Owner's Manual for MEAN WELL models including: RSP-750-5, RSP-750-12, RSP-750-15, RSP-750-24, RSP-750-27, RSP-750-48, RSP-750 Series 750W Power Supply with Single Output, 750W Power Supply with Single Output, Supply with Single Output, Single Output

RSP-750-20250110

wangj

RSP-750-12 MEAN WELL - РКС Компоненти - РАДІОМАГ

RSP-750-5 MEAN WELL - RADIOMAG GmbH


File Info : application/pdf, 8 Pages, 224.66KB

PDF preview unavailable. Download the PDF instead.

rsp750spec
750W Power Supply with Single Output
Dimension
L *W* H 250 * 127 * 41 (1U) mm 9.84 * 5 * 1.61 (1U) inch

RSP-750 series
User's Manual

R33100 RoHS

UL62368-1

Bauart gepruft Sicherheit
egelma ge od o s be wac g
www. tuv.com ID 2000000000
BS EN/EN62368-1

GB4943.1

TPTC004

THOMAS SAMUEL

THOMAS SAMUEL

IS13252 (except 48V)

IEC62368-1
 Features
Universal AC input / Full range Built-in active PFC function High efficiency up to 92% Forced air cooling by built-in DC fan Output voltage and constant current level programmable Built-in remote ON-OFF control / remote sense /
auxiliary power / DC OK signal
Protections: Short circuit / Overload / Over voltage / Over temperature
Optional conformal coating 5 years warranty

 Applications
Factory control or automation apparatus Test and measurement instrument Laser related machine Burn-in facility RF application
 GTIN CODE
MW Search: https://www.meanwell.com/serviceGTIN.aspx

 Description
RSP-750 is a 750W single output enclosed type AC/DC power supply. This series operates for 90~264VAC input voltage and offers the models with the DC output mostly demanded from the industry. Each model is cooled by the built-in fan with fan speed control, working for the temperature up to 70. Moreover, RSP-750 provides vast design flexibility by equipping various built-in functions such as the output programming, remote ON-OFF control, auxiliary power, etc.

 Model Encoding / Order Information RSP - 750 - 48

Downloaded from Arrow.com.

Output voltage (5V/12V/15V/24V/27V/48V) Output wattage Series name

File Name:RSP-750-SPEC 2025-01-10

750W Power Supply with Single Output

RSP-750 series

SPECIFICATION

MODEL

RSP-750-5

RSP-750-12

RSP-750-15

RSP-750-24

RSP-750-27

RSP-750-48

DC VOLTAGE

5V

12V

15V

24V

27V

48V

RATED CURRENT

100A

62.5A

50A

31.3A

27.8A

15.7A

CURRENT RANGE

0 ~ 100A

0 ~ 62.5A

0 ~ 50A

0 ~ 31.3A

0 ~ 27.8A

0 ~ 15.7A

RATED POWER

500W

750W

750W

751.2W

750.6W

753.6W

RIPPLE & NOISE (max.) Note.2 150mVp-p

150mVp-p

150mVp-p

150mVp-p

150mVp-p

150mVp-p

OUTPUT

VOLTAGE ADJ. RANGE

4.75 ~ 5.5V

VOLTAGE TOLERANCE Note.3 ±2.0%

LINE REGULATION

±0.5%

LOAD REGULATION

±2.0%

10 ~ 13.5V ±1.0% ±0.5% ±0.5%

13.5 ~ 16.5V ±1.0% ±0.5% ±0.5%

20 ~ 26.4V ±1.0% ±0.5% ±0.5%

24 ~ 30V ±1.0% ±0.5% ±0.5%

43 ~ 55V ±1.0% ±0.5% ±0.5%

SETUP, RISE TIME

1000ms, 50ms at full load

HOLD UP TIME (Typ.)

16ms/230VAC 16ms/115VAC at full load

VOLTAGE RANGE

Note.4 90 ~ 264VAC 127 ~ 370VDC

FREQUENCY RANGE

47 ~ 63Hz

POWER FACTOR (Typ.)

0.97/230VAC 0.98/115VAC at full load

INPUT EFFICIENCY (Typ.)

82%

87%

89%

90.5%

90.5%

92%

AC CURRENT (Typ.) INRUSH CURRENT (Typ.)

5V : 5.6A/115VAC 2.8A/230VAC 25A/115VAC 40A/230VAC

12V~48V : 8.2A/115VAC

3.9A/230VAC

LEAKAGE CURRENT

<2.0mA / 240VAC

OVERLOAD

105 ~ 125% rated output power Protection type : Constant current limiting, recovers automatically after fault condition is removed

PROTECTION OVER VOLTAGE (OVP)

5.75 ~ 6.75V

13.8 ~ 16.8V

17 ~ 20.5V

27.6 ~ 32.4V

Protection type : Shut down o/p voltage, re-power on to recover

31 ~ 36.5V

56.6 ~ 66.2V

OVER TEMPERATURE

Shut down o/p voltage, recovers automatically after temperature goes down

OUTPUT VOLTAGE PROGRAMMABLE(PV) Adjustment of output voltage is allowable to 40 ~ 110% of nominal output voltage. Please refer to the Function Manual.

CONSTANT CURRENT LEVEL PROGRAMMABLE(PC) Adjustment of constant current level is allowable to 40 ~ 110% of rated current. Please refer to the Function Manual.

FUNCTION AUXILIARY POWER

12V @ 0.1A ; tolerance : ±10%

REMOTE ON-OFF CONTROL Power on : short between Remote ON-OFF(pin13) & 12V-AUX(pin14) on CN50 Power off : open between Remote ON-OFF(pin13) & 12-AUX(pin14) on CN50

DC OK SIGNAL WORKING TEMP. WORKING HUMIDITY ENVIRONMENT STORAGE TEMP., HUMIDITY TEMP. COEFFICIENT VIBRATION
SAFETY STANDARDS
WITHSTAND VOLTAGE ISOLATION RESISTANCE

The TTL signal out, power supply turn on = 0 ~ 1V ; power supply turn off = 3.3 ~ 5.6V

-30 ~ +70 (Refer to "Derating Curve")

20 ~ 90% RH non-condensing

-40 ~ +85, 10 ~ 95% RH non-condensing

±0.03%/ (0 ~ 50)

10 ~ 500Hz, 2G 10min./1cycle, 60min. each along X, Y, Z axes

UL62368-1, CSA C22.2 No. 62368-1, TUV BS EN/EN62368-1, CCC GB4943.1, BSMI CNS15598-1, AS/NZS62368.1, EAC TP TC 004, BIS IS13252(Part1): 2010/IEC 60950-1:2005(except for 48V) approved

I/P-O/P:3KVAC I/P-FG:2KVAC O/P-FG:0.5KVAC

I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25/ 70% RH

Parameter

Standard

Test Level / Note

Conducted

BS EN/EN55032 (CISPR32),CNS15936 Class B

EMC EMISSION

Radiated

BS EN/EN55032 (CISPR32),CNS15936 Class B

Harmonic Current

BS EN/EN61000-3-2

-----

SAFETY &
EMC (Note 7)

Voltage Flicker

BS EN/EN61000-3-3

BS EN/EN55024, BS EN/EN61000-6-2, CCC GB17625.1,GB/T9254

Parameter

Standard

----Test Level / Note

ESD

BS EN/EN61000-4-2

Level 3, 8KV air ; Level 2, 4KV contact

Radiated

BS EN/EN61000-4-3

Level 3

EMC IMMUNITY

EFT / Burst Surge Conducted

BS EN/EN61000-4-4 BS EN/EN61000-4-5 BS EN/EN61000-4-6

Level 3 Level 4, 4KV/Line-Earth ; Level 3, 2KV/Line-Line Level 3

Magnetic Field

BS EN/EN61000-4-8

Level 4

Voltage Dips and Interruptions

BS EN/EN61000-4-11

>95% dip 0.5 periods, 30% dip 25 periods, >95% interruptions 250 periods

OTHERS NOTE

MTBF

336.9K hrs min. Telcordia SR-332 (Bellcore) ; 109.1K hrs min. MIL-HDBK-217F (25)

DIMENSION

250*127*41mm (L*W*H)

PACKING

1.64Kg; 6pcs/10.8Kg/1.1CUFT

1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25 of ambient temperature.

2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1F & 47F parallel capacitor.

3. Tolerance : includes set up tolerance, line regulation and load regulation.

4. Derating may be needed under low input voltages. Please check the derating curve for more details.

5. There is high possibility to trigger the floating over voltage protection when PV voltage is trimmed from a high voltage level to a lower voltage level at light

load or no load condition. It is suggested that turn off the power supply and set PV voltage to the lowest level, then adjust output voltage to a desired value.

6. Strongly recommended that external output capacitance should not exceed 5000uF. (Only for: RSP-750-5)

7. The power supply is considered a component which will be installed into a final equipment. All the EMC tests are been executed by mounting the unit on

a 720mm*360mm metal plate with 1mm of thickness. The final equipment must be re-confirmed that it still meets EMC directives. For guidance on how to

perform these EMC tests, please refer to EMI testing of component power supplies.

(as available on https://www.meanwell.com//Upload/PDF/EMI_statement_en.pdf ) 8. The ambient temperature derating of 3.5/1000m with fanless models and of 5/1000m with fan models for operating altitude higher than 2000m(6500ft).

9. Products sourced from Taiwan do not have the BIS logo, please contact your MEAN WELL sales for more information.

 Product Liability DisclaimerFor detailed information, please refer to https://www.meanwell.com/serviceDisclaimer.aspx

Downloaded from Arrow.com.

File Name:RSP-750-SPEC 2025-01-10

750W Single Output Power Supply
Block Diagram

I/P

EMI FILTER

ACTIVE INRUSH CURRENT LIMITING

RECTIFIERS & PFC

POWER SWITCHING

O.L.P.

RECTIFIERS &
FILTER

PFC CONTROL

PWM CONTROL

AUX POWER

DETECTION CIRCUIT
O.V.P.
RECTIFIERS CONTROL ON/OFF FAN RECTIFIERS
& FILTER

RSP-750 series

PFC fosc : 90KHz

+S

PWM fosc : 70KHz

+V -V

-S

DC OK PV/PC

REMOTE ON-OFF
AUX POWER(12V/0.1A) AUX GND

Static Characteristics

100 90 80 70 60 50 40

90

95

100

115

264

INPUT VOLTAGE (VAC) 60Hz

MODEL INPUT
100~264VAC

5V
500W 100A

90VAC MODEL
INPUT 100~264VAC

450W 90A
24V
751.2W 31.3A

90VAC

676.08W 28.17A

12V
750W 62.5A 675W 56.25A
27V
750.6W 27.8A 675.54W 25.02A

15V
750W 50A 675W 45A
48V
753.6W 15.7A 678.24W 14.13A

Derating Curve

Efficiency vs Load (48V Model)

95

100
90

EFFICIENCY (%)

80
85

60

50

80

40

75
20

70

-30

0

10

20

30

40

50

60

70 (HORIZONTAL)

10% 20% 30% 40% 50% 60% 70% 80% 90% 100%

AMBIENT TEMPERATURE ()

LOAD

 The curve above is measured at 230VAC.

230V

LOAD (%)

LOAD (%)

Downloaded from Arrow.com.

File Name:RSP-750-SPEC 2025-01-10

750W Single Output Power Supply
Function Manual
1.Remote Sense The remote sensing compensates voltage drop on the load wiring up to 0.5V.

RSP-750 series

TB1 CN50

-V

+V

LOAD PIN3 -S - + PIN1 +S

1

13

2

14

1

35

7 CN50

13

+S -S PV PC DC_OK GND REMOTE ON-OFF

+VS -VS PS PO GND G-AUX 12V-AUX

2 46 8

14

Fig 1.1

 The +S signal should be connected to the positive terminal of the load whereas -S signal to the negative terminal.  By factory default, on CN50, Remote ON-OFF (pin13) and 12V-AUX (pin14), PV(pin5) and PS (pin6), and PC (pin7) and PO (pin8, respectively, are
shorted when shipped. The power supply will have no output if the shorting connector is not assembled unless certain functin needs to be activated.

2.Remote ON-OFF  The power supply can be turned ON/OFF by using the "Remote ON-OFF" function.

TB1 CN50

-V

+V

LOAD

-+

1

13

2

14

CN50

1 35 7

13

+S

-S

PV

PC

DC_OK

GND

REMOTE ON-OFF

SW

+VS -VS PS PO GND G-AUX 12V-AUX

2 46 8

14

Fig 2.1

Between Remote ON-OFF(pin13) and 12V-AUX(pin14) SW close (Short) SW open (Open)

Power Supply Status ON OFF

 When multiple power supplies need to turn ON/OFF simultaneously by Remote ON-OFF control, -S & -V on CN50, as well as +S & +V, on each power supply should be connected.

Downloaded from Arrow.com.

File Name:RSP-750-SPEC 2025-01-10

750W Single Output Power Supply

RSP-750 series

3. Output Voltage Programming (or, PV / remote voltage programming / remote adjust / margin programming / dynamic voltage trim)  In addition to the adjustment via the built-in potentiometer, the output voltage can be trimmed to 40~110% of the nominal voltage by applying
EXTERNAL VOLTAGE.

Nominal Vout
120 110 100

Vout 120%(Typ.)

External Voltage (2~5.5VDC)

OUTPUT VOLTAGE (%)

80

Non-Linear

60

40

20

UVP 10%(Typ.)

1 2 3 4 5 5.5 6
EXTERNAL VOLTAGE (VDC)
 If EXTERNAL VOLTAGE (VDC) <0.5V,the power supply may enter under voltage protection; it needs to be restarted to work.

1

3

5

7 CN50

11

13

+S

-S

PV

PC

DC_OK

GND

REMOTE ON-OFF

+VS -VS PS PO GND G-AUX 12V-AUX

24

8

14

Fig 3.1

 Caution: By factory default, the Output Voltage Programming is not activated, and PV (pin5) and PS(pin6) are shorted by connector. Whenever this function is not needed to activate, as assumed in other sections' diagrams, please keep PV (pin5) and PS(pin6) shorted ; other wise, the power supply will have no output.

4. Constant Current Level Programming (or, PC / remote current programming / dynamic current trim)  The constant current level can be trimmed to 40~110% of the rated current by applying EXTERNAL VOLTAGE.

CONSTANT CURRENT LEVEL (%)

Rated Current
120 110 100

80

Non-Linear

60

40 20

Io 115%(Typ.)

External Voltage (2~5.5VDC)

1 3 5 7 CN50 11

13

+S

-S

PV

PC

DC_OK

GND

REMOTE ON-OFF

+VS -VS PS PO GND G-AUX 12V-AUX

2 46

14

1 2 3 4 5 5.5 6
EXTERNAL VOLTAGE (VDC)

Fig 4.1

 Caution: By factory default, the Output Current Programming is not activated, and PC(pin7) and PO(pin8) are shorted by connector. Whenever this function is not needed to activate, as assumed in other sections' diagrams, please keep PC(pin7) and PO(pin8) shorted ; otherwise, the power supply will have no output.

Downloaded from Arrow.com.

TB1 CN50

-V

+V

LOAD

-+

1

13

2

14

File Name:RSP-750-SPEC 2025-01-10

750W Single Output Power Supply

RSP-750 series

5.DC_OK signal  "DC_OK" is an open collector signal. It indicates the output status of the power supply. It can operate in two ways : One is sinking current from external TTL signal ; the other is sending out a TTL voltage signal.
 Sinking current from external TTL signal: The maximum sink current is 10mA and the maximum external voltage is 5.6V.  Sending out TTL voltage signal :
Between DC- OK(pin9) and GND(pin10&11) Output Status

0 ~ 1V

Power supply ON

3.3 ~ 5.6V

Power supply OFF

TB1 CN50

-V

+V

LOAD

-+

1

13

2

14

CN50

1 3 5 7 9 11

13

+S

-S

PV

PC

DC_OK

GND

REMOTE ON-OFF

+VS -VS PS PO GND G-AUX 12V-AUX

2 46 8

14

Fig 5.1

Downloaded from Arrow.com.

File Name:RSP-750-SPEC 2025-01-10

750W Single Output Power Supply

RSP-750 series

Mechanical Specification
(Unit: mm , tolerance ± 1mm)

236 6

20.5

3-M4 L=6
1

41

33.5

18.5

2-M5

-V

+V

2

SVR51

21
CN50
14 13

90

10 7

3 2 1
TB1

3-M4 L=4
2

1
3-M4 L=6

250 231.5

127

20.5

6 236

 Mounting Instruction

Hole No. Recommended Screw Size

1

M4

2

M4

MAX. Penetration Depth L 6mm 4mm

Recommended mounting torque 7~11Kgf-cm 7~11Kgf-cm

Control Pin No. Assignment (CN50) : HRS DF11-14DP-2DS or equivalent 1 13 Mating Housing HRS DF11-14DS or equivalent

2 14

Terminal HRS DF11-**SC or equivalent

7.8 25.4

63.5

25.4 7.8

Case No.212A
1 1

Air flow direction
2

1 1

Mounting Surface

Chassis of RSP-750

Mounting Screw

Pin No. Function Description

1

+S Positive sensing for remote sense.

2

+VS +V Signal. The +VS should be connected to the +S to reduce the noise when "output voltage programming" function is in use.

3

-S Negative sensing for remote sense.

4

-VS -V Signal. The -VS should be connected to the -S to reduce the noise when "output voltage programming" function is in use.

5

PV Connect to external DC voltage source for output voltage programming, referenced to pin 10,11 (GND).

6

PS Reference pin regarding output voltage programming. Please refer to the Function Manual.

7

PC Connect to external DC voltage source for output current programming.

8

PO Reference pin regarding output current programming. Please refer to the Function Manual.

9

DC_OK

Open collector signal, referenced to pin10,11(GND). Low when PSU turns on. The maximum sink current is 10mA and the maximum external voltage is 5.6V.

10,11 12

GND These pins connect to the negative terminal (-V). Return for DC_OK Signal output.

G-AUX

Auxiliary voltage output ground. The signal return is isolated from the output terminals (+V & -V).

13

REMOTE Turns the output on and off by electrical or dry contact between pin 13 ( ON/OFF) and pin 14 (12V-AUX). ON-OFF Short: Power ON, Open: Power OFF.

14

12V-AUX

Auxiliary voltage output, 10.8~13.2V, referenced to pin 12(G-AUX). The maximum load current is 0.1A. This output is not controlled by the

"remote

ON/OFF

control".

Downloaded from Arrow.com.

File Name:RSP-750-SPEC 2025-01-10

750W Single Output Power Supply

AC Input Terminal Pin No. Assignment

Pin No. Assignment

Diagram

1

AC/N

2

AC/L

3

FG

DC Output Terminal Pin No. Assignment

Assignment

Diagram

+V, -V

Maximum mounting torque 18Kgf-cm
Maximum mounting torque 10Kgf-cm

Installation Manual
Please refer to : http://www.meanwell.com/manual.html

RSP-750 series

Downloaded from Arrow.com.

File Name:RSP-750-SPEC 2025-01-10



References

Acrobat Distiller 9.0.0 (Windows); modified using iText 5.5.6 ©2000-2015 iText Group NV (AGPL-version) (AGPL-version)