User Manual for WISILICA models including: WCAD1N, 2AG4N-WCAD1N, 2AG4NWCAD1N, Radiar AFD1 WCADIN Dali Fixture Controller, Radiar AFD1, WCADIN Dali Fixture Controller
WiSilica, Inc. WCAD1N Radiar AFD1 2AG4N-WCAD1N 2AG4NWCAD1N wcad1n
File Info : application/pdf, 11 Pages, 1.44MB
DocumentDocumentRadiar AFD1 Radiar AFD1 is a BLE5.2 controllable, Nordic based DALI controller. It operates on 90-277 VAC input voltage range and can be connected to 1 DALI LED driver. This device also has a 12 VDC auxiliary output to power the sensors. Table of Contents Radiar AFD1 1. Features .................................................................................................................................................................. 3 2. Specifications .......................................................................................................................................................... 3 3. Device Dimensions.................................................................................................................................................. 5 4. Wire Description ..................................................................................................................................................... 6 5. Antenna Information .............................................................................................................................................. 7 6. Wiring Diagram ....................................................................................................................................................... 8 7. Warning .................................................................................................................................................................. 8 8. Ordering Information.............................................................................................................................................. 9 9. Compatible Devices ................................................................................................................................................ 9 2 1. Features DALI supporting up to 1 slave device BLE5.2 based non-flooding intelligent communication 12 VDC auxiliary output Zero downtime Over-the-Air (OTA) firmware updates Compact form factor for easy integration into luminaires 2. Specifications Electrical Min. Typ. Max. Unit Input Voltage Input Current Power Consumption 90 277 Vac 10 mA 2 W Supply Frequency 50 _ 60 Hz Inrush Current 4 A Surge Transient Protection 4 kV Standby Consumption 7.71 mA Connection Distance (Device to Device by Mesh) 30 m DALI Number of Slaves Bus Supply Voltage Bus Supply Current Dimming Range Protocol Chipset used Dimming Curve Min. Typ. Max. Unit 1 pc 11 12 13 V 2 mA 0 100 % 101 / 103 / 207 / 209 Linear / Logarithmic Radiar AFD1 Remarks Rated Input voltage @ 230 V Active Power L-N, Bi wave @Rated input voltage In an open office environment (Line of Sight) Remarks DALI2.0 Nordic Logarithmic by default 3 Bluetooth Frequency Range TX Power RX sensitivity Min. Typ. Max. Unit 2400 2483 MHz 8 dBm -92 dBm Radiar AFD1 Remarks With 150mm external wire antenna Environmental Min. Typ. Max. Unit Ambient Temperature -20 Relative Humidity 20 50 ºC 85 % Mechanical Dimensions Dimensions Net Weight Net Weight Min. Typ. Max. Unit 43 x 35 x 20 mm 1.7 x 1.4 x 0.8 inch 30.00 g 1.06 oz Remarks Remarks L x W x H L x W x H In gram In ounce 4 3. Device Dimensions Radiar AFD1 Top View: 43mm x 35mm x 20mm (L x W x H). Case Material: White coloured V0 PC Radiar AFD1 5 4. Wire Description Radiar AFD1 SI.NO 1 2 3 4 5 6 NAME Line Neutral DALI DALI 12VDC Ground COLOR Black White Blue Grey Red Grey GAUGE 20 AWG 20 AWG 28 AWG 28 AWG 28 AWG 28 AWG RATING 600V 600V 300V 300V 300V 300V DESCRIPTION 100-277VAC Common neutral DALI+ DALI ·12 VDC auxiliary output Common ground 6 5. Antenna Information 150mm wire antenna Radiar AFD1 Frequency range Impedance VSWR Return loss Gain(peak) Cable loss Polarization Antenna Properties 2.4 GHz-2.5GHz 50 Nominal 1.92:1 Max -10 dB Max 2 dBi 0.3 dBi Max Linear 7 6. Wiring Diagram 1) Connecting DALI drivers to the Radiar AFD1 controller Radiar AFD1 7. Warning 1. To prevent the device from any defect, please handle and store it with care. - Do not drop or give shock. - Do not store in very humid location or at extreme temperature. - Do not open or disassemble the product. 2. Static electricity or surge voltage may damage the components inside device, as such please observe proper antielectrostatic working process. - People handing the device should be well grounded (e.g. using ESD wrist band) and wear antistatic working clothes and gloves. - All related devices and instruments in the production line should be well grounded (e.g. working table, measuring equipment, assembly jigs). 3. Observe the correct polarity of output terminal. 4. Avoid input voltage exceeds the maximum rating, which will cause damage to the circuit and result in malfunction. 5. Do not block any ventilation openings. Install in accordance with the manufacturer's instructions. 6. Refer all servicing to qualified personnel. Servicing is required when the apparatus has been damaged in any way, such as power supply cord or plug is damaged, liquid has been spilled or objects have fallen into the apparatus has been exposed to rain or moisture, does not operate normally, or has been dropped. 7. To reduce the risk of fire or electric shock, do not expose this apparatus to rain or moisture. The apparatus shall not be exposed to dripping or splashing and that objects filled with liquids, such as vases, shall not be placed on apparatus. 8 Radiar AFD1 8. To prevent injury, this apparatus must be securely attached to the floor/wall in accordance with the installation instruction. 8. Ordering Information Product Code WCAD1N Product Name Radiar AFD1 Product Description 1 Slave DALI Controller Communication BLE5.2 Voltage Rating 90-277V AC 9. Compatible Devices iOS - iPhone & iPad (version 9.0 and above) Android- almost all device (version 6.0 and above) Register and view our knowledge base for commissioning and control information Link - https://share.hsforms.com/1LxreXGbFQayBESIZg48_ng4ocng Download our mobile application in the following link Search Lumos Controls App on the App Store / Play Store for iOS / Android device or use the below link Android: https://play.google.com/store/apps/details?id=com.wisilica.Home&hl=en_US iOS: Lumos Controls on the App Store (apple.com) 9 Radiar AFD1 Version 1.0 10 FCC Statement This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures: ·Reorient or relocate the receiving antenna. ·Increase the separation between the equipment and receiver. ·Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. ·Consult the dealer or an experienced radio/TV technician for help. Caution: Any changes or modifications to this device not explicitly approved by manufacturer could void your authority to operate this equipment. This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. RF Exposure Information This equipment complies with FCC radiation exposure limits set forth for an uncontrolled environment. This equipment should be installed and operated with minimum distance 20cm between the radiator and your body.