Ambiane AP Installation instructions v1 October 2021
AMBIANETM AP
INSTALLATION INSTRUCTIONS
The unit must be installed by a qualified electrician in accordance with all national and local electrical and construction codes and regulations.

STEP 1.A CEILING OPENING

STEP 1.B CEILING OPENING

Prepare mounting hole with diameter between 212-214 mm.
STEP 2 PRIMARY POWER CONNECTION 1A

Use of the Adapter ring is recommended in case of a bigger ceiling opening. See step 6.B before connecting power and data
1B

Install terminal blocks on cable and connect it to the Primary power connection of Ambiane AP`s control unit.

ROBE lighting s. r. o. | Palackeho 416 | 757 01 Valasske Mezirici | Czech Republic | Tel.: +420 571 751 500 | E-mail: info@anolis.eu

www.anolis.eu www.anolislighting.com 1 4

VERSION 1 / 24_05_2021

AMBIANETM AP
INSTALLATION INSTRUCTIONS
STEP 3 DATA CONNECTION (DMX OR DALI)
1

STEP 4 SECONDARY POWER CONNECTION 48V

Install terminal blocks on DMX or DALI cables and connect them to the control unit.

DMX CONNECTION

0V Data Ground

DData -

D+ Data +

STEP 5 DIP SWITCH
1

Install terminal blocks on cable and connect it to the control unit.
STEP 6.A LUMINAIRE INSTALLATION 1
Make sure power and data cables are connected before this step.

Unscrew 2 screws on the control unit and remove plastic cover. 2

Set the DIP switches to positions according to your operation mode. The fixture can be controlled by DMX or DALI. Set 11=OFF for control by DMX or DALI.

Lift up springs on both sides, insert luminaire into ceiling opening and release springs to hold lumaire in place.

ROBE lighting s. r. o. | Palackeho 416 | 757 01 Valasske Mezirici | Czech Republic | Tel.: +420 571 751 500 | E-mail: info@anolis.eu

www.anolis.eu www.anolislighting.com 2 4

VERSION 1 / 24_05_2021

AMBIANETM AP
INSTALLATION INSTRUCTIONS

STEP 6.B LUMINAIRE INSTALLATION WITH ADAPTER RING

1

2

Slide Adapter ring under the control unit and above both spring. 3

Lift up both springs and slide Adapter ring under them. 4

Install Adapter ring to position as above.

Lift up springs on both sides, insert luminaire into ceiling opening and release springs to hold lumaire in place.

ROBE lighting s. r. o. | Palackeho 416 | 757 01 Valasske Mezirici | Czech Republic | Tel.: +420 571 751 500 | E-mail: info@anolis.eu

www.anolis.eu www.anolislighting.com 3 4

VERSION 1 / 24_05_2021

AMBIANETM AP
INSTALLATION INSTRUCTIONS
STEP 7 INSTALLTION OF ACCESSORIES - ANTI-GLARE RING
1

Insert the Anti-Glare ring into the Ambiane AP until three locks snap into slots..

Click on Anti-Glare ring.

ROBE lighting s. r. o. | Palackeho 416 | 757 01 Valasske Mezirici | Czech Republic | Tel.: +420 571 751 500 | E-mail: info@anolis.eu