Instruction Manual for MITSUBISHI ELECTRIC models including: PAC-SG73RJ-E Joint Pipe, PAC-SG73RJ-E, Joint Pipe, Pipe

Mitsubishi Electric PAC-SG73RJ-E Installation Manual

Mitsubishi Electric, PAC-SG73RJ-E, Installation Manual

Mitsubishi, Electric;, PAC-SG73RJ-E;, Installation, Manual

MITSUBISHI ELECTRIC CORP.

Руководство по установке Mitsubishi Electric PAC-SG73RJ-E

Mitsubishi Electric PAC-SG73RJ-E переходник 9,52 на 12,7. От официального дилера. Бесплатная доставка по Украине. | Mitsubishi

PDF preview unavailable. Download the PDF instead.

Mitsubishi Electric PAC-SG73RJ-E INSTALLATION MANUAL Eng-1
Joint Pipe Unit 9.52 Pipe 12.7

PAC-SG73RJ-E

Photo

Dimensions

Unit: mm (inch) 66.5

Descriptions
A part to connect refrigerant pipes of the different diameter. (Unit 9.52  12.7)
Applicable Models
PUHZ-ZRP60,71VHA2 PUHZ-ZRP100,125,140VKA3 PUHZ-ZRP100,125,140YKA3 PUHZ-ZRP200YKA3
[R410A type]
Specifications
Pipe diameter 9.52 Pipe material C 1220T - OL

12.7 (1/2")

9.52 (3/8")

90° ± 0.5° øA
OPTIONAL PARTS

How to Use / How to Install

Make sure that you have all the following parts, in addition to this manual in this box:

Joint Pipe

Installation procedure

PAC-SG72RJ-E (unit side:ø6.35 diameter, onsite pipe side:ø9.52 diameter)

(carefully read the following before installing.)

PAC-SG73RJ-E (unit side:ø9.52 diameter, onsite pipe side:ø12.70 diameter) PAC-SG74RJ-E (unit side:ø12.70 diameter, onsite pipe side:ø15.88 diameter) PAC-SG75RJ-E (unit side:ø15.88 diameter, onsite pipe side:ø19.05 diameter)

This optional part is used to connect indoor/outdoor unit to onsite pipes of different diameters.
When installing this optional part, be sure to read

Unit side

Onsite piping side

"Refrigerant pipe connection" in the installation manual attached to outdoor unit.

1) Apply flare processing to onsite pipes to adapt to R410A, according to the table on the right.Use optional accessory flare nut at this time. Check the installation manual attached to the outdoor unit for advisability on whether or not onsite (existing) pipes can be used. When pipe of 19.05 diameter is used, be sure to turn ON the SW8-1 on outdoor unit control board.

B
dies Copper pipe

Pipe diameter (mm)
ø 6.35(1/4") ø 9.52(3/8") ø12.70(1/2") ø15.88(5/8") ø19.05(3/4")

B size (mm)

R410A flare tool R22/R407C flare tool Clutch type

0 - 0.5

1.0 - 1.5

0 - 0.5

1.0 - 1.5

0 - 0.5

1.0 - 1.5

0 - 0.5

1.0 - 1.5

0 - 0.5

1.0 - 1.5

When flare processing for refrigerant R410A is applied using current tool, refer to

Outer diameter of copper pipe (mm)

Processing size of flare section (mm)

Flare shape

the table above. B size can

ø 6.35

8.7 - 9.1

45° ± 2°

be secured using copper

ø 9.52

12.8 - 13.2

pipe gauge for margin

ø12.70

16.2 - 16.6

adjustment.

ø15.88

19.3 - 19.7

R0.4~R0.8

ø19.05

23.6 - 24.0

2) Remove caps (both ends) for protection against 3) Securely tighten flare nut using torque

mixing of foreign materials from optional part, wrench according to the table on the right.

and thinly apply refrigerat or oil (locally procured) on flare surface.

Proper tightening torque using torque wrench Outer diameter of Tightening torque N·m

Refrigerator oil application point
Apply refrigerator oil to entire circumference of flare sheet surface.

copper pipe (mm) ø 6.35

(kgf·cm) 14 - 18(140 - 180)

ø 9.52

34 - 42(340 - 420)

ø12.70

49 - 61(490 - 610)

Do not apply to thread section. (If applied to threads, flare nut can easily be loosened.)

ø15.88 ø19.05

68 - 82(680 - 820) 100 - 120(1000 - 1200)

4) After refrigerant pipe is connected, be sure to perform gas leakage inspection for onsite connection pipes (including this optional part) and indoor/outdoor unit.
5) Heat insulation is necessary for this optional part: Wrap heat insulator (locally procured) around the onsite pipes and also the optional part (for dewdrop dripping prevention).
6) Perform test run according to the installation manual of the unit, making sure to also perform operation check.

E-229


ABBYY FineReader 14