User Guide for BioTel models including: ART-246 Blood Glucose Monitoring System, ART-246, Blood Glucose Monitoring System, Glucose Monitoring System, Monitoring System

Quick Start Guide

POWER BUTTON. Short-press of power button turns on/off the screen. PHYSICAL UP/DOWN, ENTER buttons can be used to navigate through menus. BACK BUTTON.

4 days ago — Conduct a Control Solution Test per instructions in Section D.2 of the. BioTel Care BGM User Manual. Wash your hands and testing site with warm water and soap.

BioTel Care Blood Glucose Monitor 2.1 Quick Start Guide (English)

Philips Connected Blood Glucose Monitor – BioTelemetry, a Philips company

PDF preview unavailable. Download the PDF instead.

BGM-2.1-QSG-ENG
® TEST STRIP PORT

Blood Glucose Monitoring System
Quick Start Guide
All images are for reference only
ART-246 Rev. 0

This is a Touch Screen

POWER BUTTON Short-press of power button turns on/off the screen.
PHYSICAL UP/DOWN, ENTER buttons can be used to navigate through menus.
BACK BUTTON Press of back button returns to the previous screen except in Test Mode.
HOME BUTTON Press of home button returns to the Home screen except in Test Mode.
INFO BUTTON Press of info button displays a dialog box with helpful information for the current screen.
CHARGING PORT

BEFORE YOU START
Before first use, charge the glucose meter for at least 6 hours with the AC charger included in your kit.
Conduct a Control Solution Test per instructions in Section D.2 of the BioTel Care BGM® User Manual.
Wash your hands and testing site with warm water and soap. Dry your hands well. Clean and disinfect your lancing device after every use. Clean and disinfect your meter at least once a week. Please refer to details in the manual.

TAKE A BLOOD GLUCOSE TEST
 Power on and insert a new test strip until
it is fully seated and Apply Blood appears.
 Insert a new lancet into the lancing device
and twist off its plastic cap.
IMPORTANT: The lancing device is intended for single patient use.

 Adjust the cap
to your desired puncture depth level.
 Using your thumb,
push the sliding button back. You will hear a click, indicating that the lancet carrier is locked into position.

BLOOD GLUCOSE TEST CONTINUED
 Position the end of
the device against the side of the fingertip. Press the trigger button to actuate the lancet.
 Make sure the APPLY BLOOD
screen is displayed. Touch the blood drop until the end is filled. After the test strip is filled, the device will display a countdown while calculating the reading.

 Your test result will appear
after the countdown is over. Select a Reading Tag during or after the countdown. Press the CONTINUE button to confirm your selection and send your result.
 The BioTel Care BGM® will automatically
send the results to the server. A response message from the server will be displayed if the results are sent successfully. Remove the test strip.

VIEW AND ADD LOGS
 On the Home screen, press the
LOGS icon OR use the buttons to access the logs.
 Press the FILTER button to only
view certain types of logs.
 Swipe Up/Down OR use the
buttons to scroll through stored readings and other entries.
 Press the ADD LOG button
on the Home Screen OR Logs Screen to create a new log entry.

 Press the EDIT button
to create or delete new types of logs.

 Press the
CREATE A LOG button to proceed to the screen where you can enter the value, tag and timestamp of a log entry.
 Press the SUBMIT button to save and
upload the new log entry to the server.

TELCARE, LLC
150 Baker Avenue Extension, Suite 300 Concord, MA 01742, USA
Phone: (888) 666-4530 (US) or (1) (978) 610-4688 (International)

