Instruction Manual for DELFIELD models including: F18MC60E, F18 Series Refrigerated Work Tables, Refrigerated Work Tables, Work Tables, Tables
DELFIELD F18MC60E (01) PDF MANUAL - MANUAL-HUB.COM
File Info : application/pdf, 28 Pages, 2.97MB
DocumentDocumentF18 SERIES Service and Installation Manual Please read this manual completely before attempting to install or operate this equipment! Notify carrier of damage! Inspect all components immediately. Refrigerated Work Tables, Salad Tables & Freezer Bases Important Information Read Before Use Please Save These Instructions! July 2013 https://manual-hub.com/ F18 Series Service and Installation Manual Important Warning And Safety Information WARNING Read This Manual Thoroughly Before Operating, Installing, Or Performing Maintenance On The Equipment. WARNING Failure To Follow Instructions In This Manual Can Cause Property Damage, Injury Or Death. WARNING Do Not Store Or Use Gasoline Or Other Flammable Vapors Or Liquids In The Vicinity Of This Or Any Other Appliance. WARNING Unless All Cover And Access Panels Are In Place And Properly Secured, Do Not Operate This Equipment. WARNING This Appliance Is Not Intended For Use By Persons Who Lack Experience Or Knowledge, Unless They Have Been Given Supervision Or Instruction Concerning Use Of The Appliance By A Person Responsible For Their Safety. WARNING This Appliance Is Not To Be Played With. WARNING Do Not Clean With Water Jet. WARNING Do Not Use Electrical Appliances Inside The Food Storage Compartment Of This Appliance. CAUTION Observe the following: · Minimum clearances must be maintained from all walls and combustible materials. · Keep the equipment area free and clear of combustible material. · Allow adequate clearance for air openings. · Operate equipment only on the type of electricity indicated on the specification plate. · Unplug the unit before making any repairs. · Retain this manual for future reference. 2 For customer service, call (800) 733-8829, (800) 773-8821, Fax (989) 773-3210, www.delfield.com https://manual-hub.com/ Contents Receiving & Inspecting .........................................................3 Serial Number Location ........................................................4 Warranty Information............................................................4 Regulatory Certifications.......................................................4 Specifications.................................................................... 5-7 Installation ............................................................................8 Operation ..............................................................................9 Temperature Settings ..........................................................10 Maintenance.................................................................. 11-12 Wiring Diagrams........................................................... 13-16 Replacement Part Lists................................................. 17-20 Replacement Part Assemblies ...................................... 21-24 Standard Labor Guidelines..................................................25 Notes ............................................................................ 26-27 F18 Series Service and Installation Manual Receiving and Inspecting the Equipment Even though most equipment is shipped crated, care should be taken during unloading so the equipment is not damaged while being moved into the building. 1. Visually inspect the exterior of the package an skid or container. Any damage should be noted and reported to the delivering carrier immediately. 2. If damaged, open and inspect the contents with the carrier. 3. In the event that the exterior is not damaged, yet upon opening, there is concealed damage to the equipment notify the carrier. Notification should be made verbally as well as in written form. 4. Request an inspection of the concealed equipment. This should be done within 10 days from receipt of the equipment. 5. Check the lower portion of the unit to be sure legs or casters are not bent. 6. Also open the compressor compartment housing and visually inspect the refrigeration package. Be sure lines are secure and base is still intact. 7. Freight carriers can supply the necessary forms upon request. 8. Retain all crating material until an inspection has been made or waived. Uncrating the Equipment First cut and remove the banding from around the crate. Remove the front of the crate material, use of some tools will be required. If the unit is on legs remove the top of the crate as well and lift the unit off the skid. If the unit is on casters it can be "rolled" off the skid. For customer service, call (800) 733-8829, (800) 773-8821, Fax (989) 773-3210, www.delfield.com 3 https://manual-hub.com/ F18 Series Service and Installation Manual Serial Number Location The serial number on all self-contained F18 Series refrigerated work tables and freezer bases is located on the electrical specifications tag affixed inside the compressor section next to the pressure control. On remote refrigerated bases with doors, the tag is inside the unit on the coil side. On remote refrigerated bases with drawers, the tag is affixed to the drawer divider. On remote freezer bases, the tag is located on the inside back of the unit. Always have the serial number of your unit available when calling for parts or service. A complete list of authorized Delfield parts depots is available at www.delfield.com. ©2013 The Delfield Company. All rights reserved. Reproduction without written permission is prohibited. "Delfield" is a registered trademark of The Delfield Company. Warranty Information Visit http://www.delfield.com/minisite/service/warranty_info to: · Register your product for warranty. · Verify warranty information. · View and download a copy of your warranty. Regulatory Certifications Models are certified by: National Sanitation Foundation (NSF) Underwriters Laboratories (UL) Underwriters Laboratories of Canada (ULC) 4 For customer service, call (800) 733-8829, (800) 773-8821, Fax (989) 773-3210, www.delfield.com https://manual-hub.com/ F18 Series Service and Installation Manual Specifications Remote Refrigerated Work Tables Model Shelf Max Base Volume Shelf Volts/Hertz/ # Of Doors Load (lbs) FT3 Area FT2 Phase F18WR31 (1) 19" 70 7.56 2.56 115/60/1 F18WR39 (1) 27" 124 10.23 3.95 115/60/1 F18WR44 (2) 19" 70 12.14 5.12 115/60/1 F18WR52 (1) 19" & (1) 27" 70/124 15.12 6.51 115/60/1 F18WR60 (2) 27" 124 18.10 7.90 115/60/1 F18WR70 (2) 32" 140 21.23 9.64 115/60/1 F18WR79 (2) 27" & (1) 19" 124/70 24.48 10.29 115/60/1 F18WR87 (3) 27" 124 27.46 11.85 115/60/1 Amps 3.0 3.0 3.0 3.0 3.0 3.0 6.0 6.0 BTU Load 383 465 605 686 768 869 1050 1131 EVAP. BTU/°TD 120/3° 120/4° 120/5° 120/6° 120/6° 120/7° 240/4° 240/5° Self-Contained Refrigerated Work Tables Model Shelf Max Base Volume Shelf Volts/Hertz/ # Of Doors Load (lbs) FT3 Area FT2 Phase F18WC39 (1) 19" 70 7.56 2.56 115/60/1 F18WC47 (1) 27" 124 10.23 3.95 115/60/1 F18WC52 (2) 19" 70 12.14 5.12 115/60/1 F18WC60 (1) 19" & (1) 27" 70/124 15.12 6.51 115/60/1 F18WC68 (2) 27" 124 18.10 7.90 115/60/1 F18WC78 (2) 32" 140 21.23 9.64 115/60/1 F18WC87 (2) 27" & (1) 19" 124/70 24.48 10.29 115/60/1 F18WC95 (3) 27" 124 27.46 11.85 115/60/1 Amps 8.0 8.0 8.0 8.0 10.0 10.0 10.0 10.0 R-404A BTU Load BTU System Cap. oz. H.P. 383 1462 16 1/5 465 1462 16 1/5 605 1462 16 1/5 686 1462 16 1/5 768 1462 16 1/4 869 1994 16 1/4 1050 2261 16 1/4 1131 2261 16 1/4 NEMA Plug 5-15P 5-15P 5-15P 5-15P 5-15P 5-15P 5-15P 5-15P Remote Refrigerated Mega Top Salad Tables Model Shelf Max Base Volume Volts/Hertz/ # Of Doors Load (lbs) FT3 # of Pans Phase F18MR31A (1) 19" 70 4.14 6 115/60/1 F18MR44A (2) 19" 70 7.15 6 115/60/1 F18MR44D (2) 19" 70 7.15 12 115/60/1 F18MR52A (1) 19" & (1) 27" 70/124 8.97 6 115/60/1 F18MR52D (1) 19" & (1) 27" 70/124 8.97 12 115/60/1 F18MR52E (1) 19" & (1) 27" 70/124 8.97 18 115/60/1 Amps 3.0 3.0 3.0 3.0 3.0 3.0 BTU Load Base/Rail 280/265 444/265 444/529 515/265 515/529 515/794 EVAP. BTU/°TD Base/Rail 120/2°/12/22° 120/4°/12/22° 120/4°/22/25° 120/4°/12/22° 120/4°/22/25° 120/4°/31/26° Self-Contained Refrigerated Mega Top Salad Tables Model Shelf Max Base Volume Volts/Hertz/ BTU Load BTU System Cap. R-404A NEMA # Of Doors Load (lbs) FT3 # of Pans Phase Amps Base/Rail Base/Rail oz. H.P. Plug F18MC39A (1) 19" 70 4.14 6 115/60/1 10.0 280/265 1903/925 16 1/4 5-15P F18MC39D (1) 19" 70 4.14 12 115/60/1 10.0 280/529 1903/1156 16 1/4 5-15P F18MC52A (2) 19" 70 7.15 6 115/60/1 10.0 444/265 1903/925 16 1/4 5-15P F18MC52D (2) 19" 70 7.15 12 115/60/1 10.0 444/529 1903/1156 16 1/4 5-15P F18MC52E (2) 19" 70 7.15 18 115/60/1 10.0 444/794 1903/1321 16 1/4 5-15P F18MC60A (1) 19" & (1) 27" 70/124 8.97 6 115/60/1 10.0 515/265 2314/864 16 1/4 5-15P F18MC60D (1) 19" & (1) 27" 70/124 8.97 12 115/60/1 10.0 515/529 2314/1141 16 1/4 5-15P F18MC60E (1) 19" & (1) 27" 70/124 8.97 18 115/60/1 10.0 515/794 2314/1361 16 1/4 5-15P F18MC60F (1) 19" & (1) 27" 70/124 8.97 24 115/60/1 10.0 515/1058 2314/1540 16 1/4 5-15P For customer service, call (800) 733-8829, (800) 773-8821, Fax (989) 773-3210, www.delfield.com 5 https://manual-hub.com/ F18 Series Service and Installation Manual Specifications Remote Refrigerated Salad Top Tables Model Shelf Max Base Volume # Of Doors Load (lbs) FT3 F18SR31A (1) 19" 70 4.14 F18SR44A (2) 19" 70 7.15 F18SR44B (2) 19" 70 7.15 F18SR44C (2) 19" 70 7.15 F18SR52A (1) 19" & (1) 27" 70/124 8.97 F18SR52B (1) 19" & (1) 27" 70/124 8.97 F18SR52C (1) 19" & (1) 27" 70/124 8.97 F18SR52D (1) 19" & (1) 27" 70/124 8.97 # of Pans 6 6 8 10 6 8 10 12 Volts/Hertz/ Phase Amps 115/60/1 3.0 115/60/1 3.0 115/60/1 3.0 115/60/1 3.0 115/60/1 3.0 115/60/1 3.0 115/60/1 3.0 115/60/1 3.0 BTU Load Base/Rail 280/265 491/441 491/441 491/441 532/529 532/529 532/529 532/529 Evap. BTU/°TD Base/Rail 120/2°/13/21° 120/4°/13/21° 120/4°/16/22° 120/4°/19/23° 120/4°/13/21° 120/4°/16/22° 120/4°/19/23° 120/4°/23/23° Self-Contained Refrigerated Salad Top Tables Model Shelf Max Base Volume # Of Doors Load (lbs) FT3 F18SC39A (1) 19" 70 4.14 F18SC39B (1) 19" 70 4.14 F18SC52A (2) 19" 70 7.15 F18SC52B (2) 19" 70 7.15 F18SC52C (2) 19" 70 7.15 F18SC52D (2) 19" 70 7.15 F18SC60A (1) 19" & (1) 27" 70/124 8.97 F18SC60B (1) 19" & (1) 27" 70/124 8.97 F18SC60C (1) 19" & (1) 27" 70/124 8.97 F18SC60D (1) 19" & (1) 27" 70/124 8.97 # of Pans 6 8 6 8 10 12 6 8 10 12 Volts/Hertz/ Phase Amps 115/60/1 10.0 115/60/1 10.0 115/60/1 10.0 115/60/1 10.0 115/60/1 10.0 115/60/1 10.0 115/60/1 10.0 115/60/1 10.0 115/60/1 10.0 115/60/1 10.0 BTU Load Base/Rail 280/265 280/353 444/265 444/353 444/441 444/529 515/265 515/353 515/441 515/529 BTU System R-404A NEMA Cap. Base/Rail oz. H.P. Plug 1903/745 16 1/4 5-15P 1903/867 16 1/4 5-15P 1903/745 16 1/4 5-15P 1903/867 16 1/4 5-15P 1903/971 16 1/4 5-15P 1903/1061 16 1/4 5-15P 2314/667 16 1/4 5-15P 2314/798 16 1/4 5-15P 2314/916 16 1/4 5-15P 2314/1023 16 1/4 5-15P Remote Refrigerated Reduced Height Rail Model Shelf Max Base Volume Shelf # Of Doors Load (lbs) FT3 Area FT2 F18DR44 (2) 19" 70 9.54 5.12 F18DR52 (1) 19" & (1) 27" 70/124 13.89 6.51 F18DR60 (2) 27" 124 16.64 7.9 F18DR70 (2) 32" 140 22.96 9.64 F18DR79 (1) 19" & (2) 27" 70/124 22.47 10.29 F18DR87 (3) 27" 124 25.22 11.85 # of Pans 10 12 16 18 18 22 Volts/Hertz/ Phase Amps 115/60/1 3.0 115/60/1 3.0 115/60/1 5.0 115/60/1 5.0 115/60/1 5.0 115/60/1 5.0 BTU Load Base/Rail 547/441 625/529 703/617 800/794 962/882 1032/970 Evap. BTU/°TD Base/Rail 120/5°/19/23° 120/5°/23/23° 120/6°/26/24° 120/7°/32/24° 240/4°/36/25° 240/4°/39/25° Self-Contained Refrigerated Reduced Height Rail Model Shelf Max Base Volume Shelf # Of Doors Load (lbs) FT3 Area FT2 F18DC52 (2) 19" 70 9.54 5.12 F18DC60 (1) 19" & (1) 27" 70/124 13.89 6.51 F18DC68 (2) 27" 124 16.64 7.9 F18DC82 (2) 32" 140 22.96 9.64 F18DC91 (1) 19" & (2) 27" 70/124 22.47 10.29 F18DC99 (3) 27" 124 25.22 11.85 # of Pans 12 14 18 20 22 24 Volts/Hertz/ Phase Amps 115/60/1 10.0 115/60/1 12.0 115/60/1 12.0 115/60/1 14.0 115/60/1 14.0 115/60/1 14.0 BTU Load Base/Rail 547/529 625/617 703/794 800/882 962/1058 1032/1147 BTU System R-404A NEMA Cap. Base/Rail oz. H.P. Plug 1903/1061 16 1/4 5-15P 2314/1121 24 1/3 5-15P 2314/1544 24 1/3 5-15P 3097/1648 32 1/2 5-20P 3807/1839 32 1/2 5-20P 3807/1839 32 1/2 5-20P 6 For customer service, call (800) 733-8829, (800) 773-8821, Fax (989) 773-3210, www.delfield.com https://manual-hub.com/ Specifications F18 Series Service and Installation Manual Remote Refrigerated Reduced Height Rail Model Shelf Max Base Volume Shelf Volts/Hertz/ BTU Load Evap. BTU/°TD # of # Of Doors Load (lbs) FT3 Area FT2 Phase Amps Base/Rail Base/Rail Pans F18RR44 (2) 19" 70 9.49 5.12 115/60/1 3.0 547/441 120/5°/19/23° 10 F18RR52 (1) 19" & (1) 27" 70/124 11.81 6.51 115/60/1 3.0 625/529 120/5°/23/23° 12 F18RR60 (2) 27" 124 14.14 7.9 115/60/1 5.0 703/617 120/6°/26/24° 16 F18RR70 (2) 32" 140 17.05 9.64 115/60/1 5.0 800/794 120/7°/32/24° 18 F18RR79 (1) 19" & (2) 27" 70/124 18.68 10.29 115/60/1 5.0 962/882 240/4°/36/25° 18 F18RR87 (3) 27" 124 21.30 11.85 115/60/1 5.0 1032/970 240/4°/39/25° 22 Self-Contained Refrigerated Reduced Height Rail Model Shelf Max Base Volume Shelf Volts/Hertz/ BTU Load BTU System # of R-404A # Of Doors Load (lbs) FT3 Area FT2 Phase Amps Base/Rail Cap. Base/Rail Pans oz. H.P. F18RC52 (2) 19" 70 9.49 5.12 115/60/1 10.0 547/529 1903/1061 12 16 1/4 F18RC60 (1) 19" & (1) 27" 70/124 11.81 6.51 115/60/1 12.0 625/617 2314/1121 14 24 1/3 F18RC68 (2) 27" 124 14.14 7.9 115/60/1 12.0 703/794 2314/1544 16 24 1/3 F18RC82 (2) 32" 140 17.05 9.64 115/60/1 14.0 800/882 3097/1648 20 32 1/2 F18RC91 (1) 19" & (2) 27" 70/124 18.68 10.29 115/60/1 14.0 962/1058 3807/1839 22 32 1/2 F18RC99 (3) 27" 124 21.30 11.85 115/60/1 14.0 1032/1147 3807/1839 24 32 1/2 NEMA Plug 5-15P 5-15P 5-15P 5-20P 5-20P 5-20P Remote Freezer Base Model Shelf Max Base Volume Shelf Volts/Hertz/ # Of Doors Load (lbs) FT3 Area FT2 Phase Amps F18FR35 (1) 19" 70 5.58 2.56 115/60/1 10.0 F18FR50 (2) 19" 70 12.21 5.12 115/60/1 10.0 F18FR58 (1) 19" & (1) 27" 70/124 15.00 6.51 115/60/1 10.0 F18FR66 (2) 27" 124 17.79 7.9 115/60/1 10.0 F18FR76 (2) 32" 140 21.28 9.64 115/60/1 10.0 BTU Load Base/Rail 943 1471 1844 2020 2437 Evap. BTU/°TD 160/6° 160/9° 160/10° 160/11° 160/13° Self-Contained Freezer Base Model Shelf Max Base Volume Shelf Volts/Hertz/ BTU Load BTU System R-404A NEMA # Of Doors Load (lbs) FT3 Area FT2 Phase Amps Base/Rail Cap. Base/Rail H.P. oz. Plug F18FC43 (1) 19" 70 5.58 2.56 115/60/1 10.0 943 1558 1/3 24 5-15P F18FC62 (2) 19" 70 12.21 5.12 115/60/1 12.0 1471 1776 1/2 40 5-15P F18FC70 (1) 19" & (1) 27" 70/124 15.00 6.51 115/60/1 16.0 1647 2713 3/4 56 5-20P F18FC78 (2) 27" 124 17.79 7.9 115/60/1 16.0 1824 2713 3/4 56 5-20P F18FC88 (2) 32" 140 21.28 9.64 115/60/1 16.0 2045 2713 3/4 56 5-20P Self-Contained Dual Rails Model F18PD48 F18PD72 # Of Doors (1) 27" (2) 27" Shelf Max Base Volume Shelf Volts/Hertz/ Load (lbs) FT3 Area FT2 Phase Amps 124 9.38 3.95 115/60/1 10.0 124 16.64 7.90 115/60/1 12.7 BTU Load Base/Rail 424/1058 703/1588 BTU System R-404A Cap. Base/Rail H.P. oz. 2001/1865 1/5, 1/3 40 2001/3174 1/5. 1/2 48 NEMA Plug 5-20P 5-20P For customer service, call (800) 733-8829, (800) 773-8821, Fax (989) 773-3210, www.delfield.com 7 https://manual-hub.com/ F18 Series Service and Installation Manual Installation Location These units are intended for indoor use only. Be sure the location chosen has a floor strong enough to support the total weight of the cabinet and contents. A fully loaded 72" (183cm) long model may weigh as much as 1500 pounds (680kg)! Reinforce the floor as necessary to provide for maximum loading. It is very important to allow for proper air flow, both inside and outside. Avoid hot corners and locations near stoves, ovens and other pieces of cooking equipment. It is recommended that the unit be installed no closer than 1" (2.54cm) from any wall. Do not install the unit near any combustible material or object affected by heat or moisture. PDL models also require 14" (36cm) clearance at the top and 6" (15cm) clearance at the bottom (casters). Leveling A level cabinet looks better and will perform better because the drain pan will drain properly, the doors will line up with the frames properly, and the cabinet will not be subject to undue strain. A unit on legs will have an adjustable bullet foot on each leg, adjust each for a level unit. A unit on casters will not be adjustable. Be sure the unit is on a level floor, make necessary changes to the floor for proper level. Lock all front casters to ensure the stability of the unit. Plumbing Self-contained models are standard with a condensate evaporator. If, for some reason a unit does not have a condensate evaporator, or if the evaporator fails, the unit's drain must have an outlet to an appropriate drainage area or container. A refrigerated rail will have a 1" (2.54cm) drain which will need to be run to an appropriate floor drain or container. The drain will be stubbed to the bottom of the machine compartment. Either run drain to a floor drain or add a valve to the base of the machine compartment and drain the rail to a container when convenient. The LiquiTec option will NOT have a drain available. CAUTION Moisture collecting from improper drainage can create a slippery surface on the floor and a hazard to employees. It is the owner's responsibility to provide a container or outlet for drainage. Electrical connection Refer to the specification pages amperage data, the serial tag, your local code or the National Electrical Code to be sure the unit is connected to the proper power source. A protected circuit of the correct voltage and amperage must be run for connection of the line cord, or permanent connection of the unit. Self-contained units with a cord and plug have an ON/OFF switch located directly behind the louvered panel covering the compressor section. Simply turn the switch to ON to begin operation. The power switch must be turned to OFF and the unit disconnected from the power source whenever performing service or maintenance functions. Never operate the unit without the louvered panel in place! If electrical receptacles are to be mounted in the unit's backsplash, they must be wired independently from the existing unit wiring. 8 For customer service, call (800) 733-8829, (800) 773-8821, Fax (989) 773-3210, www.delfield.com https://manual-hub.com/ F18 Series Service and Installation Manual Refrigerator Operation Power up the unit by turning ON the unit's ON/OFF switch. Delfield refrigerated bases are designed to maintain an operational temperature of 36°F to 40°F (2°C to 4°C). Temperature in the salad top and refrigerated rail opening is 33°F to 41°F (0°C to 5°C) with pans recessed 2" (5.1cm) on a standard wrapped refrigerated rail or flush with the LiquiTec option at 86°F (30°C) ambient room temperature. Do not place hot pans on/against the blue ABS liner. Do not throw items into the storage area. Failure to heed these recommendations could result in damage to the interior of the cabinet or to the blower coil. Overloading the storage area, restricting the air flow, and continuous opening and closing of the doors and drawers will hamper the units ability to maintain operational temperature. Refrigerated rail units Product in the rail should be removed to the refrigerated base at the end of the day. This allows you to turn the rail off at night to save energy and the rail will have time to defrost as needed. It also helps maintain product quality. The standard wrapped refrigerated units are controlled by the pressure control which is set to maintain the proper rail temperature. An on/off switch is also provided for the rail and is required to be shut off at night. The rail switch shuts off the rail only. With a LiquiTec rail a thermostat is provided to maintain rail temperature as well as the rail on/off switch. The LiquiTec rail is required to be shut off at night as well to allow for defrosting. To ensure product quality in the rail it is recommended that product be rotated every four hours. If adding any item to the unit, be sure to keep in mind the location of the refrigeration lines on wrapped rail units. A refrigeration leak in a rail is extremely difficult and costly to repair. In some cases it cannot be repaired at all. Refrigerator Evaporator Fan Operation When the refrigerator is initially powered up or immediately following a power outage the unit will begin cooling after a 3-6 minute delay. During normal operation the evaporator fan pulses independently of the compressor as dictated by the controller as follows: 1. During the cooling mode, compressor and evaporator fan run simultaneously. 2. During the compressor off mode, evaporator fan pulses three minutes on and three minutes off. 3. During an actual defrost event other than the off-cycle defrost, compressor stays off but the evaporator fan runs continuously. Cooling Cycle Compressor On Compressor Off Evap Fan Evap Fan Evap Fan Evap Fan On Off On Off X Cycles On 3-Min, Off 3-Min Defrost Cycle Compressor Off Evap Fan Evap Fan On Off X Freezer Operation Power up the unit by turning ON the unit's ON/OFF switch. Delfield freezer bases are designed to maintain an operational temperature of 0°F (-18°C). Do not place hot pans on/against the blue ABS liner. Do not throw items into the storage area. Failure to heed these recommendations could result in damage to the interior of the cabinet or to the blower coil. Overloading the storage area, restricting the air flow, and continuous opening and closing of the doors and drawers will hamper the units ability to maintain operational temperature. Cooling Cycle All Freezers Compressor On Evap Fan On Compressor Off Evap Fan Off Defrost Cycle Self-Contained Freezers Remote Freezers Compressor On Compressor Off Evap Fan Off Evap Fan Off Freezer Defrost Self-contained models use hot gas to defrost the evaporator coils. Remote freezers use electric defrost. Freezer Evaporator Fan Operation The evaporator fan(s) and condenser fan will cycle off and on with the compressor to conserve energy. The temperature control will cycle the compressor and condenser fan motor and evaporator fan motor to maintain box temperature at the control setting. For customer service, call (800) 733-8829, (800) 773-8821, Fax (989) 773-3210, www.delfield.com 9 https://manual-hub.com/ F18 Series Service and Installation Manual Temperature Control Settings A thermostat controls temperature in the self-contained F18WC, F18FC, F18MC base, F18SC base, F18RC base, F18DC base, F18PD base and F18PD rails. Thermostats are located in the machine compartment. They are field adjustable and do not require a service agent. The factory setting is 2.5. Set toward 1 for higher temperatures and toward 7 for lower temperatures. A thermostat controls temperature in the remote F18FR. The temperature control is located in the machine compartment. It is field adjustable and does not require a service agent. The factory setting for a remote freezer is 0°F cut-in with a 5°F differential. Please make small incremental adjustments if a temperature adjustment is necessary. It may take an hour or longer to realize the temperature change depending on the application and location of the unit. Contact the service department at Delfield +1 (989) 773-7981 or your local service agent for additional assistance. Delfield is not responsible for charges incurred while adjusting the thermostat. Pressure Control Settings A pressure control controls temperature in the F18MC mega top, F18SC salad top, F18RC rail and F18DC rail. The factory recommended low-pressure control settings are: 55psi cut-in and 30psi cut-out to maintain proper temperature for product. The interior temperature is controlled by the thermostat mounted in the mechanical compartment. A pressure control is located in the machine compartment. An adjustable control has the word COLDER on the knob, with an arrow to indicate the adjustment direction. These controls are field adjustable and do not require a service agent. In attempting to adjust the pressure control, you can do damage to your unit by accidentally adjusting the differential. Please make small incremental adjustments if a temperature adjustment is necessary. It may take an hour or longer to realize the temperature change depending on the application and location of the unit. Please contact the service department at Delfield (800) 733-8829 or your local service agent. Delfield is not responsible for charges incurred while having the pressure control adjusted. 10 For customer service, call (800) 733-8829, (800) 773-8821, Fax (989) 773-3210, www.delfield.com https://manual-hub.com/ F18 Series Service and Installation Manual Maintenance Door Gasket Maintenance Door gaskets require regular cleaning to prevent mold and mildew build up and also to retain the elasticity of the gasket. Gasket cleaning can be done with the use of warm soapy water. Avoid full strength cleaning products on gaskets as this can cause them to become brittle and crack. Never use sharp tools or knives to scrape or clean the gasket. Gaskets can be easily replaced and do not require the use of tools or an authorized service person. The gaskets are "Dart" style and can be pulled out of the groove in the door and new gaskets can be "pressed" back into place. Drain Maintenance - Base Each unit has a drain located inside the unit that removes the condensation from the evaporator coil and routes it to an external condensate evaporator pan. Each drain can become loose or disconnected during normal use. If you notice water accumulation on the inside of the unit be sure the drain tube is connected to the evaporator drain pan. If water is collecting underneath the unit make sure the end of the drain tube is in the condensate evaporator in the machine compartment. The leveling of the unit is important as the units are designed to drain properly when level. Be sure all drain lines are free of obstructions. Drawer Maintenance Drawer Assembly Cleaning The drawer assembly is designed to be cleaned easily. Both drawer and tracks are removable without tools. The drawer tracks are dishwasher safe or can be cleaned in a sink with detergents and a soft bristle brush. Drawers and tracks should be cleaned on a weekly basis. Remove Drawers Pull the drawer box out until it stops. Lift up on the drawer front and pull the drawer box completely out. Using a soft bristle brush, clean the track on the bottom of the drawer box. When finished, it should be wiped clean of all food and debris. Tracks The drawer box assembly must be removed. Pull the drawer tracks out until they hit a stop. Locate blue safety clips towards the back of each drawer track. Blue safety clips have a tab on the top. Push the tab back until it clicks. Lift up and pull the drawer tracks all the way out of the drawer cage. The drawer tracks are dishwasher safe or can be cleaned in a sink with detergents and a soft tab on top of blue safety clip bristle brush. Drawers and tracks should be cleaned on a weekly basis. Using a soft bristle brush, wash the track making sure each roller is thoroughly cleaned. The drawer cage should be cleaned with a soft bristle brush, removing any food and debris gathered on the bottom ledge. Once it's cleaned thoroughly with a soft bristle brush, wipe remaining debris clean with a soft towel. Reassembly Push the drawer tracks into the drawer cage. The blue safety clip must remain pushed towards the back. Lift up and slide the drawer track all the way into the drawer cage. The blue safety clip will lock in place automatically. Once all tracks are replaced, insert the drawer box. Rest the drawer box bottom track on the front track roller. Then push the drawer back in place SLOWLY. When the drawer box is about half way in you will hit a STOP. You must lift the front of the drawer up approximately ½" (1.3cm) to continue inward. Clean tracks as often as possible. The cleaner the tracks are the better they will operate. Caster Maintenance Wipe casters with a damp cloth monthly to prevent corrosion. The power switch must be turned to OFF and the unit disconnected from the power source whenever performing service, maintenance functions or cleaning the refrigerated area. Refrigerators and Freezers The interior and exterior can be cleaned using soap and warm water. If this isn't sufficient, try ammonia and water or a nonabrasive liquid cleaner. When cleaning the exterior, always rub with the "grain" of the stainless steel to avoid marring the finish. Do not use an abrasive cleaner because it will scratch the stainless steel and can damage the breaker strips and gaskets. Stainless Steel Care and Cleaning To prevent discoloration of rust on stainless steel several important steps need to be taken. First, we need to understand the properties of stainless steel. Stainless steel contains 70- 80% iron, which will rust. It also contains 12-30% chromium, which forms an invisible passive film over the steels surface, which acts as a shield against corrosion. As long as the protective layer is intact, the metal is still stainless. If the film is broken or contaminated, outside elements can begin to breakdown the steel and begin to form discoloration of rust. Proper cleaning of stainless steel requires soft cloths or plastic scouring pads. NEVER USE STEEL PADS, WIRE BRUSHES OR SCRAPERS! Cleaning solutions need to be alkaline based or non-chloride cleaners. Any cleaner containing chlorides will damage the protective film of the stainless steel. Chlorides are also commonly found in hard water, salts, and household and industrial cleaners. If cleaners containing chlorides are used be sure to rinse repeatedly and dry thoroughly. Routine cleaning of stainless steel can be done with soap and water. Extreme stains or grease should be cleaned with a non-abrasive cleaner and plastic scrub pad. Always rub with the grain of the steel. There are stainless steel cleaners available which can restore and preserve the finish of the steels protective layer. Early signs of stainless steel breakdown are small pits and cracks. If this has begun, clean thoroughly and start to apply stainless steel cleaners in attempt to restore the passivity of the steel. Never use an acid based cleaning solution! Many food products have an acidic content, which can deteriorate the finish. Be sure to clean the stainless steel surfaces of ALL food products. Common items include, tomatoes, peppers and other vegetables. 11 For customer service, call (800) 733-8829, (800) 773-8821, Fax (989) 773-3210, www.delfield.com https://manual-hub.com/ F18 Series Service and Installation Manual Maintenance, continued Cleaning the Condenser Coil In order to maintain proper refrigeration performance, the condenser fins must be cleaned of dust, dirt and grease regularly. It is recommended that this be done at least every three months. If conditions are such that the condenser is totally blocked in three months, the frequency of cleaning should be increased. Clean the condenser with a vacuum cleaner or stiff brush. If extremely dirty, a commercially available condenser cleaner may be required. Failure to maintain a clean condenser coil can initially cause high temperatures and excessive run times. Continuous operation with a dirty or clogged condenser coil can result in compressor failure. Neglecting the condenser coil cleaning procedures will void any warranties associated with the compressor and cost to replace the compressor. Never use a high-pressure water wash for this cleaning procedure as water can damage the electrical components located near or at the condenser coil. Doors/Hinges Over time and with heavy use doors the hinges may become loose. If this happens tighten the screws that mount the hinge brackets to the frame of the unit. Loose or sagging doors can cause the hinges to pull out of the frame, which may damage both the doors and the hinges. In some cases this may require qualified service agents or maintenance personnel to perform repairs. Do not place hot pans on/against the blue ABS liner. Do not throw items into the storage area. Failure to follow these recommendations could result in damage to the interior of the cabinet or to the blower coil. Overloading the storage area, restricting the airflow, and continuous opening and closing of the doors and drawers will hamper the units ability to maintain operational temperature. Refrigerated rail units Product in the rail should be removed to the refrigerated base at the end of the day. This allows you to turn the rail off at night to save energy and to defrost the rail. It also helps maintain product quality. The standard wrapped refrigerated rail units are controlled by a lowpressure control that is set to maintain the proper rail temperature. An on/off switch is also provided for the rail and is required to be shut off at night. With a LiquiTec rail a thermostat is provided to maintain rail temperature as well as the rail on/off switch. The LiquiTec rail is required to be shut off at night as well to allow for defrosting. To ensure product quality in the rail it is recommended that product be rotated every four hours. If adding any item to the unit, be sure to keep in mind the location of the refrigeration lines on wrapped rail units. A refrigeration leak in a rail is extremely difficult and costly to repair. In some cases it cannot be repaired at all. Preventing blower coil corrosion To help prevent corrosion of the blower coil, store all acidic items, such as pickles and tomatoes, in sealable containers. Immediately wipe up all spills. Units with pans should be operated with pans in place. Operating the unit without all pans in place will lower efficiency and may damage the unit. Continuous opening and closing of the doors will hamper the unit's ability to maintain optimum refrigeration temperature. Top section is not intended for overnight storage. Product should be removed from pans. Pans can remain in unit while empty. 12 For customer service, call (800) 733-8829, (800) 773-8821, Fax (989) 773-3210, www.delfield.com https://manual-hub.com/ Wiring Diagram, F18WC F18 Series Service and Installation Manual Wiring Diagram, F18WR 13 For customer service, call (800) 733-8829, (800) 773-8821, Fax (989) 773-3210, www.delfield.com https://manual-hub.com/ F18 Series Service and Installation Manual Wiring Diagram, F18MC, F18SC, F18DC & F18RC Wiring Diagram, F18MR, F18SR, F18DR & F18RR 14 For customer service, call (800) 733-8829, (800) 773-8821, Fax (989) 773-3210, www.delfield.com https://manual-hub.com/ Wiring Diagram, F18FC F18 Series Service and Installation Manual Wiring Diagram, F18FR 15 For customer service, call (800) 733-8829, (800) 773-8821, Fax (989) 773-3210, www.delfield.com https://manual-hub.com/ F18 Series Service and Installation Manual Wiring Diagram, F18PD 16 For customer service, call (800) 733-8829, (800) 773-8821, Fax (989) 773-3210, www.delfield.com https://manual-hub.com/ F18 Series Service and Installation Manual Replacement Parts F18DC 3516053 *000-248-0030 *000-BN5-0035 *000-BN5-0037 *000-BN5-0030 2194824 2193927 3234392 3234282 3234266 9321374 0160179 3234645 3977984 3977998 3978014 3977983 2190154 3516225 3516102 3234290 9321040 9321132 Coil, solenoid, 120V/50/60HZ (rail) Coil assembly, R404A Condensing unit, 1/2hp, R404a Condensing unit, 1/3hp, R404a Condensing unit, 1/4hp, R404a Control, Danfoss, GDM, 115V Control, pressure, low Hinge, pan cover, center Hinge, pan cover, left Hinge, pan cover, right Hinge, pin (for pan cover) Hinge Kit Leg, 6", s/s Shelf, 19" door Shelf, 24" door Shelf, 27" door Shelf, 32" door Switch, rocker Valve, expansion (rail) Valve, solenoid (rail) Shelf support, 1" blue Shelf support screw (coil side) Shelf support screw (wall side) F18DR 3516053 *000-248-0030 *000-248-0037 2194824 3234392 3234282 3234266 9321374 0160179 3234645 3977984 3977998 3978014 3977983 3234290 Coil, solenoid, 120V/50/60HZ (rail) Coil assembly, R404A Coil assembly, R404A, Fan Lt Control, Danfoss, GDM, 115V Hinge, pan cover, center Hinge, pan cover, left Hinge, pan cover, right Hinge, pin (for pan cover) Hinge Kit (left or right hinged) Leg, 6", s/s Shelf, 19" door Shelf, 24" door Shelf, 27" door Shelf, 32" door Shelf support, 1" blue 9321040 9321132 2190154 2194201 3516225 3516102 Shelf support screw (coil side) Shelf support screw (wall side) Switch, rocker Thermostat, rail Valve, expansion (rail) Valve, solenoid (rail) F18FC *000-BN5-0053 *000-BN5-0054 *000-BN5-0055 *000-249-0004 2194758-4 0160179 3234645 9321040 9321132 3234290 3977984 3977998 3978014 3977983 2190154 Condensing unit, 1/3HP, w/rec, hg Condensing unit, 1/2HP, low temp, hg Condensing unit, 3/4HP, low temp, hg Coil, assembly, freezer, R404a Control, Danfoss, Freezer, 115V Hinge Kit Leg, 6", s/s Shelf support screw (coil side) Shelf support screw (wall side) Shelf support, 1" blue Shelf, 19" door Shelf, 24" door Shelf, 27" door Shelf, 32" door Switch, rocker F18FR *000-249-0006 3516053 3516056 0160179 3234645 9321040 9321132 3234290 3977984 3977998 3978014 3977983 2194151 3516102 Coil assembly, frz evap, remote Coil, solenoid, 120V/50/60HZ Control, Temperature Hinge Kit Leg, 6", s/s Shelf support screw (coil side) Shelf support screw (wall side) Shelf support, 1" blue Shelf, 19" door Shelf, 24" door Shelf, 27" door Shelf, 32" door Timer, Paragon, #8145-00 Valve, solenoid *Replacement part assemblies on pages 19-22. 17 For customer service, call (800) 733-8829, (800) 773-8821, Fax (989) 773-3210, www.delfield.com https://manual-hub.com/ F18 Series Service and Installation Manual Replacement Parts, continued F18MC 030-209-0030 3516053 *000-248-0030 *000-248-0037 *000-BN5-0030 2194824 2193927 3234392 3234282 3234266 9321374 0420068 2190154 3516225 3516102 3234645 Angle, Coil, Top Baffle Coil, solenoid, 120V/50/60HZ (rail) Coil assembly, R404A Coil assembly, R404A, Fan Lt Condensing unit, 1/4hp, R404a Control, Danfoss, GDM, 115V Control, pressure, low Hinge, pan cover, center Hinge, pan cover, left Hinge, pan cover, right Hinge, pin (for pan cover) Hinge kit, lo profile (left or right) Switch, rocker Valve, expansion (rail) Valve, solenoid (rail) Leg, 6", s/s F18MR 030-209-0030 3516053 *000-248-0030 *000-248-0037 2194824 3234392 3234282 3234266 9321374 0420068 3234645 9321041 2190154 2194201 3516225 3516102 Angle, Coil, Top Baffle Coil, solenoid, 120V/50/60HZ (rail) Coil assembly, R404A Coil assembly, R404A, Fan Lt Control, Danfoss, GDM, 115V Hinge, pan cover, center Hinge, pan cover, left Hinge, pan cover, right Hinge, pin (for pan cover) Hinge kit, lo profile (left or right) Leg, 6", s/s Nut, acorn (for pan cover) Switch, rocker Thermostat, rail Valve, expansion (rail) Valve, solenoid (rail) F18PD48 *000-248-0037 *000-BN5-0040 2194824 2194938 *000-402-0056 *000-187-006B 3234645 *356-478-0038 3978014 3234290 2190154 3516135 Coil assembly, R404A, Fan Lt Condensing Assembly, 1/3-1/5 Stacked Control, Danfoss, GDM, 115V Control, Tstat, Danfoss, Etc1h-1 Cover Assembly, hinged, 6 pan, l/t Door Assembly, ref, 27x26, lt Leg, 6, s/s, removable Foot Panel, louver, 14.0, sw Cut, lh Shelf, wire, coated Support, shelf, plastic Switch, rocker, 20a/125v Thermometer, hanging, 4 F18PD72 *000-248-0030 *000-BN5-003Y 2194824 2194938 *000-402-0056 *000-187-006B *000-187-006A 3234645 *356-478-0039 3978014 3234290 2190154 3516135 Coil assembly, R404A Condensing Assembly, 1/2-1/5 Stacked Control, Danfoss, GDM, 115V Control, Tstat, Danfoss, Etc1h-1 Cover Assembly, hinged, 6pan, l/t Door Assembly, ref, 27x26, lt Door Assembly, ref, 27x26, rt Leg, 6, s/s, removable Foot Panel, louver, 18.0, sw Cut, lh Shelf, wire, coated Support, shelf, plastic Switch, rocker, 20a/125v Thermometer, hanging, 4 *Replacement part assemblies on pages 19-22. 18 For customer service, call (800) 733-8829, (800) 773-8821, Fax (989) 773-3210, www.delfield.com https://manual-hub.com/ Replacement Parts, continued F18RC 3516053 *000-248-0030 *000-BN5-0035 *000-BN5-0037 *000-BN5-0030 2194824 2193927 3234392 3234282 3234266 9321374 0160179 3234645 3977984 3977998 3978014 3977983 3234290 9321040 9321132 2190154 3516225 3516102 Coil, solenoid, 120V/50/60HZ (rail) Coil assembly, R404A Condensing unit, 1/2hp, R404a Condensing unit, 1/3hp, R404a Condensing unit, 1/4hp, R404a Control, Danfoss, GDM, 115V Control, pressure, low Hinge, pan cover, center Hinge, pan cover, left Hinge, pan cover, right Hinge, pin (for pan cover) Hinge Kit Leg, 6", s/s Shelf, 19" door Shelf, 24" door Shelf, 27" door Shelf, 32" door Shelf support, 1" blue Shelf support screw (coil side) Shelf support screw (wall side) Switch, rocker Valve, expansion (rail) Valve, solenoid (rail) F18 Series Service and Installation Manual 9321040 9321132 2190154 2194201 3516225 3516102 Shelf support screw (coil side) Shelf support screw (wall side) Switch, rocker Thermostat, rail Valve, expansion (rail) Valve, solenoid (rail) F18SC 030-209-0030 3516053 *000-248-0030 *000-248-0037 *000-BN5-0030 2194824 2193927 3234392 3234282 3234266 9321374 0420068 3234645 2190154 3516225 3516102 Angle, Coil, Top Baffle Coil, solenoid, 120V/50/60HZ (rail) Coil assembly, R404A Coil assembly, R404A, Fan Lt Condensing unit, 1/4hp, R404a Control, Danfoss, GDM, 115V Control, pressure, low Hinge, pan cover, center Hinge, pan cover, left Hinge, pan cover, right Hinge, pin (for pan cover) Hinge kit, lo profile (left or right) Leg, 6", s/s Switch, rocker Valve, expansion (rail) Valve, solenoid (rail) F18RR 3516053 *000-248-0030 *000-248-0037 2194824 3234392 3234282 3234266 9321374 0160179 3234645 3977984 3977998 3978014 3977983 3234290 Coil, solenoid, 120V/50/60HZ (rail) Coil assembly, R404A Coil assembly, R404A, Fan Lt Control, Danfoss, GDM, 115V Hinge, pan cover, center Hinge, pan cover, left Hinge, pan cover, right Hinge, pin (for pan cover) Hinge Kit Leg, 6", s/s Shelf, 19" door Shelf, 24" door Shelf, 27" door Shelf, 32" door Shelf support, 1" blue *Replacement part assemblies on pages 19-22. 19 For customer service, call (800) 733-8829, (800) 773-8821, Fax (989) 773-3210, www.delfield.com https://manual-hub.com/ F18 Series Service and Installation Manual Replacement Parts, continued F18SR 030-209-0030 3516053 *000-248-0030 *000-248-0037 2194824 3234392 3234282 3234266 9321374 0420068 3234645 2190154 2194201 3516225 3516102 Angle, Coil, Top Baffle Coil, solenoid, 120V/50/60HZ (rail) Coil assembly, R404A Coil assembly, R404A, Fan Lt Control, Danfoss, GDM, 115V Hinge, pan cover, center Hinge, pan cover, left Hinge, pan cover, right Hinge, pin (for pan cover) Hinge kit, lo profile (left or right) Leg, 6", s/s Switch, rocker Thermostat, rail Valve, expansion (rail) Valve, solenoid (rail) F18WC *000-248-0030 *000-248-0037 *000-BN5-0030 *000-BN5-0031 2194810 0160179 3234645 3977984 3977998 3978014 3977983 2190154 3234290 9321040 9321132 Coil assembly, R404A Coil assembly, R404A, Fan Lt Condensing unit, 1/4hp, R404a Condensing unit, 1/5hp, R404a Control, Danfoss, GDM, 115V Hinge Kit Leg, 6", s/s Shelf, 19" door Shelf, 24" door Shelf, 27" door Shelf, 32" door Switch, rocker Shelf support, 1" blue Shelf support screw (coil side) Shelf support screw (wall side) F18WR *000-248-0030 *000-248-0037 2194810 0160179 3234645 3977984 3977998 3978014 3977983 3234290 9321040 9321132 Coil assembly, R404A Coil assembly, R404A, Fan Lt Control, Danfoss, GDM, 115V Hinge Kit (left or right hinged) Leg, 6", s/s Shelf, 19" door Shelf, 24" door Shelf, 27" door Shelf, 32" door Shelf support, 1" blue Shelf support screw (coil side) Shelf support screw (wall side) *Replacement part assemblies on pages 19-22. 20 For customer service, call (800) 733-8829, (800) 773-8821, Fax (989) 773-3210, www.delfield.com https://manual-hub.com/ Replacement Part Assemblies 3 4 5 2 1 F18 Series Service and Installation Manual 1 2 34 5 6 8 9 7 Key Part Number - 000-249-0004 1 030-262-0001 2 2160023 3 2160024 4 030-260-0001 5 030-259-0000 6 3516271 7 265-261-0001 8 3516073 9 030-263-0001 - 2184318 - 2194808 - 2194809 1 Description Coil Assembly, Evap, Freezer Side, evaporator Fan, axiel Guard, fan, 4.7", SC120-W2 Top, frz, evaporator Front, enclosure Valve, expansion, R404a Pan, freezer evaporator Coil, Evaporator Back, evaporator Harness, coil, frz, male Probe, Defrost, Danfoss, Control Probe, Temp, Sensor, Danfoss 4 2 3 6 5 7 6 8 10 9 Key Part Number - 000-249-0006 1 030-262-0001 2 2160023 3 2160024 4 030-260-0001 5 030-259-0000 6 3516271 7 3516073 8 2194034 9 265-261-0001 10 030-263-0001 - 2194046 - 2194631 - 2184323 Description Coil Assembly, Freezer Evap, Remote Side, evaporator Fan, axiel Guard, fan, 4.7", SC120-W2 Top, frz, evaporator Front, enclosure Valve, expansion, R404a Coil, Evaporator Heater, Defrost Pan, freezer evaporator Back, evaporator Control, Limit, Fan Delay/Defrost Fuse, Defrost Heater, 7 Amp Harness, coil, frz, male, remote 1 2 4 3 5 6 7 9 8 7 Key Part Number - 000-248-0030 1 2160024 2 2160023 3 3516095 4 030-232-0003 5 3516273 6 030-233-0001 7 075-231-0033 8 030-234-0003 - 2184317 - 2194808 - 2194809 8 Description Coil Assembly, R404A, Ref Guard, fan, 4.7" Fan, axiel, 120V Coil, evaporator Back, evaporator, enclosure Expansion valve, 1/4, R-404a Side, coil, angled Drip pan, evaporator Front, coil Harness, coil Probe, Defrost, Danfoss, Control Probe, Temp, Sensor, Danfoss Key Part Number - 000-248-0037 1 2160024 2 2160023 3 3516095 4 030-232-0003 5 000-BNH-0030 6 030-233-0038 7 3516273 8 030-234-0003 9 030-233-0039 - 2184317 - 2194808 - 2194809 Description Coil Assembly, R404A, Ref, Fan Lt Guard, fan, 4.7" Fan, axiel, 120V Coil, evaporator Back, evaporator, enclosure Drip pan, evaporator Side, coil, angled, Rt, Blank Expansion valve, 1/4, R-404a Front, coil Side, Coil, Angled, Lt, 2Fan Harness, coil Probe, Defrost, Danfoss, Control Probe, Temp, Sensor, Danfoss 21 For customer service, call (800) 733-8829, (800) 773-8821, Fax (989) 773-3210, www.delfield.com https://manual-hub.com/ F18 Series Service and Installation Manual Replacement Part Assemblies, continued 2 3 4 1 1 5 2 3 4 5 6 8 Key Part Number - 000-BN5-0030 1 2160028 2 2160030 3 026-C58-0037 4 3526999 5 2194787 3516444 6 3516322 7 075-231-0030 8 3516454 7 Description Assembly, 1/4 HP Condensing Unit Fan, Axial, 5.5", 120V Guard, Fan, 6.0" Shroud, Condenser Coil Compressor, Danfoss, NF5.5CLX Start Capacitor Comp, Relay, Overload, NF5.5CLX Filter Dryer Condensate Pan Condenser Coil 5 4 3 2 1 6 7 8 6 8 Key Part Number - 000-BN5-0031 1 2160028 2 2160030 3 026-C58-0037 4 3526997 5 2194787 3516446 6 3516322 7 075-231-0030 8 3516454 7 Description Assembly, 1/5 Condensing Unit Fan, Axial, 5.5.", 120V Guard, Fan, 6.0" Shroud, Condenser Coil Compressor, Danfoss, TF4CLS Start Capacitor Comp, Relay, Danfoss Filter Dryer Condensate Pan Condenser Coil 1 2 3 9 Key Part Number Description - 000-BN5-0054 Assembly, 1/2HP Cond, Low, Hot gas 1 3516554 Blade, Fan, 9.00" 2 2160019 Guard, Fan, Wire 3 2162716 Motor, Fan, 16W, 115V, CW 4 3516324 Cutout, High Pressure 5 3527001 Compressor, SC12CLX.2,115/60HZ 6 3516322 Drier, Filter, (2)Inlet 7 2194789 Capacitor, Start, 240MFD 8 3516441 Relay, Comp, SC12CLX.2 9 3516455 Coil, Condenser, 1/2 HP - 024-034-0031 Pan, Comp, 18.00 4 Key Part Number - 000-BN5-0055 1 2160019 2162716 3516433 2 3527002 3516442 3 3516322 4 3516456 Description Assembly, 3/4 HP Cond, Low, Hot gas Guard, fan condenser Motor, condenser fan 16W, 155V Blade, fan 10" CW Compressor, SC18CLS.2, 115V60hz Capacitor, start, run assembly Filter drier Coil, condenser, 3/4hp 22 For customer service, call (800) 733-8829, (800) 773-8821, Fax (989) 773-3210, www.delfield.com https://manual-hub.com/ Replacement Part Assemblies, continued 6 5 4 3 2 1 1 7 F18 Series Service and Installation Manual 2 3 4 5 8 9 Key Part Number - 000-BN5-0035 1 3516554 2 2160019 3 2162716 4 3516462 5 3527026 6 3516331 7 3516322 8 075-231-0031 9 3516455 Description Assembly, 1/2HP Condenser, Med Condenser fan blade Condenser fan guard Condenser fan motor, 115V Capacitor, start-run assy Compressor, Danfoss, SC12MLX Hi pressure switch Filter Drier Pan, Condensate Condenser coil 2 3 7 4 8 5 6 1 6 7 8 9 Key Part Number - 000-BN5-0037 1 2160028 2 2160030 3 026-C58-0037 4 3527000 5 2194788 3516438 6 3516322 7 3516458 8 075-231-0030 9 3516454 Description Assembly, 1/3 Condensing Unit Fan, Axial, 5.5", 120V Guard, Fan, 6.0" Shroud, Condenser Coil Compress, Danfoss, NF7CLS Start Capacitor Relay, overload, compressor Filter Drier Receiver tank Pan, Condensate Condenser Coil 9 10 11 Key Part Number - 000-BN5-0053 1 2160028 2 2160030 3 3516053 4 3516102 5 3527000 6 3516438 2194788 7 000-998-0030 8 3516397 9 3516322 10 3516458 11 3516454 Description Assembly, 1/3HP Cond, w/rec, hg Fan, Axial, 5.5", 120V Guard, Fan, 6.0" Coil, Solenoid, 120V Valve, Solenoid, 1/4ODF Compressor, NF7.0,115/60HZ, Danfoss Relay, Comp, ovld Capacitor, Start, 320MFD High Pressure Assembly, 8Amp Accumulator Filter Drier, (2)Inlet Receiver Coil, Condenser 23 For customer service, call (800) 733-8829, (800) 773-8821, Fax (989) 773-3210, www.delfield.com https://manual-hub.com/ F18 Series Service and Installation Manual Replacement Part Assemblies, continued 000-BN5-003Y 3516457 3516433 2194789 2194787 3516454 3516455 3526997 3527001 3516322 2160020 2160019 2162717 2162513 3516193 3516446 3516441 3516225 Assembly, 1/2-1/5 Stacked, Blade, Fan, 7.25 Dia., Blade, fan, 25deg, 10", cw Capacitor, start, 240mfd Capacitor, start, 280mfd Coil, Condenser, 1/5, 1/4, Coil, Condenser, 1/2 Hp Compressor, 1/5hp, 115/60, r404a Compressor, sc12clx.2, 115/60hz, Drier, filter, (2)inlet Guard, Fan, 7.25 Guard, fan, wire Motor, fan, 9w, 115v, cw Motor, fan, 35w, blast Regulator, pressure, 1/2 Relay, Compressor, Danfoss Relay, compressor, sc12clx.2 Valve, expansion, frz, 1/4ton 000-BN5-0040 3516457 2194787 2194788 3516454 3526997 3527000 3516322 2160020 2162717 3516193 3516446 3516438 3516225 Assy, 1/3-1/5 Stacked, Blade, Fan, 7.25 Dia. Capacitor, start, 280mfd Capacitor, start, 320mfd Coil, Cond., 1/5, 1/4 Comp, 1/5hp, 115/60, r404a Comp, nf7cls, 115v/60hz Drier, filter, (2)inlet Guard, Fan, 7.25 Motor, fan, 9w,115v,cw Regulator, pressure, 1/2 Relay, Comp, Danfoss Relay, comp, ovld, nf7clx Valve, exp, frz, 1/4ton 359-478-003E 359-478-003D 356-478-0038 356-478-0039 Panel, louver, 15.0, ptb Panel, louver, 18.0, ptb Panel, louver, 14.0, sw Cut,lh Panel, louver, 18.0, sw Cut, lh 000-187-0081 000-187-0082 000-187-006B 000-187-006A 1701185 0420067 Door Assembly, ref, 27x26, rt, 430 Door Assembly, ref, 27x26, lt, 430 Door Assembly, ref, 27x26, lt Door Assembly, ref, 27x26, rt Gasket, door, 27, mark7 Hinge Kit 000-402-0054 000-402-0056 9321374 3234266 3234282 3234392 Cover Assembly, hinged, 6 Pan, ptl Cover Assembly, hinged, 6pan, l/t Pin, hinge, salad Pan Hinge, pan Cover, end, rh, Hinge, pan Cover, end, lh, Hinge, pan Cover, 24 For customer service, call (800) 733-8829, (800) 773-8821, Fax (989) 773-3210, www.delfield.com https://manual-hub.com/ F18 Series Service and Installation Manual Standard Labor Guidelines To Repair Or Replace Parts On Delfield Equipment Advice and recommendations given by Delfield Service Technicians do not constitute or guarantee any special coverage. · A maximum of 1-hour is allowed to diagnose a defective component. · A maximum of 1-hour is allowed for retrieval of parts not in stock. · A maximum travel distance of 100 miles round trip and 2-hours will be reimbursed. · Overtime, installation/start-up, normal control adjustments, general maintenance, glass breakage, freight damage, and/or correcting and end-user installation error will not be reimbursed under warranty unless pre-approved with a Service Work Authorization from Delfield. You must submit the number with the service claim. Labor Of 1-Hour Is Allowed To Replace: · Thermostat · Infinite Switch · Door Jamb Switch · Solenoid Coil · Hi-limit/Thermal Protector Switch · Fan Delay/Defrost Termination Switch · Compressor Start Components and Overload Protector · Defrost Timer · Thermometer · Gear Box · Contactor/Relay · Transformer · Evaporator/Condenser Fan Motor and Blade · Circulating Fan Motor and Blade · Microprocessor Control · Water Level Sensor/Probe · Door Hinges, Locks, and Gaskets · Condensate Element · Springs/Lowerator Labor Of 2 Hours To Replace: · Drawer Tracks/Cartridges · Pressure Control · Solenoid Valve · Defrost Element · Heating Element · Locate/Repair Leak Labor Of 3 Hours To Replace: · EPR or CPR Valve · Expansion Valve · Condenser or Evaporator Coil Labor Of 4 Hours To Replace: · Compressor This includes recovery of refrigerant and leak check. $55.00 maximum reimbursement for refrigerant recovery (includes recovery machine, pump, torch, oil, flux, minor fittings, solder, brazing rod, nitrogen, or similar fees.) Refrigerants: · R22 A maximum of $4.00/lb. or 25¢/oz. will be reimbursed. · R134A A maximum of $5.00/lb. or 31¢/oz. will be reimbursed. · R404A A maximum of $16.00/lb. or $1.00/oz. will be reimbursed. 25 For customer service, call (800) 733-8829, (800) 773-8821, Fax (989) 773-3210, www.delfield.com https://manual-hub.com/ F18 Series Service and Installation Manual Notes 26 For customer service, call (800) 733-8829, (800) 773-8821, Fax (989) 773-3210, www.delfield.com https://manual-hub.com/ Notes F18 Series Service and Installation Manual 27 For customer service, call (800) 733-8829, (800) 773-8821, Fax (989) 773-3210, www.delfield.com https://manual-hub.com/ Mt. Pleasant, MI Covington, TN Thank you for choosing Delfield! Help is a phone call away. Help our team of professional, courteous customer service reps by having your model number and serial number available at the time of your call (800) 733-8829. Model: _______________________ S/N: ______________________ Installation Date: _______________ For a list of Delfield's authorized parts depots, visit our website at www.delfield.com Register your Delfield warranty online. Go to www.delfield.com under the service tab to complete. 980 S. Isabella Rd., Mt. Pleasant, MI 48858, U.S.A. · (989) 773-7981 or (800) 733-8829 · Fax (989) 773-3210 · www.delfield.com Delfield reserves the right to make changes in design or specifications without prior notice. ©2013 The Delfield Company. All rights reserved. Printed in the U.S.A. DM18 07/13 9291454 https://manual-hub.com/