Instructions for LATICRETE models including: PRIMER Latex Floor Primer, PRIMER, Latex Floor Primer, Floor Primer, Primer
File Info : application/pdf, 3 Pages, 177.93KB
DocumentDocumentDS-1236-0922 PRIMER PRIMER is a concentrated premium quality, water-based primer designed to be applied prior to the installation of LATICRETE Underlayments. PRIMER penetrates deeply into substrates and maximizes bond strength. FEATURES/BENEFITS § PRIMER is multi-purpose and can be used on a wide range of substrates. § PRIMER may be broom, roller, or spray applied. § PACKAGING 5 Litre Bottle. SHELF LIFE PRIMER should be stored in original packaging. Use within one (1) year of date of manufacture. Do not allow PRIMER to freeze. SUITABLE SUBSTRATES (INTERIOR ONLY) § Concrete § Vinyl Tile § Cement Terrazzo § Exterior Glue Plywood § Ceramic Tile and Stone § Cement Mortar Beds § Cement Backer Board* * Consult cement backer board manufacturer for specific installation recommendations. MANUFACTURER LATICRETE Australia Pty Ltd 29 Telford Street Virginia, QLD 4014 Australia Telephone: Toll Free: Fax: Internet: 07 3865 1599 1800 331 012 07 3865 2250 www.laticrete.com.au ©2022 LATICRETE Australia Pty Ltd | www.laticrete.com.au | All trademarks shown are the intellectual properties of their respective owners. 1 Data Sheets are subject to change without notice. For latest revision, visit www.laticrete.com.au DS-1236-0922 Limitations § Do not install when surface temperature is below 4°C, when ambient temperature is expected to be below 10°C during placement or before material takes final set or when temperature will be above 32°C. § Adhesives/mastics, mortars and grouts for ceramic tile, pavers, brick and stone are not replacements for waterproofing membranes. When a waterproofing membrane is required, use a LATICRETE Waterproofing Membrane on top of the dry LATICRETE underlayment. § Do not install LATICRETE PRIMER or underlayments over particleboard, chipboard, hardboard (Masonite), Luan panels, asbestos, interior glue plywood, gypsumbased patching materials, asphalt, coal tar, or lightweight insulating concrete or any other dimensionally unstable materials Cautions Before using any LATICRETE product: § Read and understand the Product Data Sheet and Safety Data Sheet (SDS). § Perform a mock-up to ensure product will perform as required. § Check www.laticrete.com.au for any technical bulletins or updated information about the product and its application. § PRIMER is water based and is non-hazardous under normal conditions of use. In case of skin contact, wash immediately with water. § Wear gloves and protective goggles. § When spraying the product, avoid breathing the fine mist and use a NIOSH approved respirator. § Contact your local LATICRETE Technical Sales Representative with any questions. § Not for submerged applications. § Keep out of reach of children. TECHNICAL DATA VOC Product Information Green Building Council of Australia Green Star Office Design & Interior VOC: 3 grams/litre Actual field performance will depend on installation methods and site conditions. specifications are subject to change without notification. Technical data shown in LATICRETE product data sheets and technical data sheets are typical but reflect laboratory test procedures conducted in laboratory conditions. Actual field performance and test results will depend on installation methods and site conditions. Field test results will vary greatly due to variability of critical job site factors. INSTALLATIONS Surface Preparation § Refer to TDS 1230 Substrate Preparation and Primer Guide for more detailed substrate preparation instructions. § All concrete surfaces must achieve an ICRI CSP Profile of 3 - 5. § Clean substrate to eliminate dust, dirt, oil, grease, paint or any contaminants which may inhibit bonding. Do not use chemicals to clean substrate. Remove any loose particles by vacuuming and damp sponging. § Inspect for contraction joints, construction joints and cracks in the substrate which may be subject to movement after installation of a LATICRETE self-leveling underlayment. These must be maintained as joints through the LATICRETE selfleveling underlayment. § For exterior glue plywood substrates use 3.2# galvanized diamond metal lath. § Maintain substrate temperature between 4 32°C and air temperature between 10 32°C during installation and throughout drying. Provide adequate ventilation to ensure uniform drying. § LATICRETE Underlayments shall be installed over PRIMER once cured, typically, 3 to 5 hours after application depending on ambient and sustrate conditions. Refer to TDS 1230 Substrate Preparation and Primer Guide. Mixing PRIMER is a concentrate and must be diluted with clean potable water. Dilution ratio varies depending on the substrate. Mix/stir concentrate thoroughly prior to diluting PRIMER DILUTION / APPROXIMATE COVERAGE SUITABLE SUBSTRATES Dilution Ratio = Primer : Water Normal Suction: Concrete High-Suction: Highly Porous Dry Concrete / LATICRETE Underlayments / Cement Mortar Beds Exterior Glue Plywood Non-Suction: Ceramic, Stone, Quarry Tile / VCT, Sheet Vinyl / Cement Terrazzo LATICRETE Vapour Reduction Coating 1:3 1st coat: 1:5 2nd coat: 1:3 1:3 1:1 with slurry 1:1 with slurry Approximate Coverage Per 5 Litres of Concentrate Diluted with Water 48m2 25m2 48m2 25m2 25m2 * PRIMER is sold as a concentrate. To estimate quantity of primer for a job, select the type of SUITABLE SUBSTRATE from the table, then look up the concentrate diluted with water. Application For proper application instructions refer to TDS 1230 Substrate Preparation and Primer Guide. Field visits by LATICRETE personnel are for the purpose of making technical recommendations only and not for supervising or providing quality control on the job site. Cleaning All tools and equipment should be cleaned promptly with water. AVAILABILITY AND COST Availability LATICRETE and LATAPOXY® materials are available worldwide. For Distributor information: Toll Free: 1800 331 012 Telephone: 07 3865 1599 For online distributor information, visit LATICRETE at www.laticrete.com.au Cost Contact a LATICRETE Distributor in your area. ©2022 LATICRETE Australia Pty Ltd | www.laticrete.com.au | All trademarks shown are the intellectual properties of their respective owners. 2 Data Sheets are subject to change without notice. For latest revision, visit www.laticrete.com.au DS-1236-0922 MAINTENANCE LATICRETE® and LATAPOXY® grouts, sealers and sealants require routine maintenance and cleaning with a neutral pH detergent and water. See TDS 1113 for more information. All other LATICRETE and LATAPOXY non-finish materials require no maintenance but installation performance and durability may depend on properly maintaining products supplied by other manufacturers. TECHNICAL SERVICES Technical assistance Information is available by calling: Toll Free: 1800 331 012 Telephone: 07 3865 1599 Fax: 07 3865 2250 Technical and safety literature To acquire technical and safety literature, please visit our website at www.laticrete.com.au DISCLAIMER § The information contained in this document is given in good faith and to the best of our knowledge is true and accurate. § This information is subject to change without notice and it is the responsibility of the user to obtain up to date and current information. § The use of this product is beyond our control and liability is assumed by the user when used incorrectly and not in accordance with LATICRETE guidelines. § Efflorescence is a normal condition of Portland cement and is not covered by any warranty. The use of LATAPOXY 310 Stone Adhesive, LATAPOXY 300 Adhesive, SPECTRALOCK® PRO Premium Grout and SPECTRALOCK 2000 IG will not contribute to any noticeable efflorescence. LATICRETE Australia Pty Ltd 29 Telford Street, Virginia QLD 4014 Australia 1800 331 012 www.laticrete.com.au ©2022 LATICRETE Australia Pty Ltd | www.laticrete.com.au | All trademarks shown are the intellectual properties of their respective owners. 3 Data Sheets are subject to change without notice. For latest revision, visit www.laticrete.com.au