Instructions for ARROW models including: CDC-22702-XP1 Pressure Injectable Arrowg, CDC-22702-XP1, Pressure Injectable Arrowg
CDC-22702-XP1A - Teleflex Incorporated - Vascular Access Product Catalog
CDC-22702-XP1A 7 2 Fr. Lumen 16 cm catheter length .025 inch dia. spring-wire guide Pressure Injectable Arrowg+ard Blue® Two-Lumen CVC Contents: 1: Arrowg+ard Blue® Two-Lumen Catheter: 7 Fr. (2.5 mm OD) x 16 cm, Pressure Injectable 1: Spring-Wire Guide, Marked: .025" (0.64 mm) dia. x 23-5/8" (60 cm) (Straight Soft Tip on One End - "J" Tip on Other) with Arrow Advancer 1: Catheter: 20 Ga. x 1-3/4" (4.45 cm) Radiopaque over 22 Ga. TW Introducer Needle 1: Introducer Needle: Echogenic 18 Ga. x 2-1/2" (6.35 cm) RW 1: Injection Needle: SafetyGlideTM1 25 Ga. x 1" (2.54 cm) 1: Blunt Fill Needle: 18 Ga. x 1-1/2" (3.81 cm) 1: Pressure Transduction Probe 1: Introducer Needle: Echogenic 20 Ga. x 1-1/2" (3.81 cm) XTW and 5 mL Arrow® Raulerson Spring-Wire Introduction Syringe 1: Injection Needle: SafetyGlideTM1 22 Ga. x 1-1/2" (3.81 cm) and 5 mL Luer-Slip Syringe 1: Syringe: 3 mL Luer-Lock 1: Tissue Dilator: 8.5 Fr. (2.8 mm) x 10.2 cm 2: 10 mL Luer-Lock Pre-Filled Saline Syringe 1: 5 mL 1% Lidocaine HCl Solution and Alcohol Prep 1: 3 mL Applicator 2% CHG and 70% IPA ChloraPrep®2 One-Step Solution with Hi-Lite OrangeTM Tint 1: SecondSiteTM Adjustable Hub: Fastener 1: SecondSiteTM Adjustable Hub: Catheter Clamp 1: SharpsAway® Disposal Cup 1: SharpsAway® II Locking Disposal Cup 1: Maximal Barrier DrapeTM with 4" fenestration 1: Towel 1: Needle Holder 1: Safety Scalpel: #11 1: Checklist/CLIP Sheet 1: Flow Rate Information Card with Injection Log 1: Sterile Procedure Sign 1: Medication Label: 1% Lidocaine 2: Gauze Pad: 2" x 2" (5 cm x 5 cm) 5: Gauze Pad: 4" x 4" (10 cm x 10 cm) 1: Dressing: Tegaderm®3 10 cm x 12 cm 1: Surgical Apparel: Impervious Gown 1: Dressing: BIOPATCH®4 1: Surgical Apparel: Bouffant Cap 1: Surgical Apparel: Mask with Eye Shield 1: Suture: 3-0 Silk with Curved Needle 1: Tubing±: 20" (50 cm) Extension 1: HemoHopper® Fluid Receptacle 1A trademark of Becton, Dickinson and Company. 2A registered trademark of CareFusion or one of its subsidiaries. 3A registered trademark of 3M Company. 4A registered trademark of Johnson & Johnson Corporation. ±Precaution: Contains Phthalate: DEHP. Warning: The results of certain animal experiments have shown phthalates to be potentially toxic to reproduction. Proceeding from the present state of scientific knowledge, risks for male premature infants cannot be excluded in the case of long-term exposure or application. Medical products containing phthalates should be used only temporarily with pregnant women, nursing mothers, babies and infants. Not made with natural rubber latex. Store between 20 25°C (68 77°F). Arrow International provides the enclosed medication label(s) for your convenience. Please ensure that these labels are applied to the correct syringe and corresponding medication. Contraindications: The Arrowg+ard Blue antimicrobial catheter is contraindicated for patients with known hypersensitivity to chlorhexidine, silver sulfadiazine and/or sulfa drugs. Lumen Priming Volume* (mL) Distal (18 Ga.) 0.33 Proximal (14 Ga.) 0.50 Gravity Flow Rate (mL/hr) 1079 4648 MAX Pressure Injection Flow Rate** (mL/sec) 5 10 * Priming volumes are approximate and are done without accessories. Flow rate values are approximate and are determined using deionized water at 100 cm head height. ** Pressure injection flow rates are determined using media of 11.8 centipoise (cP) viscosity, with 152 cm administration set tubing. LBL052872 R00 (2022-01)iText 2.1.7 by 1T3XT