Danfoss Optyma AK-RC 204B, 205C, 305W-SD Refrigeration Controller
Data Sheet
The Danfoss Optyma AK-RC range offers a comprehensive selection of refrigeration controllers designed for flexibility in cold room applications. These controllers are engineered to minimize installation time and energy consumption while ensuring excellent food quality.
Key Features
- Easy wiring and high environmental protection simplify installation.
- Fast commissioning with a guided start-up wizard.
- Multi-level platform with extensive functionalities and logic for diverse applications and food safety compliance.
- Advanced defrost logic for improved energy efficiency and performance.
- Integrated thermal-magnetic circuit protection.
- Large, clear, and intuitive display for quick information access.
- Comprehensive store management via integration with the Danfoss ADAP-KOOL system using Modbus.
- Standard Modbus connectivity for third-party integration.
- Optional cloud and remote connectivity via the ProsaLink application, IoT module, and Cloud service.
Product Range Overview
Technical Characteristics | AK-RC 204B | AK-RC 205C | AK-RC 305W-SD |
Danfoss Ref. | 080Z5001 | 080Z5002 | 080Z5003 |
Electrical Supply | 230 V AC | 230 V AC | 100 to 240 V AC |
Dimensions (WxHxD) in mm | 290 x 141 x 84.4 | 290 x 141 x 84.4 | 290 x 141 x 84.4 |
Sealing | IP65 | IP65 | IP65 |
Electrical Protection | 2 SPDT 20 A | Yes (16 A) 1 SPDT 16 A | 1 SPDT 16 A |
Digital Outputs | 2 SPST 16 A | 2 SPDT 20 A | 2 SPDT 20 A |
Analog Inputs | 2 NTC | 2 SPST 16 A | 2 SPST 16 A |
Digital Inputs | 1 | 2 NTC | 2 NTC |
Wizard Menu | Yes | 1 | 1 |
Temperature Control | Yes | Yes | Yes |
Advanced Defrost Function | Yes | Yes | Yes |
Modbus | Yes | Yes | Yes |
Data Logger | Option with PR-SC4 | Option with PR-SC4 | Option with PR-SC4 |
Functions
The Optyma Control regulator manages the entire cold room system, including:
- Compressor
- Crankcase Heater
- Evaporator Fans
- Defrost Heater (up to 2 evaporators)
- Solenoid Valve
- Cold Room Light
- Door Frame and Drainage Heater Elements
- Door Control (activity and alarms)
- Remote Setpoint and Defrost Modification
- Alarms (Temperature, Door Open)
Figure 1: Standalone System depicts a single cold room setup where the Optyma controller manages essential components like the compressor, fan, defrost heater, and solenoid valve.
Figure 2: Distributed System illustrates a multi-room setup where Optyma controllers are networked, typically via Modbus, to manage individual cold rooms within a larger system.
The AK-RC 305W utilizes Adaptive Defrost logic to optimize the operation of drainage and plate heaters. This reduces electrical consumption and fan regulation by leveraging the evaporator's thermal inertia (frost), leading to:
- Reduced compressor activations.
- Lower energy consumption.
- Decreased mechanical stress on components.
- Minimized defrost cycles and duration, reducing thermal stress, increasing setpoint time, lowering energy use, and mitigating gas leakage risk.
Applications
The controllers offer easy and quick mounting with simple wiring. The kit includes 2 x 10K NTC sensors. Configuration is streamlined through a wizard:
- Wire the controller.
- Power up the unit.
- Use the Wizard to select the appropriate application based on Table 2: Applications InI.
- Configure the desired setpoint.
Table 2: Applications InI
InI(1) | Installation Type | Cooling Control | Pump Down | Defrost | Evap. Fans |
0 | Demo Mode: Displays temperature on screen but does not regulate temperature or activate relays. | ||||
1 | Solenoid | No | Electric | Yes | |
2 | Solenoid + compressor | Yes | Electric | Yes | |
3 | Solenoid + compressor | No | Electric | Yes | |
4 | Solenoid | No | Air | Yes | |
5 | Solenoid + compressor | Yes | Air | Yes | |
6 | Solenoid + compressor | No | Air | Yes | |
7 | Solenoid + compressor | Yes | Hot gas | Yes | |
8 | Solenoid + compressor | No | Hot gas | Yes | |
9 (2) | Solenoid + compressor | Yes | Cycle inversion | Yes | |
10(2) | Solenoid + compressor | No | Cycle inversion | Yes | |
11(2) | Solenoid valve | No | Static | No | |
12(2) | Solenoid + compressor | Yes | Static | No | |
13(2) | Solenoid + compressor | No | Static | No |
(1) See Electrical Diagrams. (2) Not available for 305W-SD.
Electrical Diagram Components
- Compressor [Compressor]
- Crankcase Heater [Crankcase Heater]
- Fan [Fan]
- Defrost Heater [Defrost Heater]
- Solenoid Valve [Solenoid Valve]
- Hot Gas Valve (HG) [Hot Gas Valve]
- Condenser Solenoid Valve for Hot Gas (COND) [Condenser Solenoid Valve]
- 4-Way Reversing Valve [4-Way Reversing Valve]
- Auxiliary Relay 1 (AUX. 1) [Auxiliary Relay 1]
- Auxiliary Relay 2 (AUX. 2) [Auxiliary Relay 2]
- High-Low Pressure Controller [High-Low Pressure Controller]
- High Pressure Controller [High Pressure Controller]
- Low Pressure Controller [Low Pressure Controller]
Wiring Diagrams
The following figures detail the wiring configurations for different applications (Inl values) and controller models:
- Figure 3: Inl = 1, 4, 11 (AK-RC 204B): Shows wiring for RS485, NTC, DIG. IN, and main power terminals (SSV, DEF, FAN, COOL, AUX 1, H. CRANK.) with current ratings.
- Figure 4: Inl = 2, 3, 5, 6, 12, 13 (AK-RC 204B): Details wiring for various Inl configurations on the AK-RC 204B.
- Figure 5: Inl = 7, 8 (AK-RC 204B): Wiring diagram for specific applications on the AK-RC 204B.
- Figure 6: Inl = 9, 10 (AK-RC 204B): Wiring diagram for specific applications on the AK-RC 204B.
- Figure 7: Inl = 1, 4, 11 (AK-RC 205C): Wiring for the AK-RC 205C, including AUX 2 terminals.
- Figure 8: Inl = 2, 3, 5, 6, 12, 13 (AK-RC 205C): Wiring for various Inl configurations on the AK-RC 205C.
- Figure 9: Inl = 7, 8 (AK-RC 205C): Wiring diagram for specific applications on the AK-RC 205C.
- Figure 10: Inl = 9, 10 (AK-RC 205C): Wiring diagram for specific applications on the AK-RC 205C.
- Figure 11: Inl = 1, 4 (AK-RC 305W): Wiring for the AK-RC 305W, noting its 100-240V power supply.
- Figure 12: Inl = 2, 3, 5, 6 (AK-RC 305W): Wiring for various Inl configurations on the AK-RC 305W.
- Figure 13: Inl = 7, 8 (AK-RC 305W): Wiring diagram for specific applications on the AK-RC 305W.
- Figure 14: Inl = 2, 5, 7, 8 (AK-RC 305W): Wiring diagram showing different inputs for components like drainage heaters, door frame heaters, and hot gas valves on the AK-RC 305W.
- Figure 15: Danfoss Cloud Service: Illustrates the connection of the SC4 module to the AK-RC via Modbus RS485 for cloud connectivity.
- Figure 16: Diagram of the SC4 module.
- Figure 17: AK-RC 204B Power Connection: Shows the power input for the AK-RC 204B.
- Figure 18: AK-RC 205C Power Connection: Shows the power input for the AK-RC 205C.
- Figure 19: AK-RC 305W Power Connection: Shows the power input for the AK-RC 305W.
- Figure 20: Details the 3-wire Modbus connection between the AK-RC controller and a Prosa regulator.
- Figure 21: Displays example controller screen readouts and specifies Modbus parameters: 'b20' for Modbus Address (set to 1) and 'b21' for Communication Speed (set to 1, 19200 baudrate).
Product Specifications
Technical Data
Characteristics | Mounting Specifications | AK-RC 204B | AK-RC 205C | AK-RC 305W |
Supply | 230 V~±10%, 50 Hz ±5% | 230 V~±10%, 50 Hz ±5% | 100-240 V~50/60 Hz | |
Max. power consumption during operation | 6.3 VA | |||
Max. current intensity | 15 A | |||
SSV/DEFROST Relay - SPDT - 20 A | NO | EN60730-1: 15 (15) A 250 V~ | EN60730-1: 15 (13) A 250 V~ | EN60730-1: 15 (15) A 250 V~ |
NF | EN60730-1: 15 (13) A 250 V~ | |||
VENT Relay - SPST - 16 A | EN60730-1: 12 (9) A 250 V~ | EN60730-1: 12 (9) A 250 V~ | EN60730-1: 12 (9) A 250 V~ | |
REFR Relay - SPST - 16 A | EN60730-1: 12 (9) A 250 V~ | EN60730-1: 12 (9) A 250 V~ | EN60730-1: 12 (9) A 250 V~ | |
AUX 1 Relay - SPDT - 20 A | NO | EN60730-1: 15 (15) A 250 V~ | EN60730-1: 15 (15) A 250 V~ | EN60730-1: 15 (15) A 250 V~ |
NF | EN60730-1: 15 (13) A 250 V~ | EN60730-1: 15 (13) A 250 V~ | ||
AUX 2 Relay - SPDT - 16 A | NO | EN60730-1: 12 (9) A 250 V~ | EN60730-1: 12 (9) A 250 V~ | EN60730-1: 12 (9) A 250 V~ |
NF | EN60730-1: 10 (8) A 250 V~ | EN60730-1: 10 (8) A 250 V~ | EN60730-1: 10 (8) A 250 V~ | |
Number of relay operations | EN60730-1: 100,000 operations | |||
Probe temperature range | -50.0 to 99.9 °C | |||
Resolution, setting, and differential | 0.1 °C | |||
Thermometric accuracy | ±1 °C | |||
NTC probe tolerance at 25 °C | ±0.4 °C | |||
Working ambient temperature | AK-RC 204B: -10 to 50 °C | AK-RC 205C: -10 to 45 °C | AK-RC 305W: -10 to 50 °C | |
Storage ambient temperature | -30 to +60 °C | |||
Degree of protection | IP65 | |||
Degree of pollution | II acc. to EN 60730-1 | |||
Control device classification | Built-in type, automatic operation Type 1 B, for use in clean environments, with logic support (software), Class A, and continuous operation. Degree of contamination 2 acc. to UNE-EN 60730-1. Double insulation between power supply, auxiliary circuit, and relay output. | |||
Pressure test temperature | Accessible parts: 75 °C; Parts positioning active elements: 125 °C | |||
Test current for radio interference suppression | 270 mA | |||
EMC tested voltage and current | 207 V, 17 mA | |||
Mounting type | Fixed indoor | |||
Internal buzzer | Present |
Dimensions
Figure 22: AK-RC 204B Dimensions shows the external dimensions of the AK-RC 204B unit.
Figure 23: AK-RC 205C Dimensions shows the external dimensions of the AK-RC 205C unit.
Figure 24: AK-RC 305W Dimensions shows the external dimensions of the AK-RC 305W unit.
Mounting
Figure 25 illustrates a mounting step.
Figure 26 shows mounting with hardware components.
Figure 27 details the required drill hole sizes (Ø 3 mm / 1/8 in. and Ø 5 mm / 3/16 in.) and screw quantities (x3).
Figure 28 provides a close-up view of a mounting detail.
Figure 29 displays mounting dimensions in both inches and millimeters, indicating spacing for wall mounting.
Ordering Information
Table 4: Product References
Description | Part Number |
AK-RC 204B | 080Z5001 |
AK-RC 205C | 080Z5002 |
AK-RC 305W | 080Z5003 |
Table 5: Accessory References
Description | Includes | Qty. | Part Number |
10K NTC Sensor 3.5 m | 10K NTC Sensor 1 x 1.5 m | 1 | 084N3210 |
10K NTC Sensor 8.5 m | 10K NTC Sensor 1 x 3.0 m | 50 | 084N3208 |
10K NTC Sensor 1.5 m | High-accuracy NTC Sensor 2 x 1.5 m | 150 | 084N3200 |
High-accuracy 10K NTC Sensor 1.5 m(1) | 1 | 080Z3216 |
(1) Only for AK-RC 305W-SD.
Certificates, Declarations, and Approvals
This section lists certificates, declarations, and approvals for the product type. Individual part numbers may incorporate some of these, and local approvals might not be listed. For the latest status, visit danfoss.com or contact a local Danfoss representative.
Table 6: Certificates, Declarations, and Approvals
File Name | Document Type | Subject of Document | Approval Authority |
AK-RC 204B | EMC/LVD/RoHS | CE | EU |
AK-RC 205C | EMC/LVD/RoHS | CE | EU |
AK-RC 305W | EMC/LVD/RoHS | CE | EU |
Online Assistance
Danfoss provides extensive online assistance, including digital product information, software, mobile applications, and expert advice. Explore the options below:
- The Danfoss Product Store: Your one-stop shop for product information, part numbers, technical documentation, certifications, and accessories. Visit store.danfoss.com.
- Find Technical Documentation: Access official technical data sheets, certificates, declarations, manuals, guides, 3D models, case studies, and brochures. Search at www.danfoss.com/en/service-and-support/documentation.
- Danfoss Learning: A free online learning platform with training and documents designed for engineers, installers, maintenance technicians, and wholesalers to enhance understanding of products, applications, industry trends, and best practices. Create an account at www.danfoss.com/en/service-and-support/learning.
- Get Local Information and Assistance: Danfoss local websites are primary sources for company and product information, product availability, regional news, and expert contact. Find your local Danfoss website at www.danfoss.com/en/choose-region.