Instruction Manual for luminii models including: Plexineon Fixture Catenary Mount Static Color, Fixture Catenary Mount Static Color, Catenary Mount Static Color, Mount Static Color, Static Color

Plexineon Catenary Installation Instructions Static Color

Plexineon Rings Catenary Static Color - Luminii

Plexineon Catenary Static Color - Luminii


File Info : application/pdf, 5 Pages, 1.06MB

PDF preview unavailable. Download the PDF instead.

Plexineon Catenary Installation Instructions Static Color
Installation Instructions - Plexineon Catenary Static Color

Models: Plexineon Fixture Catenary Mount Static Color and Plexineon Rings Catenary Mount Static Color

Please read all instructions prior to installation and keep for future reference!

1. PRODUCT TO BE INSTALLED BY A QUALIFIED ELECTRICIAN. 2. USE ONLY WITH CLASS 2 POWER UNIT 3. 24 VOLTS DC 4. SUITABLE FOR WET LOCATIONS

5. CATENARY MOUNT ONLY

REV0.1 10252022
1 / 5

7777 Merrimac Ave Niles, IL 60714 T 224.333.6033 F 224.757.7557 info@luminii.com www.luminii.com

Plexineon Straight Run Fixture Catenary Mount

Plexineon Ring Catenary Mount
*LUMINII RESERVES THE RIGHTS TO CHANGE SPECIFICATION & INSTRUCTION WITHOUT NOTICE

Installation Instructions - Plexineon Catenary Static Color

Models: Plexineon Fixture Catenary Mount Static Color and Plexineon Rings Catenary Mount Static Color

Please read all instructions prior to installation and keep for future reference!

1. PRODUCT TO BE INSTALLED BY A QUALIFIED ELECTRICIAN. 2. USE ONLY WITH CLASS 2 POWER UNIT 3. 24 VOLTS DC 4. SUITABLE FOR WET LOCATIONS

5. CATENARY MOUNT ONLY

REV0.1 10252022
2 / 5

7777 Merrimac Ave Niles, IL 60714 T 224.333.6033 F 224.757.7557 info@luminii.com www.luminii.com

1

NOTE: Prior to installation all 24VDC wires must be present within 72" of the installation. Refer to the power supply installation instruction for additional information.

NOTE: More than one person is recommended for this installation.

1.1 mounting frame joiner screw

NOTE: This step is only for multi-piece frames. If you have single piece frame, skip to step 2.1. mounting clip
mounting frame

1.1 For multi-piece frames, connect the frame members together with mounting frame joiner. Use locknuts to secure connection.

2
2.1

plexineon fixture

mounting frame

mounting clip

2.1 Install plexineon fixture to mounting clips on mounting frame(s).

*LUMINII RESERVES THE RIGHTS TO CHANGE SPECIFICATION & INSTRUCTION WITHOUT NOTICE

Installation Instructions - Plexineon Catenary Static Color

Models: Plexineon Fixture Catenary Mount Static Color and Plexineon Rings Catenary Mount Static Color

Please read all instructions prior to installation and keep for future reference!

1. PRODUCT TO BE INSTALLED BY A QUALIFIED ELECTRICIAN. 2. USE ONLY WITH CLASS 2 POWER UNIT 3. 24 VOLTS DC 4. SUITABLE FOR WET LOCATIONS

5. CATENARY MOUNT ONLY

Install Fixtures into Mounting Clips

A.1

mounting clip

A.2

REV0.1 10252022
3 / 5

7777 Merrimac Ave Niles, IL 60714 T 224.333.6033 F 224.757.7557 info@luminii.com www.luminii.com

mounting clip installation tool
on grip A.1 Make an U shape with mounting clip installation tool, insert two edges into mounting clip. Place plexineon fixture insde the shape. Then push the fixture into clip. A.2 Remove the tool. Make sure mounting clip is clipped right on the grip.

3
3.1
turnbuckle u-bracket

3.2 mounting frame
plexineon fixture

turnbuckle set screw
u-bracket

mounting clip

3.3

bolt

set screw

3.1 Unscrew and remove uchain from turnbuckle. 3.2 Cauculate points for turnbuckles on mounting frame. Set uchain to measured place. 3.3 Screw bolt back into uchain to lock the turnbuckle with mounting frame, securing the position by set screw.

*LUMINII RESERVES THE RIGHTS TO CHANGE SPECIFICATION & INSTRUCTION WITHOUT NOTICE

Installation Instructions - Plexineon Catenary Static Color

Models: Plexineon Fixture Catenary Mount Static Color and Plexineon Rings Catenary Mount Static Color

Please read all instructions prior to installation and keep for future reference!

1. PRODUCT TO BE INSTALLED BY A QUALIFIED ELECTRICIAN. 2. USE ONLY WITH CLASS 2 POWER UNIT 3. 24 VOLTS DC 4. SUITABLE FOR WET LOCATIONS

5. CATENARY MOUNT ONLY

4

locknut

5

saddle

4.1

REV0.1 10252022
4 / 5

7777 Merrimac Ave Niles, IL 60714 T 224.333.6033 F 224.757.7557 info@luminii.com www.luminii.com

catenary cable

turnbuckle

u-bolt

NOTE: Catenary cables are provided by others. Max Ø1/4".
4.1 Loosen locknuts to remove the U-bolt. Place the catenary cable between the saddle and u-bolt. Use locknuts to clamp the catenary cable between the saddle and u-bolt. Do this for all rope clips.

catenary cable

5.1 turnbuckle

mounting frame

plexineon fixture

5.1 After installing plexineon with catenary cable, adjust the length by rotating the middle part of turnbuckle.
NOTE: Turnbuckle is adjustable up to 2.5" vertically.

*LUMINII RESERVES THE RIGHTS TO CHANGE SPECIFICATION & INSTRUCTION WITHOUT NOTICE

Installation Instructions - Plexineon Catenary Static Color

Models: Plexineon Fixture Catenary Mount Static Color and Plexineon Rings Catenary Mount Static Color

Please read all instructions prior to installation and keep for future reference!

1. PRODUCT TO BE INSTALLED BY A QUALIFIED ELECTRICIAN. 2. USE ONLY WITH CLASS 2 POWER UNIT 3. 24 VOLTS DC 4. SUITABLE FOR WET LOCATIONS

5. CATENARY MOUNT ONLY

2

2.1 Connect +24 VDC strip color from

2.1

the Plexineon to the power supply

+24 VDC red wire.

Connect -24 VDC solid color wire

from the Plexineon to power supply

-24 VDC black wire.

REV0.1 10252022
5 / 5

7777 Merrimac Ave Niles, IL 60714 T 224.333.6033 F 224.757.7557 info@luminii.com www.luminii.com

Multiple Fixtures

to Plexineon

Plexineon fixture

Plexineon fixture

Plexineon fixture

*LUMINII RESERVES THE RIGHTS TO CHANGE SPECIFICATION & INSTRUCTION WITHOUT NOTICE



References

Adobe PDF Library 16.0.7 Adobe InDesign 17.4 (Windows)