Innovair Q4 Multi Heat Pump Systems

Innovative Ideas in Air Conditioning

Overview

The Innovair Q4 Multi heat pump systems offer advanced, flexible climate control solutions for various residential and commercial applications. These systems are designed for efficiency, comfort, and ease of use, supporting multiple indoor units connected to a single outdoor unit.

The systems are available with different indoor unit types, including High Wall, Fan Coil, and Ceiling Cassette, allowing for tailored comfort in each zone. The outdoor units are designed for robust performance, featuring R454B environmentally friendly refrigerant and Energy Star certification for many models.

Key Features

Indoor Unit Types

High Wall Units

4-WAY AIRFLOW: Allows for air movement in horizontal or vertical positions for complete area coverage.

SLEEP MODE: Limits maximum frequency current while maintaining optimal room temperature for comfortable, energy-saving sleep.

Model #Cooling Capacity (Btu/h)Heating Capacity (Btu/h)Power (V/Hz/Ph)Rated Current (A)Air Flow (CFM)Noise Level (Sound Pressure) (dB(A))Net Dimension (WxHxD) (inch)Net Weight (lbs)
QHW07H2UZRA70007000208-230V~,60Hz,1P0.1834139/32/2932 7/8 x 11 x 8 11/1618.7
QHW09H2UZRA90009000208-230V~,60Hz,1P0.1834139/32/2932 7/8 x 11 x 8 11/1618.7
QHW12H2UZRA1200012000208-230V~,60Hz,1P0.1836539/32/2932 7/8 x 11 x 8 11/1618.7
QHW18H2UZRA1800018000208-230V~,60Hz,1P0.3264745/41/3743 5/16 x 12 13/16 x 9 5/830.8
QHW24H2UZRA2400024000208-230V~,60Hz,1P0.3270647/42/3643 5/16 x 12 13/16 x 9 5/830.8

Ceiling Cassette Units

360° ROUND FLOW: Offers optimum efficiency and comfort with a full-flat panel and micro-channel design allowing smooth air supply.

COMPACT DESIGN: Slim design with body thickness of 8.5 inches (215mm) and installation thickness of 9.6 inches (245mm), reducing ceiling height requirements.

Model #Cooling Capacity (Btu/h)Heating Capacity (Btu/h)Power (V/Hz/Ph)Rated Current (A)Air Flow (CFM)Noise Level (Sound Pressure) (dB(A))Net Dimension (WxHxD) (inch)Net Weight (lbs)
QCS09H2BHRA90009000208/230 50/60 10.63341/294/2355222-1/2 x 8-1/2 x 22-1/234.2
QCS12H2BHRA1200012000208/230 50/60 10.63341/294/2355222-1/2 x 8-1/2 x 22-1/234.2
QCS18H2BHRA1800018000208/230 50/60 11.13643/554/4655733-1/4 x 9-1/4 x 33-1/450.7
QCS24H2BHRA2400024000208/230 50/60 11.13643/554/4655433-1/4 x 9-1/4 x 33-1/450.7

Ducted Units

SLIM DESIGN: The slim duct unit with a thickness of only 7.5in (190mm) makes it applicable for narrow ceiling spaces.

HIGH STATIC DUCT: External static pressure up to a maximum of 0.022 Psig (150Pa) makes the unit applicable for a wide range of building types.

NOTE: Gravity drain; QDL/QDH ducted units DO NOT include a pump.

Model NameCooling Capacity (Btu/h)Heating Capacity (Btu/h)Power (V/Hz/Ph)Rated Current (A)Air Flow (CFM)Noise Level (Sound Pressure) (dB(A))Net Dimension (WxHxD) (inch)Net Weight (lbs)
QDL09H2BHWA90009000208/230 50/60 10.5324/294/2355736 x 7-1/2 x 17-5/844.1
QDL12H2BHWA1200012000208/230 50/60 10.5324/294/2355736 x 7-1/2 x 17-5/844.1
QDH18H2BHWA1800018000208/230 50/60 11.13530/471/4125431-1/2 x 9-5/8 x 27-1/258.4
QDH24H2BHWA2400024000208/230 50/60 11.20735/647/5595447-1/4 x 9-5/8 x 27-1/273.9

Outdoor Unit Specifications

The Q4 Multi systems support various outdoor unit configurations, allowing connection of up to 2, 3, 4, or 5 indoor units.

SpecificationUp to 2 indoor unitsUp to 3 indoor unitsUp to 4 indoor unitsUp to 5 indoor units
Model #QOM18H2BM2AQOM27H2BM3AQOM36H2BM4AQOM42H2BM5A
AHRI# (Non-Ducted)215747775215747778215747785215747782
E-STAR V6.1YesYesYesYes
GasR454BR454BR454BR454B
Voltage, Frequency, Phase208/230-60-1208/230-60-1208/230-60-1208/230-60-1
Voltage Range187~253V187~253V187~253V187~253V
Rated Capacity at 95°F (Btu/h)18000270003600042000
Cooling Capacity Range (MIN-MAX) (Btu/h)18000270003600042000
Capacity at 115°F (Btu/h)18000270003600042000
Power Input Cooling (W)1350210028023500
Current Range Cooling (A)6.3 (2.4~12.1)9.3 (3.6~13.6)12.8 (5.3~24)15.5 (5.3~28.0)
EER2 at 95°F (Btu/h/W)13.3012.8512.8512
SEER2 (Btu/h/W)22.0023.002222
Working Temperature Range (°F)5~125°F5~125°F5~125°F5~125°F
Rated Capacity at 47°F (Btu/h)18000270003600048000
Heating Capacity Range (MIN-MAX) (Btu/h)14500~3000020100~440009000~540009000~58000
Power Input Heating (W)1380220027003910
Current Range Heating (A)6.4 (2.1~15.7)10 (5.9~20)12.5 (9.0~23.8)18.0 (9.7~24.5)
COP2 at 47°F (W/W)3.823.603.913.60
COP @ 5°F (W/W)1.991.821.921.92
HSPF2(IV) (Btu/h/W)10.0010.00109.5
HSPF2(V) (Btu/h/W)7.957.77.787.4
Rated Capacity Heating at 17°F (-8.3) (Btu/h)11500176002260028200
Maximum Heating Capacity @17°F (-8.3) (Btu/h)18000270003600036000
Maximum Heating Capacity @5°F(-15) (Btu/h)18000270003600036000
Maximum Heating Capacity @-5°F (-20.5) (Btu/h)13500200002700028000
Maximum Heating Capacity @-13°F (-25) (Btu/h)13356191772617527216
Working Temperature Range (°F)-13~75°F-13~75°F-13~75°F-13~75°F
Max. td Fuse/Breaker (A)20254545
Power Source Cable Size (No.x AWG)3×14AWG3×12AWG3×10AWG3×10AWG
Communication Cable Size (No.x AWG)4×16AWG4×16AWG4×16AWG4×16AWG
Power Consumption in Stand-by mode (W)12202020
Airflow Outdoor Unit (CFM)1850335733573357
Noise Level (dB(A) Max)55626464
Compressor TypeROTARYROTARYROTARYROTARY
Net Dimension (WxHxD) (inch)34 x 26-1/2 x 12-1/438-1/2 x 33 x 14-1/438-1/2 x 33 x 14-1/438-1/2 x 33 x 14-1/4
Net Weight (lbs)101.4160.6169.8172
Diameter(Liquid) (inch)1/41/41/41/4
Diameter(Gas) (inch)3/83/83/83/8
Piping Max Length(Each) (ft)82828282
Piping Max Length(Total) (ft)164230230262
Piping Max Height (ft)49494949
Pre-Charged refrigerant (oz)51.1576.2105.8105.8
Pre-Charged refrigerant (oz/ft)0.1610.1610.1610.161

*Specifications are subject to changes without notice. Model numbers, pictures, and specifications of all products are subject to change without further notice.

System Combinations

The Q4 Multi systems allow flexible combinations of indoor units with compatible outdoor units. Below are examples of allowed configurations.

QOM18H2BM2A (2 Pipe Outdoor Unit)

Two Units

Combinations
07+07
07+09
07+12
09+09
09+12
12+12

QOM27H2BM3A (3 Pipe Outdoor Unit)

Two Units

Combinations
07+07
07+09
07+12
07+18
09+09
09+12
09+18
09+24
12+12
12+18
18+18

Three Units

Combinations
07+07+07
07+07+09
07+07+12
07+07+18
07+09+09
07+09+12
07+09+18
07+12+12
07+12+18
09+09+09
09+09+12
09+09+18
09+12+12
09+12+18
12+12+12

QOM36H2BM4A (4 Pipe Outdoor Unit)

Two Units

Combinations
07+07
07+09
07+12
07+18
07+24
09+09
09+12
09+18
09+24
12+12
12+18
12+24
18+18
18+24
24+24

Three Units

Combinations
07+07+07
07+07+09
07+07+12
07+07+18
07+07+24
07+09+09
07+09+12
07+09+18
07+09+24
07+12+12
07+12+18
07+12+24
07+18+18
07+18+24
09+09+09
09+09+12
09+09+18
09+09+24
09+12+12
09+12+18
09+12+24
09+18+18
09+18+24
12+12+12
12+12+18
12+12+24
12+18+18
12+18+24

Four Units

Combinations
07+07+07+07
07+07+07+09
07+07+07+12
07+07+07+18
07+07+07+24
07+07+09+09
07+07+09+12
07+07+09+18
07+07+09+24
07+07+12+12
07+07+12+18
07+07+12+24
07+07+18+18
07+07+18+24
07+09+09+09
07+09+09+12
07+09+09+18
07+09+09+24
07+09+12+12
07+09+12+18
07+09+12+24
07+09+18+18
07+09+18+24
07+12+12+12
07+12+12+18
07+12+12+24
07+12+18+18
07+12+18+24
07+18+18+18
07+18+18+24
09+09+09+09
09+09+09+12
09+09+09+18
09+09+09+24
09+09+12+12
09+09+12+18
09+09+12+24
09+09+18+18
09+09+18+24
09+12+12+12
09+12+12+18
09+12+12+24
09+12+18+18
09+12+18+24
09+18+18+18
09+18+18+24
12+12+12+12
12+12+12+18
12+12+12+24
12+12+18+18
12+12+18+24
12+18+18+18
12+18+18+24
18+18+18+18
18+18+18+24

QOM42H2BM5A (5 Pipe Outdoor Unit)

Two Units

Combinations
07+07
07+09
07+12
09+09
09+12
12+12

Three Units

Combinations
07+07+07
07+07+09
07+07+12
07+09+09
07+09+12
07+12+12
09+09+09
09+09+12
09+12+12
12+12+12

Four Units

Combinations
07+07+07+07
07+07+07+09
07+07+07+12
07+07+09+09
07+07+09+12
07+07+12+12
07+09+09+09
07+09+09+12
07+09+12+12
07+12+12+12
09+09+09+09
09+09+09+12
09+09+12+12
09+12+12+12
12+12+12+12

Five Units

Combinations
07+07+07+07+07
07+07+07+07+09
07+07+07+07+12
07+07+07+09+09
07+07+07+09+12
07+07+07+12+12
07+07+09+09+09
07+07+09+09+12
07+07+09+12+12
07+07+12+12+12
07+09+09+09+09
07+09+09+09+12
07+09+09+12+12
07+09+12+12+12
07+12+12+12+12
09+09+09+09+09
09+09+09+09+12
09+09+09+12+12
09+09+12+12+12
09+12+12+12+12
12+12+12+12+12

PDF preview unavailable. Download the PDF instead.

Innovair-Q4-Multi-Heat-Pump-Brochure-0825D Adobe PDF Library 17.0 Adobe InDesign 20.5 (Macintosh)

Related Documents

Preview Innovair Q4+ Heat Pump Series: Specifications and Features
Explore the Innovair Q4+ Heat Pump series, featuring high efficiency, cold climate operation, and various indoor unit options including High Wall, Ducted, and Ceiling Cassette. Detailed specifications for cooling and heating performance, dimensions, and more.
Preview Innovair Q4+ Heat Pump & Air Conditioner Systems | Efficient Climate Control
Explore the Innovair Q4+ series of heat pumps and air conditioners, featuring advanced DC inverter technology, R454B refrigerant, and exceptional cold climate performance. Discover models for High Wall, Ducted, and Ceiling Cassette installations.
Preview Innovair Q4 Ductless Single Zone Heat Pump Approval Drawings
Detailed approval drawings and specifications for the Innovair Q4 Ductless Single Zone Heat Pump, covering performance, features, technical data, and dimensions for various models.
Preview Innovair M4 Multi Heat Pump System - Product Specifications and Features
Explore the Innovair M4 Multi Heat Pump System, featuring advanced R454B refrigerant, EnergyStar ratings, and flexible zone configurations. This document details specifications for various indoor units including Highwall, Cassette, Floor/Ceiling, and Console types, along with multi-indoor unit combination rules.
Preview Innovair M4 Floor/Ceiling Heat Pump System - Technical Specifications and Features
Detailed specifications and features for the Innovair M4 Floor/Ceiling Heat Pump system, including cooling and heating capacities, energy efficiency ratings (SEER2, EER2, HSPF2), refrigerant type (R454B), dimensions, and operating temperatures.
Preview Innovair Slim 4+ Central Heat Pump System: Approval Drawings and Specifications
Comprehensive approval drawings and technical specifications for the Innovair Slim 4+ Central Heat Pump System. Details include performance metrics like SEER2 and HSPF2, features, model variations, dimensions, electrical heating element compatibility, and available options for residential and commercial applications.
Preview Innovair M4 Multi Heat Pump System Specifications and Features
Detailed specifications and features for the Innovair M4 Multi Heat Pump System, including various indoor unit combinations, technical data, and product highlights for efficient air conditioning and heating.
Preview Innovair Condensing Units Installer's Guide: GOV36H2BA, GOV60H2BA
This comprehensive installer's guide from Innovair details the installation, operation, and maintenance of their GOV36H2BA and GOV60H2BA split system condensing units. It covers safety protocols, unit specifications, refrigerant handling (R454B), electrical wiring, troubleshooting, and best practices for optimal HVAC system performance.