User Manual for ACME models including: Coolie 545 RGBW LED, Coolie 545, RGBW LED, LED

yifeng yf

ACME Lights


File Info : application/pdf, 20 Pages, 1.54MB

PDF preview unavailable. Download the PDF instead.

16430986252aec1f09bb01c294
CONTENTS 1. Safety Instructions.................................................................................................. 2 2. Technical Specifications .......................................................................................... 4 3. How To Set The Unit ............................................................................................... 5
3.1 Control Panel .................................................................................................... 5 3.2 Main Function .................................................................................................. 5 4. Control By Universal DMX Controller.................................................................... 11 4.1 DMX512 Connection ...................................................................................... 11 4.2 Address Setting............................................................................................... 12 4.3 DMX512 Configuration ................................................................................... 12 5. Troubleshooting ................................................................................................... 18 6. Fixture Cleaning ................................................................................................... 18
1G

1. Safety Instructions
Please read the instruction carefully which includes important information about the installation, usage and maintenance.
WARNING
Please keep this User Guide for future consultation. If you sell the unit to another user, be sure that they also receive this instruction manual. Important: Damages caused by the disregard of this user manual are not subject to warranty. The dealer will not accept liability for any resulting defects or problems.  Unpack and check carefully to ensure that there is no transportation damage before using the
unit.  This product is suitable for wet locations. Do not immerse in water.  DO install and operate by qualified operator.  DO NOT allow children to operate the fixture.  Use safety chain when fixing the unit. Handle the unit by carrying its base instead of head
only.  The unit must be installed in a location with adequate ventilation, at least 50cm from adjacent
surfaces.  Be sure that no ventilation slots is blocked, otherwise the unit will be overheated.  Before operation, ensure that you are connecting this product to the proper voltage in
accordance with the specifications in this manual or on the product's specification label.  It's important to ground the yellow/green conductor to earth in order to avoid electric shock.  Minimum ambient temperature TA: 0. Maximum ambient temperature TA: 40. Do not
operate this product at a lower or higher temperature.  DO NOT connect the device to any dimmer pack.  Keep flammable materials away from the fixture while operating to avoid fire hazard.  Make sure the power cord is not crimped or damaged; replace it immediately if damaged.  Avoid any flammable liquids, water or metal from entering the unit. Once it happens, cut off
2G

the mains power immediately.  DO NOT operate in a dirty or dusty environment. DO clean the fixture regularly.  DO NOT touch any wire during operation as there might be a hazard of electric shock.  Avoid entanglement of the power cord with other wires.  In the event of serious operating problem, stop using the unit immediately.  Never turn on and off the unit time after time.  The housing, the lenses, or the ultraviolet filter must be replaced if they are visibly damaged.  DO NOT open the housing as there are no user serviceable parts inside.  DO NOT attempt to operate this unit if it becomes damaged. DO NOT attempt any repairs
yourself. Repairs carried out by unskilled people can lead to damage or malfunction. Please contact the nearest authorized technical assistance center if needed.  Disconnect this product from its power source before servicing.  DO use the original packaging if the device is to be transported.  Avoid direct eye exposure to the light source while the product is on.  DO NOT operate this product if you see damage on the housing, shields, or cables. Have the damaged parts replaced by an authorized technician at once.
Installation: The fixture should be fixed on the clamp. Always ensure that the unit is firmly fixed to avoid vibration and slipping off during operation. Ensure that the trussing or area of installation must be able to hold 10 times the weight without any deformation. Always install a safety cable that can hold at least 12 times the weight of the fixture when installing. DO install and operate by qualified operator. It must be installed in a place where there is out of the reach of people.
3G

2. Technical Specifications
Power Voltage: 100-240V~ 50/60Hz Power Consumption: 170W Light Source: 54x3W RGBW LED Beam Angles: 19° Control: DMX Channel: 4/5/7/8 channel Control Mode: DMX512, Primary/Secondary Firmware Upgrade: Update via DMX link Construction: Display: LED display Data In/Out Socket: 3-pin XLR socket Protection Rating: IP66 Features: Outstanding color mixing effect Preset program in stand-alone mode 0~100% smooth dimming; various strobe speeds Dimension/Weight: 302x230x350mm, 9.1kgs 11.9"x9.1"x13.8"in, 20.1lbs Photometric Diagram:
4G

3. How To Set The Unit 3.1 Control Panel

1. POWER IN/OUT:

Water proof connectors for power input/output

2. DMX IN/OUT:

Water proof connectors for DMX512 operation, use 3-pin XLR cable to link the units together

3. Display:

To show the menu and the selected functions

Button:

4. MENU

To select the programming functions

5. UP

To go backward in the selected functions

6. DOWN To go forward in the selected functions

7. ENTER

To confirm the selected functions

3.2 Main Function
Turn on the unit, press the MENU button into menu mode, and press the UP/DOWN button until the required function is shown on the monitor. Select the function by pressing the ENTER button. Use the UP/DOWN button to choose the submenu, press the ENTER button to store and automatically return to the last menu. Press the MENU button or let the unit idle 30 seconds to exit menu mode. The main functions are shown below:

5G

Once you set

to

, after running in show mode for 5 minutes

without any change or restarting the unit, the key board become locked.

Press ENTER button to enable the menu, the display will show

, press

UP and DOWN button until it shows

, then press ENTER to unlock.

6G

DMX Address

Press the MENU button up to when the

is shown on the display. Press ENTER button

and the display will blink. Use DOWN and UP button to change the DMX512 address. Once the

address has been selected, press ENTER button to setup or automatically exit menu mode without

any change after 30 seconds. Back to the previous functions without any change press MENU

button.

Channel Mode

Press the MENU button up to when the

is shown on the display. Press ENTER button

and the display will blink. Use DOWN and UP button to select the

(4 channels),

(5 channels),

(7 channels) or

(8 channels). Once select, press

ENTER button to setup or automatically exit menu mode without any change after 30 seconds. To go back to the functions without any change press the MENU button.

Show Mode

Press the MENU button up to when the

is shown on the display. Press ENTER button

and the display will blink. Use DOWN and UP button to select the

(show 1) ...

(show 16) or

(Manual). After select the show mode, use DOWN and UP button to

adjust the value for fade mode and speed mode. Once select, press ENTER button to store or

automatically return to the main functions without any change after 30 seconds. To go back to the

previous functions without any change press the MENU button.

Primary/Secondary Mode

Press the MENU button up to when the

is shown on the display. Press ENTER button

and the display will blink. Use DOWN and UP button to select the

(Primary),

(Secondary 1) or

(Secondary 2). Once select, press ENTER button to store or

automatically return to the main functions without any change after 30 seconds. To go back to the previous functions without any change press the MENU button.

7G

Dimmer Curve

Press the MENU button up to when the

is shown on the display. Press ENTER button

and the display will blink. Use DOWN and UP button to select the

(Dimmer Curve

1) ...

(Dimmer Curve 4). Once select, press ENTER button to store or automatically return

to the main functions without any change after 30 seconds. To go back to the previous functions

without any change press the MENU button.

Dimmer Speed

Press the MENU button up to when the

is shown on the display. Press ENTER button

and the display will blink. Use DOWN and UP button to select the

(Smooth) or

(Fast). Once select, press ENTER button to store or automatically return to the main

functions without any change after 30 seconds. To go back to the previous functions without any

change press the MENU button.

DMX Status Press the MENU button up to when the

is shown on the display. Press ENTER button

and the display will blink. Use DOWN and UP button to select the

(Primary/Secondary

Mode) or

(Blackout Mode). Once select, press ENTER button to store or automatically

return to the main functions without any change after 30 seconds. To go back to the previous functions without any change press the MENU button.

LED

Press the MENU button up to when the

is shown on the display. Press ENTER button

and the display will blink. Use DOWN and UP button to select the

(On) or

(Off). Once select, press ENTER button to store or automatically return to the main functions

without any change after 30 seconds. To go back to the previous functions without any change

press the MENU button.

8G

Invert Display

Press the MENU button up to when the

is shown on the display. Press ENTER button

and the display will blink. Use DOWN and UP button to select the

(Normal) or

(Invert Display). Once select, press ENTER button to store or automatically return to the

main functions without any change after 30 seconds. To go back to the previous functions without

any change press the MENU button.

White Balance

Press the MENU button up to when the

is showing on the display. Press ENTER button

and the display will blink. Use DOWN and UP button to select the

(Red),

(Green) or

(Blue). Once the mode has been selected, press the DOWN and Up button to

select the value from 125 to 255, press the ENTER button to setup or automatically return to the

main functions without any change after 30 seconds. To go back to the previous functions without

any change press the MENU button.

Manual Test

Press the MENU button up to when the

is showing on the display. Press ENTER button

and the display will blink. Use DOWN and UP button to select the

(Red),

(Green),

(Blue),

(White),

(Color),

(Dimmer) or

(Strobe). Once the mode has been selected, press the DOWN and Up button to select the value

from 0 to 255, press the ENTER button to setup or automatically return to the main functions

without any change after 30 seconds. To go back to the previous functions without any change

press the MENU button.

Keyboard Lock

Press the MENU button up to when the

is showing on the display. Press ENTER button

and the display will blink. Use DOWN and UP button to select the

(Keyboard lock On) or

(Keyboard lock Off). Once select, press the ENTER button to setup or automatically

return to the main functions without any change after 30 seconds. Back to the previous functions

press MENU button.

9G

Auto Test

Press the MENU button up to when the

is blinking on the display. Press ENTER button

and the unit will run self-test by built-in program. To go back to the functions press the MENU

button again.

Fixture Temperature

Press the MENU button up to when the

is blinking on the display. Press ENTER button

and the display will show the temperature of the unit. To go back to the functions press the MENU

button again.

Fixture Use Hour

Press the MENU button up to when the

is blinking on the display. Press ENTER button

and the display will show the working hours of the unit. To go back to the functions press the

MENU button.

Software Version

Press the MENU button up to when the

is blinking on the display. Press ENTER button

and the display will show the version of software of the unit. To go back to the functions press the

MENU button again.

10G

4. Control By Universal DMX Controller 4.1 DMX512 Connection
1. At last unit, the DMX cable has to be terminated with a terminator. Solder a 120-ohm 1/4W resistor between pin 2(DMX-) and pin 3(DMX+) into a 3-pin XLR-plug and plug it in the DMX-output of the last unit. 2. Connect the unit together in a "daisy chain" by XLR plug cable from the output of the unit to the input of the next unit. The cable can only be used in series and cannot be connected in parallel. DMX 512 is a very high-speed signal. Inadequate or damaged cables, soldered joints or corroded connectors can easily distort the signal and shut down the system. 3. The DMX output and input connectors are pass-through to maintain the DMX circuit, when one of the units' power is disconnected. 4. Each lighting unit needs to have a DMX address to receive the data by the controller. The address number is between 1-512. 5. The end of the DMX 512 system should be terminated to reduce signal errors. 6. 3 pin XLR connectors are more popular than 5 pins XLR.
3 pin XLR: Pin 1: GND, Pin 2: Negative signal (-), Pin 3: Positive signal (+) 5 pin XLR: Pin 1: GND, Pin 2: Negative signal (-), Pin 3: Positive signal (+), Pin4, Pin5 not used.
11G

4.2 Address Setting

Use universal DMX controller to control the units, you have to set DMX address from 1 to 512

channel so that the units can receive DMX signal.

Press the MENU button up to when the

is showing on the display. Press the ENTER

button and the display will blink. Use the UP/DOWN button to change the DMX512 address. Once

the address has been selected, press and keep the ENTER button pressed up to when the display

stops blinking or storing automatically 30 seconds later. To go back to the functions without any

change press the MENU button again.

Please refer to the following diagram to address your DMX512 channel for the first 4 units:

Channel mode

Unit 1 Address

Unit 2 Address

Unit 3 Address

Unit 4 Address

4 Channels

1

5

9

13

5 Channels

1

6

11

16

7 channels

1

8

15

22

8 channels

1

9

17

25

4.3 DMX512 Configuration
Please refer to below configurations to control the fixtures Attentions: 1. The unit will maintain the last condition until reset if you cut-off the DMX signal. 2. For the channel Function, keep the value for about 3 seconds, then the corresponding function will take into effect.

12G

4 Channels Mode (Mode 1):

CHANNEL

VALUE

1 0-255

2

0-255

3

0-255

4

0-255

5 Channels Mode (Mode 2):

CHANNEL

VALUE

1

0-255

2 0-255

3

0-255

4

0-255

5

0-255

7 Channels Mode (Mode 3):

CHANNEL

VALUE

1

0-255

2 0-255

3

0-255

4

0-255

5

FUNCTION RED
0%100% GREEN
0%100% BLUE
0%100% WHITE
0%100%
FUNCTION RED
0%100% GREEN
0%100% BLUE
0%100% WHITE
0%100% DIMMER 0%100%
FUNCTION RED
0%100% GREEN
0%100% BLUE
0%100% WHITE
0%100% PRESET COLOR
13G

0-7 8-15 16-23 24-31 32-39 40-47 48-55 56-63 64-71 72-79 80-87 88-95 96-103 104-111 112-119 120-127 128-135 136-143 144-151 152-159 160-167 168-175 176-183 184-191 192-199 200-207 208-215 216-223 224-231 232-239 240-247 248-254 255

0-7

8-15

16-131

132-139

6

140-181

182-189

190-231

232-239

240-247

248-255

OFF PRESET COLOR 1 PRESET COLOR 2 PRESET COLOR 3 PRESET COLOR 4 PRESET COLOR 5 PRESET COLOR 6 PRESET COLOR 7 PRESET COLOR 8 PRESET COLOR 9 PRESET COLOR 10 PRESET COLOR 11 PRESET COLOR 12 PRESET COLOR 13 PRESET COLOR 14 PRESET COLOR 15 PRESET COLOR 16 PRESET COLOR 17 PRESET COLOR 18 PRESET COLOR 19 PRESET COLOR 20 PRESET COLOR 21 PRESET COLOR 22 PRESET COLOR 23 PRESET COLOR 24 PRESET COLOR 25 PRESET COLOR 26 PRESET COLOR 27 PRESET COLOR 28 PRESET COLOR 29 PRESET COLOR 30 PRESET COLOR 31
Off STROBE
OFF OPEN STROBE FROM SLOW TO FAST OPEN FAST CLOSE SLOW OPEN OPEN FAST OPEN SLOW CLOSE OPEN RANDOM STROBE OPEN
14G

7

0-255

8 Channels Mode (Mode 4):

CHANNEL

VALUE

1

0-255

2 0-255

3

0-255

4

0-255

001-004

005-009

010-013

014-018

019-022

023-027

028-031

032-036

037-040

041-045

046-049

050-054

5

055-058

059-063

064-067

068-072

073-076

077-081

082-085

086-090

091-094

095-099

100-103

104-108

109-112

113-117

DIMMER 0%100%
FUNCTION RED
0%100% GREEN
0%100% BLUE
0%100% WHITE
0%100% CTO(8000K-2500K)
8000K 7900K 7800K 7700K 7600K 7500K 7400K 7300K 7200K 7100K 7000K 6900K 6800K 6700K 6600K 6500K 6400K 6300K 6200K 6100K 6000K 5900K 5800K 5700K 5600K 5500K
15G

118-121 122-126 127-130 131-135 136-139 140-144 145-148 149-153 154-157 158-162 163-166 167-171 172-175 176-180 181-184 185-189 190-193 194-198 199-202 203-207 208-211 212-216 217-220 221-225 226-229 230-234 235-238 239-243 244-247 248-255

0-7

8-15

16-23

24-31

32-39

6

40-47

48-55

56-63

64-71

72-79

80-87

88-95

96-103

5400K 5300K 5200K 5100K 5000K 4900K 4800K 4700K 4600K 4500K 4400K 4300K 4200K 4100K 4000K 3900K 3800K 3700K 3600K 3500K 3400K 3300K 3200K 3100K 3000K 2900K 2800K 2700K 2600K 2500K PRESET COLOR OFF PRESET COLOR 1 PRESET COLOR 2 PRESET COLOR 3 PRESET COLOR 4 PRESET COLOR 5 PRESET COLOR 6 PRESET COLOR 7 PRESET COLOR 8 PRESET COLOR 9 PRESET COLOR 10 PRESET COLOR 11 PRESET COLOR 12
16G

104-111 112-119 120-127 128-135 136-143 144-151 152-159 160-167 168-175 176-183 184-191 192-199 200-207 208-215 216-223 224-231 232-239 240-247 248-254
255

0-7

8-15

16-131

132-139

7

140-181

182-189

190-231

232-239

240-247

248-255

8

0-255

PRESET COLOR 13 PRESET COLOR 14 PRESET COLOR 15 PRESET COLOR 16 PRESET COLOR 17 PRESET COLOR 18 PRESET COLOR 19 PRESET COLOR 20 PRESET COLOR 21 PRESET COLOR 22 PRESET COLOR 23 PRESET COLOR 24 PRESET COLOR 25 PRESET COLOR 26 PRESET COLOR 27 PRESET COLOR 28 PRESET COLOR 29 PRESET COLOR 30 PRESET COLOR 31
Off
STROBE OFF OPEN
STROBE FROM SLOW TO FAST OPEN
FAST CLOSE SLOW OPEN OPEN
FAST OPEN SLOW CLOSE OPEN
RANDOM STROBE OPEN
DIMMER 0%100%

17G

5. Troubleshooting
Following are a few common problems that may occur during operation. Here are some suggestions for troubleshooting: A. The unit does not work, no light and the fan does not work 1. Check the connected power. 2. Measure the voltage. 3. Check the power indicator to see whether it can be lit up or not. B. Not responding to the DMX controller 1. Check whether the DMX connectors and the DMX cables are connected correctly. 2. Check whether the DMX address is correctly set. 3. If the intermittent DMX signal problem occurs, check whether the XLR socket and the signal cable are well connected. 4. Try it with another DMX controller. 5. Check whether the DMX cables run near or alongside to the high-voltage cables, which may damage or interfere with the signal circuit. C. One of the channels is not working well 1. The stepper motor might be damaged or the cable connected to the PCB might be broken. 2. The motor's drive IC on the PCB might be out of condition.
6. Fixture Cleaning
It is absolutely essential that the fixture is kept clean to ensure the maximum light-output and allow the fixture to function reliably throughout its life. The fixture must be cleaned regularly to avoid dust, dirt and smoke-fluid residues building up on or within the fixture. The cleaning frequency depends on the application environment. Clean the fixture immediately if the dust enters it to avoid damage to the optical lens due to excessive dust.
 A soft lint-free cloth moistened with any good glass cleaning fluid is recommended, under no circumstances should solvents be used.
 Always dry the parts carefully.  Clean the external optical lens at least every 20 days.
18G

Innovation, Quality, Performance


yifeng Adobe PDF Library 11.0