User Manual for Labco SCIENTIFIC models including: SALT20 Pocket Salinity Tester, SALT20, Pocket Salinity Tester, Salinity Tester, Tester
User Manuals
File Info : application/pdf, 8 Pages, 1.11MB
DocumentDocumentSALT20 POCKET SALINITY TESTER USER MANUAL sales@labcoscientific.com.au labcoscientific.com.au 1800 052 226 PO Box 5816, Brendale, QLD 4500 ABN 57 622 896 593 Version 1.1 CONTENTS BATTERY INSTALLATION KEYPAD FUNCTIONS COMPLETE KIT CALIBRATION SALINITY MEASUREMENT NOTES PARAMETER SETTING TECHNICAL SPECIFICATIONS OTHER FUNCTIONS & PARAMETERS WARRANTY PAGE NUMBER 2 2 3 3 3 4 4 5 5 6 1 1. BATTERY INSTALLATION Please install batteries according to the following steps. Please note polarity: "+" (anode) is upward; "-" (cathode) is downward. Note: This salinity meter measures practical salinity converted from electrical conductivity (NaCl Concentration). It does not measure absolute salinity. 2. KEYPAD FUNCTIONS Short press < 2 seconds Long press > 2 seconds 1. Short press to turn on, long press to turn off; 2. When turned off, long press to enter setup; 3. In mode setting, short press to change parameter; 1. When turned on, long press to enter calibration mode. 2. In calibration mode, short press to confirm calibration; 3. In mode setting, short press to confirm parameter selection. Diagram - 1 2 3. COMPLETE KIT Diagram 2 4. CALIBRATION 4.1 Rinse the probe in distilled water and dry it. Short press to turn on the tester. 4.2 Long press to enter calibration mode; Short press to exit. 4.3 Dip the probe into the calibration solution. Stir gently, leave it to stand, LCD displays , short press to complete 1-point calibration. The tester returns to measuring mode, and calibration icon appears at the button left of LCD. 5. SALINITY MEASUREMENT 5.1 Short press to turn on tester. Rinse probe in distilled water and dry it. 5.2 Stir probe in the sample solution gently, leave it to stand. Get readings after the smile icon comes up and stays. 3 6. NOTES 6.1 The tester has self-diagnosis functions: 6.2 The tester has already been calibrated after manufacture. Usually users can use the tester right out of the box or test it in the calibration solution to compare the reading with the standard value. When the error is large, calibrate it before using 7. PARAMETER SETTING 7.1 Parameter setting reference chart: SYMBOL PARAMETER SETTING CONTENT P1 Select salinity unit P2 Restore to factory default CODE Ppt mg/L No - Yes FACTORY DEFAULT ppt No 7.2 How to Setup parameters: When turned off, long press to enter setup short press to switch P1-P2 Short press , parameter flickering short press to choose, short press to confirm parameter selection Long press to switch off. 7.3 Parameter setting notes: a) Select salinity unit(P1): Optional units: ppt mg/L, factory default is ppt. b) Restore to factory default: Select Yes to restore the calibration to the theoretical values and parameter setting to original values. When meter's calibration or measurement performs abnormally, this function can be adopted so the meter goes back to factory default setting and then users can conduct calibration or take measurements again. 4 8. TECHNICAL SPECIFICATIONS SALINITY TEMP. RANGE RESOLUTION ACCURACY CALIBRATION POINTS AUTOMATIC TEMP. COMPENSATION RANGE RESOLUTION ACCURACY 0 10.00 ppt 0.1 ppt ± 1%F.S 1 point auto. Calibration 0 50°C 0 50°C 0.1°C ±0.5°C 9. OTHER FUNCTIONS & PARAMETERS CALIBRATED POINTS INDICATION OF STABLE MEASUREMENTS SELF-DIAGNOSIS INFORMATION LOW POWER REMINDER DIMENSION/WEIGHT AUTO POWER-OFF WATERPROOF LEVEL Power-off in 8 minutes if no operation IP67, floats on water Er1, Er2 POWER SUPPLY AAA Batteries x4 Flashes to remind to replace batteries BATTERY LIFE 1,000 Hours Instrument: 40x31x178mm/107g; Carrying Case: 190x165x140mm/438g 5 10. WARRANTY We warrant this instrument to be free from defects in material and workmanship and agrees to repair or replace free of charge, at option of APERA INSTRUMENTS, LLC, any malfunctioned or damaged product attributable to responsibility of APERA INSTRUMENTS, LLC for a period of two years from the delivery (a six-month limited warranty applies to probes). This warranty does not apply to defects resulting from actions such as misuse (violation of the instructions in this manual or operations in the manner not specified in this manual), improper maintenance, and unauthorized repairs. Warranty period is the time limit to provide free service for the products purchased by customers, not the service life of the tester or probe. 6 beyond our reasonable control. 7