The full version of the manual in PDF format is available on the website www.salus-controls.eu Product Compliance This product complies with the following EU Directives: Electromagnetic Compatibility 2014/30/EU, Low Voltage Directive 2014/35/EU and RoHS 2011/65/EU. Full information is available on the website www.saluslegal.com Safety Information
Installation Manual. Programmable, wired thermostat with digital display for the control of temperature in UFH & RAD systems.
File Info : application/pdf, 6 Pages, 7.13MB
DocumentDocumentVI 2020 [ENG] 150 . RM-16A Programmable, wired thermostat with digital display for the control of temperature in UFH & RAD systems Model: VS30W (white), VS30B (black) Proper thermostat placement M M . 20 . Installation Manual IMPORTER: QL CONTROLS Sp. z o.o. Sp. k. ul. Rolna 4, 43-262 Kobielice PRODUCER: Salus Limited 6/F, Building 20E, Phase 3, Hong Kong Science Park, 20 Science Park East Avenue, Shatin, New Territories, Hong Kong www.salus-controls.eu SALUS Controls is a member of the Computime Group Maintaining a policy of continuous product development SALUS Controls plc reserve the right to change specification, design and materials of products listed in this brochure without prior notice. Introduction The VS30 thermostat controls temperatures of individual heating zone in underfloor heating systems. Thermostat allows for significant savings thanks to the possibility of maximum reduction the set temperature. The full version of the manual in PDF format is available on the website www.salus-controls.eu Product Compliance This product complies with the following EU Directives: Electromagnetic Compatibility 2014/30/EU, Low Voltage Directive 2014/35/EU and RoHS 2011/65/EU. Full information is available on the website www.saluslegal.com Safety Information Use in accordance with national and EU regulations. Use the device only as intended, keeping it in a dry condition. The product is for indoor use only. Installation must be carried out by a qualified person in accordance with national and EU regulations. Terminals description Terminal L,N NSB SL S1, S2 Description Power Supply 230 V AC Night SetBack (output 230 V AC) Switched output (230 V AC) External temperature sensor Button Functions Button Function Increasing / decreasing temperature or value Selection of the operating mode, switching between values Short press - selection confirmation Long press - entry to or exit from the menu + Long press causes blocking or unlocking the thermostat + + Long press enters the installer mode LCD Icon description 1234567 8 9 20 10 19 11 18 12 17 13 16 14 15 1. Current active mode 2. Comfort mode 3. Standard mode 4. Economic mode 5. Automatic mode 6. PARTY mode 7. Holiday mode 8. Frost protection mode 9. Temperature unit 10. Manual mode / temp. override 11. Current / set temperature 12. Program number 13. AM/PM 14. Key lock 15. Day of the week 16. Settings 17. Time 18. Additional temp. sensor 19. Cooling 20. Heating Installation The VS30 thermostat has been designed for flush mounting in a standard electrical box with a diameter of 60 mm. 1 2 3 VS30 thermostat in connection with a boiler with a "NO" voltage free terminal through the RM-16A relay NSB function is not active. L AC 230V M T T Note: Use the rear plate of the VS30 thermostat only with this model. Wiring diagrams An additional temperature sensor T is optional. VS30 thermostat in connection with actuator or pump L AC 230V S1 S2 NSB SL L N OUTPUT OR VS30 N VS30 thermostat in connection with wiring centre In this diagram, the VS30 thermostat manages the NSB function, more details about NSB function can be found on the next page. VS35 INPUT S1 S2 NSB SL L N T VS30 OUTPUT S1 S2 NSB SL L N T L N SL LN L N SL KL08NSB KL06 L AC 230V N Note: In the KL06 wiring centre, the SL terminal is marked with an arrow icon . S1 S2 NSB SL L N OUTPUT VS30 N NO OUTPUT COM NC SL INPUT230VAC N POWER SUPPLY L 230 V AC / 50 Hz Time and date setting Note: During the first start-up, thermostat will automatically start time and date setting - in this case go to step 4. Press any button to highlight the screen, then follow the steps below: 1 2 3 sek. 3 4 Select the time format with or buttons. Press to confirm the changes. 5 6 Use or buttons to set the hour. Press to confirm the changes. 7 Similarly to steps 5 and 6, set the minutes, year, month and day. Temperature setting Press any button to highlight the screen, then follow the steps below: 1 2 Current temperature. 3 Temperature set in the selected operating mode 4 Set the temperature with or buttons. Press to confirm the changes. Manual mode - temperature settings There are 4 temperature levels available. In manual mode only one temperature level is active (icon in the frame indicates which mode is currently chosen). For each temperature levels you can set a different temperature. - Comfort mode - Standard mode - Economic mode (when this mode is selected on the NSB output appears 230 V AC voltage) - Frost protection mode. Usually used in a longer period of absence or during the holidays (available only in heating mode). Thermostat also has 2 additional modes: - PARTY mode sets the comfort temperature for a defined time by the user (maximum 9 hours 50 minutes). - The HOLIDAY mode sets the frost protection temperature for a user defined period of time (maximum 99 days). Press any button to highlight the screen, then follow the steps below: 1 2 Choose the temperature mode using or buttons. Programming Press any button to highlight the screen, then follow the steps below: 1 2 3 sek. 3 4 Use button to choose days range for schedule: - whole week - weekdays - weekends - each day separately Set the program start time: 5 Press to confirm the changes. 6 7 8 9 10 Select the operating mode. 11 Repeat steps 5 - 10 to set time and temperatures for next time ranges. No hour (--:--) on the display means whole day is planned already. Schedule can be divided into maximum 6 time ranges. NSB function - automatic mode The NSB (Night SetBack) function can automatically change temperatures on VS35 daily thermostats via VS30 programmable thermostat connected to a wiring centre (or another external clock). NSB function switches between comfortable temperature and economic temperature . To activate the automatic mode, select the icon. On display together with the icon, the controller indicates active temperature mode: or . Note: For the NSB function to work, it is necessary to connect the wirings properly. Connection diagrams can be found on the previous page. Press any button to highlight the screen, then follow the steps below: 1 2 Select the automatic mode using or buttons. Installer settings Press any button to highlight the screen, then follow the steps below: 1 2 3 sek. 3 sek. 3 sek. 3 4 Select the service parameter using or buttons. The parameter value is set by or . Press to confirm the changes. Note: To restore the thermostat's factory settings, in step 2 set the PSuu to 47 code, and confirm the selection with the button. dxx Function Value Description Default value 0 PWM algorithm d01 Control method temperature 1 Span ±0.25°C 0 2 Span ±0.5°C d02 Offset temperature from -3.0°C to +3.0°C If the thermostat indicates wrong temperature, you can correct it by ± 3.0°C 0°C d03 Using a floor temperature sensor (S1, S2) 0 1 No sensor Sensor is connected 0 External sensor used for air Thermostat measures the 0 temperature only on the d04 or floor temperature measurement external sensor 0 The sensor is used (Function is active, 1 as a protection against when d03=1) overheating the floor d05 Cooling mode control method 1 2 Span ±0.5°C Span ±1.0°C 2 d06 Type of thermoelectric actuator 0 1 NO - normally open NC - normally closed 1 0 OFF d07 Valve protection 1 1 ON d08 Frost protection temperature 5-17°C Frost protection / Holiday mode temperature 5°C 0 12 hour d09 Clock format 1 1 24 hour 0 OFF d11 Daylight Saving Time 1 1 ON d12 Heating temperature limit 5-35°C The maximum heating temperature that can be set by the user 35°C d13 Cooling temperature limit 5-40°C The minimum cooling temperature that can be set by the user 5°C Maximum floor In order to protect the floor temperature from overheating, heating d14 (this function is active 6-45°C will be turned OFF, when the 27°C in heating mode when maximum temp. of the floor d04 = 1) sensor will be reached Minimum floor In order to protect temperature the floor, heating will d15 (this function is active 6-45°C be turned ON, when the 10°C in heating mode when minimum temp. of the floor d04 = 1) sensor will be reached Lower floor temperature d16 limit for cooling (this function is active when d04 = 1) 6-45°C In order to protect the floor, cooling will be turned OFF, when the minimum temp. will be reached 6°C d17 Choice of the default program 1-5 Selection 1 of the 5 default programs 1 d18 Operating mode HEATING / COOLING 0 1 Heating system Cooling system 0 Error codes Error code Description Err02 Err03 Err04 The maximum / minimum floor temperature has been exceeded Temperature sensor is faulty Temperature sensor is shorted Relay module SALUS Controls RM-16A mounting in a box Ø60 mounting only inside buldings Relay module RM-16A opens and closes the circuit in order to affect the work of other devices. Some uses of the module RM-16A with other Salus products are shown below: 1. Connection of the thermostat with the high voltage relay 230V (e.g. VS30/RT200/ERT20/ERT30/ERT50/ VS10) with a gas boiler which requires free-voltage output NO/COM or NC/COM 2. Connection of the SALUS temperature regulator with the NO/COM relay (e.g. 091FL) with the boiler control which requires NC/COM output (NC/COM output is normally required in the solid fuel boiler controls ) 3. Connection of the receiver transmitting power higher than it is allowed by the relay in a regulator. The maximum electricity consumption of the receiver cannot exeed 16A 4. Connection of the devices other than electro thermal actuators with the wiring centre ( KL06-M/ KL08NSB /KL08RF/KL10/KL10RF) e.g. if you want to connect a pump or an electric heating mat instead of a electro thermal actuator. IMPORTER: QL CONTROLS Sp. z o.o. Sp. k. ul. Rolna 4, 43-262 Kobielice PRODUCER: Salus Limited 6/F, Building 20E, Phase 3, Hong Kong Science Park, 20 Science Park East Avenue, Shatin, New Territories, Hong Kong Relay module SALUS Controls Product code: RM-16A Symbol meaning selecting electric electronic gear. Putting used gear with other waste products is strictly forbidden. The declaration of compliance is on www.salus-controls.pl site Made in Poland The declaration of compliance is on www.salus-controls.pl site Made in Poland Relay module RM-16A www.salus-controls.eu SAFETY INFORMATION Before connecting the relay module with a different device make sure that its parameters are consistent with the RM-16A module specification. Incorrect connection may cause undesirable action, excessive overheating and combustion hazard. To avert the hazard make sure that the relay module RM-16A is correctly connected. The connection of the device can be done only by a qualified installer who has up-to-date eligibility. INTRODUCTION Relay module RM-16A opens and closes the circuit in order to affect the work of other devices. Some uses of the module RM-16A with other Salus products are shown below: 1. Connection of the thermostat with the voltage relay 230V (e.g. VS30/RT200/ERT20/ ERT30/ERT50/VS10) with a gas-fired boiler which requires free-voltage output NO/COM or NC/COM 2. Connection of the SALUS thermostat with the NO/COM relay (e.g. 091FL) with the boiler control which needs NC/COM output (NC/COM output is normally required in the solid fuel boiler controls) 3. Connection of the receiver transmitting power higher than it is allowed by the relay in a regulator. The maximum electricity consumption of the receiver cannot exeed 16A 4. Connection of the devices other than electro thermal actuators with the wiring centre ( KL06-M/KL08NSB /KL08RF/KL10/KL10RF) e.g. if you want to connect a pump or an electric heating mat instead of a electro thermal actuator. PRODUCT SPECIFICATION Power: INPUT NO/COM: OUTPUT NC/COM/NO: INPUT SL: POWER SUPPLY N/L: Measurements: 16A / 250V AC, 4000VA Connection of a regulator with the free voltage relay NO/COM Output receiver Connection of the regulator with the voltage relay 230V Power of 230V AC/50Hz 47x47x21 VISUAL ASPECT relay output (NO, COM, NC) Control input with free-voltage output LED signalling short circuitof the relay output VOLTAGE FREE INPUT NO COM NO COM NC RM-16A SL INPUT 230 V AC N 16 A / 250 V AC 4000 VA POWER SUPPLY L 230 V AC / 50 Hz Power supply of the modul RM-16A-230V AC Control input with the voltage output 230V CONNECTION DIAGRAMS 1. Connection of the thermostat with a voltage relay 230V (e.g. VS30/RT200/ERT20/ERT30/ ERT50/VS10) to a gas boiler which requires free-voltage output NO/COM. Thermostat 230V A boiler with a free-voltage relay CONNECTION DIAGRAMS 2. Connection of the SALUS temperature regulator with NO/COM relay (e.g. 091FL) with a boiler control which requires NC/COM output ( NC/COM output is normally required in solid fuel boilers controls). Thermostat with a free-voltage relay A boiler with NC/ COM input CONNECTION DIAGRAMS 3. Connection of the receiver transmitting power higher than it is allowed by the relay in a regulator. The maximuml electricity consumption of the receiver cannot exeed 16A A Thermostat with a free-voltage relay A thermostat with a high voltage relay CONNECTION DIAGRAMS 4. Connection of the devices other than electro thermal actuators with the wiring centre ( KL06-M / KL08NSB / KL08RF / KL10 / KL10RF) e.g. if you want to connect a pump or an electric heating mat instead of a electro thermal actuator. Power Supply Wiring centre: KL06-M / KL08NSB / KL08RF / KL10 / KL10RF zone 1 zone 2 zone 3 etc. . max.16A Pump -> max 16Amps or Heating mat -> max 16Amps or Actuators -> max 16 Amps Heating mat max.16AAdobe Acrobat Pro DC (32-bit) 21.1.20145 Adobe PDF Library 15.0