Owner's Manual for MEAN WELL models including: RSP-750-5, RSP-750-12, RSP-750-15, RSP-750-24, RSP-750-27, RSP-750-48, RSP-750 Series 750W Power Supply with Single Output, 750W Power Supply with Single Output, Supply with Single Output, Single Output
RSP-750-12 MEAN WELL - РКС Компоненти - РАДІОМАГ
RSP-750-5 MEAN WELL - RADIOMAG GmbH
File Info : application/pdf, 8 Pages, 224.66KB
DocumentDocument750W Power Supply with Single Output Dimension L *W* H 250 * 127 * 41 (1U) mm 9.84 * 5 * 1.61 (1U) inch RSP-750 series User's Manual R33100 RoHS UL62368-1 Bauart gepruft Sicherheit egelma ge od o s be wac g www. tuv.com ID 2000000000 BS EN/EN62368-1 GB4943.1 TPTC004 THOMAS SAMUEL THOMAS SAMUEL IS13252 (except 48V) IEC62368-1 Features Universal AC input / Full range Built-in active PFC function High efficiency up to 92% Forced air cooling by built-in DC fan Output voltage and constant current level programmable Built-in remote ON-OFF control / remote sense / auxiliary power / DC OK signal Protections: Short circuit / Overload / Over voltage / Over temperature Optional conformal coating 5 years warranty Applications Factory control or automation apparatus Test and measurement instrument Laser related machine Burn-in facility RF application GTIN CODE MW Search: https://www.meanwell.com/serviceGTIN.aspx Description RSP-750 is a 750W single output enclosed type AC/DC power supply. This series operates for 90~264VAC input voltage and offers the models with the DC output mostly demanded from the industry. Each model is cooled by the built-in fan with fan speed control, working for the temperature up to 70. Moreover, RSP-750 provides vast design flexibility by equipping various built-in functions such as the output programming, remote ON-OFF control, auxiliary power, etc. Model Encoding / Order Information RSP - 750 - 48 Downloaded from Arrow.com. Output voltage (5V/12V/15V/24V/27V/48V) Output wattage Series name File Name:RSP-750-SPEC 2025-01-10 750W Power Supply with Single Output RSP-750 series SPECIFICATION MODEL RSP-750-5 RSP-750-12 RSP-750-15 RSP-750-24 RSP-750-27 RSP-750-48 DC VOLTAGE 5V 12V 15V 24V 27V 48V RATED CURRENT 100A 62.5A 50A 31.3A 27.8A 15.7A CURRENT RANGE 0 ~ 100A 0 ~ 62.5A 0 ~ 50A 0 ~ 31.3A 0 ~ 27.8A 0 ~ 15.7A RATED POWER 500W 750W 750W 751.2W 750.6W 753.6W RIPPLE & NOISE (max.) Note.2 150mVp-p 150mVp-p 150mVp-p 150mVp-p 150mVp-p 150mVp-p OUTPUT VOLTAGE ADJ. RANGE 4.75 ~ 5.5V VOLTAGE TOLERANCE Note.3 ±2.0% LINE REGULATION ±0.5% LOAD REGULATION ±2.0% 10 ~ 13.5V ±1.0% ±0.5% ±0.5% 13.5 ~ 16.5V ±1.0% ±0.5% ±0.5% 20 ~ 26.4V ±1.0% ±0.5% ±0.5% 24 ~ 30V ±1.0% ±0.5% ±0.5% 43 ~ 55V ±1.0% ±0.5% ±0.5% SETUP, RISE TIME 1000ms, 50ms at full load HOLD UP TIME (Typ.) 16ms/230VAC 16ms/115VAC at full load VOLTAGE RANGE Note.4 90 ~ 264VAC 127 ~ 370VDC FREQUENCY RANGE 47 ~ 63Hz POWER FACTOR (Typ.) 0.97/230VAC 0.98/115VAC at full load INPUT EFFICIENCY (Typ.) 82% 87% 89% 90.5% 90.5% 92% AC CURRENT (Typ.) INRUSH CURRENT (Typ.) 5V : 5.6A/115VAC 2.8A/230VAC 25A/115VAC 40A/230VAC 12V~48V : 8.2A/115VAC 3.9A/230VAC LEAKAGE CURRENT <2.0mA / 240VAC OVERLOAD 105 ~ 125% rated output power Protection type : Constant current limiting, recovers automatically after fault condition is removed PROTECTION OVER VOLTAGE (OVP) 5.75 ~ 6.75V 13.8 ~ 16.8V 17 ~ 20.5V 27.6 ~ 32.4V Protection type : Shut down o/p voltage, re-power on to recover 31 ~ 36.5V 56.6 ~ 66.2V OVER TEMPERATURE Shut down o/p voltage, recovers automatically after temperature goes down OUTPUT VOLTAGE PROGRAMMABLE(PV) Adjustment of output voltage is allowable to 40 ~ 110% of nominal output voltage. Please refer to the Function Manual. CONSTANT CURRENT LEVEL PROGRAMMABLE(PC) Adjustment of constant current level is allowable to 40 ~ 110% of rated current. Please refer to the Function Manual. FUNCTION AUXILIARY POWER 12V @ 0.1A ; tolerance : ±10% REMOTE ON-OFF CONTROL Power on : short between Remote ON-OFF(pin13) & 12V-AUX(pin14) on CN50 Power off : open between Remote ON-OFF(pin13) & 12-AUX(pin14) on CN50 DC OK SIGNAL WORKING TEMP. WORKING HUMIDITY ENVIRONMENT STORAGE TEMP., HUMIDITY TEMP. COEFFICIENT VIBRATION SAFETY STANDARDS WITHSTAND VOLTAGE ISOLATION RESISTANCE The TTL signal out, power supply turn on = 0 ~ 1V ; power supply turn off = 3.3 ~ 5.6V -30 ~ +70 (Refer to "Derating Curve") 20 ~ 90% RH non-condensing -40 ~ +85, 10 ~ 95% RH non-condensing ±0.03%/ (0 ~ 50) 10 ~ 500Hz, 2G 10min./1cycle, 60min. each along X, Y, Z axes UL62368-1, CSA C22.2 No. 62368-1, TUV BS EN/EN62368-1, CCC GB4943.1, BSMI CNS15598-1, AS/NZS62368.1, EAC TP TC 004, BIS IS13252(Part1): 2010/IEC 60950-1:2005(except for 48V) approved I/P-O/P:3KVAC I/P-FG:2KVAC O/P-FG:0.5KVAC I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25/ 70% RH Parameter Standard Test Level / Note Conducted BS EN/EN55032 (CISPR32),CNS15936 Class B EMC EMISSION Radiated BS EN/EN55032 (CISPR32),CNS15936 Class B Harmonic Current BS EN/EN61000-3-2 ----- SAFETY & EMC (Note 7) Voltage Flicker BS EN/EN61000-3-3 BS EN/EN55024, BS EN/EN61000-6-2, CCC GB17625.1,GB/T9254 Parameter Standard ----Test Level / Note ESD BS EN/EN61000-4-2 Level 3, 8KV air ; Level 2, 4KV contact Radiated BS EN/EN61000-4-3 Level 3 EMC IMMUNITY EFT / Burst Surge Conducted BS EN/EN61000-4-4 BS EN/EN61000-4-5 BS EN/EN61000-4-6 Level 3 Level 4, 4KV/Line-Earth ; Level 3, 2KV/Line-Line Level 3 Magnetic Field BS EN/EN61000-4-8 Level 4 Voltage Dips and Interruptions BS EN/EN61000-4-11 >95% dip 0.5 periods, 30% dip 25 periods, >95% interruptions 250 periods OTHERS NOTE MTBF 336.9K hrs min. Telcordia SR-332 (Bellcore) ; 109.1K hrs min. MIL-HDBK-217F (25) DIMENSION 250*127*41mm (L*W*H) PACKING 1.64Kg; 6pcs/10.8Kg/1.1CUFT 1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25 of ambient temperature. 2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1F & 47F parallel capacitor. 3. Tolerance : includes set up tolerance, line regulation and load regulation. 4. Derating may be needed under low input voltages. Please check the derating curve for more details. 5. There is high possibility to trigger the floating over voltage protection when PV voltage is trimmed from a high voltage level to a lower voltage level at light load or no load condition. It is suggested that turn off the power supply and set PV voltage to the lowest level, then adjust output voltage to a desired value. 6. Strongly recommended that external output capacitance should not exceed 5000uF. (Only for: RSP-750-5) 7. The power supply is considered a component which will be installed into a final equipment. All the EMC tests are been executed by mounting the unit on a 720mm*360mm metal plate with 1mm of thickness. The final equipment must be re-confirmed that it still meets EMC directives. For guidance on how to perform these EMC tests, please refer to EMI testing of component power supplies. (as available on https://www.meanwell.com//Upload/PDF/EMI_statement_en.pdf ) 8. The ambient temperature derating of 3.5/1000m with fanless models and of 5/1000m with fan models for operating altitude higher than 2000m(6500ft). 9. Products sourced from Taiwan do not have the BIS logo, please contact your MEAN WELL sales for more information. Product Liability DisclaimerFor detailed information, please refer to https://www.meanwell.com/serviceDisclaimer.aspx Downloaded from Arrow.com. File Name:RSP-750-SPEC 2025-01-10 750W Single Output Power Supply Block Diagram I/P EMI FILTER ACTIVE INRUSH CURRENT LIMITING RECTIFIERS & PFC POWER SWITCHING O.L.P. RECTIFIERS & FILTER PFC CONTROL PWM CONTROL AUX POWER DETECTION CIRCUIT O.V.P. RECTIFIERS CONTROL ON/OFF FAN RECTIFIERS & FILTER RSP-750 series PFC fosc : 90KHz +S PWM fosc : 70KHz +V -V -S DC OK PV/PC REMOTE ON-OFF AUX POWER(12V/0.1A) AUX GND Static Characteristics 100 90 80 70 60 50 40 90 95 100 115 264 INPUT VOLTAGE (VAC) 60Hz MODEL INPUT 100~264VAC 5V 500W 100A 90VAC MODEL INPUT 100~264VAC 450W 90A 24V 751.2W 31.3A 90VAC 676.08W 28.17A 12V 750W 62.5A 675W 56.25A 27V 750.6W 27.8A 675.54W 25.02A 15V 750W 50A 675W 45A 48V 753.6W 15.7A 678.24W 14.13A Derating Curve Efficiency vs Load (48V Model) 95 100 90 EFFICIENCY (%) 80 85 60 50 80 40 75 20 70 -30 0 10 20 30 40 50 60 70 (HORIZONTAL) 10% 20% 30% 40% 50% 60% 70% 80% 90% 100% AMBIENT TEMPERATURE () LOAD The curve above is measured at 230VAC. 230V LOAD (%) LOAD (%) Downloaded from Arrow.com. File Name:RSP-750-SPEC 2025-01-10 750W Single Output Power Supply Function Manual 1.Remote Sense The remote sensing compensates voltage drop on the load wiring up to 0.5V. RSP-750 series TB1 CN50 -V +V LOAD PIN3 -S - + PIN1 +S 1 13 2 14 1 35 7 CN50 13 +S -S PV PC DC_OK GND REMOTE ON-OFF +VS -VS PS PO GND G-AUX 12V-AUX 2 46 8 14 Fig 1.1 The +S signal should be connected to the positive terminal of the load whereas -S signal to the negative terminal. By factory default, on CN50, Remote ON-OFF (pin13) and 12V-AUX (pin14), PV(pin5) and PS (pin6), and PC (pin7) and PO (pin8, respectively, are shorted when shipped. The power supply will have no output if the shorting connector is not assembled unless certain functin needs to be activated. 2.Remote ON-OFF The power supply can be turned ON/OFF by using the "Remote ON-OFF" function. TB1 CN50 -V +V LOAD -+ 1 13 2 14 CN50 1 35 7 13 +S -S PV PC DC_OK GND REMOTE ON-OFF SW +VS -VS PS PO GND G-AUX 12V-AUX 2 46 8 14 Fig 2.1 Between Remote ON-OFF(pin13) and 12V-AUX(pin14) SW close (Short) SW open (Open) Power Supply Status ON OFF When multiple power supplies need to turn ON/OFF simultaneously by Remote ON-OFF control, -S & -V on CN50, as well as +S & +V, on each power supply should be connected. Downloaded from Arrow.com. File Name:RSP-750-SPEC 2025-01-10 750W Single Output Power Supply RSP-750 series 3. Output Voltage Programming (or, PV / remote voltage programming / remote adjust / margin programming / dynamic voltage trim) In addition to the adjustment via the built-in potentiometer, the output voltage can be trimmed to 40~110% of the nominal voltage by applying EXTERNAL VOLTAGE. Nominal Vout 120 110 100 Vout 120%(Typ.) External Voltage (2~5.5VDC) OUTPUT VOLTAGE (%) 80 Non-Linear 60 40 20 UVP 10%(Typ.) 1 2 3 4 5 5.5 6 EXTERNAL VOLTAGE (VDC) If EXTERNAL VOLTAGE (VDC) <0.5V,the power supply may enter under voltage protection; it needs to be restarted to work. 1 3 5 7 CN50 11 13 +S -S PV PC DC_OK GND REMOTE ON-OFF +VS -VS PS PO GND G-AUX 12V-AUX 24 8 14 Fig 3.1 Caution: By factory default, the Output Voltage Programming is not activated, and PV (pin5) and PS(pin6) are shorted by connector. Whenever this function is not needed to activate, as assumed in other sections' diagrams, please keep PV (pin5) and PS(pin6) shorted ; other wise, the power supply will have no output. 4. Constant Current Level Programming (or, PC / remote current programming / dynamic current trim) The constant current level can be trimmed to 40~110% of the rated current by applying EXTERNAL VOLTAGE. CONSTANT CURRENT LEVEL (%) Rated Current 120 110 100 80 Non-Linear 60 40 20 Io 115%(Typ.) External Voltage (2~5.5VDC) 1 3 5 7 CN50 11 13 +S -S PV PC DC_OK GND REMOTE ON-OFF +VS -VS PS PO GND G-AUX 12V-AUX 2 46 14 1 2 3 4 5 5.5 6 EXTERNAL VOLTAGE (VDC) Fig 4.1 Caution: By factory default, the Output Current Programming is not activated, and PC(pin7) and PO(pin8) are shorted by connector. Whenever this function is not needed to activate, as assumed in other sections' diagrams, please keep PC(pin7) and PO(pin8) shorted ; otherwise, the power supply will have no output. Downloaded from Arrow.com. TB1 CN50 -V +V LOAD -+ 1 13 2 14 File Name:RSP-750-SPEC 2025-01-10 750W Single Output Power Supply RSP-750 series 5.DC_OK signal "DC_OK" is an open collector signal. It indicates the output status of the power supply. It can operate in two ways : One is sinking current from external TTL signal ; the other is sending out a TTL voltage signal. Sinking current from external TTL signal: The maximum sink current is 10mA and the maximum external voltage is 5.6V. Sending out TTL voltage signal : Between DC- OK(pin9) and GND(pin10&11) Output Status 0 ~ 1V Power supply ON 3.3 ~ 5.6V Power supply OFF TB1 CN50 -V +V LOAD -+ 1 13 2 14 CN50 1 3 5 7 9 11 13 +S -S PV PC DC_OK GND REMOTE ON-OFF +VS -VS PS PO GND G-AUX 12V-AUX 2 46 8 14 Fig 5.1 Downloaded from Arrow.com. File Name:RSP-750-SPEC 2025-01-10 750W Single Output Power Supply RSP-750 series Mechanical Specification (Unit: mm , tolerance ± 1mm) 236 6 20.5 3-M4 L=6 1 41 33.5 18.5 2-M5 -V +V 2 SVR51 21 CN50 14 13 90 10 7 3 2 1 TB1 3-M4 L=4 2 1 3-M4 L=6 250 231.5 127 20.5 6 236 Mounting Instruction Hole No. Recommended Screw Size 1 M4 2 M4 MAX. Penetration Depth L 6mm 4mm Recommended mounting torque 7~11Kgf-cm 7~11Kgf-cm Control Pin No. Assignment (CN50) : HRS DF11-14DP-2DS or equivalent 1 13 Mating Housing HRS DF11-14DS or equivalent 2 14 Terminal HRS DF11-**SC or equivalent 7.8 25.4 63.5 25.4 7.8 Case No.212A 1 1 Air flow direction 2 1 1 Mounting Surface Chassis of RSP-750 Mounting Screw Pin No. Function Description 1 +S Positive sensing for remote sense. 2 +VS +V Signal. The +VS should be connected to the +S to reduce the noise when "output voltage programming" function is in use. 3 -S Negative sensing for remote sense. 4 -VS -V Signal. The -VS should be connected to the -S to reduce the noise when "output voltage programming" function is in use. 5 PV Connect to external DC voltage source for output voltage programming, referenced to pin 10,11 (GND). 6 PS Reference pin regarding output voltage programming. Please refer to the Function Manual. 7 PC Connect to external DC voltage source for output current programming. 8 PO Reference pin regarding output current programming. Please refer to the Function Manual. 9 DC_OK Open collector signal, referenced to pin10,11(GND). Low when PSU turns on. The maximum sink current is 10mA and the maximum external voltage is 5.6V. 10,11 12 GND These pins connect to the negative terminal (-V). Return for DC_OK Signal output. G-AUX Auxiliary voltage output ground. The signal return is isolated from the output terminals (+V & -V). 13 REMOTE Turns the output on and off by electrical or dry contact between pin 13 ( ON/OFF) and pin 14 (12V-AUX). ON-OFF Short: Power ON, Open: Power OFF. 14 12V-AUX Auxiliary voltage output, 10.8~13.2V, referenced to pin 12(G-AUX). The maximum load current is 0.1A. This output is not controlled by the "remote ON/OFF control". Downloaded from Arrow.com. File Name:RSP-750-SPEC 2025-01-10 750W Single Output Power Supply AC Input Terminal Pin No. Assignment Pin No. Assignment Diagram 1 AC/N 2 AC/L 3 FG DC Output Terminal Pin No. Assignment Assignment Diagram +V, -V Maximum mounting torque 18Kgf-cm Maximum mounting torque 10Kgf-cm Installation Manual Please refer to : http://www.meanwell.com/manual.html RSP-750 series Downloaded from Arrow.com. File Name:RSP-750-SPEC 2025-01-10