User Guide for CRESSI models including: Michelangelo Donatello Interface Bluetooth Grey, Donatello Interface Bluetooth Grey, Interface Bluetooth Grey, Bluetooth Grey, Grey

MICHELANGELO DONATELLO QUICK GUIDE [ [ at: www.cressi.com/manuals

7 time set return sleep alarm on/off • set h. 12/24 • set hour • set minute • set d-m/m-d • set day or month • set month or day • set year

Cressi 1946 - Official Website


File Info : application/pdf, 16 Pages, 7.98MB

PDF preview unavailable. Download the PDF instead.

Michelangelo Donatello Quick Guide Rev.04 2023
[

DOWNLOAD THE COMPLETE CRESSI INSTRUCTION MANUAL at: www.cressi.com/manuals

LONG LIFE

HIGH CONTRAST

MICHELANGELO DONATELLO
[ QUICK
GUIDE

HIGH POWER

EASY ACCESS

MULTI MODE

BATTERY

DISPLAY

BACKLIGHT

MENU

Cressi reserves the right to make changes to the instrument without notice, based on the incessant technological upgrade of its components.

OPERATING BUTTONS

Short

\ NEXT (ONE STEP)

Long (1 Sec.) \ ENTER \ ESC Long (3 Sec.) \ RETURN

3

SWITCH ON PUSH TO SWITH ON THE COMPUTER
PRE DIVE

PRE DIVE (DESAT)*

THE SCREEN SCROLL AUTOMATICALLY EVERY TWO SECONDS

* In case of desat time, in mode
AIR, FREE, GAGE the computer will alternate the pre dive screen to that of desat screen. In case of desat time in mode NITROX the computer will altrenate the pre dive screen to that of GAS screen (DONATELLO) or GAS1/2 (MICHELANGELO).

SURF TIME

DESAT TIME COUNTDOWN

NO FLY TIME COUNTDOWN
4

DEEP STOP INDICATOR

STAGE INDICATOR

!

HIGH SPEED ASCENT

OXYGEN OXYGEN TOXICITY BAR

PPO VIOLATION ! 2

ASCENT ALARM SPEED OFF

!

SAFETY FACTOR INDICATOR

BATTERY LOW

ALTITUDE MODE

5

MAIN SURFACE MENU

PRE DIVE

TIME

MODE SET

LOGBOOK

see page 11

ENTER

RETURN

ENTER

RETURN

( ) AIR MODE
( ) NITROX MODE ( ) APNEA MODE ( ) GAUGE MODE
Scroll the Mode and confirm

ENTER
RETURN
see page 10

6

DIVE-SET

TIME SET

PLANNING

ENTER

ENTER

· Deep stop ON /OFF

( ) AIR · Safety Factor SF 0/1/2 MODE · Altitude ALT 0/1/2/3 · Depth ON/OFF

SLEEP ALARM ON/OFF · SET HOUR · SET MINUTE

· PPO2 1.2 - 1.6

( ) · Deep stop ON /OFF

NITROX MODE

· Safety Factor SF 0/1/2 · Altitude ALT 0/1/2/3

· Depth OFF 50-10 m. (164-30 FT)

· % 02 21 - 50% GAS 1

· SET H. 12/24 · SET HOUR · SET MINUTE · SET D-M/M-D · SET DAY or MONTH · SET MONTH or DAY · SET YEAR

· PPO 1.2 - 1.6 GAS 1 2
· * % 02 21 - 99% GAS 2 · * PPO GAS 2
2
· Surf Time Alarm SURF-T
( ) APNEA F1-F5 (surf time factor) MODE /1':00"-10':00"/OFF · Depth Alarm DEPTH

Scroll the Mode and confirm Scroll +/and confirm RETURN

ENTER ENTER

Scroll the Mode and confirm
RETURN

1 - 50 m. (3-164 FT)/OFF

- SET 2nd TIME ON/OFF

· Step Depth Alarm STEP

2 - 25 m. (6-82 FT)/OFF

Scroll +/- 30 Min.

· Dive Time Alarm DIVE-T 0':10"-6':00"/OFF
* ONLY FOR MICHELANGELO

and confirm

ENTER

ENTER
PO2

% 02

DEPTH NO DECO TIME
SCROLL FOR INCREASE THE DEPTH
RETURN
Not avaible in FREE MODE / GAGE MODE
7

MAIN SURFACE MENU

SYSTEM MENU

PC LINK

SETTING & INFO SYSTEM CHANGE UNITS

HISTORY

CONNECT THE INTERFACE AND DOWNLOAD LATEST SOFTWARE UPDATES
[

[

ENTER
see page 8/9

ENTER
SCROLL TO CHANGE UNITS
SCROLL FOR

MAX DEPTH HISTORY

INCREASE THE DEPTH

RETURN

HOURS IN USE COUNTER

8

INFO

HIGH SPEED ASCENT ALARM

TISSUE ERASE

SERIAL NUMBER

FIRMWARE VERSION

NUMBER OF BATTERY CHANGES

ENTER
SCROLL TO CHANGE ON/OFF ALARM SPEED
RETURN
! An ascent at too high speed increases the risk of decompression sickness! This function is strictly reserved for instructors who take full responsibility for the disactivation of the high speed ascent alarm (AL.SP). In any event, when activating this function the computer will show a barred speaker icon during the entire dive.

ENTER

RETURN

SCROLL TO CHANGE

NO / YES,

AND PUSH FOR 5 SEC.

TO ERASE THE TISSUE

If you decide to erase the tissue
! nitrogen saturation using the

T.ERASE function,the computer

will not be able to calculate

any successive dives in relation

to nitrogen saturation! In any

event, do not use this function if

48 hours have not passed since

the last dive.

9

LOGBOOK MENU

( ) AIR MODE

( ) NITROX MODE

SAFETY (Page 1) DIVE

FACTOR

TIME

SAFETY (Page 1) DIVE

FACTOR

TIME

( ) APNEA MODE

(Page 1)

SESSION TIME

( ) GAGE MODE
(Page 1) DIVE TIME

MAX DEPTH AVG

TEMP.

DEPTH

SCROLL PPO2 (Page 2) MODE

MAX DEPTH

AVG DEPTH

SCROLL

PPO2 (Page 2)

TEMP. O2%

MAX SESS. DEPTH
SURF TIME

N° DIP
SCROLL (Page 2)

TEMP. DIVE TIME

MAX DEPTH

AVG DEPTH
SCROLL (Page 2)

TEMP.

BEST

SESS.

SCROLL (Page 3)

DIP TIME SCROLL

MAX

(Page 3)

DIVE

DEPTH

TIME

TIME

SEL. DIP

SEL. DIP

10 ONLY FOR MICHELANGELO

NUMBER SEL. DIP

TEMP SEL. DIP

PRE DIVE MENU AIR

NITROX

PPO2 MAX MODE

PPGOA2SM1AX O2% GAS 1

FREE

GAGE

MAX DEPTH DIVE TIME MAX DEPTH DIVE TIME

(MIN.)

(MIN.)

PPO2 MAX DEPTH

NO DECO TIME

PPO2 MAX DEPTH GAS 1

GAS INDICATOR

DEPTH

THE SCREEN SCROLL AUTOMATICALLY EVERY SECOND

(Page 2)

PPO MAX GA2S 2

O2% GAS 2

DIVE TIME (SEC.)

DEPTH DIVE TIME (SEC.)

PPO2 MAX DEPTH GAS 2

GAS INDICATOR

ONLY FOR MICHELANGELO

11

DIVE MENU
AIR
MAX DEPTH DIVE TIME (MIN.)

NITROX
MAX DEPTH DIVE TIME (MIN.)

NITROX GAS SWITCH PPO2 MAX 02%

DEPTH TEMP.

NO DECO TIME/ TOTAL

ASCENT TIME

SCROLL

(Page 2)

PPO MAX / 2

PPO2 DEPTH MAX MODE

DEPTH TEMP.
SCROLL (Page 2)

NO DECO TIME/ TOTAL ASCENT TIME
02%

PPO2 MAX GAS SWITCH DEPTH INDICATOR
ENTER (Page 2)

TIME 12

MODE

SWITCH THE GAS

TIME

AND CONFIRM

ONLY FOR MICHELANGELO

POST DIVE

FREE

GAGE

AIR

NITROX

MAX DEPTH DIVE TIME MAX (MIN.) DEPTH

DIVE SURF TIME DESAT TIME SURF DESAT TIME

TIME

COUNTDOWN TIME COUNTDOWN

(MIN.)

DEPTH N° DIP

TEMP.

DIVE TIME (SEC.)

DEPTHAVG DEPTH

TEMP.

DIVE TIME (SEC.)

MAX DEPTH

NO FLY DIVE TIME TIME

SCROLL

SCROLL

COUNTDOWN

(Page 2)

MAX NO FLY DIVE DEPTH TIME TIME
COUNTDOWN

SESSION TIME

SWITCH OFF AUTOMATICALLY IN 10 MIN.

TIME

MODE

TIME 13

SURFACE FREE
MAX DEPTH DIVE TIME (MIN.)

DEPTH N° DIP

TEMP.

DIVE TIME (SEC.)

SCROLL TWO TIMES

TO END THE SESSION (SURFACE)

SCROLL
14

YES / NO and confirm

BATTERY
LOW BATTERY (YOU SHOULD CHANGE THE BATTERY SOON)
YOU MUST CHANGE THE BATTERY
(DIVE FUNCTION IS DISABLED)

Note:

REV. 04_2023_P.P.1975

Via G. Adamoli, 501 - 16165 GENOVA - ITALY TEL. +39 010 830.79.1 - FAX +39 010 830.79.220
info@cressi.com - www.cressi.com



References

Adobe PDF Library 17.0 Adobe InDesign 18.2 (Macintosh)