Instruction Manual for HDL models including: GSE MIS3680D.1, GSE MIS3680D.1 Single Phrase Inverter 3KW, Single Phrase Inverter 3KW, Phrase Inverter 3KW, Inverter 3KW
prieš 1 dieną — Single-phrase Inverter 3KW*1. For detailed information about other parts , please referred to the provided user manual. Note: After unpacking, please check if ...
File Info : application/pdf, 2 Pages, 1.66MB
DocumentDocumentVersion: V1.0 Single-phrase Inverter 3KW Datasheet GSE MIS3680D.1 Please read the datasheet carefully before use! Overview Single-phase inverter 3KW (hereinafter referred to as the `product' or `equipment') is an electrical equipment which converts DC voltage, almost from batteries, into standard household AC voltage so that it is able to be used by common appliances. Together use with the specific battery module, the product can be applied in DC-coupled systems (mostly new installation), AC-coupled systems (mostly retrofit) and Hybrid-coupled systems (mostly retrofit, and PV capacity-increase). After installation and proper commissioning, via mobile App, end users can proceed quick start -up for the product. Further, end users can check the equipment status and carry on information management. App Download Features: 1. High conversion efficiency and fast start-up 2. Strong adaptability and stability with load 3. Remotely power-on & off via cloud platform & mobile App 4. Three basic modes for end users to check via mobile App / the display screen of the product, including SELF CONSUME, BATTERY PRIORITY, PEAK SHIFT. Note: The illustrations in this datasheet are for reference only and the actual product should prevail. Appearance Inverter EMS Display Screen 540mm Cable Box (connected to Inverter) Figure 1 240mm 590mm Figure 2 Figure 3 Technical Data Overvoltage category (PV); (MAINS) PV terminal Max. PV input voltage Max. PV input current 580Vd.c. 15Ad.c./15Ad.c. Max. PV input power Full load voltage range 4800W 165Vd.c.-520Vd.c. MPPT voltage range 80Vd.c.-560Vd.c. Isc PV 18Ad.c./18Ad.c. Battery terminal Battery type Lithium or lead-acid batteries Battery voltage range 48Vd.c. Max. charge current 50Ad.c. Max. charge power 3000W Max. discharge power 4000W On-grid terminal Max. AC input power 7360VA Max. AC input Max. AC output power 230Va.c., 50/60Hz, Max. 32Aa.c. 3680W Max. AC output apparent power 3680VA Technical Data On-grid terminal Max. AC output 230Va.c., 50/60Hz, Max. 16Aa.c. Power factor range Back-up terminal 0.8 leading to 0.8 lagging Rated AC output power 3680W Max. AC apparent power Max. AC output Protection 4000VA 230Va.c., 50/60Hz, Max. 16Aa.c. Anti-islanding protection Yes DC reverse polarity protection Yes String fault detection Yes AC/DC surge protection DC Type II; AC Type III Insulation detection Yes General parameters Protective class I Ambient temperature range IP degree -25 ~ +60 IP65 Isolated method(solar) Transformerless Isolated method(battery) HF Technical Support E-mail: hdltickets@hdlautomation.com Website: https://www.hdlautomation.com HDL has all the intellectual property rights to this document and contents thereof. Reproduction or distribution for third parties are prohibited without written authorization from HDL. Any infringement of HDL's intellectual property rights will be investigated the legal liability. The contents of this document will be updated as the updates of product versions or other reasons. Unless otherwise agreed upon, this document is to be used as a guidance only. All the statements, information and recommendations in this document makes no warranty expressed or implied. © 2022 HDL Automation Co., Ltd. All rights reserved. Specifications Dimensions (W X H X D) 540×590×240mmSee Figure 2 & 3 Net weight 33KG Gross weight 38KG Noise level (dB) 25dB Cooling type natural Natural Convection Max. Operation altitude 2000m Operation humidity 0 ~ 95%No Condensation Topology Battery Isolation Communication RS485 Display LCD / Mobile App Certification & Standard IEC/EN62109-1&2; IEC/EN61000-6-1; IEC/EN61000-6-2; EN61000-6-3; IEC/EN61000-6-4; IEC/EN61000-3-11; EN61000-3-12; IEC60529;IEC60068; IEC61683; IEC62116; IEC61727; EN50549-1; AS 4777.2;NRS 097; VDE-AR-N-4105; CEI0-21; G98;G99; C10/C11 Safety Precations DANGER Please do not privately disassemble or replace any parts of the product. Otherwise, it may cause mechanical fault, electric shock, fire or personal injuries. Danger to life due to high voltages of the PV array, battery and electric shock. When exposed to sunlight, the PV array generates dangerous DC voltage which will be present in the DC conductors and the live components of the product. Touching the DC conductors or the live components can lead to lethal electric shocks. If you disconnect the DC connectors from the product under load, an electric arc may occur leading to electric shock and burns. Do not touch uninsulated cable ends. Do not touch the DC conductors. Do not wipe the product with damp cloth. Have the product installed and commissioned by qualified people with the appropriate skills only. Prior to performing any work on the product, disconnect the product from all voltage sources. WARNING The installation and testing for the product must be carried out by HDL Automation Co., Ltd. (hereinafter referred to as HDL) or its appointed service agencies. The electric construction shall comply with local laws and safety regulations. HDL will not be responsible for any consequence caused by the inexpert or faulty installation and wiring methods, which are not in accordance with the instructions contained in this datasheet. Safety Precations WARNING Please contact HDL after-sales departments or our designated service agencies for your maintenance service. Product failures caused by private disassembly are not subject to the warranty. Do not touch the product with wet hands. Do not put any heavy objects on top of the product. Do not damage the product with sharp objects. Do not install or operate the product in potentially explosive atmospheres or areas of high humidity. Do not mount the product in areas containing highly flammable materials or gases. If moisture has penetrated the product (e.g. due to a damaged enclosure), do not install or operate the product. Do not move the product when it is already connected with battery modules. CAUTION Risk of injury through lifting or dropping the product. The product is heavy. There is risk of injury if the product is lifted incorrectly or dropped during transport or when attaching to or removing from the wall. Lifting and transporting the product must be carried out by more than 2 people. To ensure the electrical parameters to match requirements, related measuring equipment are required when the product is being connected or tested. Ensure that the connection and use matched specification to prevent electric arcs or shocks. For detailed information, please refer to the provided user manual. Installation DANGER: Prior to performing installation on the product, disconnect the product from all voltage sources. For detailed information about installation site and environment, as well as the installation for battery module assembled with the product, please refer to the provided user manual. The product is outdoor version and can be installed in an outdoor or an indoor location. The mounting location must allow free access to the equipment for installation and maintenance purposes, and the EMS display screen must not be blocked. If the product is mounted at a wall or at a distance of 300mm from the wall or the structure separating it from the habitable space, the distances to other structures or objects must be increased. The following distances must remain free: 500mm ·Top: 500mm above the product ·Front: 600mm before the product ·Laterals: 600mm beside the product Installation CAUTION: Lifting and transporting the product must be carried out by more than 2 people. 1. Remove the product from the packaging box. 2. Fix the mounting panel to the wall. 3 Wiring For detailed information, please refer to the provided user manual. Quick Start For detailed information, please refer to the provided quick start guide. Mobile App For detailed information, please refer to the provided user manual. 600mm 600mm Figure 4 600mm 3. Hang the product onto the mounting panels. 4. Adjust the entire product and ensure that the product has been securely hung onto the panel. Packing List Single-phrase Inverter 3KW*1 For detailed information about other parts , please referred to the provided user manual. Note: After unpacking, please check if the product and the parte are complete.