User Manual for NUMERIC models including: 2000 HR-V, 2000 HR-V Digital In Built Battery, Digital In Built Battery, Built Battery, Battery
6 févr. 2024 — This manual contains detailed instructions on how to use, install and operate this product. Disclaimer. The contents of this manual are bound to change without ...
Digital 2000 HR-V IBB | Numeric UPS
File Info : application/pdf, 8 Pages, 883.09KB
DocumentDocumentUSER MANUAL DIGITAL 2000 HR-V IN-BUILT BATTERY NEW ENERGY TO POWER www.numericups.com CONGRATULATIONS! We are delighted to welcome you to our family of customers. Thank you for choosing Numeric as your reliable power solution partner, you now have access to our widest network of 250+ service centers in the country. Since 1984, Numeric has been enabling its clients to optimize their business with top-notch power solutions that promise seamless and clean power with controlled environmental footprints. We look forward to your continued patronage in the years to come. This manual contains detailed instructions on how to use, install and operate this product. Disclaimer The contents of this manual are bound to change without prior notice. We have exercised reasonable care to give you an error-free manual. Numeric disclaims liability for any inaccuracies or omissions that may have occurred. If you find information in this manual that is incorrect, misleading or incomplete, we would appreciate your comments and suggestions. Before you begin the installation of the product, please read this manual thoroughly. The warranty of this product is null and void, if the product is abused/misused. INTRODUCTION This UPS is a compact unit which combines both the benefits of UPS and inverter for long-time operation. It can accept input voltage over a wide range and provide stable and pure power source to the connected devices such as personal computer, monitor and other computer peripherals, communication & consumer electronic products. · Simulated sine wave output · Ensuring high reliability through microprocessor-enabled controls · Boost and buck AVR for voltage stabilization · Selectable charging current · Auto restart while AC is recovering · Off-mode charging · Cold start function · In-built battery · Ease of installation 2 IMPORTANT SAFETY INSTRUCTIONS Save these instructions: This manual contains important instructions for this UPS that should be followed during installation and maintenance of the UPS and batteries. · CAUTION! Do not drop any metal tool on the batteries. It could spark or short-circuit the batteries and could cause an explosion. · CAUTION! Remove personal metal items such as rings, bracelets, necklaces and watches when working with batteries. Batteries can produce a short-circuit current high enough to melt metal, and could cause severe burns. · CAUTION! Avoid touching eyes while working near batteries. · CAUTION! Have plenty of fresh water and soap nearby in case battery acid contacts skin, clothing or eyes. · CAUTION! NEVER smoke or allow a spark or flame in vicinity of a battery. · CAUTION! If a remote or automatic generator start system is used, disable the automatic starting circuit or disconnect the generator to prevent accident during servicing. · CAUTION! The unit is designed for indoor use. Do not expose this unit to rain, snow or liquids of any type. · CAUTION! To reduce risk of injury, only use qualified batteries from qualified distributors or manufacturers. Any unqualified batteries may cause damage and injury. Do NOT use old or expired batteries. Please check the battery type and date code before installation to avoid damage and injury. · CAUTION! Do not disassemble the unit. Contact with the qualified service center when service or repair is required. WARNING! Provide ventilation to outdoors from the battery compartment. The battery enclosure should be designed to prevent accumulation and concentration of hydrogen gas at the top of the compartment. · CAUTION! Use insulated tools to reduce the chance of short-circuit when installing or working with the inverter, the batteries, or other equipments attached to this unit. WARNING! This equipment contains electronic components, which can produce arcs or sparks. To prevent fire or explosion do not install in compartments containing batteries or Flammable materials or in locations that require ignition protected equipment. This includes any space containing gasoline-powered machinery, fuel tanks, or joints, fittings, or other connection between components of the fuel system. 3 SYSTEM DESCRIPTION Digital 2000 HR-V in-built 28 AH (x2) 1 2 Front panel 1. LED Display 2. Power Switch 3 5 4 ON 6 OFF Back panel 3. AC Input 4. Output Sockets 5. Circuit Breaker 6. Battery Breaker 4 INSTALLATION AND OPERATION 1. Inspection NOTE: Before installation, please inspect the unit. Be sure that nothing inside the package is damaged. Checking Package Contents You should receive the following items inside the package. · UPS Unit with Battery Connect Internal Battery The rating of the DC Breaker must be according to the UPS battery current (50 Amp). Keep the Battery Breaker ON. Note: For the user operation safety, we strongly recommend that you should use tapes to isolate the battery terminals before operating the unit. Table 2: Model Nominal Battery DC Voltage Digital 2000 HR-V 24 VDC Connect to Utility and Charge Plug in the AC input cord to the wall outlet. The unit will automatically charge the connected internal battery even though the unit is off. Note: Circuit Breaker rating of the Branch Circuit supplied from the Mains Input panel sizing must be 20A/250VAC in accordance with National Electrical Codes and Standards as per schematic. (Based on N.E.C NFPA 70 -2014; Reference: Article 240) Mains Power Panel Input power N cord from UPS 20A breaker L UPS Input power cable Load Connect to Device Simply plug devices to battery supplied sockets. During power failure, it will provide continuous power to connected devices. 5 SPECIFICATIONS MODEL Capacity VA/W INPUT Voltage Voltage range Frequency range OUTPUT AC Voltage regulation (Battery mode) Frequency Range (Battery mode) Transfer time Waveform (Battery mode) Outlets BATTERY Battery capacity (In-built) Battery voltage Floating charging voltage Recharge time (to 90%) Maximum charge current DISPLAY Display PROTECTION Protection ALARM Battery mode Low battery Overload Fault PHYSICAL Dimensions (WxDxH) (mm) Net weight (Kgs) ENVIRONMENT Noise level at 1 m (dBA) Operating temperature Protection index Relative humidity (%) Storage temperature STANDARDS Safety Standards DIGITAL 2000 HRV 2000 VA/1200 W 230 VAC 140 300 VAC 50 Hz 230 V +/- 10% 50 Hz +/- 1 Hz Typical 4 8 ms Simulated sinewave 4 x India type 6 Amps 28AH / 26AH 24 VDC 27.4 VDC +/- 1.0 VDC 4 hours 5A LED display Discharge, Overcharge and Overload protection Sounding every 10 seconds Sounding every second Sounding every 0.5 seconds Continuously sounding 200 X 410 X 467 36.5 Less than 40 dBA 0 ºC to +40 ºC IP 20 0% to 95% (non-condensing) -10 ºC to +50 ºC IS 16242 (Part1): 2014 / IEC 62040-1:2008 *Product specifications are subject to change without further notice 6 TROUBLE SHOOTING Use the table below to solve minor problems. Problem Possible cause Utility power is normal but the unit is in battery mode. AC input power cord is not connected well. Input breaker is activated. When power fails, the backup time is shortened. The unit is overloaded. Battery voltage is too low. Battery capacity is not full even after charging the unit for at least 8 hours. The unit is not turned on. Nothing displays on the front panel when the utility power is normal. Battery is not connected well. Battery defect. Battery voltage is too low. Remedy Check AC input power connection. Reset the input breaker. Remove some non-critical loads. Charge the unit at least 8 hours. Check the date code of the battery. If the batteries are too old, replace the batteries. Press power switch to turn on the unit. Check the Internal battery cable and terminal. Make sure all the battery connections to the unit are all correct. Replace the batteries. Charge the unit at least 8 hours. IMPORTANT SAFETY WARNING As dangerous voltages are present within the UPS, only NUMERIC technicians are permitted to open the UNIT to replace the failed / dead Batteries. Failure to observe this could result in electric shock risk and invalidation of any implied warranty. 7 Head Office 10th Floor, Prestige Center Court, Office Block, Vijaya Forum Mall, 183, N.S.K Salai, Vadapalani, Chennai - 600 026. Phone: +91 44 4656 5555 Regional Offices New Delhi B-225, Okhla Industrial Area, 4th Floor, Phase-1, New Delhi - 110 020. Phone: +91 11 2699 0028 Kolkata Bhakta Tower, Plot No. KB22, 2nd & 3rd Floor, Salt Lake City, Sector - III, Kolkata - 700 098. Phone : +91 33 4021 3535 / 3536 Mumbai C/203, Corporate Avenue, Atul Projects, Near Mirador Hotel, Chakala, Andheri Ghatkopar Link Road, Andheri (East), Mumbai - 400 099. Phone : +91 22 3385 6201 Chennai 10th Floor, Prestige Center Court, Office Block, Vijaya Forum Mall, 183, N.S.K Salai, Vadapalani, Chennai - 600 026. Phone : +91 44 3024 7236 / 200 Branch Offices Chandigarh SCO 4, First Floor, Sector 16, Panchkula, Chandigarh - 134 109. Phone : +91 93160 06215 Dehradun Unit-1 and 2, Chakrata Road, Vijay Park Dehradun 248001. Uttrakhand Phone : +91 135 661 6111 Jaipur Plot No. J-6, Scheme-12B, Sharma Colony, Bais Godown, Jaipur - 302 019. Phone : +91 141 221 9082 Lucknow 209/B, 2nd Floor, Cyber Heights, Vibhuti Khand, Gomti Nagar, Lucknow - 226 018. Phone : +91 93352 01364 Bhubaneswar N-2/72 Ground Floor, IRC Village, Nayapally, Bhubaneswar - 751 015. Phone: +91 674 255 0760 Guwahati House No 02, Rajgarh Girls High School Road (Behind Rajgarh Girls High School), Guwahati - 781 007. Phone : +91 361 245 0322/96000 87171 Patna 405, Fraser Road, Hemplaza, 4th Floor, Patna - 800 001. Phone : +91 612 220 0657 Ranchi 202 & 203, 2nd Floor, Sunrise Forum, Bardwan Compound, Lalpur, 2nd Floor, Ranchi - 834 001. Phone : + 91 98300 62078 Ahmedabad A-101/102, Mondeal Heights, Beside Hotel Novotel, Near Iscon Circle, S G Highway, Ahmedabad - 380 015. Phone : +91 79 6134 0555 Bhopal Plot No. 2, 221, 2nd Floor, Akansha Complex, Zone-1, M.P.Nagar, Bhopal 462 011. Phone : +91 755 276 4202 Nagpur Plot.No.174, H.No.4181/C/174, 1st Floor, Loksewa Housing Society, Near Dr. Umathe & Mokhare College, Bhamti Road, Lokseva Nagar, Nagpur - 440 022. Phone : +91 712 228 6991 / 228 9668 Pune Pinacle 664 park avenue, 8th floor, Plot no 102+103, CTS No. 66/4, Final, 4, Law College Rd, Erandwane, Pune, Maharashtra - 411 004. Phone : +91 98225 36680 Bengaluru No-58, First Floor, Firoze White Manor, Bowring Hospital Road, Shivajinagar, Bangalore -560 001. Phone : +91 80 6822 0000 Coimbatore No. B-15, Thirumalai Towers, No. 723, 1st Floor, Avinashi Road, Coimbatore - 641 018. Phone : +91 422 420 4018 Hyderabad Prestige Phoenix Building, 1st Floor, Survey no. 199, No. 6-3-1219/J/101 & 102, Uma Nagar, Opposite to Begumpet Metro Station Begumpet 500016 Phone: +91 40 4567 1717/2341 4398/2341 4367 Kochi Door No. 50/1107A9, JB Manjooran Estate, 3rd Floor, Bypass Junction, Edappally, Kochi 682 024. Phone : +91 484 6604 710 Madurai 12/2, DSP Nagar, Dinamalar Avenue, Madurai - 625 016. Phone : +91 452 260 4555 NP/DSG/UM/10004/VER01 Sales - enquiry.numeric@numericups.com Service - support.numeric@numericups.com Contact us.: 0484-3103266 / 4723266 www.numericups.com