User Manual for BraunAbility models including: S 10 Solo Static Floor Anchor, S 10, Solo Static Floor Anchor, Static Floor Anchor, Floor Anchor, Anchor

Solo static floor anchor: Installation and user manual

User manuals | BraunAbility Europe


File Info : application/pdf, 14 Pages, 691.38KB

PDF preview unavailable. Download the PDF instead.

427684 ed1 solo-static-floor-anchors installation-and-user en screen
Solo static floor anchor
Single anchoring point for dedicated wheelchair spaces

Solo static floor anchor S 10

EN

Installation and user manual

SV EN DE FR ES IT

4 Solo static floor anchor
Thank you for choosing a
Solo static floor anchor from BraunAbility!
The following manual is an important part of the product, providing you with information on how to achieve maximum performance and safe operation. Keep the manual in a safe place so that you can refer to it when necessary.
If you have any questions about your adaptation, please contact your installation engineer. If you want to know more about us and our range of car adaptation solutions visit www.braunability.eu. Once again, thank you for placing your confidence in our products!

5 Solo static floor anchor
EN

Index

Safety Installation
Operation Care instructions

6 General guidance
7 Installation planning 8 Drilling 9 Orientation
10 Fit and use
11 Maintenance

6 Solo static floor anchor

Safety
General guidance
1 It is recommended that Solo static floor anchors are installed by an experienced technician/vehicle converter.
2 Do not make any alterations to the Solo static floor anchors.

Plastic bolt cap M10 x 60 bolt

3 Do not install the floor anchors to unsound metal, wood, or plastic structures without additional and suitable reinforcement.
4 Solo static floor anchors meet the requirements of ISO 10542 & SAE J2249. Testing was conducted to the same configuration to that recommended by this guide, any deviation from the recommendation is the responsibility of the installer.

Solo static anchor

Spreader plate

M10 nut

Installation
Installation planning
1 Position the wheelchair facing forward, centrally in the designated region of the vehicle.
2 Allow a clear zone of at least 450 mm behind, and 650 mm in front of the head of the wheelchair user (Figure 1). When positioning the wheelchair, take the location of the shoulder belt anchorage into account.
3 Mark out the chosen floor anchor points, guidance positions are shown in Figure 2, and check under the vehicle if there are no brake lines, fuel tanks, or chassis parts blocking the installation.

450 mm

650 mm

7 Solo static floor anchor
EN

220 220

Installation

Seated head hight

Figure 1. Clear head and chest zones. 35°-45°

300-400 mm

330-500 mm

1100-1370 mm

Figure 2. Floor anchor placement.

8 Solo static floor anchor
Installation
Drilling

4 Drill a 11 mm hole through all layers of the car floor and counterbore the hole to 35 mm with a depth of 13 mm (Figure 3). 35 mm
11 mm Figure 3. Counterbore a hole.

13 mm

5 Mount the floor anchor throught the layers as shown in Figure 4.

If you need to modify the spreader plate to clear an obstruction, always leave at least 15 mm around the bolt hole.
It may be necessary to provide fillers between the vehicle floor convolutions to prevent these from being crushed when the nuts are tightened.

Vehicle floor

Flooring

Figure 4. Mount the floor anchor.

Installation
Orientation
6 It is essential that the slot in each floor anchor is orientated as shown in Figure 5.
Tighten to 30 Nm from underneath using the nut and the spreader plate.

9 Solo static floor anchor
EN

Installation

Figure 5. Floor anchor orientation.

10 Solo static floor anchor
Installation
Fit and use
1 Attach a tie-down onto the floor anchor by sliding the cleat on the slot (Figure 6). Slide the cleat fully home.
2 Rotate the cleat 90 degrees, clockwise or counterclock wise, to secure (Figure 7).
3 To remove the cleat from a floor anchor, turn the cleat 90 degrees and slide off.

Cleat

Figure 6. Slide on the floor anchor.

Figure 7. Turn 90 degrees.

Care instructions
Maintenance
Solo static floor anchors are made from stainless steel and therefore only require a periodic brush to remove debris from the slot and mating surfaces.

11 Solo static floor anchor
EN

Care instructions

ISO 9001:2015

C E R T I F I C AT I O N

TM

BraunAbility Safety Centre Accreddited test labatory
www.braunability.eu

BraunAbility Europe AB is certified in accordance with ISO 9001:2015
and ISO 14001:2015

Illustrations, descriptions and specifications in the user manual are based on current product information. BraunAbility Europe AB reserves the right to make alterations without previous notice. © 2024 BraunAbility Europe AB

BraunAbility Europe AB Åkerivägen 7 443 61 Stenkullen Sweden

Phone: +46 302 254 00 E-mail: info@braunability.eu www.braunability.eu

427684-1 2024/10



References

Adobe PDF Library 17.0 Adobe InDesign 20.0 (Windows)