User Guide for UNI-T models including: UPO1000CS Digital Phosphor Oscilloscope, UPO1000CS, Digital Phosphor Oscilloscope, Phosphor Oscilloscope, Oscilloscope
UPO1000CS-Digital Oscilloscopes-UNI-T Voltage Meter, Multimeter, Oscilloscope | UNI-T-UNI-T Voltage Meter, Multimeter, Oscilloscope | UNI-T
4 / 14 AC Alternating current of device. Please check the region’s voltage range. DC Direct current of device. Please check the region’s voltage range. Grounding Frame and chassis grounding terminal. Grounding Protective grounding terminal. Grounding Measuring grounding terminal. OFF Main power off. ON Main power on. Power
File Info : application/pdf, 14 Pages, 1.01MB
DocumentDocumentUPO1000CS Series Digital Phosphor Oscilloscope Quick Start Guide REV 1 2022.11.7 Copyright Information Uni-Trend Technology (China) Co., Ltd. All rights reserved. Trademark Information UNI-T is the registered trademark of Uni-Trend Technology (China) Co., Ltd. Document Version UPO1000CS-20220901-V1.00 Statement UNI-T products are protected by patent rights in China and foreign countries, including issued and pending patents. UNI-T reserves the rights to any product specification and pricing changes. UNI-T reserves all rights. Licensed software products are properties of Uni-Trend and its subsidiaries or suppliers, which are protected by national copyright laws and international treaty provisions. Information in this manual supersedes all previously published versions. 2 / 14 1. Safety Requirement This section contains information and warnings that must be followed to keep the instrument operating under safety conditions. In addition, user should also follow the common safety procedures. Safety Precautions Warning Please follow the following guidelines to avoid possible electric shock and risk to personal safety. Users must follow the following conventional safety precautions in operation, service and maintenance of this device. UNI-T will not be liable for any personal safety and property loss caused by the user's failure to follow the following safety precautions. This device is designed for professional users and responsible organizations for measurement purposes. Do not use this device in any way not specified by the manufacturer. This device is only for indoor use unless otherwise specified in the product manual. Safety Statement Warning Caution Note "Warning" indicates the presence of a hazard. It reminds users to pay attention to a certain operation process, operation method or similar. Personal injury or death may occur if the rules in the "Warning" statement are not properly executed or observed. Do not proceed to the next step until you fully understand and meet the conditions stated in the "Warning" statement. "Caution" indicates the presence of a hazard. It reminds users to pay attention to a certain operation process, operation method or similar. Product damage or loss of important data may occur if the rules in the "Caution" statement are not properly executed or observed. Do not proceed to the next step until you fully understand and meet the conditions stated in the "Caution" statement. "Note" indicates important information. It reminds users to pay attention to procedures, methods and conditions, etc. The contents of the "Note" should be highlighted if necessary. Safety Sign Danger It indicates possible danger of electric shock, which may cause personal injury or death. Warning It indicates that you should be careful to avoid personal injury or product damage. Caution Note It indicates possible danger, which may cause damage to this device or other equipment if you fail to follow a certain procedure or condition. If the "Caution" sign is present, all conditions must be met before you proceed to operation. It indicates potential problems, which may cause failure of this device if you fail to follow a certain procedure or condition. If the "Note" sign is present, all conditions must be met before this device will function properly. 3 / 14 AC DC Grounding Alternating current of device. Please check the region's voltage range. Direct current of device. Please check the region's voltage range. Frame and chassis grounding terminal. Grounding Protective grounding terminal. Grounding Measuring grounding terminal. OFF Main power off. ON Main power on. Power Supply CAT I CAT II CAT III CAT IV Certification Certification Standby power supply: when the power switch is turned off, this device is not completely disconnected from the AC power supply. Secondary electrical circuit connected to wall sockets through transformers or similar equipment, such as electronic instruments and electronic equipment; electronic equipment with protective measures, and any high-voltage and low-voltage circuits, such as the copier in the office. CATII: Primary electrical circuit of the electrical equipment connected to the indoor socket via the power cord, such as mobile tools, home appliances, etc. Household appliances, portable tools (e.g. electric drill), household sockets, sockets more than 10 meters away from CAT III circuit or sockets more than 20 meters away from CAT IV circuit. Primary circuit of large equipment directly connected to the distribution board and circuit between the distribution board and the socket (three-phase distributor circuit includes a single commercial lighting circuit). Fixed equipment, such as multi-phase motor and multi-phase fuse box; lighting equipment and lines inside large buildings; machine tools and power distribution boards at industrial sites (workshops). Three-phase public power unit and outdoor power supply line equipment. Equipment designed to "initial connection", such as power distribution system of power station, power instrument, front-end overload protection, and any outdoor transmission line CE indicates a registered trademark of EU. UKCA indicates a registered trademark of United Kingdom. Certification ETL indicates a registered trademark of Intertek. Waste EFUP This product complies with the marking requirements of WEEE Directive (2002/96/EC). This additional label indicates that this electrical / electronic product must not be discarded in household waste. This environment-friendly use period (EFUP) mark indicates that dangerous or toxic substances will not leak or cause damage within this indicated time period. The 4 / 14 environment-friendly use period of this product is 40 years, during which it can be used safely. Upon expiration of this period, it should enter the recycling system. Safety Requirements Warning Please connect this device to AC power supply with the power cable provided; The AC input voltage of the line reaches the rated value of this device. See the Preparation before use product manual for specific rated value. The line voltage switch of this device matches the line voltage; The line voltage of the line fuse of this device is correct. Check all terminal rated values Please check all rated values and marking instructions on the product to avoid fire and impact of excessive current. Please consult the product manual for detailed rated values before connection. You can only use the special power cord for the instrument approved by the local and Use the power cord properly state standards. Please check whether the insulation layer of the cord is damaged or the cord is exposed, and test whether the cord is conductive. If the cord is damaged, please replace it before using the instrument. To avoid electric shock, the grounding conductor must be connected to the ground. Instrument Grounding This product is grounded through the grounding conductor of the power supply. Please be sure to ground this product before it is powered on. AC power supply Please use the AC power supply specified for this device. Please use the power cord approved by your country and confirm that the insulation layer is not damaged. This device may be damaged by static electricity, so it should be tested in the anti- Electrostatic prevention static area if possible. Before the power cable is connected to this device, the internal and external conductors should be grounded briefly to release static electricity. The protection grade of this device is 4KV for contact discharge and 8KV for air discharge. Measurement accessories Measurement accessories are of lower class, which are definitely not applicable to main power supply measurement, CAT II, CAT III or CAT IV circuit measurement. Please use the input / output ports provided by this device in a properly manner. Do Use the input / output port of this device properly not load any input signal at the output port of this device. Do not load any signal that does not reach the rated value at the input port of this device. The probe or other connection accessories should be effectively grounded to avoid product damage or abnormal function. Please refer to the product manual for the rated value of the input / output port of this device. Power fuse Please use power fuse of specified specification. If the fuse needs to be replaced, it must be replaced with another one that meets the specified specifications (Class T, 5 / 14 rated current 5A, rated voltage 250V) by the maintenance personnel authorized by UNI-T. There are no components available to operators inside. Do not remove the protective Disassembly and cleaning cover. Maintenance must be carried out by qualified personnel. This device should be used indoors in a clean and dry environment with ambient Service environment temperature from 0 to 40 . Do not use this device in explosive, dusty or humid air. Do not operate in humid environment Do not operate in flammable and explosive environment Do not use this device in a humid environment to avoid the risk of internal short circuit or electric shock. Do not use this device in a flammable and explosive environment to avoid product damage or personal injury. Caution Abnormity Cooling Safe transportation Proper ventilation Keep clean and dry If this device may be faulty, please contact the authorized maintenance personnel of UNI-T for testing. Any maintenance, adjustment or parts replacement must be done by the relevant personnel of UNI-T. Do not block the ventilation holes at the side and back of this device; Do not allow any external objects to enter this device via ventilation holes; Please ensure adequate ventilation, and leave a gap of at least 15 cm on both sides, front and back of this device. Please transport this device safely to prevent it from sliding, which may damage the buttons, knobs or interfaces on the instrument panel. Poor ventilation will cause the device temperature to rise, thus causing damage to this device. Please keep proper ventilation during use, and regularly check the vents and fans. Please take actions to avoid dust or moisture in the air affecting the performance of this device. Please keep the product surface clean and dry. Note Calibration The recommended calibration period is one year. Calibration should only be carried out by qualified personnel. 6 / 14 2. Introduction of UPO1000CS Series Digital Phosphor Oscilloscope UPO1000CS series contains the following 2 models. Model Analog Channels UPO1202CS 2 UPO1102CS 2 Bandwidth 200MHz 100MHz 3. Getting Started Guide This chapter introduces on using the oscilloscope for the first time, the front and rear panels, the user interface, as well as the built-in help system. 3.1 General Inspection It is recommended to inspect the instrument follow the steps below before using the UPO1000CS series for the first time. (1) Check for Damages Caused by Transport If the packaging carton or the foam plastic cushions are severely damaged, please contact the UNI-T distributor of this product immediately. (2) Check Attachment Please check appendix for the list of accessories. If any of the accessories are missing or damaged, please contact UNI-T or local distributors of this product. (3) Machine Inspection If the instrument appears to be damaged, not working properly, or has failed the functionality test, please contact UNI-T or local distributors of this product. If the equipment is damaged due to shipping, please keep the packaging and notify both the transportation department and UNI-T distributors. 7 / 14 3.2 Before Use To perform a quick verification of the instrument's normal operations, please follow the steps below (1) Connect to the Power Supply The power supply voltage range is from 100 VAC to 240 VAC, the frequency range is 45 Hz to 440 Hz. Connect the oscilloscope to the power supply line that came with the oscilloscope or any power supply line that meets the local country standards. Turn on the power button, which on the back of the oscilloscope. The soft power button in the front of the oscilloscope should be on red. (2) Boot Check Press the soft power button and the light should change to green. The oscilloscope will show a boot animation, and then enter the normal interface. (3) Connect Probe Use probe in the attachment and connect it BNC terminal to the channel 1 BNC terminal of the oscilloscope. Connect the probe's main alligator clip to the "Compensating signal terminal" and the ground clip is connected to the "Ground terminal" shown below. The output of the compensating signal should be a 3 Vpp amplitude, default frequency is 1 kHz. Compensating signal terminal Ground terminal Figure 1 Compensating Signal and Ground Terminal (4) Function Check Press the AUTO key, a 3 Vpp 1 kHz square ware should appear. Repeat step 3 for all channels. (5) Probe Compensation When the probe is connected to any input channel for the first time, this step might be required in order to match the probe and the input channel. Probes that are not compensated may lead to measurement errors or mistake. Please follow the following steps: 8 / 14 Set the attenuation coefficient in the probe menu and the switch on the probe to 10x, and connect the probe to CH1. Make sure the probe's connector is properly connected with the oscilloscope. Connect the probe's main clip and ground clip to the oscilloscope's compensating signal and ground terminal respectively. Open CH1 and press the AUTO button. View displayed waveforms Excessive Compensation Correct Compensation Insufficient Compensation Figure 2 Compensating Calibration of Probe If the displayed waveform is look like the above "Insufficient Compensation" or "Excessive Compensation", use a non-metallic screwdriver to adjust the probe's variable capacitance until the display matches the "Correct compensation" waveform. Warning: To avoid electric shock when measuring high voltage using the probe, please ensure that the probe insulation is in good condition and avoid physical contact with any metallic part of the probe. 9 / 14 4. Front Panel 1 2 3 4 5 6 14 13 12 Figure 3 Front Panel 11 10 9 8 7 Table 1 Description of Front Panel NO. Description 1 Screen display area 2 Multipurpose knob 3 Function menu 4 Run/Stop, Automatic setting 5 Trigger control 6 Default, Help menu Compensation signal and 7 Ground terminal NO. Description EXT (External trigger input) 8 terminal 9 Horizontal control area 10 Analog channel input terminal 11 Vertical control area 12 Control menu, copy key 13 USB HOST interface 14 Soft Power on/off 10 / 14 5. Rear Panel 4 1 2 3 Figure 4 Rear Panel Table 2 Description of Rear Panel NO. Description 1 USB Device interface 2 LAN interface NO. Description 3 Pass/Fail output terminal 4 Safety lock 11 / 14 6. User Interface 1 2 3 4 5 6 7 8 15 14 13 12 Figure 5 User Interface 11 10 9 Table 3 User Interface Icon NO. Description 1 Trigger status identification 2 Timing scale 3 Sampling rate/Storage depth 4 Waveform identification 5 Trigger position 6 Horizontal displacement 7 Trigger information 8 Operation menu NO. Description 9 System time 10 LAN identification 11 USB host identification 12 MATH state identification 13 CH2 state identification 14 CH1 state identification Analog channel 15 identification/Waveform 12 / 14 7. Operation Menu Symbols in the menu: Rotate the multipurpose knob on the front panel to select the parameter and adjust the value. There is a pull-down menu. There is a next menu. To input contents, press the numeric keyboard on the front panel or touch the screen to make the keyboard pop up. Circle number presents the total page of menu. Single page has no small circle, and two or more pages will have small circle display. Press F5 to turn pages. 8. Remote Control UPO1000CS series digital phosphor oscilloscope communicates with the computer through USB interface and LAN interface to achieve remote control. Remote control is implemented based on the SCPI (Standard Commands for Programmable Instruments) command set. UPO1000CS series digital phosphor oscilloscope supports three remote control modes: a. User-defined programming. b. Use PC software (instrument manager). c. Web Control. 9. Troubleshooting (1) When press the soft power button, the oscilloscope is blank screen a. Check whether the power is correctly connected, power supply is normal or not. b. Check whether the power switch is really turned on, press the front panel power key and confirm green light and a relay sound is present. c. If there is a relay sound, it indicates that the oscilloscope starts normally. Try the following operations: press the DEFAULT key, then press F1, if device returns to normal, it means backlight brightness is too low. d. After completing the above steps, restart the oscilloscope. e. If you still cannot use this product normally, please contact UNI-T. (2) After signal acquisition, waveform does not appear on display a. Check whether both ends of the BNC cable are connected properly. b. Check whether the output channel of the signal source is open. c. Check whether the oscilloscope access signal channel is open. 13 / 14 d. Check whether the signal in the signal source has a DC offset. e. Remove the incoming signal and check whether the baseline is in screen range (if not, self- calibration is required). f. If you still cannot use this product normally, please contact UNI-T. (3) The measured voltage amplitude value is 10 times larger or smaller than the actual value: Check that the channel probe attenuation coefficient settings are consistent with the used probe attenuation rate. (4) There is a waveform displays but not stable: a. Check the trigger source in the trigger menu and confirm that it matches the input channel of the actual signal. b. Check the trigger type: general signals should use "Edge" trigger. Only when the proper trigger type is used, the waveform can displayed stably. c. Change the trigger coupling to high-frequency or low-frequency to filter out the high-frequency or low-frequency noise that interferes with the trigger. (5) No display after pressing RUN/STOP: a. Check whether the mode at the trigger panel (TRIGGER) is on "Normal" or "Single" and whether the trigger level exceeds the waveform range. b. If it exceedsset the trigger level to the middle or set the mode to AUTO. c. Press AUTO button could automatically finish the above setting. (6) Waveform refresh is very slow: a. Check whether the acquisition method is average and the average times are large. b. Check whether the storage depth is the maximum. c. Check whether the trigger release time is large. d. Check whether the trigger is normal and the current time base is slow. e. All the preceding causes slow refreshing of waveforms. Users can restore the factory settings so that the waveforms can be refreshed normally. 10. Appendix Contact Us If the use of this product has caused any inconvenience, please contact your local UNI-T dealer or sales center. You can send emails to infosh@uni-trend.com.cn to contact us. Our office hours are from 8 a.m. to 5:30 p.m. (Chinese standard time), Monday to Friday. For product support outside mainland China, please contact your local UNI-T distributor or sales center. Service support: Many UNI-T products have the option of extending the warranty and calibration period, please contact your local UNI-T dealer or sales center. To obtain the address list of our service centers, please visit our website at URL: http://www.uni-trend.com 14 / 14