Instruction Manual for BLINKCAST models including: Flexion 6 Led Single Colour Lighthead, Flexion, 6 Led Single Colour Lighthead, Single Colour Lighthead, Colour Lighthead, Lighthead

Cell2 FLEXION UserManual Single

Flexion, Module, Warning Light, Flexible, Bend, Mounting, Amber, Blue, Red, LEDs, Light, Lights, EMS, Emergency, Safety, Auto, Automotive

Cell2 FLEXION UserManual Single EN

FX6 - Blue (12~24VDC) - Cell2

PDF preview unavailable. Download the PDF instead.

Cell2 FLEXION UserManual Single EN
86-M08910-0001.0

SINGLE
COLOUR

6 LED SINGLE COLOUR LIGHTHEAD

Wiring
To Chassis Ground:........................................... BLACK
To+VDC for Warning Mode (fuse @ 1A):.............. RED
Default Flash Pattern - FP#2 Single [2Hz]
To+VDC for Warning Mode (fuse @ 1A):......... WHITE
Default Flash Pattern - FP#1 Double [2Hz]
To+VDC for Warning Mode:.................RED+WHITE
Default Flash Pattern - FP#18 Steady Scene
For Synchronization and Flash Pattern:........YELLOW
Connect YELLOW wire of all lightheads together for synchronization. (All lightheads should be set to the same Flash Pattern)

117.4mm (4.62" )

Operation

For Flash Pattern Selection:
Each Warning Mode may select and save one Flash Pattern. While activating a Warning Mode, momentarily apply YELLOW wire to +VDC:
· Once to the next pattern. · Quick three times to FP#1 (refer to Flash Pattern Chart)

Flash Pattern (Single Colour)

1 Double

[2Hz]

2 Single

[2Hz]

3 Triple

[2Hz]

Shortcut Setting for Steady EF (External flasher):

4

This shortcut allows quick changing of trigger wires setting to each colour with Steady EF pattern all at 5

one time. Momentarily apply YELLOW wire to +VDC for 3~4 seconds (visual feedback: ONOFF ON) while activating any warning mode. Colour mode and Flash Pattern of each warning mode will be

6

set to:

7

Warning Mode 1 = Colour 1, FP#6 Steady EF

8

Warning Mode 2 = Same Colour mode, FP#21 OFF

Warning Mode 3 = Same Colour mode, FP#21 OFF

9

10

Setting Mode

11

Quad Random Steady EF* Single Double Triple Quad Quint

[2Hz]
[SAE][CA13] [SAE] [SAE] [SAE] [SAE]

The following settings will require user to enter SETTING MODE to operate; to enter:

12 Mega

1. Power off the unit completely and power up by applying +VDC to RED (or WHITE or RED+WHITE) and YELLOW wires simultaneously.

13

Giga

2. Remove YELLOW wire from +VDC to enter SETTING MODE. Lighthead will then flash in

14 Ultra

[SAE]

low-power while in SETTING MODE. 3. To save and exit the setting, simply disconnect the power after operation.

15 Single-Quad

16 Singe H/L

For Simultaneous or Alternating Synchronization:
To change Group, while in setting mode, momentarily apply YELLOW wire to +VDC for 3~4 seconds. 17 Single-Triple-Quint

the lighthead will display short flashes:

18 Steady Scene

· Single flash

· Three flash

Set by BlinkCast Programmer only.

· Five flash

· Seven flash

Simultaneously
= Group 1 = Group 2 = Group 4 = Group 7

Alternately

· Double flash = Group 5

· Four flash = Group 3

· Six flash

= Group 6

· Eight flash = Group 8

NOTE: · Lightheads of the same Group will flash together. · Lightheads of the Group 1 & Group 5 will flash alternately.

19 Cruise 20 Sweep Single TA 21 OFF
* For use with external flash controller.

Reset to Factory Default Settings:
While in setting mode, apply YELLOW wire to +VDC for more than 5 seconds. The lighthead will display fast short flashes to signify restoring successfully.

BlinkCast Ready
This product can be configured ideally by using BlinkCast Programmer with desired Flash Pattern, Group (Phase), and Colour Mode to save your installation time! Contact your sales representatives or see your User Manual of BlinkCast Programmer for detailed information.

SINGLE
COLOUR

6 LED SINGLE COLOUR LIGHTHEAD

Installation

Curved Surface / Flat Surface

1. [Curved Surface] Use curvature template to check surface mountability: make sure surface curvature is over 120 degree.

Both points can touch: mountable Curvature Template

One or no point can touch: unmountable Curvature Template

Mounting Surface

Mounting Surface

2. Mark and drill a wire passage hole on the mounting surface. Make sure no vehicle parts could be damaged by the drilling process. (Thoroughly deburr hole and use grommet for wire passage hole if needed)
3. Clean and dry the mounting surface with alcohol prep pad provided. (or 50:50 mix of isopropyl alcohol and water)
4. Remove the tape liner from the tape and apply the lighthead to the surface and press it firmly for 30 seconds. Full adhesion and bonding will be achieved after 72 hours at room temperature.
5. [Flat Surface] For best secure installation, it is recommended to always mount lightheads with screws. [Curved Surface] Due to lighthead tension, it is required to always mount lightheads with screws on curved surface.
6. Once secured, apply screw covers onto the lighthead for best aesthetic. (use silicon glue to better scure the screw cover)

Prohibition

Tape liner

Ø3.5mm (0.135in) Screw washer Ø3x12mm Sheet metal screw Screw covers

No Pulling

No Warping

No Bending Inwards

Mounting Dimensions

117.4mm(4.62")

No bending over 120°

Curvature Template
1:1 template

Ø15mm(0.59")

1:1 template

120° Max.
CUT

CUT

