User Guide for SHURE models including: AD3, Plug-On Transmitter
• Battery packs may explode or release toxic materials. Risk of fire or burns. Do not open, crush, modify, disassemble, heat above 140°F (60°C), or incinerate. • Follow instructions.. View
AD3 Plug-On Transmitter User guide for the AD3 Axient Digital plug-on transmitter. Version: 3.1 (2022-A)
User Guides
File Info : application/pdf, 26 Pages, 977.12KB
DocumentDocumentAD3 Plug-On Transmitter User guide for the AD3 Axient Digital plug-on transmitter. Version: 3.1 (2022-A) Shure Incorporated Table of Contents AD3 Plug-On Transmitter 3 WARNING 3 AD3 Axient Digital Plug-On Transmitter 3 Features 4 Included Components 4 Optional Accessories 4 AD3 Transmitter Overview 4 Setup 6 Setting the AA Battery Type 7 Shure Rechargeable Battery 7 Power Over USB 8 Important Tips for Care and Storage of Shure Recharge able Batteries 8 AA Batteries and Transmitter Runtime 8 Transmitter Controls 9 Menu Overview 10 Menu Map 10 Tips for Editing Menu Parameters 10 Home Screen Display 10 Locking the Interface 11 IR Sync 11 Setting the Frequency Manually 11 Updating Firmware 12 Firmware Versioning 12 Updating the Transmitter 12 RF Mute 12 Safe Start 13 Input Overload 13 Tone Generator 14 Matching Audio Levels with Offset 14 Menu Item Descriptions 14 Radio Menu 15 Audio Menu 15 Utilities Menu 16 Troubleshooting 16 Power 17 Gain 17 Cables 17 Interface Locks 17 Encryption Mismatch 17 Firmware Mismatch 17 Tx Battery Hot 17 Radio Frequency (RF) 18 Clean Battery Contacts 19 Contact Customer Support 19 Specifications 19 Frequency Range and Transmitter Output Level 21 LICENSING INFORMATION 24 Australia Warning for Wireless 24 Certifications 24 Information to the user 25 2/26 Shure Incorporated AD3 Plug-On Transmitter WARNING · Battery packs may explode or release toxic materials. Risk of fire or burns. Do not open, crush, modify, disassemble, heat above 140°F (60°C), or incinerate. · Follow instructions from manufacturer · Only use Shure charger to recharge Shure rechargeable batteries · WARNING: Danger of explosion if battery incorrectly replaced. Replace only with same or equivalent type. · Never put batteries in mouth. If swallowed, contact your physician or local poison control center · Do not short circuit; may cause burns or catch fire · Do not charge or use battery packs other than Shure rechargeable batteries · Dispose of battery packs properly. Check with local vendor for proper disposal of used battery packs. · Batteries (battery pack or batteries installed) shall not be exposed to excessive heat such as sunshine, fire or the like · Do not immerse the battery in liquid such as water, beverages, or other fluids. · Do not attach or insert battery with polarity reversed. · Keep away from small children. · Do not use abnormal batteries. · Pack the battery securely for transport. WARNING If water or other foreign objects enter the inside of the device, fire or electric shock may result. Do not attempt to modify this product. Doing so could result in personal injury and/or product failure. CAUTION Never disassemble or modify the device, as failures may result. Do not subject to extreme force and do not pull on the cable or failures may result. Keep the microphone dry and avoid exposure to extreme temperatures and humidity. Note: Use only with the included power supply or a Shure-approved equivalent. AD3 Axient Digital Plug-On Transmitter The Shure AD3 plug-on transmitter transforms any microphone into an advanced, portable Axient Digital AD Series wireless microphone, delivering impeccable audio quality and RF performance, wide-tuning, and encryption features. Compatible with Axient Digital AD4D and AD4Q receivers in Standard or High Density modes, AD3 features a custom, fast, and secure XLR connector design, support for both conventional AA and Shure SB900-series rechargeable battery options, and simple, userfriendly controls and menus. The AD3 is housed in a lightweight, rugged, metal chassis and is designed to resist sweat, mois ture, and debris. 3/26 Shure Incorporated Features Performance · 20 Hz to 20 kHz range with flat frequency response · Automatic input staging optimizes gain setting · AES 256-bit encryption-enabled for secure transmission · >120 dB dynamic range · 100 meter (300 feet) line-of-sight operating range · Selectable modulation modes optimize performance for spectral efficiency Standard optimal coverage, low latency High density dramatic increase in max system channel count · Built-in tone generator and RF markers to facilitate walk-testing · Switchable Power Levels = 2/10/35 mW (region dependent) Design · Locking XLR connector · OLED display with easy-to-navigate menu and controls · Rugged metal construction · Menu and power lockout Power · Over 8 hours continuous use with Shure rechargeable battery · Shure lithium-ion rechargeable battery provides extended battery life, precision metering, and zero memory effect · External power and charging over USB-C Included Components AA alkaline batteries (2) USB-A to USB-C cable Zipper bag Pouch with belt clip 80B8201 95A39299 95D2313 95A44910 Optional Accessories SB900B rechargeable lithium-ion battery SB900B AD3 Transmitter Overview Display 4/26 Shure Incorporated View menu screens and settings. Press any control button to activate the backlight. Infrared (IR) port Align with the receiver IR port during an IR Sync for automated transmitter tuning and setup. Control buttons Use to navigate through parameter menus and to change settings. Power switch Hold the X button to power the unit on or off. Enter button Press to enter menu screens and confirm menu changes. Power LED Green = Unit is powered on Red = Low battery, or battery error Audio LED Red, yellow, and green LEDs indicate average and peak audio levels. The LED will turn red when the limiter is engaged. USB-C port Supplies power or charges Shure rechargeable battery. LED indicates charging status when connected to a power supply. Red = Charging Green = Full charge Yellow = Not charging Battery compartment Requires two AA batteries or Shure rechargeable battery. AA battery adapter Use to secure AA batteries. Remove when using a Shure rechargeable battery. XLR connector Connection point for wired microphones, cables, and boom poles, among other things. Locking ring To release the XLR connector, turn the ring counterclockwise and push in. Pouch Provides additional grip and protection for the transmitter. Belt clip 5/26 Holds transmitter and microphone securely for hands-free carrying. Shure Incorporated Setup 1. Slide the tab on the side of the transmitter to open the battery door. 2. Install the batteries. AA batteries: Place batteries (note polarity markings) and AA adapter as shown below and close the door. Shure rechargeable battery: Place battery as shown below (note polarity markings). Remove the AA adapter and close the door to secure the battery. Note: If using AA batteries, set the battery type to ensure the transmitter's battery status indicator is accurate. 3. Press and hold X to turn on the transmitter. 6/26 Shure Incorporated 4. Select the appropriate input pad or boost to avoid overloading the audio input our add boost to low-output sources: Au dio > Pad 12dB: Use with high output sources, such as line levels and point-to-point applications. Off (default): Use with typical microphones. +12dB: Use with low output sources. 5. Plug the transmitter into an XLR microphone or the output of an audio device. Note: If you remove or replace the batteries without turning the transmitter off, the device will turn on again when the batteries are replaced. Setting the AA Battery Type To ensure accurate display of transmitter runtime, set the battery type to match the battery you have installed. Note: If a Shure rechargeable battery is installed, selecting a battery type is not necessary and the battery type will display Shure. 1. Navigate to Utilities and select Battery. 2. Use the buttons to select the installed battery type: Alkaline = Alkaline NiMH = Nickel Metal Hydride Lithium = Lithium Primary 3. Press O to save. Shure Rechargeable Battery Shure SB900series lithiumion batteries offer a rechargeable option for powering the transmitters. Batteries charge to 50% ca pacity in 1 hour and reach full charge within 3 hours. Single chargers and multiple bay chargers are available to recharge the Shure batteries. Caution: Only charge Shure rechargeable batteries with a Shure battery charger. Shure SB900B Runtime 2 mW 8+ hours 10 mW 8+ hours 35 mW 5+ hours Note: Phantom power, RF output and the impedance of the connecting device can impact battery life. Checking Battery Info When using a Shure rechargeable battery, the receiver and transmitter home screens display the number of hours and minutes remaining. Detailed information for the battery is displayed Battery menu of the transmitter: Utilities > Battery · Battery: The chemistry type of for the installed battery (Shure, Alkaline, Lithium, NiMH) · BatteryTimetoFull (only appears when Shure rechargeable battery is being externally charged): Time remaining until bat tery is fully charged · BatteryLife: Indicates remaining battery runtime 7/26 · Charge: Percentage of charge capacity · Health: Percentage of current battery health · CycleCount: Total of the number of charging cycles for the installed battery · Temperature: Battery temperature reported in Celsius and Fahrenheit Shure Incorporated Power Over USB When operated with AA batteries, or without batteries, the AD3 transmitter can be powered by connecting the USB-C port on the bottom of the transmitter to a suitable power source. When a Shure rechargeable battery is inserted, the USB connection can power the transmitter while simultaneously charging the battery. Important Tips for Care and Storage of Shure Rechargeable Batteries Proper care and storage of Shure batteries results in reliable performance and ensures a long lifetime. · Always store batteries and transmitters at room temperature · Ideally, batteries should be charged to approximately 40% of capacity for long-term storage · Periodically clean the battery contacts with alcohol to maintain ideal contact · During storage, check batteries every 6 months and recharge to 40% of capacity as needed For additional rechargeable battery information, visit www.shure.com. Note: A Battery Hot warning indicates that transmitter battery needs to cool off. Otherwise, the transmitter will shut down. Let the device cool down and then consider swapping the transmitter battery to continue operation. Identify any possible external heat sources to the transmitter and operate the transmitter away from those external heat sources. All batteries should be stored and operated away from external heat sources in reasonable temperature conditions for best performance. AA Batteries and Transmitter Runtime Transmitters are compatible with the following AA battery types: · Alkaline · Nickel Metal Hydride (NiMH) · Lithium Primary A 5segment battery indicator representing the charge level of the transmitter battery is displayed on the screens of the trans mitter and receiver. The following table contains the approximate remaining transmitter runtime in hours:minutes. 8/26 Alkaline Batteries Battery Runtime (hours:minutes) Battery Indicator UHF 2 mW/10 mW 8:00 to 6:00 1.x 35 mW 3:30 to 3:00 2 mW /10 mW 30 mW 3:45 5:30 to to 4:15 3:00 3:00 3:00 4:15 to 6:00 to 4:00 to to 3:00 2:00 2:15 2:00 2:15 3:00 to 4:00 to 1:45 to to 1:45 1:30 2:00 <1:45 <1:30 <1:45 <2:00 <0:45 <0:45 <0:45 <0:45 <0:15 <0:15 <0:15 <0:15 Transmitter Controls Use the controls to navigate menus and update settings. Shure Incorporated Hold button to turn transmitter power on and off. Acts as a 'back' button to return to previous menus or pa X rameters without confirming a value change. O Enters menu screens and confirms parameter changes Use to scroll through menu screens and to change parameter values Tip: Hold the button while powering on to enter safe start mode. 9/26 Menu Overview Menu Map Shure Incorporated Tips for Editing Menu Parameters · To access the menu options from the home screen, press O. Use the arrow buttons to see additional menus and parame ters. · A menu parameter will blink when editing is enabled · To increase, decrease, or change a parameter, use the arrow buttons · To save a menu change, press O · To exit a menu without saving a change, press X Home Screen Display The home screen shows transmitter information and status. There are four pieces of information that you can choose to see on the home screen. Use the arrow buttons to select one of the following choices: Name Frequency Setting Group (G) and Channel (C) Device ID The following icons indicate transmitter settings: Battery runtime in hours and minutes or bar display Key: Displayed when encryption is enabled 10/26 Shure Incorporated Lock: Displayed when controls are locked. Icon flashes if you attempt to access a locked control (power or menu). STD: Standard Transmission Mode HD: High Density Transmission Mode Locking the Interface Lock transmitter interface controls to prevent accidental or unauthorized changes to parameters. The lock icon appears on the home screen when a lock is enabled. 1. From the Utilities menu, navigate to Locks and select one of the following lock options: None: The controls are unlocked Power: The power switch is locked Menu: The menu parameters are locked All: The power switch and menu parameters are locked 2. Press O to save. Tip: To quickly unlock the transmitter menu, press O and select None. IR Sync Use IR Sync to form an audio channel between the transmitter and receiver. Note: The receiver band must match the band of the transmitter. 1. Select a receiver channel. 2. Tune the channel to an available frequency using group scan or manually turn to an open frequency. 3. Power on the transmitter. 4. Press the SYNC button on the receiver. 5. Align the IR windows between the transmitter and the receiver so that the IR LED illuminates red. When complete, SyncSuccess! appears. The transmitter and receiver are now tuned to the same frequency. Note: Any change to the encryption status on the receiver (enabling/disabling encryption) requires a sync to send the settings to the transmitter. New encryp tion keys for the transmitter and receiver channel are generated on every IR sync, so to request a new key for a transmitter, perform an IR sync with the de sired receiver channel. 11/26 Shure Incorporated Setting the Frequency Manually The transmitter can be manually tuned to a specific group, channel, or frequency. 1. Navigate to the Radio menu and select Freq. 2. Scroll to select G: and C: to edit the group and channel, or select the frequency parameter (MHz). When editing the fre quency, press O once to edit the first 3 digits, or twice to edit the last 3 digits. 3. Use the buttons to adjust the group, channel, or frequency. 4. Press O to save, and then press X when finished. Updating Firmware Firmware is embedded software in each component that controls functionality. Periodically, new versions of firmware are devel oped to incorporate additional features and enhancements. To take advantage of design improvements, you can upload and in stall new versions of the firmware by using the Shure Update Utility. The Shure Update Utility is available for download from http://www.shure.com/. Firmware Versioning When performing an update, first download firmware to the receiver, and then update transmitters to the same firmware version to ensure consistent operation. The firmware numbering for Shure devices uses the following format: MAJOR.MINOR.PATCH.BUILD (e.g., 1.2.21.1). At a mini mum, all devices on the network (including transmitters), must have the same MAJOR and MINOR firmware version numbers (e.g., 1.2.x). Updating the Transmitter 1. Download the firmware to the receiver. 2. Access the following menu from the receiver: DeviceSettings > TxFirmwareUpdate. 3. Align the IR ports between the transmitter and the receiver. IR ports must be aligned for the entire download, which can take 50 seconds or longer. Tip: The red alignment LED will turn on when the alignment is correct. 4. Press ENTER on the receiver to begin the download to the transmitter. The receiver will display the progress of the up date as a percentage. RF Mute RF mute prevents transmission of the audio by suppressing the RF signal while the transmitter remains powered-on. The home screen displays RFMuted in this mode. 12/26 Shure Incorporated 1. From the Radio menu, navigate to Output. 2. Choose one of the following options: On: RF signal is active Mute: RF signal is disabled 3. Press O to save. Note: Turning the transmitter off and on or replacing the battery will restore Output to On. Safe Start Power on in safe start mode to prevent interference with other devices. Hold the ^ button while powering on your device until the Safe Start menu appears. Safe Start menu options: · RF: Mute or On · Locks: None, Pwr, Menu, All · Phantom: Off, +12V, +48V Use the navigation buttons to make changes. Tip: To exit the Safe Start menu, push X. Note: Previous settings for locks, RF, and phantom power will be retained when the transmitter is powered on in safe start mode. Input Overload The TxOverload message appears when the audio input experiences a highlevel signal. The audio LED turns red as an addi tional indicator of an overload. Reduce the input signal or enable the input pad to remove the overload condition. Tip: To enable the input pad, navigate to Audio > Pad and select 12dB. 13/26 Shure Incorporated Tone Generator The transmitter contains an internal tone generator that produces a continuous audio signal. The tone is helpful when conduct ing a sound check or for troubleshooting the audio signal chain. The level of the tone is adjustable from -60 dB to 0 dB and the frequency can be set to 400 Hz or 1000 Hz. Tip: Always start with the level set to -60 dB to avoid overloading speakers or headphones. 1. From the Audio menu select ToneGen. 2. Set the frequency to 400Hz or 1000Hz. 3. Select Level and use the arrow buttons adjust the value between -60 dB and 0 dB. Turn off the tone by selecting Off from the menu or by cycling the transmitter power. Matching Audio Levels with Offset When linking two or more transmitters to a receiver, there may be a difference in volume levels between microphones or instru ments. If this occurs, use the Offset function to match the audio levels and eliminate audible volume differences between trans mitters. If using a single transmitter, set Offset to 0 dB. 1. Turn on the first transmitter and perform a sound check to test the audio level. Turn off the transmitter when finished. 2. Turn on the second transmitter and perform a sound check to test the audio level. Repeat for any additional transmit ters. 3. If there is an audible difference in the sound level between the transmitters, navigate to the Offset menu (Audio > Offset) in the transmitter to increase or decrease the Offset in realtime to match the audio levels. 14/26 Shure Incorporated Menu Item Descriptions Radio Menu Freq Press the O button to enable editing of a group (G:) channel (C:) or frequency (MHz). Use the arrow buttons to adjust the values. To edit the frequency, press the O button once to edit the first 3 digits, or twice to edit the second 3 digits. Power Higher RF power settings can extend the range of the transmitter. Note: Higher RF power settings decrease battery runtime. Output Sets the RF output to On or Mute. On: RF signal is active Mute: RF signal is inactive Audio Menu Phantom Adds phantom power for condenser microphones. Select +12V or +48V as required by the microphone. Input Pad/Boost Adjust the pad to avoid overloading the audio input or add a boost to lowoutput sources. Choose between 12 dB, Off (de fault), and +12dB. 12dB: Use with high output sources, such as line levels and point-to-point applications. Off (default): Use with typical microphones. +12dB: Use with low output sources. HP Filter High-pass filter. Scroll up to turn on the filter and set the low-frequency rolloff in Hz; scroll all the way down to turn off. Range: 40 Hz to 240 Hz. Polarity Selectable polarity assignment for the audio input connector: Pos: Positive pressure on microphone diaphragm produces positive voltage on pin 2 (with respect to pin 3 of XLR output) and the tip of the TRS output on the receiver. Neg: Positive pressure on microphone diaphragm produces negative voltage on pin 2 (with respect to pin 3 of XLR output) and the tip of the TRS output on the receiver. Offset Adjust Offset level to balance mic levels when using two transmitters or when assigning multiple transmitters to receiver slots. Adjustment range: -12 dB to +21 dB. ToneGen 15/26 Shure Incorporated Tone generator. Transmitter will generate a continuous test tone: Freq: The tone can be set to 400 Hz or 1000 Hz. Level: Adjusts the output level of the test tone. Utilities Menu DeviceID Assign a device ID of up to 8 characters. Locks Locks the transmitter controls and power switch. None: The controls are unlocked Power: The power switch is locked Menu: The menu parameters are locked All: The power switch and menu parameters are locked Marker When enabled, press O to drop a marker in Wireless Workbench. Battery Displays battery information: BatteryLife: Runtime reported in bar display and time (hours:minutes) BatteryTimetoFull(only appears when Shure rechargeable battery is being externally charged): Time remaining until bat tery is fully charged Charge: Percentage of charge capacity Health: Percentage of current battery health CycleCount: Total of the number of charging cycles for the installed battery Temperature: Battery temperature reported in Celsius and Fahrenheit About Displays the following transmitter information: Model: Displays the model number Band: Displays the tuning band of the transmitter FWVersion: Installed firmware HWVersion: Hardware version SerialNum: Serial number ResetAll Restores all transmitter parameters to factory settings. 16/26 Shure Incorporated Troubleshooting Issue No sound See Solution... Power, Cables, Radio Frequency, or Encryp tion Mismatch Faint sound or distortion Gain, Cables Lack of range, unwanted noise bursts, or dropouts Radio Frequency (RF) Cannot turn transmitter off or change frequency settings, or can't program receiver Interface Locks Encryption Mismatch message Encryption Mismatch Firmware Mismatch message Firmware Mismatch Transmitter Battery Hot message Tx Battery Hot Antenna Fault Red LED RF Handheld transmitter shuts down during use Clean Battery Contacts Power Make sure that the receiver and transmitter are receiving sufficient voltage. Check the battery indicators and replace the trans mitter batteries if necessary. Gain Adjust the system gain on the front of the receiver. Ensure the output level on the back of the receiver corresponds to the mic/ line input setting of the mixing console, amplifier, or DSP. Cables Check that all cables and connectors are working correctly. Interface Locks The transmitter and the receiver can be locked to prevent accidental or unauthorized changes. A locked feature or button will produce the Locked screen on the LCD panel or the lock icon will flash on a transmitter. Encryption Mismatch Re-sync all receivers and transmitters after enabling or disabling encryption. Firmware Mismatch Paired transmitters and receivers must have the same firmware version installed to ensure consistent operation. See Firmware topic for firmware update procedure. Tx Battery Hot If the transmitter battery does not cool off, the transmitter will shut down. Let the device cool down and then consider swapping the transmitter battery to continue operation. 17/26 Shure Incorporated Identify any possible external heat sources to the transmitter and operate the transmitter away from those external heat sources. All batteries should be stored and operated away from external heat sources in reasonable temperature conditions for best performance. Radio Frequency (RF) RF LEDs If neither blue RF Diversity LED is illuminated, then the receiver is not detecting the presence of a transmitter. The orange RF Signal Strength LEDs indicate the amount of RF power being received. This signal could be from the transmit ter, or it could be from an interfering source, such as a television broadcast. If more than two of the orange RF LEDs are still illuminated while the transmitter is off, then that channel may be experiencing interference, and you should try a different channel. The red RF LED indicates RF overload. Overloads have the potential to cause interference in multiple system installations. If you are experiencing an overload, turn off the receiver to see if it is causing interference with other components. The numerical channel select button also turns red to indicate interference. · Dim red = Channel is not selected, experiencing interference · Bright red = Channel is selected, experiencing interference Compatibility · Perform a Scan and Sync to ensure the transmitter and receiver are set to the same group and channel. · Look at the band label on the transmitter and make sure the receiver is set to the same band. Reducing Interference · Perform a group or channel scan to find the best open frequency. Perform a sync to transfer the setting to the transmitter. · For multiple systems, check that all systems are set to channels in the same group (systems in different bands do not need to be set to the same group). · Maintain a line of sight between transmitter and receiver antennas. · Move or point receiver antennas away from metal objects or other sources of RF interference (such as LED walls, comput ers, digital effects, network switches, network cables and Personal Stereo Monitor (PSM) wireless systems). · Eliminate RF overload (see below). Increasing Range If the transmitter is more than 6 to 60 m (20 to 200 ft) from the receiver antenna, you may be able to increase range by doing one of the following: · Reduce interference (see above). · Increase transmitter RF power level. · Use Normal mode instead of High Density mode. · Use an active directional antenna, antenna distribution system, or other antenna accessory to increase RF range. 18/26 Shure Incorporated Eliminating RF Overload If you see the red RF LED on a receiver, try the following: · Reduce the transmitter RF power level · Move the transmitter further away from the receiver--at least 6 m (20 ft) · If you are using active antennas, reduce antenna or amplifier gain. · Use omnidirectional antennas Antenna Faults The AntennaFault red LED indicates a short circuit condition or excessive load at an antenna port. · Check antennas and cables for damage · Ensure that antenna ports are not overloaded · Check antenna bias voltage setting. Turn off voltage if using passive antennas. Clean Battery Contacts Clean the battery contacts with an electrical contact cleaner designed for gold contacts and safe on plastics. Contact Customer Support Didn't find what you need? Contact our customer support to get help. Specifications Mic Offset Range 12 to 21 dB (in 1 dB steps) Battery Type Shure SB900 series Rechargeable LiIon or LR6 AA batteries 1.5 V Battery Runtime @ 10 mW Shure SB900B > 8 hours alkaline > 7 hours Dimensions 126 mm x 44.5 mm x 44.5 mm (5.0in. x 1.8in. x 1.8 in.) H x W x D Weight Without Battery with AA batteries with Shure rechargeable battery 240 g (8.0 oz.), 263 g 280 g 19/26 Shure Incorporated Housing Cast Metal Operating Temperature Range -10°C (-14°F) to 50°C (122°F) Note: Battery characteristics may limit this range. Storage Temperature Range -40°C (-40°F) to 74°C (165°F) Note: Battery characteristics may limit this range. Audio Input Connector 3-pin female XLR Configuration balanced Impedance Pad-12 dB 0 dB Boost12 dB Maximum Input Level 1 kHz at 1% THD Pad-12 dB 0 dB Boost12 dB Preamplifier Equivalent Input Noise (EIN) System Gain Setting +20 115 dBV, Aweighted, typical 26.64 k 6.64 k 6.64 k 21 dBV 9 dBV 3 dBV Phantom Power +48 V(7 mA maximum) , +12 V(15 mA maximum) High Pass Filter Two-pole (12 dB per octave), cut off frequency selectable from 40 to 240 in 20 Hz increments 20/26 Shure Incorporated RF Output Antenna Type Dipole Impedance 50 Occupied Bandwidth <200 kHz Channel-to-Channel Spacing Standard Mode 350 kHz High Density Mode 125 kHz varies by region Modulation Type Shure Axient Digital Proprietary Power 2 mW, 10 mW, 35 mW See Frequency Range and Output Power table, varies by region Specific Absorption Rate (SAR) < 0.12 W/kg Frequency Range and Transmitter Output Level Band Frequency Range ( MHz) RF Power ( mW)*** G53 470 to 510 2/10/35 G54 479 to 565 2/10/20 G55 470 to 636* 2/10/35 G56 470 to 636 2/10/35 G57 470 to 616* 2/10/35 G62 510 to 530 2/10/35 G63 H54 K53 K54 487 to 636 520 to 636 606 to 698* 606 to 663** 2/10 2/10/35 2/10/35 2/10/35 21/26 Shure Incorporated Band K55 Frequency Range ( MHz) 606 to 694 RF Power ( mW)*** 2/10/35 K56 606 to 714 2/10/35 K57 606 to 790 2/10/35 K58 622 to 698 2/10/35 L54 630 to 698 2/10/35 L60 630.125 to 697.875 2/10/35 P55 694 to 703, 748 to 758, 803 to 806 2/10/35 R52 794 to 806 2/10 JB 806 to 810 2/10 X51 925 to 937.5 2/10 X55 941 to 960 2/10/35 X56 960 to 1000 2/10/35 *With a gap between 608 to 614 MHz. **With a gap between 608 to 614 MHz and a gap between 616 to 653 MHz. ***Power delivered to the antenna port. Operation mode varies according to region. In Brazil, High Density mode is used. The maximum power level for Peru is 10mW. Limited to 10mW for Vietnam. Only in UK; F-variant only. Output power limited to 10 mW above 608 MHz. Korea defines power as conducted (ERP) which is 1dB less then declared in table. . 22/26 Shure Incorporated K55 606-694 MHz Country Code Code de Pays Codice di paese Código de país Länder-Kürzel Frequency Range Gamme de frequences Gamme di frequenza Gama de frequencias Frequenzbereich A, B, BG, CH, CY, CZ, D, DK, EST, F * FIN, GB, GR, H, HR, I, IRL, IS, L, LT * M, N, NL, P, PL, RO, S, SK, SLO, TR * all other countries * * This equipment may be capable of operating on some frequencies not authorized in your region. See Licensing Information. G56 470-636 MHz Country Code Code de Pays Codice di paese Código de país Länder-Kürzel Frequency Range Gamme de frequences Gamme di frequenza Gama de frequencias Frequenzbereich A, B, BG, CH, CY, CZ, D, DK, EST, F * FIN, GB, GR, H, HR, I, IRL, IS, L, LT * M, N, NL, P, PL, RO, S, SK, SLO, TR * all other countries * * This equipment may be capable of operating on some frequencies not authorized in your region. See Licensing Information. 23/26 Shure Incorporated K57 606-790 MHz Country Code Code de Pays Codice di paese Código de país Länder-Kürzel Frequency Range Gamme de frequences Gamme di frequenza Gama de frequencias Frequenzbereich A, B, BG, CH, CY, CZ, D, DK, EST, F * FIN, GB, GR, H, HR, I, IRL, IS, L, LT * M, N, NL, P, PL, RO, S, SK, SLO, TR * all other countries * * This equipment may be capable of operating on some frequencies not authorized in your region. See Licensing Information. LICENSING INFORMATION Licensing: A ministerial license to operate this equipment may be required in certain areas. Consult your national authority for possible requirements. Changes or modifications not expressly approved by Shure Incorporated could void your authority to operate the equipment. Licensing of Shure wireless microphone equipment is the user's responsibility, and licensability de pends on the user's classification and application, and on the selected frequency. Shure strongly urges the user to contact the appropriate telecommunications authority concerning proper licensing, and before choosing and ordering frequencies. Australia Warning for Wireless This device operates under an ACMA class licence and must comply with all the conditions of that licence including operating frequencies. Before 31 December 2014, this device will comply if it is operated in the 520-820 MHz frequency band. WARNING: After 31 December 2014, in order to comply, this device must not be operated in the 694-820 MHz band. No useroperated control of power, frequency, or other parameters are available beyond those specified in this operating man ual. Please follow your regional recycling scheme for batteries, packaging, and electronic waste. Certifications Certified under FCC Part 15 and FCC Part 74. Certified by ISED in Canada under RSS-210. FCC ID: DD4AD3G57, DD4AD3K54, DD4AD3X55. IC: 616A-AD3G57, 616A-AD3K54. Meets essential requirements of the following European Directives: · WEEE Directive 2012/19/EU, as amended by 2008/34/EC · RoHS Directive EU 2015/863 24/26 Shure Incorporated Note: Please follow your regional recycling scheme for batteries and electronic waste This product meets the Essential Requirements of all relevant European directives and is eligible for CE marking. CE Notice: Hereby, Shure Incorporated declares that this product with CE Marking has been determined to be in compliance with European Union requirements. The full text of the EU declaration of conformity is available at the following site: https:// www.shure.com/en-EU/support/declarations-of-conformity. Authorized European representative: Shure Europe GmbH Department: Global Compliance Jakob-Dieffenbacher-Str. 12 75031 Eppingen, Germany Phone: +49-7262-92 49 0 Fax: +49-7262-92 49 11 4 Email: EMEAsupport@shure.de "" ISM Information to the user This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: 1. This device may not cause harmful interference. 2. This device must accept any interference received, including interference that may cause undesired operation. Note: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installa tion. This equipment generates uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures: · Reorient or relocate the receiving antenna. · Increase the separation between the equipment and the receiver. · Connect the equipment to an outlet on a circuit different from that to which the receiver is connected. · Consult the dealer or an experienced radio/TV technician for help. Canada Warning for Wireless This device operates on a noprotection, nointerference basis. Should the user seek to obtain protection from other radio ser vices operating in the same TV bands, a radio licence is required. For further details, consult Innovation, Science and Econom ic Development Canada's document Client Procedures Circular CPC2128, Voluntary Licensing of LicenceExempt LowPow er Radio Apparatus in the TV Bands. 25/26 Shure Incorporated Ce dispositif fonctionne selon un régime de nonbrouillage et de nonprotection. Si l'utilisateur devait chercher à obtenir une certaine protection contre d'autres services radio fonctionnant dans les mêmes bandes de télévision, une licence radio serait requise. Pour en savoir plus, veuillez consulter la Circulaire des procédures concernant les clients CPC2128, Délivrance de licences sur une base volontaire pour les appareils radio de faible puissance exempts de licence et exploités dans les bandes de télévision d'Innovation, Sciences et Développement économique Canada. This device operates on frequencies shared with other devices. Consult the Federal Communications Commission White Space Database Administration website to determine available channels in your area prior to operation. This device contains licenceexempt transmitter(s)/receiver(s) that comply with Innovation, Science and Economic Develop ment Canada's licenceexempt RSS(s). Operation is subject to the following two conditions: 1. This device may not cause interference. 2. This device must accept any interference, including interference that may cause undesired operation of the device. L'émetteur/récepteur exempt de licence contenu dans le présent appareil est conforme aux CNR d'Innovation, Sciences et Développement économique Canada applicables aux appareils radio exempts de licence. L'exploitation est autorisée aux deux conditions suivantes : 1. L'appareil ne doit pas produire de brouillage; 2. L'appareil doit accepter tout brouillage radioélectrique subi, même si le brouillage est susceptible d'en compromettre le fonctionnement. 26/26