplane

Keyscan CIM

Trove2KA2 / Trove3KA3 Installation Guide

- 3 -

TKA3: Configuration of Altronix Power Supply
and/or Sub-Assembly Boards and Keyscan Boards 1. Fasten metal and snap on spacers (provided) to pems which match the hole pattern for Altronix Power Supply/Chargers or Altronix
Sub-Assembly boards (Fig. 3, 3a, pg. 4). Note: Please fasten metal and snap on spacers in the proper locations (Fig. 3, pg. 4). 2. Mount boards to spacers utilizing 5/16" pan head screws (provided) (Fig. 3, pg. 4). 3. Mount Altronix T16175 transformer to backplane using four locking nuts and TKA3BK: tighten top two lock nuts first, then, utilizing
the TKA3BK bracket, insert pems through T16175 feet and backplane and tighten locknuts to the pems protruding through the backplane. (Fig. 3b, pg. 4). 4. Mount appropriate Keyscan boards into the correct positions (Fig. 3, pg. 4) by postioning spacers over appropriate holes on the backplane and depress down on board to secure spacer to the backplane (Fig. 3c, pg. 4). 5. Fasten backplane to Trove3 enclosure utilizing pan head screws (provided).

Fig. 3

Fig. 3a

Altronix Power Supply or Sub-Assembly
Metal Spacer Placement
Altronix Power Supply or Sub-Assembly
Metal Spacer Placement

Keyscan CA250B, CA4500B, CA8500B

Keyscan OCB8
Keyscan OCB8

Pem
Nylon or Metal Spacer
Backplane Sub-Assembly

Altronix T16175

Altronix Sub-
Assembly

Altronix Power Supply or Sub-Assembly
Metal Spacer Placement
Altronix Sub-Assembly

Keyscan DPS15 Locknut
Keyscan CA250B, CA4500B, CA8500B

Keyscan CIM
Keyscan OCB8

T16175
Terminals

Fig. 3b
Lock Nut

Mounting Bracket

TKA3

Mounting Hole

Keyscan OCB8

Plastic Spacer pre-mounted into Keyscan modules

Fig. 3c

Altronix Sub-Assembly

Keyscan DPS15

Locknut

Keyscan CIM

Insert into TKA2 or TKA3 backplane

- 4 -

Trove2KA2 / Trove3KA3 Installation Guide

0.45" (11.4mm)

TKA2 Dimensions (H x W x D): 25.375" x 19.375" x 0.3125" (644.6mm x 492.1mm x 7.9mm)

2.2" (55.9mm)

19.375" (492.1mm)

2.2" (55.9mm)

0.156" ( 3.96mm)

25.375" (644.6mm)

8.5" (215.9mm) 12.625" (320.7mm) 16.25" (412.8mm)

0.45" (11.4mm)

1.0" (25.4mm)
7.5" (190.5mm) 9.2" (233.7mm)

1.0" (25.4mm) 7.5" (190.5mm) 9.2" (233.7mm)

Trove2KA2 / Trove3KA3 Installation Guide

- 5 -

Trove2KA2 Enclosure Dimensions (H x W x D approximate): 27.25" x 21.75" x 6.5" (692.15mm x 546.1mm x 165.1mm)

2.00" (50.8mm)

21.50" (546.1mm) 5.25" (133.35mm) 3.5"(88.9mm) 3.5"(88.9mm) 5.25" (133.35mm)

2.00" (50.8mm)

6.25" (158.8mm)

1.25" (31.8mm)

6.25" (158.8mm) 1.25" (31.8mm)

1.5" (38.1mm)

0.5625" (14.3mm)

0.685" (17.4mm)

1.77" (45mm)

Knockouts 1.125" (28.3mm)

2.415" (61.3mm) 0.885" (22.5mm)

19.80" (502.9mm)

2.00" (50.8mm)

6.75" (171.5mm)

8.25" (209.5mm)

27" (685.8mm)

8.00" (203.2mm)

1.00" (25.4mm)

0.85" (21.6mm)

1.25" (31.8mm)

2.00" (50.8mm)

2.00" (50.8mm)

5.25" (133.4mm)

7.00" (177.8mm)

5.25" (133.4mm)

1.25" (31.8mm) 2.00" (50.8mm)

- 6 -

Trove2KA2 / Trove3KA3 Installation Guide

0.45" (11.4mm)

2.5" (63.5mm)

TKA3 Dimensions 34" x 28" x 0.3125" (863.6mm x 711.2mm x 7.9mm)
28" (711.2mm)

0.156" ( 3.96mm)

34" (863.6mm)

25" (635mm)

13.5" (342.9mm)

2" (50.8mm)

1.0" (25.4mm)
13.5" (342.9mm)

1.0" (25.4mm)

13.5" (342.9mm)

- 7 -

Trove2KA2 / Trove3KA3 Installation Guide

2.00" (50.8mm)

Trove3KA3 Enclosure Dimensions (H x W x D approximate): 36.12" x 30.125" x 7.06" (917.5mm x 768.1mm x 179.3mm)

2.00" (50.8mm) 1.25" (31.8mm)

7.12" (222.3mm)

9.5" (241.3mm)

9.5" (241.3mm) 1.78" (45.2mm)

1.55" (39.4mm)

1.25" (31.8mm)

1.07" (27.2mm)

30.12" (768.1mm) 14.01" (355.9mm)

14.01" (355.9mm)

2" (50.8mm)

1.10" (27.9mm)

G G

10.75" (273.1mm)

10.75" (273.1mm)

10.62" (269.8mm) 36.12" (917.5mm)

33.63" (854.2mm)

10.62" (269.8mm)

10.75" (273.1mm)

10.75" (273.1mm)

1.25" (31.8mm)

2"

8.75" (222.3mm)

(50.8mm)

8.62" (219mm)

8.75" (222.3mm)

7.06" (179.3mm)

1.25" (31.8mm)

Altronix is not responsible for any typographical errors. ­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­ 140 58th Street, Brooklyn, New York 11220 USA | phone: 718-567-8181 | fax: 718-567-9056

web site: www.altronix.com | e-mail: info@altronix.com

IITrove2KA2/3KA3

I28U

MEMBER

- 8 -

Trove2KA2 / Trove3KA3 Installation Guide



References

Adobe PDF Library 16.0.3 Adobe InDesign 17.0 (Macintosh)