User Manual for TBProAudio models including: PY0HWHU mvMeter2 Meter Plugin, PY0HWHU, mvMeter2 Meter Plugin, Meter Plugin, Plugin

mvMeter2 manual

tbpro

/80a05f7ce1310c70b73cb68dc4790c2646b1824b1cea1ece2...

PY0HWHU - TBProAudio

& 7%3ur$xglr 3djh ri ,qwurgxfwlrq :hofrph wr py0hwhu d pxowlyduldeoh phwhu lqfoxglqj 506 ( 98 dqg 330 phdvxuhphqw )hdwxuhv


File Info : application/pdf, 5 Pages, 563.86KB

PDF preview unavailable. Download the PDF instead.

mvMeter2 manual
mvMeter2
Manual

(C) TBProAudio 2022

TBProAudio 2022

Page 1 of 5

1 Introduction
Welcome to mvMeter2, a multivariable meter including RMS, EBUR128, VU and PPM measurement.
2 Features
mvMeter2 offers following features:
 behavior of classic analog VU and PPM meters  multiple measurement modes: PEAK, RMS, EBU R128, VU and PPM  multi channel metering: stereo, left, right, mid, side  single and dual meter display  adjustable reference level  adjustable meter delay  adjustable meter hold  adjustable OL level  preset management  adjustable pre-gain, gain matching  instance label  large and accurate live meters  64-bit internal processing  5 different meter themes  Free GUI scaling up 400%, ready for 4k displays

(C) TBProAudio 2022

Page 2 of 5

3 Design
mvMeter2 combines multiple meters into one plugin framed by a classic VU/PPM meter design:
 RMS: 600ms integration time  RMS+3dB: 600ms integration time, +3dB compensation according to AES-17  EBU R128-2014: ML and SL loudness measurement  Classic VU meter with dB and VU scale  Classic PPM Meter with BBC and EBU scale  Hold needle  Current and max value readout  Overload LED
4 Minimum System Requirements
 Windows 7, OpenGL 2 GFX card  Mac OS X 10.11, Metal GFX card  SSE2 CPU  Win: 32/64 Bit VST, 32/64 Bit VST3, 32/64 Bit AAX  OS X: 64 Bit VST, 64 Bit VST3, 64 Bit AU, 64 Bit AAX  Tested with: Cockos Reaper, Steinberg Cubase/Nuendo/Wavelab 6+, FL Studio 12+,
PT2018+, Reason 9.5+, Studio One, Ableton Live  For latest information please visit www.tbproaudio.de
5 Features

Preset menu: click to enter the preset menu, displays current preset and click to select previous or next preset.

Plugin menu: Get more information about the plugin, online version check, open the online manual, change log and fixed GUI scaling

Config page: meter settings (C) TBProAudio 2022

Page 3 of 5

Theme Selector: White, Classic, Dark, Retro or Deluxe
Channel Selector: click to select the channel mode. Single meter display: stereo, left, right, mid and side channel. Dual meter display: left/right, and mid/side channel.
Note for single meter display (stereo channel mode): Meter modes RMS, RMS +3, VU and PPM: channels are averaged. Meter modes Peak: channel max. Meter modes EBU ML, EBU SL: channels are summed (as described in EBUR128 spec)
Current Meter Value: readout of current meter value
Max. Meter Value: readout of max. meter value, click to reset value,
Meter Modes: Peak: RMS: 600ms integration time, -20/+3 scale RMS+3dB: 600ms integration time, +3dB compensation according to AES-17, -20/+3 scale EBU R128: ML and SL loudness measurement, -20/+3 scale Classic VU meter with dB and VU scale Classic PPM Meter with BBC and EBU scale
Pre-Gain: depending on the Channel Selector it controls the volume of the channel, click with right mouse button for numerical input. Double click resets value.
Gain Link: (dual screen only) sets both gain knobs together
Gain Match: matches the max. value with the reference value of corresponding meter mode by adjusting the pre gain value automatically. single needle mode: pre-gain is calculated based on the max. value dual needle mode: pre-gain is calculated based on the highest max. value of both channels and set to both pre-gain controls
Instance Label: click on the label to change the name of the plug-in instance.
Needle Mode: click to change the function of red needle, off, current or max. value.
Hide/Show GUI Elements: click to show/hide different controls like GUI scale, FPS, channel mode, current/max readouts, gain link/gain match button.
Single/Dual meter display: enables either single or dual meter display.
GUI Scale: mouse click and drag the bottom right scale icon.

(C) TBProAudio 2022

Page 4 of 5

Configuration page:

Meter Modes: peak, RMS, RMS+3, EBU, VU, PPM Reference. Level: sets the reference level in dB(FS) for the current meter mode. E.g. reference level for classic VU meter is -18dbFS Delay: delays the meter activity so it is time-synced with other busses with different latencies. OL (overload) LED mode: meter 0 = if needle is above meter zero or digital peak = if above OL LED level (in dBFS) OL (overload) LED level: LED lights if digital signal level is above value Needle hold time: determines how long current meter value is held

Presets:

Preset specification

(dbFS) -43 -40 -38 -34 -32 -30 -20 -18 -17 -15 -11 -9 -6 0 1 2 3

Peak

-20 -18

+3

RMS-20

-20

+2 +3

RMS-14

-20

-4

+3

RMS-12

-20

-6

+3

EBUR128 ML -20

+3 +5

EBUR128 SL -20

+3 +5

VU Standard

-20

0

+3

PPM (IIa - BBC)

1

4

7

RMS Standard

-23 -21

0

RMS +3dB (AES-17)

-20 -18

3

Readout values for 1kHz sinus -18dBFS Peak

Meter Mode Peak RMS +3dB RMS +3dB RMS +3dB EBU ML EBU SL VU PPM RMS RMS +3dB

Reference Level dBFS 0 -20 -14 -12 -23 -23 -18 -18 0 0

6 Conclusion
So finally if you have any questions or suggestions just let us know. Enjoy our audio tools and visit us here: www.tbproaudio.de.
Your team from TBProAudio :-)

(C) TBProAudio 2022

Page 5 of 5

