User Guide for KRAMER models including: AFM-20DSP-AEC 20 Port Audio Matrix, AFM-20DSP-AEC, 20 Port Audio Matrix
Купить AFM-20DSP-AEC Матричный аудиопроцессор с DSP и AEC, 20 интерфейсов с фантомным 48 В, Dante, USB | СНК-С | Дистрибьютор ProAV
File Info : application/pdf, 4 Pages, 753.72KB
DocumentDocumentAFM-20DSP-AEC Quick Start Guide Scan for full manual This guide helps you install and use your AFM-20DSP-AEC for the first time. Go to www.kramerav.com/downloads/AFM-20DSP-AEC to download the latest user manual and check if firmware upgrades are available. Step 1: Check what's in the box AFM-20DSP-AEC 20 Port Audio Matrix 1 Power cord 1 Set of rack ears 4 Rubber feet 1 Quick Start guide Step 2: Get to know your AFM-20DSP-AEC # Feature 1 STATUS LED 2 PORTS LEDs (1 to 20) 3 IN OUT DanteTM LEDs (1 to 4) Function Indicates the system's status: · 3 cycles of red/blue/off/green LEDs that flash in sequence for 30 seconds when the system starts up, and the application has not been launched. Indicate the port's status: · Green when an input signal is detected, and the port is defined as line in. · White when defined as line out. · Blue when defined as mic in. Indicate the Dante's signal status: · Green when a signal is detected. · Red when clipping occurs. · Flashes green when the application starts. · Stays green when system is ready for use. · Red when in clipping state. · Yellow when in limiting state. · Off when there is no signal on the input. · Yellow when in limiting state. · Off when no signal is detected. 4 HDMITM LEDs EMBED Turns green when an analog audio signal is associated with the HDMI OUT signal. Otherwise, it stays OFF. DE-EMBED Turns green when the HDMI IN audio signal is detected. Otherwise, it stays OFF. 5 IN OUT USB or S/PDIF LEDs Indicate the USB or S/PDIF's status: · Green when a signal is detected. · Off when no signal is detected. If a signal is detected on one channel, either left only or right only, the status LED is green. 6 CH 1(L)/CH 2(R) AMPLIFIER Indicate the amplifier's signal status: LEDs · Green when a signal is detected. · Off when no signal is detected. On the web page, CH1 and CH2 are referred to as AMP 1 and AMP 2, respectively. AFM-20DSP-AEC Quick Start P/N: 2 9 0 0 - 3 0 1 4 8 6 QS Rev: 1 # Feature Function 7 PORTS 3-pin Terminal Block Interchangeable balanced mono-audio ports. Connect to an audio source or acceptor in 1 Connectors (1 to 20) of 8 selectable I/O configurations: 16x4, 14x6, 12x8, 12x8 AEC ,10x10, 8x12, 6x14, 4x16. Define each port as line in, mic in, mic + 48V in, or line out. 8 USB AFM-20DSP-AEC can process the USB audio as a stereo speaker or operate as an audio line-in or microphone for an audio recorder application or call conferencing. When the AFM-20DSP-AEC is connected to a computer via USB-B: · In the computer's Settings > Manage sound devices > Output devices, the AFM20DSP-AEC USB shows as "Speaker USB AUDIO CODEC". · In a computer recoding application, the audio input settings for AFM-20DSP-AEC show as "Line USB AUDIO CODEC". Important: · The computer's "Output" device (such as speakers) shows in the AFM-20DSP-AEC embedded web pages as a USB Digital "Input". · The computer's "Input" device (such as a microphone) shows in the AFM-20DSPAEC embedded web pages as a USB Digital "Output". 9 HDMITM OUT Connector Connect to an HDMI acceptor to embed an audio signal from the matrix. 10 HDMITM IN Connector Connect to an HDMI source to de-embed the audio signal (the video signal is passed through to the output). 11 S/PDIF OUT RCA Connector Connect to a digital stereo audio acceptor. 12 S/PDIF IN RCA Connector Connect to a digital stereo audio source. 13 SPEAKER OUT Outputs two selected audio signals in two channels. · For Lo-Z: connect stereo output to Lo-Z speakers: L+ and L- to the left speaker; R+R- to the right speaker. · For Hi-Z (70V or 100V): connect Hi-Z and COM to mono Hi-Z speakers. 14 Dante PoE RJ-45 Port Connect to Dante audio through the network. Provides 4 Tx channels and 4 Rx channels. By default, DHCP is enabled. 15 RS-232 3-pin Terminal Block Connect to a PC/serial controller to control the device. Connector 16 ETHERNET RJ-45 Connector Connect to a PC via a LAN to control the device and for firmware upgrades. 17 Micro USB PROG. PORT Connect to your PC to control the device. 18 RESET Recessed Button Press and hold for 5 seconds, to reset the configuration to its default parameters. 19 Mains Power Connector and Plug in for the power cord. Fuse 20 POWER Illuminated Power Switch Turns the device on and off. Step 3: Mount AFM-20DSP-AEC To rack mount the machine, attach both rack ears (remove the screws from each side of the machine and replace screws through the rack ears) or place the machine on a table. · Ensure that the environment (e.g., maximum ambient temperature & air flow) is compatible for the device. · Avoid uneven mechanical loading. · Appropriate consideration of equipment nameplate ratings should be used for avoiding overloading of the circuits. · Reliable earthing of rack-mounted equipment should be maintained. Step 4: Connect inputs and outputs Always turn off the power on each device before it is connected to the AFM-20DSP-AEC device. For optimum range and performance, use the recommended Kramer cables available at www.kramerav.com/product/AFM-20DSP-AEC. The use of third-party cables may cause damage! Step 5: Connect the power Connect the power cord to AFM-20DSP-AEC and plug it into the mains electricity. Safety Instructions (See www.kramerav.com for updated safety information) Caution: · There are no operator serviceable parts inside the unit. Warning: · Use only the power cord that is supplied with the unit. · Disconnect the power and unplug the unit from the wall before installing. · Do not open the unit. High voltages can cause electrical shock! Servicing by qualified personnel only. · To ensure continuous risk protection, replace fuses only according to the rating specified on the product label which located on the bottom of the unit. Step 6: Operate AFM-20DSP-AEC To operate AFM-20DSP-AEC, use: · Embedded web pages via the Ethernet. · RS-232 serial commands transmitted by a touch screen system, PC, or other serial controller. RS-232 Control / Protocol 3000 Baud Rate: 115,200 Parity: None Data Bits: 8 Command Format: ASCII Stop Bits: 1 Example: (adjust the amplified audio from analog audio 1 to -10dB): #x-aud-lvl out.amplified_audio.1.audio.1,-10 Default Ethernet Parameters IP Address: Subnet mask: Gateway: 192.168.1.39 255.255.0.0 192.168.0.1 UDP Port #: TCP Port #: Username/Password 50000 5000 Admin/Admin Factory Reset Recessed Button Protocol 3000: Web Pages: Press and hold for 5 seconds to reset the configuration to its default parameters. "#factory" command. In the Settings page, click Factory Reset.