User Guide for nexsens models including: G2-Rain Alert System, Rain Alert System, Alert System

G2-RAIN QSG

Index of /pdf


File Info : application/pdf, 2 Pages, 215.55KB

PDF preview unavailable. Download the PDF instead.

G2-RAIN QSG
G2-RAIN ALERT SYSTEM
QUICK START GUIDE

IMPORTANT - BEFORE FIELD DEPLOYMENT: Completely configure new G2 systems with a web connection in a nearby work area. Operate the system for several hours and ensure correct sensor readings. Use this test run to become familiar with the features and functions.

Figure 1: G2-RAIN Alert System

1 To get started:
a. Go to WQDataLIVE.com
b. Create a new account or sign into an existing account.
c. Choose or create the project that will contain the data logger by selecting the Projects link from the bottom right footer of the page.
d. Open the project and go to the ADMIN tab located at the top of the project dashboard and click Settings.

2

From there, choose the Project/Site pull down menu and select the site for the new data logger.

a. If a site has not been created, select New Site.

3

Enter the claim code listed below into the space provided under Assigned Devices.

Overview
The G2-RAIN Alert System includes an integrated modem. Power is provided internally through (2) D-Cell lithium batteries. An external power cable (optional accessory) allows connection to an SP-Series solar panel for recharging the internal batteries and direct communication (serial to PC). The integrated tipping bucket supplies accurate rainfall measurements (one tip per 0.01" rain).
Data is accessed and stored on the WQData LIVE web datacenter. An easy-to-use dashboard and built-in sensor library automatically facilitate setup and configuration.

4

Remove the siphoning tipping bucket by using the 3/16" hex wrench to loosen the (3) bolts

connecting the bucket and RTU.

a. Lift the bucket up gently.

b. Remove the rubbing band from the tipping apparatus.

c. Reinstall the bucket and tighten bolts.

What's Included?
(1) G2-RAIN-RTU (1) G2 series battery pack (installed) (1) Rain gauge (1) SMA antenna (1) 3/16" hex wrench (1) Quick start guide

Figure 2: Lift bucket to remove the rubber band on the tipping apparatus.

5 Attach the antenna to the copper SMA connector
found on the bottom of the G2-RTU.

7 External power (Optional with purchase)- Connect
the G2-RTU adapter cable to an SP-Series solar panel or an AC power adapter.
a. Listen for the single audible beep to confirm power connection.
b. After a few seconds:
· Two beeps = sufficient cellular signal
· Three beeps = insufficient cellular signal

Figure 3: Rotate the antenna clockwise onto the threads of the SMA connector.

6

Internal power- Use the included flathead screwdriver to turn the black power set screw

clockwise on the bottom of the G2-RTU.

a. Listen for the single audible beep to confirm power connection.

b. After a few seconds:

· Two beeps = sufficient cellular signal

· Three beeps = insufficient cellular signal

c. To power down, unscrew the set screw until the o-ring is visible.

Figure 5: Connection of the G2-RTU external power cable and an SP-Series solar panel.
Buzzer Pattern Indicators
Table 1: G2-RAIN Buzzer Pattern Indicators.

Buzzer Event

Beep Type

Status

When power is applied
During telemetry connection
During telemetry connection

One short beep
Two short beeps
Three short beeps

System boot successful Connection successfully established
No signal/connection failed

Figure 4: Turn the black power set screw clockwise to apply battery using internal batteries.

For additional information, please reference the G2-RAIN Resource Library on the NexSens Knowledge Base. nexsens.com/g2rkb

937-426-2703 www.nexsens.com

2091 Exchange Court Fairborn, Ohio 45324



References

Adobe PDF Library 15.0 Adobe InDesign 16.2 (Windows)