Series BDL Button Data Logger

A circular data logger device, labeled "BUTTON DATA LOGGER" with the Dwyer logo, connected to a coiled black cable ending in a USB connector.

Technical drawings illustrating the dimensions of the Button Data Logger, showing a circular device with a diameter of approximately 17.07 mm (0.67 inches) and a thickness of approximately 6.35 mm (0.25 inches).

The Series BDL Button Data Logger records temperature and humidity in applications where size and cost effectiveness are vital. Housed in a compact stainless steel case, the BDL is durable in hostile environments, while also being able to be inserted in small items and packages. The Series BDL-K Logger Kit includes 2 buttons, 2 magnets, an interface cable, and a plastic button holder.

Features/Benefits

Applications

Accessories

ModelDescriptionPrice
DL500-LITE*Lite version Windows® operating system software$38.75[net priced]
DL500**Full version Windows® operating system software key$231.00[net priced]
BDL-SILWeatherproof silicone housing (5 pk)$31.00[net priced]
BDL-WALLWall mounting bracket (5 pk)$31.00[net priced]
BDL-CLIPPlastic button holder (5 pk)$31.00[net priced]
BDL-1Temperature input data logger, no kit$122.00[net priced]
BDL-2Temperature/humidity input data logger, no kit$407.00[net priced]

*Free download from website **Need lite version also

Specifications

General

Range: BDL-1: -40 to 185°F (-40 to 85°C); BDL-2: -4 to 185°F (-20 to 85°C), 0 to 100% RH.

Memory Size: BDL-1: 2048 readings; BDL-2: 4096 temperature and 4096 humidity readings (low resolution), 2048 temperature and 2048 humidity readings (high resolution).

Accuracy: BDL-1: ±1.5°F (±1°C) from -22 to 158°F (-30 to 70°C); BDL-2: ±0.9°F (±0.5°C) from 14 to 158°F (-10 to 70°C), ±5% RH.

Resolution: BDL-1: 8 bit; BDL-2: 8 or 11 bit.

Sampling Method: Stop on memory full or continuous recording.

Sampling Rate: BDL-1: Selectable from 1 to 255 min.; BDL-2: Selectable from 1 s to 24 hrs.

Computer Requirements: Windows® 98, Windows® 2000, Windows® ME, Windows NT®, Windows® XP, and Windows Vista® operating system with 16 MB RAM, one free USB port.

Power Requirements: 3 V lithium metal battery, internal, non-replaceable.

Battery Life: BDL-1: 10 years (approx); BDL-2: 5 years (approx).

Alarms: Programmable high/low.

Interface: USB port (cable included with kits).

Housing Material: 305 SS.

Weight: 0.14 oz (4 g).

Model Chart

ModelInput TypeKitPrice
BDL-K1TemperatureYes$424.00[net priced]
BDL-K2Temperature/humidityYes$987.00[net priced]

Items are net priced and are not subject to any discount.

Windows®, Windows NT®, and Windows Vista® are registered trademarks of Microsoft Corporation.


Model GDL & GDL-T Graphical Display Data Loggers

The Model GDL Graphical Display Data Logger can record and instantly display temperature, humidity, and dew point trends in a text or graphic format. The GDL has internal temperature and humidity sensors while the Model GDL-T Graphical Display Data Logger accepts up to 3 external temperature sensors. With the included Windows® based software, the user can select the sampling interval, high/low alarms, logging channels, and recording start time. Over 40,000 data points can be recorded and the measured data stays secure with a recording session counter and password-protected calibration.

Technical drawings illustrating the dimensions of the GDL/GDL-T data logger, showing a rectangular device with dimensions of approximately 77.79 mm (3-1/16 inches) in width and 38.1 mm (1-1/2 inches) in height.

Features/Benefits

Applications

Model Chart

ModelDescriptionPrice
GDLTemperature/humidity data logger$253.00[net priced]
GDL-TFour temperature sensor data logger$258.00[net priced]

Items are net priced and are not subject to any discount.

Windows® is a registered trademark of Microsoft Corporation.

PDF preview unavailable. Download the PDF instead.

GDL d Adobe InDesign CC 13.1 (Macintosh) Adobe PDF Library 15.0

Related Documents

Preview DwyerLog Logger Interface Software User's Guide - Dwyer Instruments
Comprehensive user's guide for DwyerLog Logger Interface Software, detailing setup, operation, data logging, calibration, and specifications for MTL-30, MTL-20, and GDL data loggers from Dwyer Instruments.
Preview Dwyer Temperature Sensors: TE-WSS Stainless Steel and TE-E/N Wall Mount Series
Detailed information on Dwyer Instruments' TE-WSS stainless steel wall plate temperature sensors and TE-E/N wall mount temperature sensors, including features, specifications, applications, and model options for building automation and environmental monitoring.
Preview Dwyer Instruments PPM Series Panel Meter Specifications
Technical specifications and dimensions for the Dwyer Instruments PPM Series Panel Meter, a dual-line pulse input rate/totalizer display.
Preview Dwyer Series V6 Flotect Flow Switch: Specifications, Installation, and Operation
Comprehensive guide to the Dwyer Series V6 Flotect Flow Switch, covering specifications, installation instructions, electrical connections, and performance data for various configurations and applications.
Preview Dwyer Series WHT Weather-Resistant Humidity/Temperature Transmitter
Dwyer Series WHT is a weather-resistant humidity and temperature transmitter designed for applications like air handling economizers and agricultural environment monitoring. It features a compact NEMA 3S housing, a removable sintered filter, and offers 4-20 mA or 0-10 VDC output signals for both temperature and humidity.
Preview Mercoid SBLTX Submersible Level Transducer: Specifications and Installation Instructions
Comprehensive guide to the Mercoid Series SBLTX Submersible Level Transducer by Dwyer Instruments, covering detailed specifications, intrinsic safety approvals (UL, ATEX, IECEx, UKCA), installation procedures, and maintenance information for industrial applications.
Preview Dwyer Series 605 Magnehelic Differential Pressure Transmitter - Specifications and Instructions
Detailed specifications, installation, and operating instructions for the Dwyer Series 605 Magnehelic Differential Pressure Indicating Transmitter. Covers features, model chart, electrical and mechanical specifications, mounting, pressure connections, and output ranging.
Preview Dwyer Series P/G Explosion Proof Ultra Mag™ Level Switch: Specifications and Installation Guide
Comprehensive specifications, installation, and operating instructions for the Dwyer Series P/G Explosion Proof Ultra Mag™ Level Switch, designed for bulk solids level indication in industrial applications.