Cables, buffer solutions and probe accessories
Immersion probe holders

Probe Accessories

Sensors for measuring pH,

Redox and Conductivity

must be installed in the

system using special probe

holders that ensure the

correct

mechanical

protection and degree of

impermeability.

The pH and Redox

measurement probes can

be submerged in tanks,

inserted in pipes or placed

in sample draw down

containers (Catch Pots).

The immersion models with adjustable flange can be used in conjunction with a counter-flange which allows quick and easy installation and removal. The P-IG range with a floating platform adapts to the varying liquid level of deep water tanks. The polypropylene versions PIR-2-PPxxx can house two sensors, e.g. pH and Redox. It is not recommended to use PH and/or Redox sensor in the same probe holder as a conductivity cell.

Immersion probe holder

Immersion probe holder

PI

Immersion No. of probes Max Temperature Material

PI PVC 400 400 mm
PI PVC 800 800 mm
PI PVC 1000 1000 mm
PI PVC 1500 1500 mm
PI PVC 2000 2000 mm

Code 9900100111

1

40°C

PVC

Code 9900100112

1

40°C

PVC

Code 9900100115

1

40°C

PVC

Code 9900100113

1

40°C

PVC

Code 9900100116

1

40°C

PVC

PIR PVC

Immersion No. of probes Max Temperature Material

PIR PVC 200

Code 9900100101

100÷250 mm

1

40°C

PVC

PIR PVC 400

Code 9900100102

100÷450 mm

1

40°C

PVC

PIR PVC 800

Code 9900100103

100÷850 mm

1

40°C

PVC

PIR PVC 1000 Code 9900100105

100÷1050 mm

1

40°C

PVC

PIR PVC 1500 Code 9900100106

100÷1550 mm

1

40°C

PVC

> > > 28 seko water & industry control and measuring instuments

Immersion probe holder

Immersion probe holder

PIR 2 PP

Immersion No. of probes Max Temperature Material

PIR 2 PP 400

Code 9900100121

100÷450 mm

2

80°C

PP

PIR 2 PP 800

Code 9900100122

100÷850 mm

2

80°C

PP

PIR 2 PP 1000 Code 9900100124

100÷1050 mm

2

80°C

PP

PCIR PP

Immersion

PICIR PP 400

Code 9900100141

100÷450 mm

1

80°C

PP

PICIR PP 800

Code 9900100142

100÷850 mm

1

80°C

PP

PICIR PP 1000 Code 9900100144

100÷1050 mm

1

80°C

PP

PICIR PP 1500 Code 9900100145

100÷1550 mm

1

80°C

PP

Probe holders with 3/4" probe attachment without protection
These can house conductivity probes with threaded 3/4" G. Attachment with output cable or IP67 connector.

Counter-flange
Int. Diameter Ext. Diameter Attachment Material

No. of probes Max Temperature Material
Immersion probe holder
Immersion No. of probes Max Temperature Material

PI G

PI G

Code 9900100131

Floating

1

40°C

PVC

B PI G

Code 9900100132

2m anchorage arm

-

40°C

PVC

FER

for quick removal

FER 65 mm

Code 9900100133 140 mm 40°C

4 holes Ø 6 mm

> > > innovation technology future 29

Probe Accessories

Cables, buffer solutions and probe accessories
probe holders

Probe Accessories
Immersion probe holder
Immersion No. of probes Max Temperature Max Pressure 1/h Min - Max

PIA PVC

PIA PVC 400 400 mm
PIA PVC 800 800 mm

Code 9900100151

1

40°C

Code 9900100152

1

40°C

2÷6 100÷600 2÷6 100÷600

Immersion probe holders with spray cleaning
These special probe holders can be connected with a cleaning liquid injection unit. Regular cleaning of the probe ensures linearity and stability of the measurement over time, preventing the need for timeconsuming manual intervention.

PSS 7 Single

PSS 7

PSS 7A

Tap probe holder
Immersion No. o probes Max Temperature Max Pressure

PSS 7 Single 400 mm
PSS 7 800 mm
PSS 7A 800 mm

Code 9900103021

1

40°C

6 bar

Code 9900103008

1

40°C

6 bar

Code 9900103010

1

40°C

6 bar

Tap probe holders
Tap probe holders are used for inline measurements where part of the sample is re-directed from the main pipe to the probe holder. The water can be drawn off into the sampling circuit at a pressure of 6 bars.

> > > 30 seko water & industry control and measuring instuments

Probe Accessories

Outflow probe holder

Outflow probe holders for conductivity probes
Bypass probe holder for conductivity probe model CTK1, 5 and 10 Made of black PVC with 3/4" mechanical connection and 1" GAS IN/OUT hydraulics. OUTFLOW SECTION (PSS-COND-T)
Code 0000126035

PSS 3

SPP

SPP FIL

Pressurized probe holder
Connection to the process Probes attachment Max Temperature Max Pressure Material

PSS 3 1/2" G.M.
SPP 1" G.F.
SPP FIL 3/4" or 1" 1/4 G.M.

Code 9900106670 PG 13,5 or Ø 12 mm
Code 9900100134 PG 13,5
Code 9900100135 PG 13,5

60°C

7 bar

PVC

60°C 16 bar PP + PVC

80°C 16 bar

PP

Pressurized probe holders
Pressurised probe holders are used to immerse the probe directly into the pipe where the sample to be measured passes. The probe must always be positioned vertically or slanting in the direction of the flow at a maximum of 45°. The probe holder connection line must be fitted between two isolation valves (input and output) in order to permit the prevention of the flow during maintenance of the probes.