Thank you for choosing Meaco. This manual provides essential information for operating your MeacoCool MC Series portable air conditioner. Please read it carefully before use and keep it for future reference.

The MeacoCool MC Series portable air conditioners are available in 7000BTU, 8000BTU, 9000BTU, and 10000BTU capacities, with options for Cooling Only (CO) and Cooling and Heating (CH) models.

Safety Information

This portable air conditioner must not be used in rooms with:

  • Potentially explosive atmosphere
  • Aggressive atmospheres
  • High concentration of solvents
  • Extremely high ratio of dust

Important Safety Precautions:

  • Keep children away from the unit. It is not intended for use by individuals with reduced physical, sensory, or mental capabilities unless supervised.
  • Always operate the unit with a grounded plug and a grounded electrical outlet.
  • Never operate the unit with a damaged power cord. If damaged, it must be replaced by a cord of the same type and amperage rating.
  • Use only grounded extension cords capable of delivering the appropriate voltage.
  • Handle the unit with care; do not drop, throw, or crash it.
  • Operate the unit on a stable, level surface to prevent it from falling.
  • Never operate the unit in pooled or standing water. Do not store or operate outdoors. If electrical components become wet, dry them thoroughly before use.
  • Keep air intakes clear. Do not place the unit too close to walls, curtains, or other objects that could restrict airflow, as this may cause overheating.
  • Keep electrical components dry. Never allow water inside the unit's electrical components.

Refrigerant Information:

The MeacoCool MC Series uses R290 refrigerant gas, which has a low greenhouse effect (GWP). This refrigerant is flammable.

  • The unit contains approximately 140g (7000/7000CH), 180g (8000/8000CH, 9000/9000CH), or 200g (10000/10000CH) of R290 refrigerant.
  • Do not use or store the unit in rooms smaller than 4m² to prevent fire or explosion hazards if a leak occurs.
  • Avoid rooms with ignition sources like open flames, gas fires, or cigarettes.
  • Ensure the room is adequately ventilated if the unit is operated in a non-ventilated area.
  • R290 refrigerant gas is odorless.
  • Do not puncture the unit during its working life or after disposal. Dispose of according to local recycling regulations.
  • If the unit is damaged, do not use it and contact Meaco or your retailer.
  • Always keep the unit upright and allow it to stand upright for eight hours before first use.
  • Servicing should only be carried out by a Meaco-approved engineer using original Meaco parts.

Wiring Instructions

If you need to change the plug, follow this color code:

  • Blue: Neutral
  • Brown: Live
  • Green and Yellow: Earth

Connect the wires to the corresponding terminals in the plug:

  1. Blue wire to the terminal marked 'N' or colored Black.
  2. Brown wire to the terminal marked 'L' or colored Red.
  3. Green/Yellow wire to the terminal marked 'E' or colored Green/Yellow.

Ensure the cord grip is positioned and fastened correctly. Use only the same fuse as originally fitted. If in doubt, contact Meaco or a qualified electrician.

Example wiring for a Standard British Plug: Earth Terminal marked with 'E' or Earth Symbol ⏚

Product Identification

The box contains:

  • Portable air conditioner unit
  • Duct
  • Duct machine adaptor
  • Duct window adaptor
  • Drainage hose
  • Remote control
  • Window kit (for sash windows and sliding doors)

Replacement parts can be purchased at www.meaco.com. For different window kit types, visit the website or call 01483 234900.

Key Components:

  • Control Panel: Located on the top of the unit.
  • Handle: For easy portability.
  • Air Outlet: Where cooled air is expelled.
  • Air Inlet: Where room air is drawn in.
  • Air Exhaust: Where hot air is expelled through the duct.
  • Drain opening with sealing plug: For draining collected water.

Included Accessories:

  • Duct
  • Duct Machine Adaptor
  • Duct Window Adaptor
  • Remote Control
  • Drainage Hose
  • Window Kit

General Advice

  • Study the instruction manual carefully before first use.
  • Check the unit for any transport damage upon receipt and inform the sender immediately if damage is found.
  • Allow the unit to stand upright for eight hours before turning it on.
  • Place the unit on a level surface with at least 50cm of free space around it for adequate airflow.
  • Do not operate the unit near walls, curtains, or other objects that may block the air outlet or inlet.
  • Keep the original packaging for potential service or returns.

Portable Air Conditioner Principles

For optimal cooling, use the unit in a well-sealed room with minimal heat gain from sunlight. Close doors, windows, and curtains/blinds before operation to pre-cool the room.

Set Up

The portable air conditioner requires venting to the outside via a window. The provided duct is 1.8 meters long and cannot be extended. A maximum length duct of 2 meters is available for purchase.

These steps are not required for Dry, Fan, or Heat modes.

  1. Connect duct to machine adaptor: Twist the duct machine adaptor onto the duct.
  2. Connect duct to window adaptor: Twist the duct window adaptor onto the other end of the duct.
  3. Attach duct to window kit: Use the duct window adaptor to connect the duct to the window kit. Insert Plate A into Plate B, adjust to window height, and install the duct into section B.
  4. Secure window kit: Close the window to secure the kit. Seal any gaps for maximum efficiency.
  5. Attach duct to unit: Connect the duct to the air exhaust on the portable air conditioner using the duct machine adaptor.
  6. Extend duct: Ensure the duct is extended to the desired length without bends or kinks.
  7. Adjust louvre: Manually open the front louvre and adjust internal louvres to direct airflow.
  8. Connect drainage hose (if needed): For Dry or Heat Mode, connect the drainage hose (see page 15).
  9. Power on: Plug the unit into a mains socket and turn it on using the Power Button.

Control Panel

The control panel features buttons for Power, Mode, Up/Down temperature/timer settings, Timer, and Fan Speed.

  • Power Button: Turns the unit on/off. The unit defaults to Fan Mode with a 3-minute compressor delay when turned on.
  • Mode Button: Cycles through Cool, Dry, Fan, and Heat (CH models only) modes.
  • Up and Down Buttons: Adjust temperature or timer settings.
  • Timer Button: Sets an On or Off timer (1-24 hours).
  • Fan Speed Button: Selects High or Low fan speed (disabled in Dry and Sleep modes).

Note: The Heat LED only displays on CH models. Sleep Mode is available via the remote control.

The Modes

Cool Mode

  1. Select 'Cool' mode.
  2. Set desired temperature (16°C - 32°C) using Up/Down buttons. The unit will run until the temperature is reached and cycle as needed.
  3. Select fan speed (High/Low).
  4. Adjust airflow direction horizontally using the inner louvre.

Dry Mode

Select 'Dry' mode. The fan runs continuously. Compressor operation varies based on ambient temperature:

  • > 25°C: Compressor runs for 15 mins, stops for 3 mins.
  • 20°C - 25°C: Compressor runs for 10 mins, stops for 3 mins.
  • 15°C - 20°C: Compressor runs for 6 mins, stops for 3 mins.
  • < 15°C: Compressor stops; unit resumes when temperature reaches 17°C.

Fan speed is automatically set to Low. Temperature cannot be selected. Attach the drainage hose for continuous operation.

Fan Mode

  1. Select 'Fan' mode.
  2. Select fan speed (High/Low).
  3. Temperature cannot be selected. The unit circulates air but does not cool.
  4. Adjust airflow direction horizontally using the inner louvre.

Heat Mode (CH models only)

  1. Select 'Heat' mode.
  2. Set desired temperature (16°C - 32°C) using Up/Down buttons.
  3. Select fan speed (High/Low).
  4. Adjust airflow direction horizontally using the inner louvre.
  5. Attach the drainage hose for continuous operation.

Sleep Mode (Remote control only)

Activated in Cool or Heat mode. Runs on Low Fan Speed. In Cool Mode, the temperature increases by 1°C each hour for the first two hours, then remains constant for 10 hours. The display dims.

Other Functions

The Timer

Set an Off Timer (when the unit is on) or an On Timer (when the unit is off) for 1-24 hours using the Timer and Up/Down buttons. Timers are reset when the power is turned off.

Automatic Defrost

Frost may build up at low temperatures. The unit will automatically defrost. The LED above the Power Button will flash. In Cool or Dry mode, if the evaporator coil temperature drops below -1°C, the compressor will stop for 10 minutes or until the coil temperature reaches 7°C. The unit will then restart in Cool Mode. This is a normal process.

Overload Protection

The unit has a memory function. After a power cut, it will resume its previous setting after a three-minute delay to protect the compressor.

Remote Control

The remote control allows operation of all functions, including fan speed, modes (Cool, Dry, Fan, Heat), Sleep Mode, and timer settings. It also allows switching between °C and °F.

Drainage

In Dry and Heat modes, the drainage hose must be attached continuously to remove collected water. In Cool mode, the hose may be needed for high humidity or after prolonged use. The display will show 'Ft' (Full Tank) when the water tank needs draining.

To drain the unit:

  1. Unplug the unit.
  2. Slightly raise the unit to drain water via gravity.
  3. Remove the water outlet plug (do not lose it).
  4. Securely attach the drainage hose to the outlet.
  5. Place the hose end over a drain or bucket, ensuring free flow.
  6. Do not submerge the hose end in water to avoid air locks.
  7. Once drained, remove the hose and reinsert the plug.

Cleaning and Storage

Clean air filters at least once every two weeks to maintain airflow and efficiency. Do not operate without filters.

  1. Unplug the unit.
  2. Remove filters (top and bottom).
  3. Clean filters using a vacuum cleaner or warm water. Allow to air dry completely before reinstalling.

Before moving or storing, drain any collected water. Use the cable compartment for the mains cable. Store the unit in its bag or original box to protect it from dust.

The unit can also be used as a dehumidifier (above 15°C) and a heater during winter.

Specifications

Specification 7000 / 7000CH 8000 / 8000CH 9000 / 9000CH 10000 / 10000CH
Cooling Capacity 7000BTU 8000BTU 9000BTU 10000BTU
Power Consumption 780 watts 1003 watts 1003 watts 1114 watts
Heating Capacity (CH models only) 5800BTU 7000BTU 7000BTU 7800BTU
Noise Level (on low fan speed) 53dB 53dB 53dB 53dB
Energy Rating A A A A
Maximum airflow 300m³/hour 325m³/hour 325m³/hour 325m³/hour
Approx. Room Size 12-22m² 16-26m² 16-26m² 18-28m²
Duct Diameter 15cm / 5.9" 15cm / 5.9" 15cm / 5.9" 15cm / 5.9"
Duct Length 1.8m / 71" 1.8m / 71" 1.8m / 71" 1.8m / 71"
Moisture Removal 0.8 litres / hour 1.2 litres / hour 1.2 litres / hour 1.4 litres / hour
Current (nominal) 3.5A 4.5A 4.5A 5A
Off Timer Yes Yes Yes Yes
On Timer Yes Yes Yes Yes
Power Supply 220-240V / 50Hz 220-240V / 50Hz 220-240V / 50Hz 220-240V / 50Hz
Refrigerant R290 / 140g R290 / 180g R290 / 180g R290 / 200g
Dimensions (HWD) 701 x 350 x 348mm 701 x 350 x 348mm 701 x 350 x 348mm 701 x 350 x 348mm
Nett Weight 20.5Kgs / 21Kgs 23.5Kgs / 24Kgs 23.5Kgs / 24Kgs 24Kgs / 24.5Kgs
Gross Weight 25.5Kgs / 26Kgs 28.5Kgs / 29Kgs 28.5Kgs / 29Kgs 29Kgs / 29.5Kgs

Trouble Shooting

Trouble Cause Solution
No power to the machine There is no power to the unit. The ON/OFF button has not been pressed. Plug in the unit and check the power outlet. Press the ON/OFF button.
Power button does not work Check the instructions above. If it still does not work, please contact Meaco.
Machine turned on but compressor does not work The compressor does not turn on for the first three minutes of operation. Wait three minutes.
Remote control does not work The battery needs changing or the remote is out of range. Replace the battery in the remote or stand closer to the machine.
Increased noise level The filter is dirty. The air inlet is blocked. The unit is being used on an uneven floor. Clean the filter (see page 16). Make sure there is enough space around the unit and that the air inlet is not blocked. Place the unit on a level surface.
Too noisy to use in a bedroom Pre-cool the room. Run the unit for several hours before bed with curtains and door closed.
Fan speed does not change The unit is in Sleep Mode or Dehum Mode. Change operation mode (see pages 11 and 12).
Cooling is not effective Room size is too large. Too much direct sunlight. Unit has not been running long enough. Filter is blocked or dirty. Check if the air coming out is cool. Use in a smaller room, keep doors/windows shut. Block heat gain from sun. Allow time to cool. Clean filter and ensure adequate airflow.
Heating is not effective Room size is too large. Check if the air coming out is warm.
Machine turns itself off The set point has been reached. Accept the set point or select a new one.
Machine leaks water when moved Internal water container is full. Always drain the unit before moving it (see page 15).
Display shows 'Ft' Internal water container is full. Please see page 15.
E0 Display board error. Please contact Meaco.
E1 Temperature sensor is faulty. Please contact Meaco.
E2 Evaporator coil sensor is faulty. Please contact Meaco.

Contact Meaco:

Warranty

A two-year manufacturer's warranty is provided from the date of purchase. Register your purchase at https://meaco.com/warranty-register to be entered into a monthly prize draw and receive product updates.

The warranty covers manufacturing defects, excluding wear and tear items like filters, ducts, adaptors, hoses, remote controls, and window kits.

Warranty Conditions:

  • Repairs or replacements do not extend the warranty period.
  • Warranty is void if alterations are made, non-genuine parts are used, or repairs are done by a third party.
  • Components subject to normal wear and tear are not covered.
  • Warranty is valid with the original, unaltered, date-stamped receipt.
  • Damage caused by misuse, neglect, dirt, or third-party products is not covered.
  • Accidental damage and consequential damages are not covered.

Always read the user manual first to resolve issues. Contact Meaco if problems persist.

Import Information:

This portable air conditioner has been imported into the UK by: Meaco (UK) Limited, Meaco House, Parklands, Railton Road, Guildford, GU2 9JX. Telephone: 01483 234900. Email: service@meaco.com. Website: www.meaco.com.

Please record your date and place of purchase for future reference.

Keep the original box and packaging for potential service or repair needs.

Disposal Information

This marking indicates that the product should not be disposed of with other household wastes. Recycle responsibly to promote the sustainable reuse of material resources. Return your used device through collection systems or contact the retailer where it was purchased for environmental safe recycling.

CE marking is present.

PDF preview unavailable. Download the PDF instead.

MeacoCool-MC-Series-Portable-Air-Conditioner-7000-10000BTU-Instruction-Manual-2020-English macOS Versjon 10.15.4 (bygg 19E287) Quartz PDFContext Forhåndsvisning

Related Documents

Preview MeacoCool Pro Series Air Conditioner: Instruction Manual & User Guide
Comprehensive instruction manual for the MeacoCool Pro Series air conditioners (7000-10,000 BTU). Covers safety, installation, operation, maintenance, troubleshooting, specifications, and warranty.
Preview Meaco 25L Ultra Low Energy Dehumidifier: Instruction Manual & Guide
Comprehensive instruction manual for the Meaco 25L Ultra Low Energy Dehumidifier. Learn about safety, operation, maintenance, troubleshooting, and specifications for optimal performance.
Preview Meaco Armin 300 Evaporative Humidifier Instruction Manual
This instruction manual provides comprehensive guidance for the Meaco Armin 300 evaporative humidifier, covering setup, operation, maintenance, troubleshooting, and warranty information. Learn how to use and care for your humidifier for optimal performance.
Preview MeacoFan Sefte 8" Portable Table Air Circulator Instruction Manual
Instruction manual for the MeacoFan Sefte 8" Portable Table Air Circulator, covering safety information, product identification, operation, battery mode, maintenance, troubleshooting, customer care, specifications, and warranty terms.
Preview MeacoDry Arete Two Dehumidifier and Air Circulator Instruction Manual
Comprehensive instruction manual for the MeacoDry Arete Two dehumidifier and air circulator, detailing setup, operation, maintenance, troubleshooting, and warranty information. Learn to optimize your home's humidity and air quality.
Preview Meaco Sefte 10" Pedestal Air Circulator Instruction Manual
Comprehensive instruction manual for the Meaco Sefte 10" Pedestal Air Circulator. Learn about safety, assembly, operation, maintenance, and troubleshooting for your air circulator.
Preview MeacoFan 260c Cordless Air Circulator Instruction Manual
This document provides comprehensive instructions for the MeacoFan 260c Cordless Air Circulator, including safety guidelines, setup, operation, charging, cleaning, battery replacement, technical specifications, and troubleshooting.
Preview MeacoFan 650 Air Circulator: Instruction Manual and User Guide
Comprehensive instruction manual for the MeacoFan 650 Air Circulator. Learn about safety, operation, maintenance, specifications, and troubleshooting for your Meaco fan.