Instruction Manual for elero models including: 28 120.0001 VarioTec Central Control Unit, 28 120.0001 VarioTec, Central Control Unit, Control Unit, Unit

VarioTec 28 120 - elero

Nr. 18100.3401/0204 Operating instructions (translation) Please keep these instructions in a safe place! EN VarioTec 28 120.0001

[PDF] Operating instructions (translation) VarioTec 28 120.0001

You can find the structure of a controller on elero.com in the download area unter „Installation instructions and circuit dia- gramms“. 1. Remove the protective ...


File Info : application/pdf, 9 Pages, 510.69KB

PDF preview unavailable. Download the PDF instead.

VarioTec - Operating instruction - Hardwired control units
VarioTec 28 120.0001
EN Operating instructions (translation)
Please keep these instructions in a safe place!
Nr. 18 100.3401/0204

Contents
Safety instructions ......................................................................2 Explanation of displays and buttons ........................................3 General information ....................................................................4 Designated use............................................................................4 Installation/Connection VarioTec ...............................................5
Connection as a drive controller .............................................5 Connection as a group controller............................................6 Factory settings...........................................................................7 Explanation of functions Manual/Automatic sliding switch, Alarm signal control light.........................................................7 Buttons ....................................................................................8 Group control ..........................................................................8 Intermediate position, Ventilation/reverse position .................8 Drive controller, Group controller............................................9 Selecting roller shutter/awning or venetian blind mode .......................................................................................9 Function menu.............................................................................9 Manual operation functions.....................................................9 Automatic operation functions.................................................9 Programming menu ..................................................................10 Programming intermediate position ......................................10 Programming ventilation/reverse position.............................10 Adjustment to intermediate position......................................11 Adjustment to ventilation position .........................................11 Adjustment to reverse position .............................................11 Deleting intermediate position...............................................11 Deleting ventilation/reverse position .....................................11 Technical data ...........................................................................12 Cleaning .....................................................................................12 Troubleshooting ........................................................................12 General declaration of conformity...........................................12
2 | EN

Safety instructions
Important safety instructions! Always observe the following instructions. Warning! Risk of injury by electric shock.
· All terminal connections to a 230 V network must be made by an authorised electrician.
· Before assembly, always disconnect the mains lead from the power supply.
· The provisions of the local public utilities and stipulations for wet and damp rooms in accordance with VDE 100 must be observed during system installation.
· For use in dry rooms only. · Use unmodified elero original parts only. · Keep persons away from the systems guide track. · Keep children away from controls. · Always comply with national stipulations. · If the system is controlled by one or more
devices, the system guide track must be visible during operation. · Only cables with sufficient electric strength may be used to connect control cables (protective low voltages). · The equipment contains small parts that could be swallowed.
EN | 3

Explanation of displays and buttons

Explanation of displays

Manual/Automatic sliding switch

Alarm signal

Auto

control light

Cover

UP button STOP button DOWN button

Buttons under the cover

Reset button

VarioTec

POS button

POS button

Encoding switch (located on back of device)

2Q  
1 23

1 Upper position Lower position
2 Upper position Lower position
3 Upper position Lower position

 Alarm signal function OFF.  Alarm signal function ON.
 Group controller  Driver controller
 Venetian blind mode  Roller shutter/
awning mode

4 | EN

General information / Designated use
General information The VarioTec device operates your roller shutters/sun protection systems on the basis of manual or external control commands. The VarioTec device can be operated manually at all times. The VarioTec is characterised by its user-friendly operation. Designated use The VarioTec may be used to operate roller shutters/sun protection systems only. This device may only be used in connection with equipment from other manufacturers following consultation with your local retailer.
EN | 5

Installation / Connection
Installation

Note: The encoding switch located on the back of the VarioTec device can be used to select group or drive control.

Connection as a drive controller

For details on suitable control systems, please refer to the control product catalogue.

Warning!

Risk of injury by electric shock! · Terminal connections must be carried out by an autho-
rised electrician! · If more than one drive is operated using the VarioTec,
the drives must be decoupled by relay controls. · The switched current of the device must be observed
at all times!

1. Remove the protective caps.

2. Connect.

M 1~
Mains 230 V/50 Hz
PE N L

NL

C

VarioTec
Individual Central
12 3 4 5 6 Venetian blind
pushbutton

Note:
Always use a shielded control wire . . . 0.8 mm or JY-ST telephone line . . . 0.6 mm.

6 | EN

To other control devices

Installation

3. Replace the protective caps on the power supply unit. 4. Secure the power supply unit in the box. 5. Insert the operating device into the frame and plug it into
the power supply unit.
Connection as a group controller You can find the structure of a controller on elero.com in the download area unter ,,Installation instructions and circuit diagramms".

Warning!

Risk of injury by electric shock!
· Terminal connections must be carried out by an authorised electrician!

1. Remove the protective caps. 2. Connect.

Mains

L

230 V/50 Hz N

NL

C

VarioTec
Individual Central

1234 56
Venetian blind pushbutton

Output Input

Note:
Always use a shielded control wire . . . 0.8 mm or JY-ST telephone line . . . 0.6 mm.

To other control devices

To other control devices

3. Replace the protective caps on the power supply unit.
4. Secure the power supply unit in the box.
5. Insert the operating device into the frame and plug it into the power supply unit.

EN | 7

Explanation of functions

Factory settings Encoding switch factory setting

1. Lower position 2. Lower position 3. Lower position

Alarm signal function ON. Driver controller. Roller shutter/awning mode.

Explanation of functions
Manual/Automatic sliding switch In the "MANUAL " mode, only manual control commands and alarm signals are executed (e.g.: by pressing UP, STOP, DOWN buttons and alarm button). When the sliding switch is set to "AUTO", automatic control commands are carried out (e.g. control signals via group control inputs.).
Alarm signal control light An alarm signal is a continuous switching signal at the group or individual control inputs which lasts for more than 5 seconds.
If the alarm signal control light is illuminated, this indicates an alarm signal. The encoding switch 1 can be used to switch the alarm signal function on or off.

8 | EN

Explanation of functions
Reset button: Press the Reset button (with a ballpoint pen or similar object) to delete the intermediate position and the ventilation/reverse position.
POS : The Pos  button can be used to programme an intermediate position.
POS : The Pos  button can be used to programme a ventilation/reverse position.
Group control: Group control refers to the simultaneous operation of several drives.
Intermediate position: The intermediate position lies between the upper and lower limits of the roller shutters/sun protection system and can be freely selected. The roller shutters/sun protection system can be moved into this position from the upper end limit after programming. To do so, press the DOWN button twice in quick succession. When the system is in venetian blind mode, it is also possible to programme a reverse position. In this case, this command will be automatically executed following the intermediate position command.
Ventilation/reverse: The ventilation/reverse position lies between the upper and lower limits of the roller shutters/sun protection system and can be freely selected. Your roller shutters can be moved into this position from the lower end limit until the ventilation slats are open. In venetian blind mode, the blind slats are turned. To do so, press the UP button twice in quick succession.
EN | 9

Function menu/Explanation of functions
Drive controller: If the VarioTec device is being used as a drive controller, the drive is directly connected to the VarioTec device, in which case external signals are converted into control commands. Encoding switch 2 must be set to the lower position.
Group controller: If the VarioTec device is being used as a group controller, additional group and drive control devices can be connected. Encoding switch 2 must be set to the upper position.
Selecting roller shutter/awning or venetian blind: Encoding switch 3 is used to select roller shutter/awning mode (lower position) or venetian blind mode. In venetian blind mode, the blind moves in non-maintained command mode to ensure that the slats are positioned accurately. Press and hold any control button for more than 1 second to operate the venetian blind in maintained command mode.
Functions Manual operation functions · UP, STOP, DOWN · Adjustment to intermediate position · Adjustment to ventilation/reverse position · Alarm signals
Automatic operation functions In automatic mode, both manual and external control commands are executed: · External automatic control commands · UP, STOP, DOWN · Adjustment to intermediate position · Adjustment to ventilation/reverse position · Alarm signals
10 | EN

Programming menu
Programming
Programming the intermediate position
Prerequisite: The shutter/curtain/blind is in the upper end limit position.
1. Press and hold the Pos  programming button. 2. Keeping this button pressed, then press the DOWN button
until the desired intermediate position has been reached. Use the UP or DOWN button to make any necessary adjustments. 3. Release the Pos  the programming button. The intermediate position is now stored. The control light will flash 3 times briefly.
Programming the ventilation/reverse position
Prerequisite: The shutter/curtain/blind is in the lower end limit position.
1. Press and hold the Pos  programming button. 2. Keeping this button pressed, then press the UP button until
the desired ventilation/reverse position has been reached. Use the UP or DOWN button to make any necessary adjustments. 3. Release the Pos  programming button. The ventilation/ reverse position is now stored. The control light will flash 3 times briefly
EN | 11

Programming
Adjustment to intermediate position The shutter/curtain/blind can only be moved into the intermediate position from the upper end limit position. 1. Press the DOWN button twice in quick succession.
The shutter/curtain/blind is adjusted into the stored intermediate position.
Adjustment to ventilation position (roller shutters) Roller shutters can only be moved into the ventilation position from the lower end limit position. 1. Press the UP button twice in quick succession. The shutters
are adjusted into the stored ventilation position.
Adjustment to reverse position (venetian blinds) The venetian blind slats must be closed before the blind can be adjusted into the reverse position. 1. Press UP button twice in quick succession.
The venetian blind is adjusted into the stored reverse position. When the blind reaches the stored intermediate position the blind slats are turned automatically (provided a reverse position has been pre-programmed).
Deleting intermediate position 1. Press and hold the Pos  programming button for more than
5 seconds. The intermediate position is now deleted. The control light will flash 3 times briefly.
Deleting ventilation/reverse position Press and hold the Pos  programming button for more than 5 seconds. The ventilation/reverse position is now deleted. The control light will flash 3 times briefly.
12 | EN

Technical data / Cleaning / Troubleshooting

Technical data

Nominal voltage

230-240 V AC / 50-60 Hz

Switched current

5 A /250 V AC for cos j = 1

System of protection

IP 20

Protection class

II

The protection class II is guaranteed only after a correct

installation.

Permissible ambient temperature 0 to +55 °C

Type of installation

Concealed: Ø 58 mm wallmounted Exposed: in appropriate
exposed casing

Cleaning

Clean the device with a damp cloth only. Do not use a cleansing agent as doing so may damage the plastic.

Troubleshooting

Problem

Cause

Remedy

Drive is not functioning. Faulty connection.

Check connection.

Drive moves in the wrong direction.

Faulty connection.

Exchange  and  wires in the power
supply unit.

VarioTec does not carry out external control commands.

1. Device is set to

1. Set the device to

"MANUAL " mode. "AUTO" mode.

2. Alarm signal is active.2. Wait until alarm

signal disappears

or rectify problem

causing signal.

General declaration of conformity:
The company elero GmbH hereby declares that the VarioTec device complies with the basic requirements and other relevant regulations of the EC Directive 2014/35/EU.

EN | 13

EC Declaration of conformity
Declaration of conformity elero GmbH hereby declares that the radio system type VarioTec is in compliance with directive 2014/53/EU. The complete text of the EU declaration of conformity is available at the follo-wing adress: www.elero.com/downloads/

14 | EN

EN | 15

elero GmbH Antriebstechnik Maybachstr. 30 73278 Schlierbach info@elero.de www.elero.com

309023



References