Owner's Manual for Mircom models including: FX-2003-12NDS Network Fire Alarm Control Panel, FX-2003-12NDS, Network Fire Alarm Control Panel, Fire Alarm Control Panel, Alarm Control Panel, Control Panel, Panel
Mircom CAT-5941 FleX-Net FX-2003 12N Network Fire Alarm Control Panel (English) - Fire Alarm Resources - Free fire alarm PDF manuals, documents, installation instructions, and technical specifications
File Info : application/pdf, 7 Pages, 1.29MB
DocumentDocumentNETWORK FIRE ALARM CONTROL PANEL FX-2003-12NDS Features Description Mircom's FleX-Net Series is a powerful intelligent networkable fire alarm solution designed with many levels of flexibility to meet virtually any application of detection, control, notification and emergency communications. Features such as fire detection & alarm, audio/voice evacuation, BACnet, Boolean logic, networking and graphical work stations allow this modular solution to accommodate the simplest systems up to the most complex solutions With the addition of the Advance Protocol (AP), Fire/CO detection and 520 Hz support on both the addressable loop and through the audio/voice evacuation, Mircom's FleX-Net is poised to take you even farther into the future with expanded capabilities.. Designed for peer-to-peer network communications, the FX-2003-12NDS allows for a maximum of 63 nodes, while providing reliability, flexibility and expandability. Each base panel consists of one intelligent signaling line circuit (SLC) capable of supporting 159 analog Sensors and 159 addressable modules. In addition the base panel includes Four Style Z/Y (Class A/B) Notification Appliance Circuits and an easy to read and use, large 4 x 20 back-lit alphanumeric LCD display. The network configuration allows the FX-2003-12NDS control panel to be connected to a Mircom network to provide additional input circuits, visual zones, programmable notification appliance circuits, and relays. The network interface module allows the panels to communicate on a peer-to-peer network via a Proprietary Arcnet Network Communications protocol. Fire Alarm Control · 1 SLC loop expandable up to 9 · Each SLC Loop is capable of supporting 159 Analog Sensors and 159 Addressable Modules which can be wired in Style 6 or 7 (Class A) or Style 4 (Class B) · Four Style Z/Y (Class A/B) Notification Appliance Circuits rated at 1.7 Amps each · System has the ability to mix CLIP and AP devices on the same loop · Large easy to use and readable 4 by 20 character Back-lit LCD Display · English, French, Arabic* and Hebrew* language support (*supported by RAXN-LCDG Annunciator in place of main display) · Correlatable Switch Inputs which allow for multi-functional outputs · Four Status Queues for Alarm, Supervisory, Trouble and Monitor · Auxiliary relay contacts for Common Alarm, Supervisory and Trouble · Group bypass with built-in false alarm prevention technology · RS-232 output for remote system printer or CRT · Two Event History Logs; one for Alarm-related events and one for all events. · Supports 3 configuration files with "hot swap" support · Conventional Hardwire Adder Module expandability · Built-in Walk Test operation · Canadian Two Stage operation · Provision for two programmable modules · Configurable for Coded Operation · Intelligent Smoke Detector sensitivity levels · 3D graphical monitoring and control using Mircom's Open Graphic NavigatorTM · BACnet support · Advanced (Boolean) logic functions · Built-in Ethernet port · Remote diagnostics via a built-in web server · Audio/Voice Evacuation with 520Hz capability · UL listed for Smoke Control · HVAC Fan and Damper Control Network Features · Up to 63 nodes · Peer-to-peer network communications · Style 4 (Class B) or Style 6 or 7 (Class A) wiring configuration · Proprietary Arcnet Network Communications protocol · Supports copper and/or fiber optic network cable NYC Fire Dept S7010 S7010 7165-1477:111 COA# 6064 NOT TO BE USED FOR INSTALLATION PURPOSES. THIS INFORMATION IS FOR MARKETING PURPOSES ONLY AND NOT INTENDED TO DESCRIBE THE PRODUCTS TECHNICALLY. CATALOG NUMBER 5941 firealarmresources.com FleX-NetTM FX-2003-12NDS Network Series Fire Alarm Control Panels FX-2003-12NDS Compact Network Main Control Unit The FX-2003-12NDS Compact Network Main Control Unit complete with one Intelligent Signaling Line Circuit (Style 4, 6 or 7), Four Style Z/Y (Class A/B) Notification Appliance Circuits rated at 1.7 Amps each, a 4 line by 20 character back-lit LCD display and a 12 Amp Power Supply. The FX-2003-12NDS provides space for the FNC-2000 Network Controller Module, two internal adder modules and two programmable modules. UB-1024DS DOX-1024DSR UB-1024DS Universal Backbox The UB-1024DS Universal backbox houses the FX-2003-12NDS and provides space to mount up to 17 AH batteries. A DOX-1024DS(R) door is ordered separately. Dimensions (minus built-in trim ring): 26"H x 14.5"W x 4.2"D DOX-1024DS(R) Door The DOX-1024DS mounts on the UB-1024DS backbox. The door features the universal CAT-30 lock and is available in a white (DOX-1024DS) or red exterior (DOX-1024DSR). Fire Network Controller Modules Adder Loop Controller Modules ALCN-792MISO Isolated Quad Loop Controller Module The ALCN-792MISO Isolated Quad Loop Controller Module provides two Signaling Line Circuits (SLC) to the FleXNet system consisting of 159 Analog Sensors and 159 Addressable Modules per loop. The ALCN-792MISO can be expanded with the use of the ALCN-792D Daughter Board Module. The ALCN-792MISO occupies one module slot. FNC-2000 Fire Network Controller Module The FNC-2000 provides network capability to the FX-2003-12NDS panels. One Fire Network Controller Module is required per network node panel. In addition the FNC-2000 provides an interface for adding an optional FOM-2000-SP Fiber Optic Network Adder Module. The FNC-2000 mounts in the FX-2003-12NDS. FOM-2000-SP Fiber Optic Network Adder Module The FOM-2000-SP Fiber Optic Network Adder Module allows for the use of fiber optic cabling on the FleX-Net Series panels. It seamlessly connects to the interface on the FNC-2000 Fire Alarm Network Controller Module. ALCN-792D Daughter board for Isolated Quad Loop Controller Module The ALCN-792D Daughter Board provides an additional two SLC loops when connected to the ALCN-792MISO Isolated Quad Loop Controller Module. The daughter board mounts on top of the ALCN-792MISO. Electrical Specifications Primary Input Power Power Supply Ratings For NAC Circuits Battery Type Battery Charging Capability 120V 60Hz / 240V, 50Hz 4 Amps / 2 Amp (primary) 12 Amps. max. (secondary) 24VDC unfiltered, 10 Amps. max. Max. Voltage Drop Permitted (Class A = 3.3V, and Class B = 3.7V) 24VDC, Gel-Cell/Sealed Lead-Acid 17-65 AH batteries NOT TO BE USED FOR INSTALLATION PURPOSES. THIS INFORMATION IS FOR MARKETING PURPOSES ONLY AND NOT INTENDED TO DESCRIBE THE PRODUCTS TECHNICALLY. firealarmresources.com CAT. 5941 Page 2 of 7 Adder Hardwire Modules Adder Auxiliary Modules DM-1008A Eight Initiating Circuit Module The DM-1008A provides 8 Style B (Class B) or 4 Style D (Class A) Initiating Circuits configurable for Alarm, Supervisory or Trouble zones. The DM-1008A occupies one module slot in the FX-2003-12NDS. UDACT-300A Digital Alarm Communicator Module The UDACT-300A Digital Alarm Communicator Module allows the FX-2003-12NDS to transmit addressable point information to a central station. The UDACT-300A occupies one module slot in the FX-2003-12NDS. SGM-1004A Four Notification Appliance Circuit Module The SGM-1004A provides 4 Style Z/Y(Class A/B) Notification Appliance Circuits configurable as Silenceable or NonSilenceable. Each NAC circuit is rated at 1.7 Amps. The SGM-1004A occupies one module slot in the FX-2003-12NDS. PR-300 Polarity Reversal/City Tie Module The PR-300 Polarity Reversal/City Tie Module provides the system with a supervised City Tie (24 VDC/200 mA max.) and Polarity Reversal connection (24 VDC (open circuit), 8 mA max. (shorted)). The PR-300 occupies one module slot in the FX-2003-12NDS. Programmable Modules RM-1008A Eight Relay Circuit Module The RM-1008A provides the FX-2003-12NDS with eight individual configurable relays per module. Each relay provides one Form C contact rated at 28 VDC @1 Amp (resistive load) as well as a Green LED to indicate that the relay is active. The RM-1008A occupies one module slot in the FX-2003-12NDS. Graphics Software FDX-008W Fan Damper Control Module The FDX-008W Fan Damper Control Module provides individually programmed circuits which can be used for fan or damper control. The FDX-008W connects to the main panel or the RAXN-LCD and occupies one display position in the FX-2003-12NDS, BB-1000 or BB-5000 Series enclosures. Open Graphic Navigator (OpenGN) Open Graphic Navigator (OpenGN) is a centralized fire alarm management system that provides building or campus monitoring. As a powerful integration tool, OpenGN allows operators to monitor remote sites from multiple workstations or smart phones located anywhere in the world. OpenGN displays monitored buildings and campuses in both 2D and 3D representations, and is highly customizable. IPS-2424DS/IPS-4848DS Programmable Input Switches Module The IPS-2424DS/IPS-4848DS provides 24/48 programmable switches that can be configured for ancillary functions such as zone bypass or added common control functions. The IPS-2424DS/IPS-4848DS connects to the main panel or the RAXN-LCD when mounted remotely. The IPS-2424DS/IPS-4848DS occupies one display position in the FX-2003-12NDS, BB-1000 or BB-5000 Series enclosures. NOT TO BE USED FOR INSTALLATION PURPOSES. THIS INFORMATION IS FOR MARKETING PURPOSES ONLY AND NOT INTENDED TO DESCRIBE THE PRODUCTS TECHNICALLY. CAT. 5941 Page 3 of 7 firealarmresources.com Remote LCD Annunciators RAXN-LCD Remote LCD Annunciator The RAXN-LCD Remote LCD Annunciator is equipped with a 4 line x 20 character back-lit LCD display that provides the same functions as the main display on the fire alarm control panel. The RAXN-LCD occupies one display position in the BB-1000 or BB-5000 Series enclosures. Remote LED Annunciators RAXN-LCDG Remote Graphic LCD Annunciator The RAXN-LCDG Remote Graphic LCD Annunciator is equipped with a 24 line x 40 character back-lit graphical LCD display that is used to display 9 events per page. Each event is displayed over 2 lines with 40 characters per line allowing emergency information to be displayed in an easy to read format. The RAXN-LCDG occupies one display position in the BB-1000 or BB-5000 Series enclosures. RAM-1032TZDS Main Remote LED Annunciator The RAM-1032TZDS Main Remote LED Annunciator provides common annunciator functions and 32 points of LED annunciation. The RAM-1032TZDS has indicators for A.C. On, Common Trouble and Signal Silence and controls for System Reset, Lamp Test, Fire Drill, Buzzer Silence and Signal Silence. The RAM-1032TZDS occupies one display position in the BB-1000 or BB-5000 enclosures. Graphic Annunciator Driver Modules RAX-1048TZDS Programmable LED Annunciator Module The RAX-1048TZDS Programmable LED Annunciator Module provides 48 programmable bi-colored LEDs. The RAX-1048TZDS connects to the main panel or either the RAXN-LCD or RAM-1032TZDS when mounted remotely. The RAX-1048TZDS occupies one display position in the FX-200312NDS,BB-1000 or BB-5000 Series enclosures. MGD-32 Master Graphic Driver Module The MGD-32 Master Graphic Driver Module provides common control inputs for the common control switches such as System Reset, Signal Silence, Auxiliary Disconnect, Fire Drill, Lamp Test, Acknowledge and General Alarm. The MGD-32 can also drive up to 32 supervised outputs. These output points are capable of driving LEDs or incandescent lamps. The MGD-32 mounts in a graphic annunciator wallbox or in the BB-5000 enclosures. An external power supply is required for incandescent lamps and lamp test. AGD-048 Adder Graphic Driver Module The AGD-048 Adder Graphic Driver Module can be used with the MGD-32 to support an additional 48 supervised outputs. The AGD-048 mounts in a graphic annunciator wallbox or in the BB-5000 enclosures. Dimensions for Annunciator Module Enclosures Model BB-1001D/DR/DB/DS BB-1002D/DR/DB/DS BB-1003D/DR/DB/DS BB-1008D/DR/DB BB-1012D/DR/DB Dimensions 9"H x 12.75"W x 1.85"D 18"H x 12.75"W x 1.85"D 26.4"H x 12.75"W x 1.85"D 33"H x 22.5"W x 1.85"D 45"H x 22.5"W x 1.85"D NOT TO BE USED FOR INSTALLATION PURPOSES. THIS INFORMATION IS FOR MARKETING PURPOSES ONLY AND NOT INTENDED TO DESCRIBE THE PRODUCTS TECHNICALLY. CAT. 5941 Page 4 of 7 firealarmresources.com Typical FleX-NetTM FX-2003-12NDS Networked System Configuration RS-485 RAXN-LCD in a BB-1001DR Node 1 FX-2003-12NDS in a UB-1024DS backbox with a DOX-1024DSR door Ethernet Node 5 FX-2003-12NDS in a UB-1024DS backbox with a DOX-1024DSR door Class `A' (Style 7) wiring OpenGN Graphics Software Node 2 FX-2003-12NDS in a UB-1024DS backbox with a DOX-1024DSR door RS-485 RAXN-LCD in a BB-1001DR Node 4 FX-2003-12NDS in a UB-1024DS backbox with a DOX-1024DSR door Class `B' (Style 4) wiring RS-485 Node 3 FX-2003-12NDS in a UB-1024DS backbox with a DOX-1024DSR door RAXN-LCD and two RAX-1048TZDS in a BB-1003DR Current Consumption Model Number FX-2003-12NDS ALCN-792MISO ALCN-792MISO/D FNC-2000 FOM-2000-SP DM-1008A Description Network Compact Main Control Unit (12 Amp) Isolated Dual Analog Loops Isolated Quad Analog Loops Fire Network Controller Module Fiber Optics Module 8 Initiating Circuit Module Standby 0.310 0.130 0.130 0.190 0.015 0.080 SGM-1004A RM-1008A FDX-008W UDACT-300A PR-300 RAX-1048TZDS 4 Notification Appliance Circuit Module 8 Relay Circuit Module Fan Damper Control Module Dialer Module City Tie Module Adder Annunciator Chassis 0.060 0.025 0.015 0.045 0.035 0.022 RAM-1032TZDS MGD-32 AGD-048 IPS-2424DS IPS-4848DS Adder Annunciator Chassis Main Graphic Driver Module Adder Graphic Driver Module Programmable Input Switches Module Programmable Input Switches Module 0.050 0.035 0.035 0.010 0.010 NOT TO BE USED FOR INSTALLATION PURPOSES. THIS INFORMATION IS FOR MARKETING PURPOSES ONLY AND NOT INTENDED TO DESCRIBE THE PRODUCTS TECHNICALLY. firealarmresources.com Alarm 0.733 0.145 0.145 0.0190 0.015 1 zone active: 0.125 2 zone active: 0.170 4 zone active: 0.275 6 zone active: 0.370 8 zone active: 0.465 0.258 0.150 0.035 0.120 0.300 1 zone active: 0.026 2 zone active: 0.030 3 zone active: 0.035 4 zone active: 0.039 48 zone active: 0.262 32 zone active: 0.300 1.6 # of LEDs x 4mA 0.015 0.022 CAT. 5941 Page 5 of 7 Ordering Information Model Description Network Fire Alarm Control Panel FX-2003-12NDS UB-1024DS Network Compact Main Control Unit with 12 Amp power supply. Mounts in the UB-1024DS backbox. Universal black backbox. Requires DOX-1024DS(R) door. DOX-1024DS White door for UB-1024DS backbox DOX-1024DSR Red door for UB-1024DS backbox Network Controller Modules FNC-2000 FOM-2000-SP Fire Network Controller Module Fiber Optic Network Adder Module Adder Loop Controller Modules ALCN-792MISO Network Isolated Quad Loop Controller Module ALCN-792D Daughter board for ALC-792MISO Isolated Quad Loop Controller Module Adder Hardwire Modules DM-1008A Eight Class B (Style B) or 4 Class A (Style D) Initiating Circuit Module SGM-1004A Four Class A/B (Style Z/Y) Notification Appliance Circuit Module (Rated at 1.7 Amps per circuit) RM-1008A Eight Relay Circuit Module c/w eight form C relays (Rated for 28 VDC @ 1 Amp max. per relay) Adder Auxiliary Modules UDACT-300A PR-300 Digital Alarm Communicator Transmitter/Dialer Module Polarity Reversal and City Tie Module Remote Annunciators RAXN-LCD Remote LCD Annunciator RAXN-LCDG Remote Graphic LCD Annunciator RAM-1032TZDS RAX-1048TZDS Main Remote LED Annunciator c/w 32 Bi-Colored LEDs Programmable LED Annunciator Module c/w 48 Bi-Coloured LEDs and 48 Trouble LEDs Programmable Modules IPS-2424DS Programmable Input Switches Module c/w 24 selector switches and 24 bi-coloured LEDs IPS-4848DS Programmable Input Switches Module c/w 48 selector switches and 48 bi-coloured LEDs FDX-008W Fan Damper Control Module Enclosures for Remote Annunciators / Programmable Modules BB-1001D Remote Enclosure. Houses one module. Add suffix "R" for red, "S" for stainless steel, and "B" for black door. BB-1002D BB-1003D Remote Enclosure. Houses two modules. Add suffix "R" for red, "S" for stainless steel, and "B" for black door. Remote Enclosure. Houses three modules. Add suffix "R" for red, "S" for stainless steel, and "B" for black door. BB-1008D Remote Enclosure. Houses eight modules. Add suffix "R" for red and "B" for black door. BB-1012D Remote Enclosure. Houses twelve modules. Add suffix "R" for red and "B" for black door. Graphic Driver Modules MGD-32 AGD-048 Main Graphic Driver Module c/w 32 Supervised Outputs Adder Graphic Driver Module c/w 48 Supervised Outputs Graphics Software OGN-FLSLIC-ONE Single Fire Alarm Control Panel License (Price per connection) Requires: OGN-KEY (sold seperately) Contact us for non-Mircom panel connections OGN-FLSLIC-EXP Fire Alarm Control Panel License for 2-9 Connections (Price per connection) Requires: OGN-KEY(sold seperately) Contact us for non-Mircom panel connections OGN-FLSLIC-STD Fire Alarm Control Panel License for 10-99 Connections (Price per connection) Requires: OGN-KEY (sold seperately) Contact us for non-Mircom panel connections NOT TO BE USED FOR INSTALLATION PURPOSES. THIS INFORMATION IS FOR MARKETING PURPOSES ONLY AND NOT INTENDED TO DESCRIBE THE PRODUCTS TECHNICALLY. CAT. 5941 Page 6 of 7 firealarmresources.com OGN-FLSLIC-ENT OGN-KEY Accessories UIMA4 MGC-CONFIG-KIT4 Fire Alarm Control Panel License for 100+ Connections (Price per connection) Requires: OGN-KEY (sold seperately) Contact us for non-Mircom panel connections OGN License Key Stick Interface for Configuring MGC Fire Panels Fire Panel Configuration KIT with UIMA4. Canada 25 Interchange Way Vaughan, Ontario L4K 5W3 Telephone: (905) 660-4655 Fax: (905) 660-4113 www.mircom.com U.S.A. 4575 Witmer Industrial Estates Niagara Falls, NY 14305 Toll Free: (888) 660-4655 Fax Toll Free: (888) 660-4113 THIS INFORMATION IS FOR MARKETING PURPOSES ONLY AND NOT INTENDED TO DESCRIBE THE PRODUCTS TECHNICALLY. For complete and accurate technical information relating to performance, installation, testing and certification, refer to technical literature. This document contains intellectual property of Mircom. The information is subject to change by Mircom without notice. Mircom does not represent or warrant correctness or completeness. firealarmresources.com CAT. 5941 Rev. 10