Instruction Manual for Frymaster models including: 8263699, 8263700, 8263701, 8263702, 8263703, 8263818, 8263699 Common Controller with Cooling Fan Shroud, 8263699, Common Controller with Cooling Fan Shroud, Controller with Cooling Fan Shroud, Cooling Fan Shroud, Fan Shroud
3 дня назад — The reset switch is located either under the USB port, near the USB port or under the left control ... Controller displays READING COMPLETED, PLEASE REMOVE USB. 8 ...
Follow these instructions to update. Software and replace the Control. Products touchscreen controller with the Common Controller with a Cooling Fan/Shroud.
File Info : application/pdf, 7 Pages, 2.19MB
DocumentDocumentREAD THIS BEFORE STARTING! DO NOT ATTACH THE NEW CONTROLLER YET!!!!!!!!!!!!!!! The software loaded on the enclosed USB drive MUST be loaded onto the fryer BEFORE attaching the new controller. This updates the existing boards and controllers on the fryer to recognize the new controller. Attaching the new controller prior to updating the software on the fryer, may cause major complications due to incompatibility. If the controller being replaced is the far-left controller in the fryer, move another OLDER STYLE controller to the far-left position in the fryer. DO NOT ATTACH THE NEW CONTROLLER YET! Ensure the LED's on the SIB board, in the open controller opening are illuminated prior to updating software. If not, ensure the fuse is inserted and/or switches are on. Update the fryer software using the enclosed USB drive. Once the software is updated and verified on all existing controllers and boards, follow the instructions on the following pages to attach the new controller to the open controller position in the fryer battery. McDonald's Controller Conversion Replacement Instructions *8197984* 05/2025 FRYMASTER DEAN 8700 LINE AVENUE, SHREVEPORT, LA 71106 Instruction Sheet 318-865-1711 800-551-8633 WWW.FRYMASTER.COM EMAIL: FRYSERVICE@FRYMASTER.COM Follow these instructions to update Software and replace the Control Products touchscreen controller(s) with the Common Controller with Subject: 8263699, 8263700, 8263701, 8263702, 8263703, 8263818 McDonald's Control Products to Common Controller Replacement Instructions a Cooling Fan/Shroud. Models affected: McDonald's BIELA14-T, BIGLA30-T Touch Fryers prior to April 2022. ALL steps MUST be completed to update the fryer properly before changing the controller(s). In This Kit Complete the procedures in sequence and DO Part # Description Qty NOT SKIP any steps. · The software files are on the USB flash VARIES COMMON CONTROLLER W/ MCD SOFTWARE 1 drive included with this package. VARIES USB WITH SOFTWARE 1 · The software update process takes 8197984 INSTRUCTIONS 1 approximately 30 minutes to complete. · DO NOT start the update process until you have at least 30 minutes when the fryer will not be in use. · Prior to replacing a touch screen controller, the software MUST be updated using the supplied USB with software, before replacing the controller. Step 1 Check Product Availability Ensure enough products are cooked to cover 30 minutes of operations while the fryer is updating. Step 2 Power Cycle the Fryer To power cycle the system, PUSH and HOLD the black toggle reset switch for 60 SECONDS. The reset switch is located either under the USB port, near the USB port or under the left control box (see Figures 1 through 3). If the switch is not accessible, unplug the fryer or turn off the breaker to the fryer. Figure 2 Step 3 Pull the Filter Pan Pull the filter pan slightly out from the cabinet until a "P" is visible on the top right corner of the display (see Figure 4). Figure 1 Figure 3 Step 4 Turn OFF Fryers Press the power button on each display to ensure ALL controllers are OFF. Figure 4 Step 5 Reset the fryer on the Left screen (NOTE: If the far-left controller is not operational, swap positions with another operational older style controller (see Figure 4), if mixing controller types. An older style controller MUST always be in the FAR-LEFT position when mixing controller types). 1. On the LEFT screen, press 1650 FIB-RESET 2 YES SERVICE SERVICE 2. RESET COMPLETED SUCCESSFULLY is displayed once the reset is complete. 3. Press . CREW MODE *8197984* Document Number: FRY_INST_8197984 05/2025 1 of 6 Step 6 Update the Software The software only needs to be loaded in the USB port in the far-left fryer cabinet and it will update the UI, VIB and FIB boards in the system. 1. On the LEFT screen press SERVICE SERVICE 1650 TECH MODES SOFTWARE UPGRADE 2. INSERT USB. The USB port is located inside the far-left cabinet, on the left-hand side. Slide or lift the cover up to reveal the USB port (see Figure 5). These may differ in appearance. 3. Insert the USB flash drive (see Figure 6). 4. The controller displays IS USB INSERTED? YES NO 5. Press the YES button after the USB flash drive is inserted. 6. Controller displays READING FILE FROM USB. PLEASE DO NOT REMOVE USB WHILE READING. Figure 5 7. Controller displays READING COMPLETED, PLEASE REMOVE USB. 8. Remove the USB flash drive and lower cover over the USB slot. Figure 6 9. Press the YES button after the USB flash drive is removed. 10. Controller displays CONFIRM CONTROLLERS AVAILABLE FOR UPGRADE UIB, SIB, VIB AND FIB. 11. Press the YES button to continue. 12. Controller displays UIB/VIB/SIB/FIB DATA TRANSFER IN PROGRESS, WILL COMPLETE IN X MINUTES for each board. 13. Controller displays UIB/VIB/SIB/FIB UPGRADE IN PROGRESS, WILL COMPLETE IN X MINUTES for each board. 14. When the software update is complete, the far-left controller will display UPGRADE COMPLETE? YES on followed by the rest of the controllers displaying SOFTWARE UPGRADE COMPLETED. 15. Press the YES button. 16. The far-left controller displays UPGRADE COMPLETED, POWER CYCLE THE SYSTEM; the other controllers continue to display SOFTWARE UPDATE COMPLETED. 17. Power cycle the system as shown in step 2. ENSURE THE SWITCH IS PRESSED AND HELD FOR 60 SECONDS. Failure to press and hold the reset switch long enough, may cause an incomplete software update. 18. While the fryer is rebooting some controllers may take up to 10 minutes to reboot while the software is loading. 19. Once all controllers have returned to the power standby switch , go to the next step. Step 7 Verify the software update 1. On ALL the screens, press SOFTWARE VERSION 2. When the versions are displayed, confirm they all match the versions below: UIB = 04.00.131 or 04.00.132 Korea SIB = 04.02.000 VIB = 01.03.003 FIB = 01.01.046 3. If software versions match on ALL screens, press and proceed to Step 8 Reposition the Filter Pan. 4. If software versions DO NOT match, press and repeat Step 6 - Update the Software. Step 8 Reposition the Filter Pan Push the filter pan back into the fryer until a "P" is NOT visible on the top right corner of the display. Step 9 Power Cycle the Fryer 1. Power cycle the system one more time as shown in step 2. ENSURE THE SWITCH IS PRESSED AND HELD FOR 60 SECONDS. Failure to press and hold the reset switch long enough may cause an incomplete software update. Continued on the next page. 2 of 6 Document Number: FRY_INST_8197984 05/2025 Step 10 Replace the Controller 1. Disconnect the fryer from the electrical power supply. On gas fryers the fuse located under the bottom of the control box, can be removed, to remove power from individual control boxes (see Figure 7). Turn the fuse cap to remove. On electrical fryers, the indivudual fryer can be switched off (see Figure 8). Figure 8 2. Remove the acorn nuts, washer and plates on both ends of the guard if applicable Figure 7 (see Figure 9) and discard. 3. Slide one end of the guard up the rail at an angle until it can be removed if applicable (see Figure 10) and discard. 4. Remove the two Phillips head screws from the upper left and right corners of the controller (see Figure 11). 5. Slide the controller up Figure 9 Figure 10 to disengage it from the bottom of the bezel (see Figure 12). 6. Lift the controller out from the bezel (see Figure 13). 7. Lower the controller and rest it on the bottom of the control Figure 11 Figure 12 Figure 13 box (see Figure 14). The black tether on the right will support the controller 8. Disconnect the RJ45 cable from the SIB board FIRST (see Figure 15). 9. Disconnect the ground cable, the locator cable, the speaker cable and the USB cable from the far-left Figure 15 Figure 16 controller (if applicable) (see Figure 16). Tuck the single wire locator Figure 14 cable out of the way, as it is NOT used with the new controller. 10. Disconnect the Figure 18 lanyard tether from the frame (see Figure 17) to remove the controller. 11. Remove the controller. The controller will slide up and out of the Figure 17 controller protector cage. 12. Remove the bezel by removing the two screws on Figure 19 the bottom of the bezel (see Figure 18) and tilting the bezel up from the bottom and lowering towards the front of the fryer (see Figure 19). Continued on the next page, 3 of 6 Document Number: FRY_INST_8197984 05/2025 13. On gas fryers, the speaker bracket and relay(s) must be relocated towards the rear of the box to allow room for the cooling housing (see Figure 20). On electric fryers, the speaker bracket must be replaced with a different speaker bracket and an adapter plate. 14. Remove the two (2) screws attaching the speaker to the bracket (see Figure 21). 15. Remove the two (2) screws attaching Figure 20 the speaker bracket to the component box (see Figure 22). 16. For gas reattach the speaker to the bracket (see Figure 23). For electric attach the speaker to the new bracket (see Figure 23). 17. For electrics, attach the speaker bracket to the Figure 22 mounting plate (see Figure 23A). 18. Rotate the speaker 180°so the speaker is facing the rear of the component box and reattach the bracket to the component box using the screws and the existing holes (see Figure 24). Figure 23A Slightly bend the speaker down. Figure 24 19. Remove the two (2) screws attaching the relay(s) to the top of the component box (see Figure 25). Relays in electric fryers may differ in appearance. 20. On gas fryers, using the supplied plate, attach the relay to the plate. Attach to the control box using the existing holes as shown (see Figure 26 & 26A). 21. Reattach the bezel removed in step 12. 22. With the replacement controller face down resting in the control box, reattach the lanyard tether Figure 26 Figure 26A FIRST. Failure to reinstall the lanyard may result in damage to the SIB board connectors when connecting or disconnecting cables (see Figure 27). 23. Attach the speaker wire, Figure 28 the ground wire and the USB with the sleeve to the USB extension, if the controller is in the far-left position on the fryer (see Figure 28). NOTE: NEW controllers without locator plugs have two (2) USB connectors. If attaching to the USB extension on the far-left Figure 29 controller, attach the USB connection with the sleeve (see Figure 29). 24. Attach the RJ45 cable to the SIB board (see Figure 30). 25. Restore power to the associated controller. Continued on the next page. Figure 21 Figure 23 Figure 25 Figure 27 Figure 30 4 of 6 Document Number: FRY_INST_8197984 05/2025 26. Wait a minute or more to ensure the cooling fan on the top of the controller is functioning before attaching the controller to the bezel. 27. Attach the controller to the bezel reversing steps 4, 5 and 6. Attach using the two (2) screws removed in step 4. 28. For new controllers without a locator wire, the Vat ID must be set up correctly to operate correctly and avoid a duplicate Vat ID error. At bootup, if a DUPLICATE BOARD VAT ID is detected, ALL controllers display the VAT ID setup screen (see Figure 31). Select the correct VAT ID for each vat. Vat ID #1 is far left controller. Vat ID #2 is the next controller to the right, etc. If changes are required, go to Service>Service>1650>Tech Modes>Select Vat ID. Ensure the Vat ID is set up for correct vat ID number. Once all VAT IDs are selected, power cycle the fryer battery using process in Step 2 on the first page. 29. Setup the controller (locale, energy type, vat type, oil system type, waste oil type, etc.) by going to Settings>Service>1650. If the controller being replaced is in the far-left position, the current date and time and Lane Assignments need to be setup by going to Settings>Service>1234. Setup MUST be performed prior to readdress. 30. Once setup is complete on all replaced controllers, CYCLE POWER TO ENTIRE FRYER Figure 31 SYSTEM using process in Step 2 on the first page again. 31. Check software version by pressing the information (?) button; press the down arrow; press the SW version button. The controller displays INTIALIZING. Ensure that the M4000 (UIB)/VIB/FIB/SIB/OQS software versions match the versions on the other controllers. If the software versions do NOT match, update the software again. 32. The newer controllers are brighter and crisper than older style controllers. Do not adjust settings. See Next Page for Troubleshooting Assistance. Troubleshooting CAN COMMUNICATION FAILED, CAN COMMUNICAITON ERROR DURING UPDATE OR SOFTWARE THAT FREEZES DURING AN UPDATE. 1. Ensure the 8075632 end of line terminator resistors are installed in SIB board in the far-left control box and on the FIB board. If they are missing or if the current resistors are bad, replace with resistors in the kit. The resistors should read 120 ohms. 2. Try updating the software again but ensure that only controllers with software that DOES NOT MATCH the software on the first page, are located in the far-left position when updating software. Any controller that has software that matches the software version on the first page, needs to be disconnected while updating the software and located in any position other than the far-left controller. 3. Power cycle fryer ensuring that the reset switch is pressed and held for 60 seconds or greater, or power is removed for 60 seconds or greater. 4. Update the software or menus again. 5. Check software versions or menus. If they still do not update repeat step #1 and recheck. Software upgrade not available (Grayed out) 1. Ensure ALL controllers are OFF. 2. Ensure the software upgrade is performed on the far-left controller. VAT #2 will be grayed out, as software updates can NOT be performed on any controller other that VAT #1 controller. 3. Go to SOFTWARE VERSION on all the controllers and ensure that BOARD ID's are correct. VAT 1=1, VAT2=2, etc. If BOARD ID on VAT 1 is not 1 then a pin is in the wrong location in the 6-pin locator connector. It should be in the following position (see photo) for VAT 1. 4. Ensure the VAT ID locator wire is not loose for fryers with hardware VAT ID locators. 5. For fryers with the Common Controller with the metal surround bezel, ensure the VAT ID in Service>Service>1650>Tech Modes>Select Vat ID is set for Vat ID 1 for the far-left controller. 5 of 6 Document Number: FRY_INST_8197984 05/2025 Software or menus do not update 1. Power cycle fryer ensuring that the reset switch is pressed and held for 60 seconds or greater, or power is removed for 60 seconds or greater. 2. Recheck software versions or menus. If they still do not update repeat step #1 and recheck. Display reboots automatically during an update 1. Power cycle fryer ensuring that the reset switch is pressed and held for 60 seconds or greater, or power is removed for 60 seconds or greater. 2. Update the software or menus again. 3. Check software versions or menus. If they still do not update repeat step #1 and recheck. Controller keeps rebooting after an update 1. Ensure ALL controllers display OFF. 2. Update the menu files again. 3. Power cycle fryer ensuring that the reset switch is pressed and held for 60 seconds or greater, or power is removed for 60 seconds or greater. 4. Check menus. If they still do not update repeat step #1 and recheck. Change Filter message after an FIB2 Reset 1. This is normal after an FIB2 reset. 2. Pull the filter pan slightly out slightly of the cabinet until a "P" is visible on the top right corner of the display for 30 seconds or greater until the message disappears. 3. Push the filter pan back into the fryer. Controller displays SPIFI FILE ERROR and SD CARD FILE ERROR 1. Flash drive not removed when prompted during software update. Remove the USB, power cycle the fryer, ensuring the power is removed for 60 seconds or greater. Controller displays NO SPIFI CRC AVAILABLE, SD CARD FILE ERROR, USB FILE ERROR 1. Power cycle the fryer, ensuring the power is removed for 60 seconds or greater. 2. If the controller doesn't recover, the memory is corrupted. Replace the controller. Controller display doesn't return after an update. Screen remains black for longer than 5 minutes. 1. Power cycle the fryer, ensuring the power is removed for 60 seconds or greater. 2. If the controller doesn't recover, the memory is corrupted. Replace the controller. Prior to calling the Technical Assistance Hotline, try the troubleshooting steps above. If the troubleshooting steps do not correct the issue, call: 1-800-551-8633 6 of 6 Document Number: FRY_INST_8197984 05/2025