Installation Guide for zeta ALARMS models including: GLT-279-6-3, GLT-279-6-3 Addressable Raptor Sounder and Beacon, Addressable Raptor Sounder and Beacon, Raptor Sounder and Beacon
28 jul 2022 — All 8 switches are used for the address setting. It is a binary arrangement, with ON being the zero position. Switch. 1.8 páginas
File Info : application/pdf, 8 Pages, 1.04MB
DocumentDocumentADDRESSABLE RAPTOR SOUNDER & SOUNDER BEACON - INSTALLATION MANUAL ADDRESSABLE RAPTOR SOUNDER & SOUNDER BEACON INSTALLATION MANUAL Description The Raptor addressable sounder is a large weatherproof horn sounder suitable for many indoor & outdoor applications. It is available in red or white and has a selection of 16 tones, selectable at the control panel Termination of field wiring is made to the backbox for a clean first fix. Connections - First Fix The loop wiring connects to terminals in the back box. Final Fix · Set the device address (see address setting) · Fix the BROWN sounder flying lead to the POSITIVE terminal · Fix the BLUE sounder flying leads to the RIGHT NEGATIVE terminal · Screw the sounder body to the backbox. Backbox Sounder Body Earth Not Used Positive In/Out Negative In/Out Sounder Flying Leads Document No: GLT-271-7-2 Issue No: 008 Page 1 Author: NRP Jones Date: 28/07/2022 ADDRESSABLE RAPTOR SOUNDER & SOUNDER BEACON - INSTALLATION MANUAL Address Setting This sounder is addressed via an 8 way dip switch. All 8 switches are used for the address setting. It is a binary arrangement, with ON being the zero position. Switch 1 2 3 4 5 6 7 8 Value when ON 0 0 0 0 0 0 0 0 Value when Off 1 2 4 8 16 32 64 128 The Switch settings can be calculated using these numbers. EG 21 = 16 +4 +1, so Switches 1,3 & 5 are off, all the others are on. The maximum address is 250. For convenience a table of all address settings can be found at the end of themanual. Alternative Soft Addressing Option Using our hand held MkII programmer (Part No: 48-004), the sounder can be addressed electronically. Step 1: Set all addresses to zero 0000000 Step 2: Connect leads to LOOP IN+ and LOOP IN- as shown below + Lin _ Lin Step 3: Follow the procedure as described in the handheld programmer manual. NOTE: When a device is soft addressed as above, the address CANNOT BE CHANGED by mechanical setting of the dip-switch. In order to re-enable the dip-switch the unit needs to be set electronically back to zero first. Protocol Usage The Raptor Sounder and sounder beacon work on the Zeta Fyreye II protocol only. The flasher (if fitted) can be triggered independently to the sounder, if the control panel supports that function. Sounder Synchronisation The Raptor sounders support the Fyreye II sounder synchronisation mechanism. Document No: GLT-271-7-2 Issue No: 008 Page 2 Author: NRP Jones Date: 28/07/2022 ADDRESSABLE RAPTOR SOUNDER & SOUNDER BEACON - INSTALLATION MANUAL Alarm Tone Selection The Raptor sounder supports alarm tone selection. IE, the installer can decide which alarm tone ALL the sounders will use. The alarm tone can be set for the whole system via the control panel. One of 16 tones can be chosen for the alarm tone. No Tone Description 0* BS Fire (Default Zeta tone) 1 BS Fire 2 BS Fire 3 BS Fire 4 BS Fire 5 BS Fire 6 German fire (DIN 33 404) 7 French fire (NFS 32-001) 8* Dutch fire (NEN 2575) 9 PFEER Toxic Gas 10 PFEER alert 11 Reserved 12 Reserved 13 Reserved 14 Reserved 15 Reserved * Approved Tones Pattern Frequency Rate Alternating 800 & 970 1Hz (500ms-500ms) Alternating 800 & 970 2Hz (250ms-250ms) Sweep 800 to 970 1Hz (1 per second) Sweep 800 to 970 7Hz (7 per second) Sweep 800 to 970 50Hz (50 per second) Alternating 510 & 610 1Hz (500ms-500ms) Sweep (DIN) 1200 to 500 1Hz Alternating 554 & 440 100ms-400ms Slow whoop 500 to 1200 3.5s sweep, 0.5 s silence, then repeat Continuous 970 Steady Intermittent 970 0.5Hz (1s On/1s Off) - - - - - - - - - - - - - - - See Document GLT-279-6-3 for further operational data. Selecting a Reserved tone will cause the sounder to play tone 0. The default alarm tone will be tone 0. Other Tones The Raptor has 3 tones that can be triggered in normal running:- · Alarm Tone Selectable see list above. · Alert tone 970Hz intermittent. 0.5s on, 0.5s off · Emergency - 970Hz intermittent: 3 x 500ms pulses, 1.5s silence, then repeat The availability of these tones will depend on the Control panel used. Document No: GLT-271-7-2 Issue No: 008 Page 3 Author: NRP Jones Date: 28/07/2022 ADDRESSABLE RAPTOR SOUNDER & SOUNDER BEACON - INSTALLATION MANUAL Flasher Setting The Raptor has a 4 way dip switch for configuring the flasher. Switches 1 to 3 configure the flasher as shown below. Switch 4 is for future use. Setting 1 gives the specified flasher rating. Setting 1* 2 3 4 5 6 7 8 Switch 1 OFF ON OFF ON OFF ON OFF ON Switch 2 OFF OFF ON ON OFF OFF ON ON Switch 3 OFF OFF OFF OFF ON ON ON ON Flash rate 0.5 Hz 0.33 Hz 0.33 Hz 0.33 Hz 0.5 Hz 1.0 Hz 1.5 Hz OFF Current 43mA 18mA 25mA 33mA 33mA 43mA 43mA 5.4mA Relative Flasher intensity 100% 60% 85% 99% 89% 69% 46% 0% * Approved Flasher setting Beacon Coverage The Raptor addressable sounder with beacon (ZRAPB/R & ZRAPB/W) has a coverage pattern of W-3.0-8.7 and an approved flash rate of 0.5 Hz. 3.0m 8.7m 8.7m 8.7m 8.7m Document No: GLT-271-7-2 Issue No: 008 Page 4 Author: NRP Jones Date: 28/07/2022 ADDRESSABLE RAPTOR SOUNDER & SOUNDER BEACON - INSTALLATION MANUAL Technical Data Model Part Number Colour Flash Colour Flash Rate Flasher Coverage Sounder Output (Anechoic) Operating Voltage Quiescent Current Alarm Current Sounder Type Operating Temperature Minimum Continuous Operating Temperature Max Humidity IP Rating Size (H x W x D in mm ) Weight (with Back Box) Minimum sound output 62.7dB Troubleshooting ZRAP/R 42-635 Red ZRAP/W 42-636 White N/A N/A N/A ZRAPB/R 42-637 ZRAPB/W 42-638 Red White White flash 0.33 - 1.5 Hz (depends on setting) W-3.0-8.7 for setting 1 82.9dB @1m 5.4 mA max 17-28 V 1.5 mA 19-44 mA (depends on setting) Type B (outdoor use) -25oC to +70oC 0oC 95% RH Non Condensing 146 x 150 x 98 540g IP33C 146 x 150 x 107.5 550g Problem Device Not Seen By Panel Sounder Is Not Operating Flasher is not operating Can Not Start An Individual Sounder Possible Cause Check the device is addressed within the range of the panel :1 To 250 for a Quatro / 1 To 126 for a Simplicity Plus Other panels check panel manuals for info Check that loop is connected with correct polarity Check that sounder flying leads have been connected to the backbox. Check the panel is running the Zeta Fyreye MkII protocol Check panel`s actions (cause & effect) programming is correct. Check that the flasher LED wires have not been disconnected Check panel`s actions (cause & effect) programming is correct. Check whether triggering individual sounders is supported by the control panel Check the cause & effect programming to see if common operation has been selected Document No: GLT-271-7-2 Issue No: 008 Page 5 Author: NRP Jones Date: 28/07/2022 ADDRESSABLE RAPTOR SOUNDER & SOUNDER BEACON - INSTALLATION MANUAL ADDRESS SW1 SW2 SW3 SW4 SW5 SW6 SW7 SW8 ADDRESS SW1 SW2 SW3 SW4 SW5 SW6 SW7 SW8 0 1 OFF ON ON ON ON ON ON ON 2 ON OFF ON ON ON ON ON ON 3 OFF OFF ON ON ON ON ON ON 4 ON ON OFF ON ON ON ON ON 5 OFF ON OFF ON ON ON ON ON 6 ON OFF OFF ON ON ON ON ON 7 OFF OFF OFF ON ON ON ON ON 8 ON ON ON OFF ON ON ON ON 9 OFF ON ON OFF ON ON ON ON 10 ON OFF ON OFF ON ON ON ON 11 OFF OFF ON OFF ON ON ON ON 12 ON ON OFF OFF ON ON ON ON 13 OFF ON OFF OFF ON ON ON ON 14 ON OFF OFF OFF ON ON ON ON 15 OFF OFF OFF OFF ON ON ON ON 16 ON ON ON ON OFF ON ON ON 17 OFF ON ON ON OFF ON ON ON 18 ON OFF ON ON OFF ON ON ON 19 OFF OFF ON ON OFF ON ON ON 20 ON ON OFF ON OFF ON ON ON 21 OFF ON OFF ON OFF ON ON ON 22 ON OFF OFF ON OFF ON ON ON 23 OFF OFF OFF ON OFF ON ON ON 24 ON ON ON OFF OFF ON ON ON 25 OFF ON ON OFF OFF ON ON ON 26 ON OFF ON OFF OFF ON ON ON 27 OFF OFF ON OFF OFF ON ON ON 28 ON ON OFF OFF OFF ON ON ON 29 OFF ON OFF OFF OFF ON ON ON 30 ON OFF OFF OFF OFF ON ON ON 31 OFF OFF OFF OFF OFF ON ON ON 32 ON ON ON ON ON OFF ON ON 33 OFF ON ON ON ON OFF ON ON 34 ON OFF ON ON ON OFF ON ON 35 OFF OFF ON ON ON OFF ON ON 36 ON ON OFF ON ON OFF ON ON 37 OFF ON OFF ON ON OFF ON ON 38 ON OFF OFF ON ON OFF ON ON 39 OFF OFF OFF ON ON OFF ON ON 40 ON ON ON OFF ON OFF ON ON 41 OFF ON ON OFF ON OFF ON ON 42 ON OFF ON OFF ON OFF ON ON 43 OFF OFF ON OFF ON OFF ON ON 44 ON ON OFF OFF ON OFF ON ON 45 OFF ON OFF OFF ON OFF ON ON 46 ON OFF OFF OFF ON OFF ON ON 47 OFF OFF OFF OFF ON OFF ON ON 48 ON ON ON ON OFF OFF ON ON 49 OFF ON ON ON OFF OFF ON ON 50 ON OFF ON ON OFF OFF ON ON 51 OFF OFF ON ON OFF OFF ON ON 52 ON ON OFF ON OFF OFF ON ON 53 OFF ON OFF ON OFF OFF ON ON 54 ON OFF OFF ON OFF OFF ON ON 55 OFF OFF OFF ON OFF OFF ON ON 56 ON ON ON OFF OFF OFF ON ON 57 OFF ON ON OFF OFF OFF ON ON 58 ON OFF ON OFF OFF OFF ON ON 59 OFF OFF ON OFF OFF OFF ON ON 60 ON ON OFF OFF OFF OFF ON ON 61 OFF ON OFF OFF OFF OFF ON ON 62 ON OFF OFF OFF OFF OFF ON ON 63 OFF OFF OFF OFF OFF OFF ON ON 64 ON ON ON ON ON ON OFF ON 65 OFF ON ON ON ON ON OFF ON 66 ON OFF ON ON ON ON OFF ON 67 OFF OFF ON ON ON ON OFF ON 68 ON ON OFF ON ON ON OFF ON 69 OFF ON OFF ON ON ON OFF ON 70 ON OFF OFF ON ON ON OFF ON 71 OFF OFF OFF ON ON ON OFF ON 72 ON ON ON OFF ON ON OFF ON 73 OFF ON ON OFF ON ON OFF ON 74 ON OFF ON OFF ON ON OFF ON 75 OFF OFF ON OFF ON ON OFF ON 76 ON ON OFF OFF ON ON OFF ON 77 OFF ON OFF OFF ON ON OFF ON 78 ON OFF OFF OFF ON ON OFF ON 79 OFF OFF OFF OFF ON ON OFF ON 80 ON ON ON ON OFF ON OFF ON 81 OFF ON ON ON OFF ON OFF ON 82 ON OFF ON ON OFF ON OFF ON 83 OFF OFF ON ON OFF ON OFF ON 84 ON ON OFF ON OFF ON OFF ON 85 OFF ON OFF ON OFF ON OFF ON 86 ON OFF OFF ON OFF ON OFF ON 87 OFF OFF OFF ON OFF ON OFF ON 88 ON ON ON OFF OFF ON OFF ON 89 OFF ON ON OFF OFF ON OFF ON 90 ON OFF ON OFF OFF ON OFF ON 91 OFF OFF ON OFF OFF ON OFF ON 92 ON ON OFF OFF OFF ON OFF ON 93 OFF ON OFF OFF OFF ON OFF ON 94 ON OFF OFF OFF OFF ON OFF ON 95 OFF OFF OFF OFF OFF ON OFF ON 96 ON ON ON ON ON OFF OFF ON 97 OFF ON ON ON ON OFF OFF ON 98 ON OFF ON ON ON OFF OFF ON 99 OFF OFF ON ON ON OFF OFF ON 100 ON ON OFF ON ON OFF OFF ON 101 OFF ON OFF ON ON OFF OFF ON 102 ON OFF OFF ON ON OFF OFF ON 103 OFF OFF OFF ON ON OFF OFF ON 104 ON ON 105 OFF ON ON OFF ON OFF OFF ON ON OFF ON OFF OFF ON 106 ON OFF ON OFF ON OFF OFF ON 107 OFF OFF ON OFF ON OFF OFF ON 108 ON ON OFF OFF ON OFF OFF ON 109 OFF ON OFF OFF ON OFF OFF ON 110 ON OFF OFF OFF ON OFF OFF ON 111 OFF OFF OFF OFF ON OFF OFF ON 112 ON ON ON ON OFF OFF OFF ON 113 OFF ON ON ON OFF OFF OFF ON 114 ON OFF ON 115 OFF OFF ON ON OFF OFF OFF ON ON OFF OFF OFF ON 116 ON ON OFF ON OFF OFF OFF ON 117 OFF ON OFF ON OFF OFF OFF ON 118 ON OFF OFF ON OFF OFF OFF ON 119 OFF OFF OFF ON OFF OFF OFF ON 120 ON ON ON OFF OFF OFF OFF ON 121 OFF ON ON OFF OFF OFF OFF ON 122 ON OFF ON OFF OFF OFF OFF ON 123 OFF OFF ON OFF OFF OFF OFF ON 124 ON ON OFF OFF OFF OFF OFF ON 125 OFF ON OFF OFF OFF OFF OFF ON 126 ON OFF OFF OFF OFF OFF OFF ON 127 OFF OFF OFF OFF OFF OFF OFF ON Document No: GLT-271-7-2 Issue No: 008 Page 6 Author: NRP Jones Date: 28/07/2022 ADDRESSABLE RAPTOR SOUNDER & SOUNDER BEACON - INSTALLATION MANUAL ADDRESS SW1 SW2 SW3 SW4 SW5 SW6 SW7 SW8 ADDRESS SW1 SW2 SW3 SW4 SW5 SW6 SW7 SW8 128 ON ON ON ON ON ON ON OFF 129 OFF ON ON ON ON ON ON OFF 130 ON OFF ON ON ON ON ON OFF 131 OFF OFF ON ON ON ON ON OFF 132 ON ON OFF ON ON ON ON OFF 133 OFF ON OFF ON ON ON ON OFF 134 ON OFF OFF ON ON ON ON OFF 135 OFF OFF OFF ON ON ON ON OFF 136 ON ON ON OFF ON ON ON OFF 137 OFF ON ON OFF ON ON ON OFF 138 ON OFF ON OFF ON ON ON OFF 139 OFF OFF ON OFF ON ON ON OFF 140 ON ON OFF OFF ON ON ON OFF 141 OFF ON OFF OFF ON ON ON OFF 142 ON OFF OFF OFF ON ON ON OFF 143 OFF OFF OFF OFF ON ON ON OFF 144 ON ON ON ON OFF ON ON OFF 145 OFF ON ON ON OFF ON ON OFF 146 ON OFF ON 147 OFF OFF ON ON OFF ON ON OFF ON ON OFF ON OFF 148 ON ON OFF ON OFF ON 149 OFF ON OFF ON OFF ON 150 ON OFF OFF ON OFF ON 151 OFF OFF OFF ON OFF ON 152 ON ON ON OFF OFF ON 153 OFF ON ON OFF OFF ON 154 ON OFF ON OFF OFF ON 155 OFF OFF ON OFF OFF ON 156 ON ON OFF OFF OFF ON 157 OFF ON OFF OFF OFF ON 158 ON OFF OFF OFF OFF ON 159 OFF OFF OFF OFF OFF ON ON OFF ON OFF ON OFF ON OFF ON OFF ON OFF ON OFF ON OFF ON OFF ON OFF ON OFF ON OFF 160 ON ON ON ON ON OFF ON OFF 161 OFF ON ON ON ON OFF ON OFF 162 ON OFF ON ON ON OFF ON OFF 163 OFF OFF ON ON ON OFF ON OFF 164 ON ON OFF ON 165 OFF ON OFF ON ON OFF ON OFF ON OFF ON OFF 166 ON OFF OFF ON 167 OFF OFF OFF ON ON OFF ON OFF ON OFF ON OFF 168 ON ON ON OFF ON OFF ON OFF 169 OFF ON ON OFF ON OFF ON OFF 170 ON OFF ON OFF ON OFF ON OFF 171 OFF OFF ON OFF ON OFF ON OFF 172 ON ON OFF OFF ON OFF ON OFF 173 OFF ON OFF OFF ON OFF ON OFF 174 ON OFF OFF OFF ON OFF ON OFF 175 OFF OFF OFF OFF ON OFF ON OFF 176 ON ON ON ON OFF OFF ON OFF 177 OFF ON ON ON OFF OFF ON OFF 178 ON OFF ON ON OFF OFF ON OFF 179 OFF OFF ON ON OFF OFF ON OFF 180 ON ON OFF ON OFF OFF ON OFF 181 OFF ON OFF ON OFF OFF ON OFF 182 ON OFF OFF ON OFF OFF ON OFF 183 OFF OFF OFF ON OFF OFF ON OFF 184 ON ON 185 OFF ON ON OFF OFF OFF ON OFF ON OFF OFF OFF ON OFF 186 ON OFF ON OFF OFF OFF ON OFF 187 OFF OFF ON OFF OFF OFF ON OFF 188 ON ON OFF OFF OFF OFF ON OFF 189 OFF ON OFF OFF OFF OFF ON OFF 190 ON OFF OFF OFF OFF OFF ON OFF 191 OFF OFF OFF OFF OFF OFF ON OFF 192 ON ON ON ON ON ON OFF OFF 193 OFF ON ON ON ON ON OFF OFF 194 ON OFF ON ON ON ON OFF OFF 195 OFF OFF ON ON ON ON OFF OFF 196 ON ON OFF ON ON ON OFF OFF 197 OFF ON OFF ON ON ON OFF OFF 198 ON OFF OFF ON ON ON OFF OFF 199 OFF OFF OFF ON ON ON OFF OFF 200 ON ON ON OFF ON ON OFF OFF 201 OFF ON ON OFF ON ON OFF OFF 202 ON OFF ON OFF ON ON OFF OFF 203 OFF OFF ON OFF ON ON OFF OFF 204 ON ON OFF OFF ON 205 OFF ON OFF OFF ON ON OFF OFF ON OFF OFF 206 ON OFF OFF OFF ON 207 OFF OFF OFF OFF ON ON OFF OFF ON OFF OFF 208 ON ON ON ON OFF ON OFF OFF 209 OFF ON ON ON OFF ON OFF OFF 210 ON OFF ON ON OFF ON OFF OFF 211 OFF OFF ON ON OFF ON OFF OFF 212 ON ON OFF ON OFF ON OFF OFF 213 OFF ON OFF ON OFF ON OFF OFF 214 ON OFF OFF ON OFF ON OFF OFF 215 OFF OFF OFF ON OFF ON OFF OFF 216 ON ON 217 OFF ON ON OFF OFF ON OFF OFF ON OFF OFF ON OFF OFF 218 ON OFF ON OFF OFF ON OFF OFF 219 OFF OFF ON OFF OFF ON OFF OFF 220 ON ON OFF OFF OFF ON OFF OFF 221 OFF ON OFF OFF OFF ON OFF OFF 222 ON OFF OFF OFF OFF ON OFF OFF 223 OFF OFF OFF OFF OFF ON OFF OFF 224 ON ON ON ON ON OFF OFF OFF 225 OFF ON ON ON ON OFF OFF OFF 226 ON OFF ON ON ON OFF OFF OFF 227 OFF OFF ON ON ON OFF OFF OFF 228 ON ON OFF ON 229 OFF ON OFF ON ON OFF OFF OFF ON OFF OFF OFF 230 ON OFF OFF ON ON OFF OFF OFF 231 OFF OFF OFF ON ON OFF OFF OFF 232 ON ON ON OFF ON OFF OFF OFF 233 OFF ON ON OFF ON OFF OFF OFF 234 ON OFF ON OFF ON OFF OFF OFF 235 OFF OFF ON OFF ON OFF OFF OFF 236 ON ON OFF OFF ON OFF OFF OFF 237 OFF ON OFF OFF ON OFF OFF OFF 238 ON OFF OFF OFF ON OFF OFF OFF 239 OFF OFF OFF OFF ON OFF OFF OFF 240 ON ON ON ON OFF OFF OFF OFF 241 OFF ON ON ON OFF OFF OFF OFF 242 ON OFF ON ON OFF OFF OFF OFF 243 OFF OFF ON ON OFF OFF OFF OFF 244 ON ON OFF ON OFF OFF OFF OFF 245 OFF ON OFF ON OFF OFF OFF OFF 246 ON OFF OFF ON OFF OFF OFF OFF 247 OFF OFF OFF ON OFF OFF OFF OFF 248 ON ON ON OFF OFF OFF OFF OFF 249 OFF ON ON OFF OFF OFF OFF OFF 250 ON OFF ON OFF OFF OFF OFF OFF 251 252 253 254 255 Document No: GLT-271-7-2 Issue No: 008 Page 7 Author: NRP Jones Date: 28/07/2022 ADDRESSABLE RAPTOR SOUNDER & SOUNDER BEACON - INSTALLATION MANUAL Other Information Like all electronic equipment, at the end of it`s working life this unit should not be disposed of in a refuse bin. It should be taken to a local reprocessing site as per the guidelines of the WEEE directive, for correct disposal. 2831 Zeta Alarms Limited 72-78 Morfa Road, Swansea SA1 2EN 17 2831-CPR-F2046 2831-CPR-F2048 EN54-3:2001+A1:2002 + A2: 2006 Alarm Devices Sounder Type B: For Outdoor Use ZRAP/R (W) EN 54-3:2001 + A1:2002 + A2:2006, EN 54-23: 2010 Alarm Devices Sounder & VAD Type B: For Outdoor Use ZRAPB/R (W) Other Technical Data: See Doc: "Addressable Raptor Product file" held by the manufacturer Zeta Alarms Limited, 72-78 Morfa Road, Swansea SA1 2EN Document No: GLT-271-7-2 Issue No: 008 Page 8 Author: NRP Jones Date: 28/07/2022Adobe PDF Library 16.0.7 Adobe InDesign 17.3 (Windows)