Features of the Power Supply Unit

  • Power output: 4.6 A / 52 V DC
  • Universal AC input voltage range: ~100 – 240 V
  • Built-in power factor correction (PFC)
  • High efficiency (to 93%)
  • LED optical signalisation
  • Standby power: <0.2 W
  • Efficiency level: VI
  • Protections: SCP (short-circuit protection), overvoltage protection (AC input), OLP (overload)
  • Warranty: 2 years

1. Technical Description

1.1. General Description

The power supply is intended for supplying cameras that require a stabilized voltage of 52 V DC. The unit includes a cable with a DC5.5/2.1 plug. The power supply unit is protected against short-circuit, overload, and overvoltage.

1.2. Technical Parameters

Supply voltage~100 – 240 V; 50/60 Hz
Current consumption2.9 A
Supply power240 W max.
Efficiency (average)93%
Efficiency (10% load)90%
Power factor PF>0.95
Output voltage52 V DC
Output current tAMB<30°C4.6 A - refer to graph 1.
Output current tAMB=40°C3.2 A - refer to graph 1.
Ripple voltage250mV p-p max.
Short-circuit protection SCPelectronic, automatic recovery
Overload protection OLP110-150% of power supply, automatic recovery
Optical signalisationLED – presence of DC voltage
Operation conditionsTemperature: -10°C – +40°C, relative humidity 20%...90%, without condensation
Dimensions (LxWxH)178 x 81 x 33 [mm]
Net/gross weight0.68 / 0.75 [kg]
Protection class EN 62368-1II (second)
Length of DC cable1.5m + plug DC5.5/2.1 female
Length of AC cable1.5m + mains plug
Storage temperature-20°C...+60°C

Note: To extend the life of the power supply, a load current of 3.2 A is recommended.

Diagram Descriptions

Graph 1: Relation between output current and ambient temperature (instantaneous load). This graph illustrates that the output current capacity of the power supply is derated as the ambient temperature increases. At an ambient temperature below 30°C, the maximum output current is 4.6A. However, at an ambient temperature of 40°C, the maximum recommended output current is reduced to 3.2A.

Figure 1: Dimension of power supply. This figure shows the physical dimensions of the power supply unit: 178 mm (length) x 81 mm (width) x 33 mm (height). It also indicates the DC cable length is 1.5 meters.

1.3. Accessories

Accessories such as fuse blocks and cable adapters are available for the power supplies. For details, visit www.pulsar.pl.

2. Installation

2.1. Requirements

The power supply shall be mounted by a qualified installer possessing appropriate permissions and qualifications for connecting and operating low-voltage installations. Installation should occur in closed rooms with normal air humidity (RH=90% max. without condensation) and ambient temperatures ranging from -10°C to +40°C. The power supply must be mounted within a closed casing (e.g., a cubicle or terminal device), adhering to LVD and EMC requirements for power supplies, encasing, and shielding as per the application.

2.2. Installation Procedure

  1. Connect the DC output to the load/loads.
  2. Connect the power supply unit to the ~230 V AC line, ensuring adequate airflow around the unit.
  3. After performing tests and operation control, close the casing (cubicle).

3. Maintenance

All maintenance operations should be performed only after disconnecting the power supply from the power network. The power supply does not require specific maintenance procedures. However, if significant dust accumulation occurs, it should be cleaned using compressed air.

WEEE Mark

According to the EU WEEE Directive, electric or electronic waste must not be disposed of as unsorted municipal waste. Such WEEE must be collected separately.

PDF preview unavailable. Download the PDF instead.

PSD520460 Microsoft Word 2010 Microsoft Word 2010

Related Documents

Preview Pulsar AWOP-960PP Distribution Junction Box 9x6mm² - Technical Data and Installation
Detailed technical specifications and installation guide for the Pulsar AWOP-960PP Distribution Junction Box, designed for fire alarm systems and ensuring uninterruptible power and signal transmission in fire zones.
Preview Pulsar PG6580BCO Generator Operator's Manual
Comprehensive operator's manual for the Pulsar PG6580BCO portable generator, covering safety, assembly, operation, maintenance, troubleshooting, and specifications for both gasoline and LPG fuel.
Preview Pulsar PPS500 500 Watt Power Station Operator's Manual
Operator's manual for the Pulsar PPS500 500 Watt Power Station, covering safety information, specifications, operation, charging, storage, and handling. Learn how to use and maintain your power station safely and effectively.
Preview Pulsar PPS500 500 Watt Power Station Operator's Manual
Official operator's manual for the Pulsar PPS500 500 Watt Portable Power Station. Provides detailed instructions on safety, specifications, operation, charging methods, storage, and FCC compliance.
Preview Pulsar R80 Radar SIL Functional Safety Manual
This manual provides information on the Pulsar R80 Radar Level Transmitter, focusing on its SIL (Safety Integrity Level) capabilities, operation, installation, and maintenance for safety-instrumented systems.
Preview APS 5 Battery Pack Manual
This manual provides detailed specifications, usage recommendations, charging instructions, and safety precautions for the Pulsar APS 5 rechargeable lithium-ion battery pack, designed for Pulsar thermal imaging devices.
Preview Pulsar 510 Wizard DL Pipe Instruction Manual & User Guide
Detailed instructions and specifications for the Pulsar 510 Wizard DL Pipe vaporizer, covering setup, operation, charging, cleaning, and safety warnings.
Preview Pulsar PG4500iSR Inverter Generator Operator's Manual
This operator's manual provides comprehensive instructions for the Pulsar PG4500iSR Inverter Generator, a portable gasoline-powered unit designed for tools, appliances, camping, lighting, and backup power. Learn about its features, safe operation, maintenance, and troubleshooting for reliable service.