Aetria® Network Manager Quick Start Guide
Engineering the world's best visual solutions

Aetria Network Manager Quick Start Guide
Thank you for purchasing the Network Manager Server. The Network Manager Server is available in two different models, the one supplied is determined by which Aetria license has been purchased: Aetria-SRV1 for Aetria-LIC-UNL Aetria-SRV2 for Aetria-LIC-VSN The aim of this document is to quickly guide you through the process of initial setup. For more detailed information, relevant user guides can be downloaded from www.datapath.co.uk.
CONTENTS
1 x Aetria Network Manager Server (dual servers will be supplied for environments requiring High Availability) Mains power cable (x 2 for Aetria-SRV1) 1 x Front Panel cover with key 1 x Keyboard User documentation
2

Aetria Network Manager Quick Start Guide AETRIA NETWORK MANAGER SERVER REAR PANEL

1

23

8

9

4 56 7
1 Serial Port. 2 Ethernet Port 1 ­ Connect to corporate network. 3 Ethernet Port 2 ­ Connect to AV network. 4 VGA Port. 5 DRAC Ethernet Port ­ Connect to corporate network if the High Availability within Aetria Command
Center is to be configured. 6 USB 2.0 Gen Port. 7 USB 3.2 Gen Port. 8 Power supply. 9 Redundant power supply (Aetria-SRV1 only).
3

Aetria Network Manager Quick Start Guide AETRIA NETWORK MANAGER SERVER FRONT PANEL
10 10 On/Off Switch.
4

Aetria Network Manager Quick Start Guide HOW TO CONNECT THE AETRIA NETWORK MANAGER SERVER
Connect the keyboard to the one of the USB ports on the rear of the server. Using network cables, connect the Ethernet port 1 to the corporate network and port 2 to the AV network. If a High Availability configuration is to be used, a network cable should be connected from the IDRAC port to the corporate network. Connect a display to the VGA port. Finally, connect the mains power cables (2 x If configuring High Availability functionality).
5

Aetria Network Manager Quick Start Guide

GETTING STARTED WITH AETRIA NETWORK MANAGER

1

Warning!

It should be noted that the Aetria Network Manager interface should only be accessed by trained staff. Access by untrained staff could lead to product failure resulting in system downtime.

The system will automatically boot the Datapath Aetria Network Manager option as highlighted left and continue with the configuration of the Aetria Network Manager starting with language selection.

2

Select the required language using the arrow

keys then press the Enter key to select the

model of keyboard being used.

3

If the model is not listed, select a generic

keyboard then press the Enter key.

6

Aetria Network Manager Quick Start Guide

4

A series of screens will then be displayed,

prompting the user to select the required

keyboard configuration. The example on the

left is for a standard UK keyboard.

5

Select the layout that matches the keyboard to

be used in this machine.

6

Select the configuration for the AltGr key

if required.

7

Aetria Network Manager Quick Start Guide

7

Select a Compose key.

After configuring the keyboard an authorization prompt is displayed.

8

Enter the Datapath user password. A random

password will have been generated during the

build of the Aetria Network Manager server prior

to dispatch and passed to the commissioning

team. Enter the password to continue.

9

The Initial Appliance Configuration menu is

then displayed. Select Yes to continue. Select

No and the configuration process will return to

Language selection screen.

8

Aetria Network Manager Quick Start Guide

10

An opportunity to change the Datapath

password is presented. Select Yes and follow

the prompts to enter then re-enter a new

password. It should be noted that a new

password cannot be recovered if lost, therefore

password details should be recorded and stored

safely. Failure to do so could reduce the ability

for Datapath support staff to help with any

issues that may occur.

11

Enter then re-enter the new password then click

on OK.

12

Once the new password details have been

entered successfully, click on OK.

9

Aetria Network Manager Quick Start Guide

13

The next step of the configuration is to select

the Network Interface Card (NIC) for the

Corporate network.

An Aetria Network Manager appliance will normally have two NICs. Select the NIC which is connected to the Corporate network using the space bar, then select OK and press Enter.

The NIC not selected for Corporate network will automatically be assigned to the AV network.

14

A confirmation dialog is then displayed. This

should be checked to ensure the correct NICs

have been selected.

Confirm the NIC selection and select Yes and the Corporate IP Address dialog is displayed.

15

Set the hostname for the Aetria Network Manager:

Enter the fully qualified domain name then select

Yes and press Enter. A confirmation dialog is then

displayed, this should be checked for errors. If there

are any errors in the hostname, select No and

re-enter the hostname correctly.

10

Aetria Network Manager Quick Start Guide

16

Once satisfied the hostname is correct, select Yes

and the Corporate IP Address Menu is displayed in

the next dialog.

17

Enter the IP Address of the Aetria Network

Manager and select OK and the Corporate Subnet

Mask dialog is displayed.

18

Enter the Corporate Subnet Mask and select OK.

The Corporate Gateway dialog will then be

displayed.

11

Aetria Network Manager Quick Start Guide

19

Enter the IP address of the Corporate Gateway

and select OK and the Confirm IP Details dialog

is displayed.

20

Check and confirm the IP Details. Select Yes and

the DNS Servers dialog is displayed.

21

Enter the IP address(es) of the DNS Server(s). If

more than one DNS server is required, ensure each

IP address is separated by a space. Select OK and

the Timezone Selection Menu is displayed.

12

Aetria Network Manager Quick Start Guide

22

The default timezone is Europe/London, if this

is the required timezone select Yes, to select

a different timezone, select No and the Time

Configuration menu is displayed.

23

Follow the prompts to choose the required

location which will enable the timezone to

be set correctly.

24

13

Aetria Network Manager Quick Start Guide

25

Select OK to confirm the Timezone selection.

26 27
14

After a short pause whilst the network settings are being activated, the screen will return to the authentication screen.
The top line of the screen will show the hostname and the IP address that has just been configured. Log back on and the ANM Setup Menu is displayed.

Aetria Network Manager Quick Start Guide
CONFIGURE TIME AND DATE
To configure the time and date, select Time and Date Configuration from the Aetria Network Manager Setup Menu and the Time Configuration menu is displayed. By default, the system will attempt to set its time by contacting Internet based Network Time Protocol (NTP) servers. NTP is the networking protocol for clock synchronization on computer networks. If access to the Internet is restricted, an option is provided to configure a custom NTP server using the Change NTP Configuration menu option:

28

Select Change NTP Configuration, select OK and

the NTP Server dialog is displayed.

29

Enter the hostname or IP address of the required

NTP server. Using the word DEFAULT will tell the

appliance to use the Internet based NTP servers

(pool.ntp.org). Select OK to continue.

15

Aetria Network Manager Quick Start Guide

30

Once the server has successfully restarted,

select OK.

31

The NTP status can be viewed by selecting Check

NTP Status from the Time Configuration menu.

32 16

This will show if the time is correctly synchronized. Select OK to continue. Note that it may take several minutes for the time to synchronize. Should the configured NTP server not be reachable, the Aetria Network Manager appliance will fall back to using its local clock as a time source.
To display a digital clock on the screen, return to the Time Configuration menu and select Clock View. The following dialog is displayed:

Aetria Network Manager Quick Start Guide

33

To display the clock select `OK' and the clock is

displayed across the screen. Press CTRL-ALT-F2

to return to the menu.

Once the above steps are complete, access the Aetria Command Center using a Chrome, Edge or Safari browser on a PC or laptop connected to the Corporate network using the URL https://<FQDN>

17

Aetria Network Manager Quick Start Guide COPYRIGHT STATEMENT
© Datapath Ltd., England, 2022 Datapath Limited claims copyright on this documentation. No part of this documentation may be reproduced, released, disclosed, stored in any electronic format, or used in whole or in part for any purpose other than stated herein without the express permission of Datapath Limited. Whilst every effort is made to ensure that the information contained in this Quick Start Guide is correct, Datapath Limited make no representations or warranties with respect to the contents thereof, and do not accept liability for any errors or omissions. Datapath reserves the right to change specification without prior notice and cannot assume responsibility for the use made of the information supplied. All registered trademarks used within this documentation are acknowledged by Datapath Limited.
18

Aetria Network Manager Quick Start Guide CERTIFICATION
EU ­ Class A Declaration of Conformity
Datapath Ltd declares that this product complies with the essential requirements and other relevant provisions of Directives 2014/30/EU, 2014/35/EU and 2011/65/EU. A copy of our Declaration of conformity is available on request. Datapath Limited Bemrose House Bemrose Park Wayzgoose Drive Derby, DE21 6XQ UK A full list of product compliance certifications can be found in the product User Guide on the Documentation Media supplied with the system.
19

Datapath UK and Corporate Headquarters Bemrose House, Bemrose Park, Wayzgoose Drive, Derby, DE21 6XQ, United Kingdom
+44 (0) 1332 294 441 sales-uk@datapath.co.uk
Datapath North America 2490 General Armistead Ave, Suite 102, Norristown, PA 19403, USA
+1 484 679 1553 sales-us@datapath.co.uk
www.datapath.co.uk

QSG-AET-EN2-V3.1



References

Adobe PDF Library 16.0.7 Adobe InDesign 17.3 (Macintosh)