GIZMOTCHY® 10/11 METER G21 BEAM ANTENNA

INSTRUCTIONS

Driven Elements overall length: 105 inches

Reflector Elements overall length: 109 inches

MOUNTING PROCEDURE

  1. Insert (3) Driven Elements into (3) Center Elements; overall length should be 105 inches.
  2. Place $1/2$ inch clamp over the assembly position and tighten.
  3. Use elements with plastic caps on Vertical position only.
  4. Repeat the above steps for the Reflector Element Assemblies. The overall length should be (3) Driven Elements and (3) Center Elements 105 inches; (3) Reflector Elements and (3) Center Elements 109 inches.
  5. Place Element Adapter Rings on Boom and position as to spacings on diagram.
  6. Fourteen #4 x 3/8 (small) metal screws furnished should be used on Element Assemblies to secure a permanent installation.

GIZMOTCHY® 10/11 METER 2 ELEMENT

PARTS LIST

Main Components

Part Qty OD Size Length Description
T257 1 $1 rac{1}{4}$" .058 64" Aluminum Tubing
T101 6 $ rac{1}{2}$" .050 48" Aluminum tubing slotted both ends
T102 6 3/8" .062 64" Aluminum tubing

HARDWARE BAG #1

Part Qty Size Description
GR1 1 1 Hole Ring
GR3 1 3 Hole Ring
C02 12 $ rac{1}{2}$" Clamp
S101 2 $ rac{1}{4}$" Thumbscrew
S102 12 #4 3/8" Sheet metal screws
S103 4 #6 3/8" Sheet metal screws
PL1 2 Plastic caps

HARDWARE BAG #2

Part Qty Size Description
U04 4 5/16" 1 1/4" U bolts
N03 8 5/16" Locknuts
P10 1 Mounting bracket

HARDWARE BAG #3

Part Qty Size Description
N101 8 #10 Star washer
S104 2 #10 3/4" Hex head bolt
N103 5 #10 Hex nut
S105 6 #10 1/2" Pan head screws
F-1 2 Gamma connecting bracket
H-1 2 Gamma Plates

Assembled Items

Part Qty Description
GGA11 2 Gamma assemblies
D-1 (11) 1 8" tube (3/8")
G-1 (11) 1 11" tube (3/8")
C03 2 $ rac{3}{4}$" Clamp
C02 2 $ rac{1}{2}$" Clamp
PL101 1 Plastic cap
1 Warranty sheet
1 10/11 meter 2 element inst.

Diagram Description

The main diagram illustrates the G21 Beam Antenna assembly. It shows two main elements: the Driven Element with an overall length of 105 inches and the Reflector Element with an overall length of 109 inches. Detail A provides a close-up of the adapter ring assembly, showing thumbscrews and 2x 10-32 screws with star lock washers securing the elements. Detail B shows a close-up of the element attachment to the boom, secured by #4 x 3/8 metal screws. The diagram also indicates a 20" vertical gamma match and a 15" horizontal gamma match. It notes that the length of all elements should be measured from the base of each element. Arrows indicate the front of the beam, with additional power boosters on this end.

ASSEMBLY OF 10 / 11 METER VERTICAL AND HORIZONTAL GAMMA MATCH

The second diagram shows the assembly of the gamma matches. It labels components like F-1 (Gamma connecting bracket), G-1 (Horizontal Gamma Match tube), B-1 (center section), A-1 (base mount), and H-1 (Gamma Plates). A plastic cap is shown for the top of an element. D-1 is identified as an 8-inch tube used for the Vertical Gamma Match only. Dimensions are provided: 15 inches for the Horizontal Gamma Match from the insulator, and 10 1/2 inches and 6 1/2 inches marked on the vertical assembly. D-1 is shown with a length of 11 inches. M359 right angle connector can be used for convenience (not furnished).

Assembly Instructions:

WARNING

Use caution when installing your Base Station. DO NOT contact electrical power lines of any type. Even 110 volts could be fatal. Read enclosed fact sheet and observe warning labels.

LIMITED WARRANTY

Charles Electronics, LLC warrants, under normal use and service, all products manufactured by it to be free from defects in materials and workmanship for a period of ninety (90) days from the date of delivery to the first consumer (the Warranty Period). Charles Electronics, LLC's obligation under this Warranty is limited to prompt repair or replacement of the product, at its option, without charge, when the product is returned to an authorized Charles Electronics, LLC dealer or the factory with all transportation charges prepaid. This Warranty shall not apply to any product which has been repaired or altered in any manner by anyone other than Charles Electronics, LLC or an authorized outlet, or if the defect, malfunction, or failure was caused by damage (not resulting from defect or malfunction) while in the possession of the consumer, or from unreasonable use, or from improper installation or application, or to any product which has not been maintained or used in accordance with the operating specifications set forth in Charles Electronics, LLC written instructions. Implied warranties of merchantability or fitness for any particular purpose are limited in duration to the ninety-day Warranty Period specified above. Under no circumstances shall Charles Electronics, LLC be liable for consequential damages for breach of this warranty or of any implied warranty. Charles Electronics, LLC neither assumes nor authorizes any person to assume for it any obligation or liability other than as herein expressly stated. This warranty gives you specific legal rights and you may also have other rights which vary from state to state.