Turbo EC 200
Mixed-flow inline fans with EC-motors
Key Features
- Sound pressure level LpA at 3 m: 49 dB(A)
- Motor type: EC
- Impeller type: Mixed-flow
- Casing material: Plastik
- Installation in any position
Technical Specifications
Specification | Unit of measurement | Turbo EC 200 |
---|---|---|
Connected air duct size | mm | 200 |
Speed | - | 1 |
Phases | - | 1 |
Minimum supply voltage | V | 230 |
Maximum supply voltage | V | 230 |
Power supply frequency | Hz | 50/60 |
Rated power | W | 123 |
Unit current | A | 1.02 |
Maximum airflow | m³/h | 1040 |
Rotation speed at 50hz | - | - |
Sound pressure level LpA at 3 m | dB(A) | 49 |
Weight | kg | 3.95 |
Transported air temperature (max) | °C | 55 |
Transported air temperature (min) | °C | -25 |
Ingress protection rating | - | IPX4 |
Performance Data
Static Pressure vs. Airflow
This chart illustrates the relationship between static pressure (measured in Pascals, Pa) on the vertical axis and airflow (measured in cubic meters per hour, m³/h) on the horizontal axis. Multiple colored lines represent different operating voltages (from 1V to 10V). For each voltage setting, the static pressure capability decreases as the airflow rate increases.
Power Consumption vs. Airflow
This chart displays the power consumption (measured in Watts, W) on the vertical axis against airflow (measured in cubic meters per hour, m³/h) on the horizontal axis. Similar to the static pressure chart, distinct lines for each voltage setting (1V to 10V) show how power usage varies with airflow. Generally, higher airflow rates correspond to higher power consumption.
Dimensions
The fan unit has the following dimensions, indicated by labels on a schematic diagram:
- ØD (Diameter): 198 mm
- B (Width): 239 mm
- H (Height): 277.5 mm
- L (Length): 295.5 mm
- ØD1 (Diameter): 209 mm
Note: A visual diagram typically accompanies these measurements, showing the placement of ØD, B, H, L, and ØD1 on the fan housing.
Ecodesign Information
Specification | Details |
---|---|
Trademark | Blauberg |
Model | Turbo EC 200 |
Specific energy consumption (SEC) (kWh/(m²/a)) | Cold: 54.1 (A+), Average: 27.1 (B), Warm: 11.6 (E) |
Type of ventilation unit | Unidirectional |
Type of drive installed | Variable speed |
Type of heat recovery system | None |
Maximum flow rate (m³/h) | 910 |
Electric power input (W) | 123 |
Reference flow rate (m³/s) | 0.177 |
Reference pressure difference (Pa) | 50 |
Specific power input (SPI) (W/(m³/h)) | 0.094 |
Control typology | Local demand control |
Maximum external leakage rates (%) | 2.7 |
Declared typology | RVU UVU |
Sound power level (dB(A)) | 69 |
The annual electricity consumption (AEC) (kWh/a) | Cold: 50, Average: 50, Warm: 50 |
The annual heating saved (AHS) (kWh/a) | Cold: 5536, Average: 2830, Warm: 1280 |