Hotpoint Gas Range RGBS400DMBB | Colonial Appliance
PROPANE (LP) CONVERSION INSTRUCTIONS WARNING Explosion Hazard Death or serious injury can result from failure to follow these instructions. 6HUYLFHE\DTXDOLILHGVHUYLFHWHFKQLFLDQRQO\ 6KXWRIIJDVVXSSO\DQGGLVFRQQHFWSRZHUEHIRUHVHUYLFLQJ 5HFRQQHFWDOOJURXQGLQJGHYLFHVDIWHUVHUYLFH · Replace all parts and panels before operating. 7KHSUHVVXUHUHJXODWRUDQGWKHEXUQHURUL¿FHVDUHVHWIRU natural gas. To use propane (LP) gas, the regulator and burner RUL¿FHVPXVWEHFRQYHUWHG WARNING 'RQRWRSHUDWHWKHFRRNWRSRURYHQ burners of this range when using propane (LP) (bottled) gas EHIRUHFRQYHUWLQJWKHSUHVVXUHUHJXODWRUDQGEXUQHURUL¿FHV for propane (LP) gas use. Failure to do so could cause high ÀDPHVDQGWR[LFIXPHVZKLFKFDQUHVXOWLQVHULRXVLQMXU\ 7KHSURSDQHRUL¿FHVIRUWKHFRRNWRSEXUQHUVDUHVKLSSHGRQ the back of the range in the location shown. 3URSDQH&RQYHUVLRQ.LW TOOLS REQUIRED: · Adjustable wrench · 1/2" Open-end wrench · 3KLOOLSVKHDGVFUHZGULYHU · )ODWEODGHGVFUHZGULYHU (blade approximately 3/32" across) · 1XWGULYHUV´´ or 7mm To adjust your range for use with propane (LP) gas, follow these instructions: 1. Disconnect all electrical power, at the main circuit breaker or fuse box. 6KXWRWKHJDVVXSSO\WRWKHUDQJHE\FORVLQJWKHPDQXDO VKXWRYDOYH CONVERTING THE PRESSURE REGULATOR CONVERTING THE COOKTOP BURNERS The pressure regulator is located on the rear of the range. 6RPHPRGHOVZLOOKDYHDPHWDOVKLHOGSURWHFWLQJWKHUHJXODWRU WKDWPXVWEHUHPRYHGIRUFRQYHUVLRQDQGUHLQVWDOOHGZKHQ FRQYHUVLRQLVFRPSOHWH7KHSUHVVXUHUHJXODWRULVORFDWHGLQWKH ORZHUOHIWKDQGVLGHRIWKHUDQJHDVYLHZHGIURPWKHIURQWOHIW $5 HPRYHWKHWRSJUDWHVEXUQHUFDSVDQGEXUQHUKHDGV Burner cap Orifice located through this opening Burner head Base ',QVWDOOWKHSURSDQH/3RUL¿FHVLQWKHLUSUHFLVHORFDWLRQV Propane Blue/Brown Propane Red/Yellow LR RR LF RF Pressure Regulator *DV9DOYH NOTICE: ,I\RXDUHXVLQJSURSDQH/3ERWWOHGJDVDOO adjustments described in the following steps must be made before you make any burner adjustments. 1. Use an adjustable wrench to unscrew the hex-nut cap from the pressure regulator. & RPSOHWHO\UHPRYHWKHSURWHFWLYHSODVWLFFDSRWKH threaded metal cap. Rotate cap counter- clockwise to loosen NAT PROPANE Cap assembly Burner construction %8 VLQJDPPRU´QXWGULYHUUHPRYHWKHWRSEXUQHU RUL¿FHV7KHVHPD\EHDFFHVVHGWKURXJKWKHEXUQHU opening in the base. Propane Blue/Brown Propane Blue/Magenta NOTICE: 6DYHWKHVHRUL¿FHVIRUIXWXUHFRQYHUVLRQEDFNWRQDWXUDOJDV &5 HPRYHWKHSURSDQH/3RUL¿FHVIURPWKHER[SURYLGHG 7KHSURSDQH/3RUL¿FHVKDYHWKHOHWWHU³/´RQWKHWRS To aid in identifying the proper location for the propane (LP) RUL¿FHVGXULQJFRQYHUVLRQIURP1DWXUDO*DVWR3URSDQH /3*DVFRORUFRGHVKDYHEHHQDGGHGWRWKHVLGHRUWRSRI WKHRUL¿FH6HHWKHFKDUWEHORZ(DFKRUL¿FHPD\DOVRVKRZ DVHULHVRIHQJUDYHGPDUNV,,,,,,ORFDWHGRQWKHWRS 7RSUHYHQWOHDNDJHPDNHVXUHWKHRUL¿FHVSXGVDUHVHFXUHO\ screwed into the gas supply tubes. ( ,QVWDOOWKHROGRUL¿FHVSXGVLQWRWKHPHWDOER[RUEUDFNHW along with these instructions, and replace onto the back of the UDQJHIRUSRVVLEOHIXWXUHFRQYHUVLRQ 95 Denotes 0.95mm Orifice size opening Denotes LP (Propane) III 7 XUQWKHPHWDOFDSVRWKHW\SHRIJDVEHLQJFRQYHUWHGWRLV GLVSOD\HGDQGUHSODFHWKHSURWHFWLYHSODVWLFFRYHU 4. Screw the hex-nut cap back into the regulator. (Do not over tighten) BURNER OUTPUT RATINGS: BTU/HR Propane (LP) Gas 10" W.C.P. BURNER RF BTU RATE 12,000 ORIFICE SIZE (mm) 0.039" (0.99) COLOR MARKING Blue/Magenta 99L LF 9,500 0.035" (0.89) Blue/Brown 89L RR 5,000 0.026" (0.66) Red/Yellow 66L LR 9,500 0.035" (0.89) Blue/Brown 89L OVEN 16,000 0.048" (1.21) Pink 0.048 PROPANE (LP) CONVERSION INSTRUCTIONS 31-2000947 Rev. 1 09-24 JGBS10, JGBS30, JGBS61, RGBS300, RGBS400, JGBS60, RGBS330 and XGBS400 CONVERTING THE OVEN BURNERS WARNING The following adjustments must be made EHIRUHWXUQLQJRQWKHJDVWRWKHRYHQEXUQHU)DLOXUHWR GRVRFRXOGUHVXOWLQVHULRXVLQMXU\GXHWRKLJKÀDPHVDQG toxic fumes. OVEN BURNER ORIFICE 5 HPRYHRYHQGRRUEURLOGUDZHURYHQERWWRPDQGEXUQHU 7KHRYHQEXUQHURUL¿FHLVORFDWHGEHKLQGWKHGUDZHU2Q VRPHPRGHOVDPHWDOVKLHOGPXVWEHUHPRYHG 7 RFRQYHUWWRSURSDQH/3UHSODFHRYHQRUL¿FHZLWKWKH one supplied in kit with range. NOTICE: 6DYHWKHVHRUL¿FHVIRUIXWXUHFRQYHUVLRQEDFNWRQDWXUDOJDV 2YHQEXUQHU air shutter 2YHQ orifice NOTICE: 7KLVSURGXFWFDQQRWEHFRQYHUWHGWRSURSDQH/3E\ DGMXVWLQJWKHRYHQRUL¿FHV7KHRUL¿FHVPXVWEHUHSODFHG for propane (LP). ADJUSTING AIR SHUTTER SETTINGS FOR OVEN BURNERS 7KHDLUVKXWWHUVVKRXOGEHWXUQHGWRWKHPDUNHGVHWWLQJV1*RU propane or set according to the following table. BURNER Bake/Broil AIR SHUTTER SETTING FOR PROPANE 0.500" AIR SHUTTER SETTING FOR NG 0.500" : LWKD3KLOOLSVKHDGVFUHZGULYHUORRVHQWKHVFUHZV securing the air shutter on the bake burner. Adjust the air shutter to fully open. 2. Turn on the gas. 3. Turn on the electricity. 5HLQVWDOOWKHRYHQGRRU Screw Air shutter 5. Turn on the bake burner. 2YHQEXUQHUÀDPHPXVWEHREVHUYHGZLWKWKHGRRUFORVHG WRSURSHUO\FKHFNÀDPHFKDUDFWHULVWLFV $ V\RXZDWFKWKHÀDPHZLWKWKHRYHQGRRUFORVHGFKHFN WKHIROORZLQJWKURXJKWKHRYHQGRRUZLQGRZRUWKURXJKWKH broil drawer opening. D,IWKHÀDPHVDUH\HOORZRSHQWKHDLUVKXWWHUPRUH E,IWKHÀDPHVEORZDZD\RUÀXWWHUIURPWKHEXUQHUFORVH the air shutter slightly. WARNING ,I\RXDWWHPSWWRPHDVXUHWKHLQQHUFRQH RIWKHÀDPHSOHDVHXVHFDXWLRQEXUQVFRXOGUHVXOW & KHFNLQJWKHÀDPHVL]H ,WVKRXOGEHDSSUR[LPDWHO\´WR 3/4" long for the bake burner. 7 KHFRPEXVWLRQTXDOLW\RIWKH EXUQHUÀDPHVQHHGVWREH GHWHUPLQHGYLVXDOO\ 127(,IEXUQHUÀDPHVORRNOLNH$IXUWKHUDLUVKXWWHU adjustment to the bake buner is required. Normal EXUQHUÀDPHVVKRXOGORRNOLNH%RU&GHSHQGLQJRQ the type of gas you use. With propane (LP) gas, some \HOORZWLSSLQJRQWKHRXWHUFRQHVLVQRUPDO )RUHLJQSDUWLFOHVLQWKHJDVOLQHPD\FDXVHDQRUDQJHÀDPHDW ¿UVWEXWWKLVZLOOVRRQGLVDSSHDU 8. When all adjustments are made and the results are satisfactory: a. Retighten the air shutter screws. E5HSODFHWKHRYHQERWWRP SPECIAL NOTE: To convert the oven back to natural gas, reverse the instructions given in making propane (LP) adjustments. NOTICE: 2QFHWKHFRQYHUVLRQLVFRPSOHWHDQGFRQ¿UPHG¿OORXWWKH propane (LP) sticker and include your name, organization DQGGDWHFRQYHUVLRQZDVPDGH$SSO\WKHVWLFNHUWRWKH range near the regulator to alert others in the future that WKLVDSSOLDQFHKDVEHHQFRQYHUWHGWRSURSDQH/3,I FRQYHUWLQJEDFNWRQDWXUDOJDVIURPSURSDQH/3SOHDVH UHPRYHWKHVWLFNHUVRRWKHUVNQRZWKHDSSOLDQFHLVVHWWR use natural gas. ADDITIONAL INFORMATION BURNER OUTPUT RATINGS: BTU/HR NG (Natural) Gas 5" W.C.P. BURNER RF BTU RATE 13,000 ORIFICE SIZE (mm) 0.064" (1.62) COLOR Black/Red MARKING 162N LF 9,500 0.053" (1.36) *UHHQ 136N RR 5,000 0.040" (1.01) White/Purple 101N LR 9,500 0.053" (1.36) *UHHQ 136N OVEN 18,000 0.076" (1.93) None .076 198 N III Denotes 1.98mm Orifice size opening Denotes Natural Gas (A) Yellow flames: Further Adjustment Required (B) Yellow tips on outer cones: Normal for Propane (LP) Gas (C) Soft blue flames: Normal for Natural Gas PROPANE (LP) CONVERSION INSTRUCTIONS 31-2000947 Rev. 1 09-24 JGBS10, JGBS30, JGBS61, RGBS300, RGBS400, JGBS60, RGBS330 and XGBS400Adobe InDesign 19.5 (Windows) Acrobat Distiller 24.0 (Windows)