Melissani M1 Reverse Osmosis Water Purifier
Operating Manual
Welcome to Melissani
Welcome to Melissani, where our passion for pure water is deeply rooted in the inspiration we draw from the pristine Melissani Cave (Μελισσάνη) in Greece. Renowned for its crystal-clear, naturally pure water, the Melissani Cave serves as a symbol of our commitment to providing the highest quality water purification solution for your home.
Our premium Melissani M1 Countertop Reverse Osmosis Water Purifier is a testament to this dedication, designed to bring the essence of Melissani's purity to your kitchen. We are proud to offer a product that not only delivers exceptional performance but also embodies the true spirit of our namesake, ensuring that every drop of water you consume is as pure and refreshing as nature intended.
Thank you for choosing Melissani, and we hope you enjoy the unparalleled quality of the water our purifiers provide.
Contact: contact@melissaniwater.com | Phone: 813-328-6390
Before Use
- Hold Power for 2 seconds to turn on.
- Fill Tap Water tank.
- Press and hold Clean for 3 seconds to flush the system and filters (takes 6 minutes).
- Make sure to have a large container under the water dispenser, or have the dispense nozzle positioned over your sink.
- Empty Wastewater tank and refill Tap Water tank.
- Repeat this cleaning cycle 3 times before using M1.
- M1 is ready to make clean, crisp water.
Specifications
- Model: M1
- Capacity: 1.5 Gallons (6 Liters)
- Flow Rate: 14 oz per minute (400ml)
- Dimensions: 19 x 9.5 x 17"
- Weight: 24 lbs
- Rated Voltage: 110V
- Rated Power: 1500W
- Power Consumption: 0.1 kW/day
- Power Cord Length: 6 feet (186cm)
- Working Pressure: 0.4 - 0.6 MPa (58 - 87 psi)
- Water Source: City (Tap) or Well
Diagram
The Melissani M1 features a display panel, dispense nozzle, and a transparent window. It includes a water tank cover, water tank, purified water compartment, and a drip tray.
Functions
Icon/Button | Action | Description |
---|---|---|
Power | Hold for 2 seconds | Power on/off. |
Clean | Hold 3 seconds | Initiate deep cleaning cycle (6 minutes). Cleans waterways and filters. |
Reset | Hold for 3 seconds after replacement | Reset filter life indicators. Hold Reset key for 3 seconds, then use it again to select filter (1, 2, or 3). |
Purify | On when purifying | Indicator light is on when purifying water. Flashes when cleaning. |
Add Water | Refill water tank/empty waste water tank | Indicates when to refill the water tank or empty the waste water tank. |
Error | Unit is warming up | Indicates the unit is warming up. |
Filter Life | Cold water is on | Indicates cold water is on. |
TDS | Room temp water | Indicates room temperature water. |
PPB | Hot water | Indicates hot water. |
H2 | Initiate Hydrogen production | Initiates Hydrogen production in purified water. |
8oz | Dispense 8 oz. | Dispenses 8 ounces of water. |
12oz | Dispense 12 oz. | Dispenses 12 ounces of water. |
Normal | Dispense continuously | Dispenses room temperature water continuously (up to 1 liter). |
Cold | Dispense Cold water | Dispenses cold water (approx. 46 degrees F.). |
Hot | Dispense Hot water | Dispenses hot water (approx. 203 degrees F). To adjust temperature, hold “Hot” for 3 seconds, then press "12 oz" & "8 oz” to adjust temperature up or down. |
Reset + Clean | Hold simultaneously | Drains all internal water. |
Operation
STEP 1
Place water purifier on a flat surface. Plug in.
Diagram: Shows the water purifier unit.
STEP 2
Remove the water tank, fill the tap water tank with fresh tap water, install the water tank on the purifier, and close the lid of the water tank.
Diagram: Illustrates removing and filling the water tank, with markings for water levels (MAX, 3L, 2L).
STEP 3
Plug in the purifier and hold the power key for 2-3 seconds to power on the purifier.
Diagram: Shows the purifier with the power button highlighted.
STEP 4
To achieve optimal water quality, it is recommended to clean the purifier manually by holding the “Clean Key" for 3 seconds. Make sure to either place a large container under the nozzle, or position nozzle over a sink, in order to drain the water being flushed through the system.
Diagram: Shows the purifier with the clean button highlighted.
STEP 5
After the cleaning process, the water tank should be emptied and refilled with tap water. At this point, the water purifier will purify automatically and is ready for routine use.
Filter Replacement
STEP 1
Turn off the power and take out the old filters.
Diagram: Shows how to open the head cover by pressing a button and how to rotate and pull out the filter element.
STEP 2
Installation of new filter element.
Diagram: Shows the control panel with the Reset button highlighted. Instructions indicate to press and hold "RESET" and then touch "RESET" to select the corresponding filter element. Press and hold "RESET" for 3s to complete resetting.
Note: Only original Melissani filters should be used to ensure proper performance and safety of drinking water. For any issues during filter replacement, please contact customer service.
Filters
Filter | Material | Removes | Replacement Period |
---|---|---|---|
PAC | Folded Polypropylene and activated carbon rod composite | Dirt, Metal, Large Particles, Chlorine, VOC's, THM's and more. | 6 months or 3000 liters |
RO | 200G RO Flux Membrane | Remove all particles as small as .0001 microns. | 12 months or 6000 liters |
CF | Activated Carbon filter | Polishes water quality improves taste. | 6 months or 3000 liters |
Filter Club
Pure water for life with Filter Club
- Automated replacement filter delivery
- 10% Discount on replacement filters
- Extended 1-year Warranty
Scan or visit: melissaniwater.com/filter-club
Contact us
Email: contact@melissaniwater.com
Phone: 813-328-6390
Address: 4010 W. State Street, Tampa, FL 33609