Owner's Manual for POTTER models including: UD-1000 Digital Alarm Communicator, UD-1000, Digital Alarm Communicator, Alarm Communicator, Communicator

Click here to download

Potter UD-1000 PFC Series Digital Alarm Communicator Transmitter - Fire Alarm Resources - Free fire alarm PDF manuals, documents, installation instructions, and technical specifications


File Info : application/pdf, 2 Pages, 1.36MB

PDF preview unavailable. Download the PDF instead.

?tmstv=1676759277
Features
· allows for communication to Monitoring Station · Communicates using SIa-DCS or ademco Contact ID protocols · For use with 6000 series and p series addressable panels · Status LEDs indicate operation of DaCT card · Installs with ease behind main panel LCD display via User Interface
bracket
· Device address is set by dipswitches located on DaCT card · Installation materials including 4 pin connector and screw are supplied
with DaCT card
· UUKL Listed with Smoke Control

UD-1000
Digital Alarm Communicator

Description
The UD-1000 Digital alarm Communicator Transmitter (DaCT) provides for up to two (2) phone lines for communication to a monitoring station. The UD-1000 communicates using the SIaDCS or ademco Contact ID protocols. When enabled, the DaCT automatically monitors each phone line or voltage and has the ability to seize the line and connect with a remote receiver. Once the communication is complete, the DaCT will hang up.
The DaCT is provided with an RJ-11 jack for each phone line and a RJ-11 to RJ-33 cord. In order for the DaCT to work properly, it must be installed on a plain old telephone service (pOTS) line or equivalent deemed by the authority having jurisdiction. The DaCT must be installed before any other equipment to ensure it can seize the phone line.
phone lines are high voltage and should be run in a separate conduit from other circuits. The wire conductors connecting the DaCT to the phone system should be 26 aWg or larger.

S735 7165-0328:0195

Technical Specifications

Operating Voltage Standby Current alarm Current Max UD-1000s per panel Dimensions Operating Tempuratures
Operating Humidity Range
Mounting Options Shipping Weight

22.0-24.0V 16ma 23ma 1
4"W * 6"H * 1-5/8"D 0°C - 49°C (32°F- 120°F) 10% - 93% @ 30°C (86°F)
(non-condensing) In FaCp Behind keypad
0.47 lbs

potter Electric Signal Company, LLC · St. Louis, MO · Tech Support: 866-956-1211 / Customer Service: 866-572-3005 · www.pottersignal.com

8830048 - REV B · 12/18

pagE 1 OF 2

firealarmresources.com

UD-1000 DACT Installation on
PFC-6030/6075R
Fig 1

UD-1000
Digital Alarm Communicator
UD-1000 DACT Installation on PFC-6800/6200
Fig 2

Screw

UD-1000 DACT Slides in guides under main board. DWG #593-32A

p Connector on pFC-6075 main board

Screw

UD-1000 DA

Install in accordance with compatible fire alarm control panel installation manual

p Connector on pFC-6800 main board

Installation
The UD-1000 DaCT is connected to the control panel using the provided four-wire cable connection (p/N 5210514) between p4 and UD-1000 p1. The connection is power limited and supervised. 1. power system down. 2. Slide the UD-1000 into the card guides located under the User Interface bracket. 3. Secure the UD-1000 to the User Interface bracket using the provided #6-32x3/8" screw 4. Install the provided four-wire conductor jumper between UD-1000 p1 and p4.

potter Electric Signal Company, LLC · St. Louis, MO · Tech Support: 866-956-1211 / Customer Service: 866-572-3005 · www.pottersignal.com

8830048 - REV B · 12/18

pagE 2 OF 2