User Manual for TBProAudio models including: PY0HWHU mvMeter2 Meter Plugin, PY0HWHU, mvMeter2 Meter Plugin, Meter Plugin, Plugin
& 7%3ur$xglr 3djh ri ,qwurgxfwlrq :hofrph wr py0hwhu d pxowlyduldeoh phwhu lqfoxglqj 506 ( 98 dqg 330 phdvxuhphqw )hdwxuhv
File Info : application/pdf, 5 Pages, 563.86KB
DocumentDocumentmvMeter2 Manual (C) TBProAudio 2022 TBProAudio 2022 Page 1 of 5 1 Introduction Welcome to mvMeter2, a multivariable meter including RMS, EBUR128, VU and PPM measurement. 2 Features mvMeter2 offers following features: behavior of classic analog VU and PPM meters multiple measurement modes: PEAK, RMS, EBU R128, VU and PPM multi channel metering: stereo, left, right, mid, side single and dual meter display adjustable reference level adjustable meter delay adjustable meter hold adjustable OL level preset management adjustable pre-gain, gain matching instance label large and accurate live meters 64-bit internal processing 5 different meter themes Free GUI scaling up 400%, ready for 4k displays (C) TBProAudio 2022 Page 2 of 5 3 Design mvMeter2 combines multiple meters into one plugin framed by a classic VU/PPM meter design: RMS: 600ms integration time RMS+3dB: 600ms integration time, +3dB compensation according to AES-17 EBU R128-2014: ML and SL loudness measurement Classic VU meter with dB and VU scale Classic PPM Meter with BBC and EBU scale Hold needle Current and max value readout Overload LED 4 Minimum System Requirements Windows 7, OpenGL 2 GFX card Mac OS X 10.11, Metal GFX card SSE2 CPU Win: 32/64 Bit VST, 32/64 Bit VST3, 32/64 Bit AAX OS X: 64 Bit VST, 64 Bit VST3, 64 Bit AU, 64 Bit AAX Tested with: Cockos Reaper, Steinberg Cubase/Nuendo/Wavelab 6+, FL Studio 12+, PT2018+, Reason 9.5+, Studio One, Ableton Live For latest information please visit www.tbproaudio.de 5 Features Preset menu: click to enter the preset menu, displays current preset and click to select previous or next preset. Plugin menu: Get more information about the plugin, online version check, open the online manual, change log and fixed GUI scaling Config page: meter settings (C) TBProAudio 2022 Page 3 of 5 Theme Selector: White, Classic, Dark, Retro or Deluxe Channel Selector: click to select the channel mode. Single meter display: stereo, left, right, mid and side channel. Dual meter display: left/right, and mid/side channel. Note for single meter display (stereo channel mode): Meter modes RMS, RMS +3, VU and PPM: channels are averaged. Meter modes Peak: channel max. Meter modes EBU ML, EBU SL: channels are summed (as described in EBUR128 spec) Current Meter Value: readout of current meter value Max. Meter Value: readout of max. meter value, click to reset value, Meter Modes: Peak: RMS: 600ms integration time, -20/+3 scale RMS+3dB: 600ms integration time, +3dB compensation according to AES-17, -20/+3 scale EBU R128: ML and SL loudness measurement, -20/+3 scale Classic VU meter with dB and VU scale Classic PPM Meter with BBC and EBU scale Pre-Gain: depending on the Channel Selector it controls the volume of the channel, click with right mouse button for numerical input. Double click resets value. Gain Link: (dual screen only) sets both gain knobs together Gain Match: matches the max. value with the reference value of corresponding meter mode by adjusting the pre gain value automatically. single needle mode: pre-gain is calculated based on the max. value dual needle mode: pre-gain is calculated based on the highest max. value of both channels and set to both pre-gain controls Instance Label: click on the label to change the name of the plug-in instance. Needle Mode: click to change the function of red needle, off, current or max. value. Hide/Show GUI Elements: click to show/hide different controls like GUI scale, FPS, channel mode, current/max readouts, gain link/gain match button. Single/Dual meter display: enables either single or dual meter display. GUI Scale: mouse click and drag the bottom right scale icon. (C) TBProAudio 2022 Page 4 of 5 Configuration page: Meter Modes: peak, RMS, RMS+3, EBU, VU, PPM Reference. Level: sets the reference level in dB(FS) for the current meter mode. E.g. reference level for classic VU meter is -18dbFS Delay: delays the meter activity so it is time-synced with other busses with different latencies. OL (overload) LED mode: meter 0 = if needle is above meter zero or digital peak = if above OL LED level (in dBFS) OL (overload) LED level: LED lights if digital signal level is above value Needle hold time: determines how long current meter value is held Presets: Preset specification (dbFS) -43 -40 -38 -34 -32 -30 -20 -18 -17 -15 -11 -9 -6 0 1 2 3 Peak -20 -18 +3 RMS-20 -20 +2 +3 RMS-14 -20 -4 +3 RMS-12 -20 -6 +3 EBUR128 ML -20 +3 +5 EBUR128 SL -20 +3 +5 VU Standard -20 0 +3 PPM (IIa - BBC) 1 4 7 RMS Standard -23 -21 0 RMS +3dB (AES-17) -20 -18 3 Readout values for 1kHz sinus -18dBFS Peak Meter Mode Peak RMS +3dB RMS +3dB RMS +3dB EBU ML EBU SL VU PPM RMS RMS +3dB Reference Level dBFS 0 -20 -14 -12 -23 -23 -18 -18 0 0 6 Conclusion So finally if you have any questions or suggestions just let us know. Enjoy our audio tools and visit us here: www.tbproaudio.de. Your team from TBProAudio :-) (C) TBProAudio 2022 Page 5 of 5