User Manual for NUMERIC models including: 2000 HR-V, 2000 HR-V Digital In Built Battery, Digital In Built Battery, Built Battery, Battery

[PDF] USER MANUAL - Numeric UPSwww.numericups.com › sites › files

USER MANUAL

6 févr. 2024 — This manual contains detailed instructions on how to use, install and operate this product. Disclaimer. The contents of this manual are bound to change without ...

Digital 2000 HR-V IBB | Numeric UPS


File Info : application/pdf, 8 Pages, 883.09KB

PDF preview unavailable. Download the PDF instead.

20230921 Digi2000HRv-IBB UM 06WR
USER MANUAL
DIGITAL 2000 HR-V
IN-BUILT BATTERY

NEW ENERGY TO POWER

www.numericups.com

CONGRATULATIONS!
We are delighted to welcome you to our family of customers. Thank you for choosing Numeric as your reliable power solution partner, you now have access to our widest network of 250+ service centers in the country. Since 1984, Numeric has been enabling its clients to optimize their business with top-notch power solutions that promise seamless and clean power with controlled environmental footprints. We look forward to your continued patronage in the years to come. This manual contains detailed instructions on how to use, install and operate this product.
Disclaimer
The contents of this manual are bound to change without prior notice. We have exercised reasonable care to give you an error-free manual. Numeric disclaims liability for any inaccuracies or omissions that may have occurred. If you find information in this manual that is incorrect, misleading or incomplete, we would appreciate your comments and suggestions. Before you begin the installation of the product, please read this manual thoroughly. The warranty of this product is null and void, if the product is abused/misused.
INTRODUCTION
This UPS is a compact unit which combines both the benefits of UPS and inverter for long-time operation. It can accept input voltage over a wide range and provide stable and pure power source to the connected devices such as personal computer, monitor and other computer peripherals, communication & consumer electronic products. · Simulated sine wave output · Ensuring high reliability through microprocessor-enabled controls · Boost and buck AVR for voltage stabilization · Selectable charging current · Auto restart while AC is recovering · Off-mode charging · Cold start function · In-built battery · Ease of installation
2

IMPORTANT SAFETY INSTRUCTIONS
Save these instructions: This manual contains important instructions for this UPS that should be followed during installation and maintenance of the UPS and batteries.

· CAUTION! Do not drop any metal tool on the batteries. It could spark or short-circuit the batteries and could cause an explosion.
· CAUTION! Remove personal metal items such as rings, bracelets, necklaces and watches when working with batteries. Batteries can produce a short-circuit current high enough to melt metal, and could cause severe burns.
· CAUTION! Avoid touching eyes while working near batteries.
· CAUTION! Have plenty of fresh water and soap nearby in case battery acid contacts skin, clothing or eyes.
· CAUTION! NEVER smoke or allow a spark or flame in vicinity of a battery.
· CAUTION! If a remote or automatic generator start system is used, disable the automatic starting circuit or disconnect the generator to prevent accident during servicing.
· CAUTION! The unit is designed for indoor use. Do not expose this unit to rain, snow or liquids of any type.
· CAUTION! To reduce risk of injury, only use qualified batteries from qualified distributors or manufacturers. Any unqualified batteries may cause damage and injury. Do NOT use old or expired batteries. Please check the battery type and date code before installation to avoid damage and injury.
· CAUTION! Do not disassemble the unit. Contact with the qualified service center when service or repair is required.

WARNING!
Provide ventilation to outdoors from the battery compartment. The battery enclosure should be designed to prevent accumulation and concentration of hydrogen gas at the top of the compartment.
· CAUTION! Use insulated tools to reduce the chance of short-circuit when installing or working with the inverter, the batteries, or other equipments attached to this unit.
WARNING!
This equipment contains electronic components, which can produce arcs or sparks. To prevent fire or explosion do not install in compartments containing batteries or Flammable materials or in locations that require ignition protected equipment. This includes any space containing gasoline-powered machinery, fuel tanks, or joints, fittings, or other connection between components of the fuel system.

3

SYSTEM DESCRIPTION
Digital 2000 HR-V in-built 28 AH (x2)
1 2
Front panel 1. LED Display 2. Power Switch

3
5 4
ON
6
OFF
Back panel 3. AC Input 4. Output Sockets 5. Circuit Breaker 6. Battery Breaker

4

INSTALLATION AND OPERATION

1. Inspection
NOTE: Before installation, please inspect the unit. Be sure that nothing inside the package is damaged.

Checking Package Contents
You should receive the following items inside the package. · UPS Unit with Battery

Connect Internal Battery
The rating of the DC Breaker must be according to the UPS battery current (50 Amp). Keep the Battery Breaker ON.
Note: For the user operation safety, we strongly recommend that you should use tapes to isolate the battery terminals before operating the unit.

Table 2:

Model

Nominal Battery DC Voltage

Digital 2000 HR-V 24 VDC

Connect to Utility and Charge
Plug in the AC input cord to the wall outlet. The unit will automatically charge the connected internal battery even though the unit is off.
Note: Circuit Breaker rating of the Branch Circuit supplied from the Mains Input panel sizing must be 20A/250VAC in accordance with National Electrical Codes and Standards as per schematic. (Based on N.E.C NFPA 70 -2014; Reference: Article 240)

Mains Power Panel Input power

N

cord from UPS

20A breaker

L

UPS

Input power cable

Load

Connect to Device
Simply plug devices to battery supplied sockets. During power failure, it will provide continuous power to connected devices.

5

SPECIFICATIONS

MODEL Capacity VA/W INPUT Voltage Voltage range Frequency range OUTPUT AC Voltage regulation (Battery mode) Frequency Range (Battery mode) Transfer time Waveform (Battery mode) Outlets BATTERY Battery capacity (In-built) Battery voltage Floating charging voltage Recharge time (to 90%) Maximum charge current DISPLAY Display PROTECTION Protection ALARM Battery mode Low battery Overload Fault PHYSICAL Dimensions (WxDxH) (mm) Net weight (Kgs) ENVIRONMENT Noise level at 1 m (dBA) Operating temperature Protection index Relative humidity (%) Storage temperature STANDARDS Safety Standards

DIGITAL 2000 HR­V 2000 VA/1200 W
230 VAC 140 ­ 300 VAC 50 Hz
230 V +/- 10% 50 Hz +/- 1 Hz Typical 4 ­ 8 ms Simulated sinewave 4 x India type 6 Amps
28AH / 26AH 24 VDC 27.4 VDC +/- 1.0 VDC 4 hours 5A
LED display
Discharge, Overcharge and Overload protection
Sounding every 10 seconds Sounding every second Sounding every 0.5 seconds Continuously sounding
200 X 410 X 467 36.5
Less than 40 dBA 0 ºC to +40 ºC IP 20 0% to 95% (non-condensing) -10 ºC to +50 ºC
IS 16242 (Part1): 2014 / IEC 62040-1:2008

*Product specifications are subject to change without further notice

6

TROUBLE SHOOTING
Use the table below to solve minor problems.

Problem

Possible cause

Utility power is normal but the unit is in battery mode.

AC input power cord is not connected well.
Input breaker is activated.

When power fails,
the backup time is shortened.

The unit is overloaded.
Battery voltage is too low.
Battery capacity is not full even after charging the unit for at least 8 hours.

The unit is not turned on.

Nothing displays on
the front panel when
the utility power is normal.

Battery is not connected well.
Battery defect.

Battery voltage is too low.

Remedy
Check AC input power connection.
Reset the input breaker. Remove some non-critical loads. Charge the unit at least 8 hours.
Check the date code of the battery. If the batteries are too old, replace the batteries.
Press power switch to turn on the unit. Check the Internal battery cable and terminal. Make sure all the battery connections to the unit are all correct. Replace the batteries. Charge the unit at least 8 hours.

IMPORTANT SAFETY WARNING
As dangerous voltages are present within the UPS, only NUMERIC technicians are permitted to open the UNIT to replace the failed / dead Batteries. Failure to observe this could result in electric shock risk and invalidation of any implied warranty.

7

Head Office
10th Floor, Prestige Center Court, Office Block, Vijaya Forum Mall, 183, N.S.K Salai, Vadapalani, Chennai - 600 026. Phone: +91 44 4656 5555
Regional Offices
New Delhi B-225, Okhla Industrial Area, 4th Floor, Phase-1, New Delhi - 110 020. Phone: +91 11 2699 0028
Kolkata Bhakta Tower, Plot No. KB22, 2nd & 3rd Floor, Salt Lake City, Sector - III, Kolkata - 700 098. Phone : +91 33 4021 3535 / 3536
Mumbai C/203, Corporate Avenue, Atul Projects, Near Mirador Hotel, Chakala, Andheri Ghatkopar Link Road, Andheri (East), Mumbai - 400 099. Phone : +91 22 3385 6201
Chennai 10th Floor, Prestige Center Court, Office Block, Vijaya Forum Mall, 183, N.S.K Salai, Vadapalani, Chennai - 600 026. Phone : +91 44 3024 7236 / 200
Branch Offices
Chandigarh SCO 4, First Floor, Sector 16, Panchkula, Chandigarh - 134 109. Phone : +91 93160 06215
Dehradun Unit-1 and 2, Chakrata Road, Vijay Park Dehradun ­ 248001. Uttrakhand Phone : +91 135 661 6111
Jaipur Plot No. J-6, Scheme-12B, Sharma Colony, Bais Godown, Jaipur - 302 019. Phone : +91 141 221 9082

Lucknow 209/B, 2nd Floor, Cyber Heights, Vibhuti Khand, Gomti Nagar, Lucknow - 226 018. Phone : +91 93352 01364
Bhubaneswar N-2/72 Ground Floor, IRC Village, Nayapally, Bhubaneswar - 751 015. Phone: +91 674 255 0760
Guwahati House No 02, Rajgarh Girls High School Road (Behind Rajgarh Girls High School), Guwahati - 781 007. Phone : +91 361 245 0322/96000 87171
Patna 405, Fraser Road, Hemplaza, 4th Floor, Patna - 800 001. Phone : +91 612 220 0657
Ranchi 202 & 203, 2nd Floor, Sunrise Forum, Bardwan Compound, Lalpur, 2nd Floor, Ranchi - 834 001. Phone : + 91 98300 62078
Ahmedabad A-101/102, Mondeal Heights, Beside Hotel Novotel, Near Iscon Circle, S G Highway, Ahmedabad - 380 015. Phone : +91 79 6134 0555
Bhopal Plot No. 2, 221, 2nd Floor, Akansha Complex, Zone-1, M.P.Nagar, Bhopal­ 462 011. Phone : +91 755 276 4202
Nagpur Plot.No.174, H.No.4181/C/174, 1st Floor, Loksewa Housing Society, Near Dr. Umathe & Mokhare College, Bhamti Road, Lokseva Nagar, Nagpur - 440 022. Phone : +91 712 228 6991 / 228 9668

Pune Pinacle 664 park avenue, 8th floor, Plot no 102+103, CTS No. 66/4, Final, 4, Law College Rd, Erandwane, Pune, Maharashtra - 411 004. Phone : +91 98225 36680
Bengaluru No-58, First Floor, Firoze White Manor, Bowring Hospital Road, Shivajinagar, Bangalore -560 001. Phone : +91 80 6822 0000
Coimbatore No. B-15, Thirumalai Towers, No. 723, 1st Floor, Avinashi Road, Coimbatore - 641 018. Phone : +91 422 420 4018
Hyderabad Prestige Phoenix Building, 1st Floor, Survey no. 199, No. 6-3-1219/J/101 & 102, Uma Nagar, Opposite to Begumpet Metro Station Begumpet 500016 Phone: +91 40 4567 1717/2341 4398/2341 4367
Kochi Door No. 50/1107A9, JB Manjooran Estate, 3rd Floor, Bypass Junction, Edappally, Kochi ­ 682 024. Phone : +91 484 6604 710
Madurai 12/2, DSP Nagar, Dinamalar Avenue, Madurai - 625 016. Phone : +91 452 260 4555

NP/DSG/UM/10004/VER01

Sales - enquiry.numeric@numericups.com Service - support.numeric@numericups.com Contact us.: 0484-3103266 / 4723266 www.numericups.com



References

Adobe PDF Library 15.0 Adobe InDesign 14.0 (Windows)