Installation Guide for Schneider Electric models including: PowerLogic HDPM6000 Series, Power Quality Metering System, PowerLogic HDPM6000 Series Power Quality Metering System
schneider-electric.com Z208150-0C 08/2021 PowerLogic DPM000 Series CT Models for 5A and 125A Installation Guide Split and Solid-Core For Use with the DPM000 Power uality Metering System
Difference among Rogowski coils, LVCTs and conventional CTs | Schneider Electric South Africa
Square D (Schneider Electric) METSEHDPM75A12 Split Core Current Transformer HDPM6000, 75A, 12Ft Lead | Graybar Store
File Info : application/pdf, 8 Pages, 466.77KB
DocumentDocumentPowerLogicTM HDPM6000 Series CT Models for 75A and 125A Split and Solid-Core For Use with the HDPM6000 Power Quality Metering System Installation Guide Z208150-0C 08/2021 schneider-electric.com PowerLogic HDPM6000 Series CT Models for 75A and 125A Split and Solid Core Safety Information Important information Read these instructions carefully and look at the equipment to become familiar with the device before trying to install, operate, service or maintain it. The following special messages may appear throughout this bulletin or on the equipment to warn of potential hazards or to call attention to information that clarifies or simplifies a procedure. The addition of either symbol to a "Danger" or "Warning" safety label indicates that an electrical hazard exists which will result in personal injury if the instructions are not followed. This is the safety alert symbol. It is used to alert you to potential personal injury hazards. Obey all safety messages that follow this symbol to avoid possible injury or death. DANGER DANGER indicates an hazardous situation which, if not avoided, will result in death or serious injury. WARNING WARNING indicates a hazardous situation which, if not avoided, could result in death or serious injury. CAUTION CAUTION indicates a hazardous situation which, if not avoided, could result in minor or moderate injury. NOTICE NOTICE is used to address practices not related to physical injury. Please note Electrical equipment should be installed, operated, serviced and maintained only by qualified personnel. No responsibility is assumed by Schneider Electric for any consequences arising out of the use of this material. A qualified person is one who has skills and knowledge related to the construction, installation and operation of electrical equipment and has received safety training to recognize and avoid the hazards involved. © 2021 Schneider Electric All Rights Reserved. PowerLogic HDPM6000 Series CT Models for 75A and 125A Split and Solid Core Safety Precautions Installation, wiring, testing and service must be performed in accordance with all local and national electrical codes. DANGER HAZARD OF ELECTRIC SHOCK, EXPLOSION, OR ARC FLASH · Apply appropriate personal protective equipment (PPE) and follow safe electrical work practices. See NFPA 70E in the USA or applicable local standards. · Th electrical personnel. · Turn off all power supplying equipment before working on or inside the equipment. · Product may use multiple voltage/power sources. Disconnect all sources of power before servicing. · Al · Do not depend on this product for voltage indication. · Current transformer secondaries must be shorted or connected to a burden at all times. · Products rated for basic insulation must be installed on insulated conductors. · Replace all doors, covers, and protective devices before powering the equipment. · In · This product is not intended for life or safety applications. Failure to follow these instructions will result in death or serious injury. WARNING RISK OF INJURY OR EQUIPMENT DAMAGE Do not apply current transducers to circuits having a phase-to-phase voltage greater than their voltage rating unless adequate additional insulation is applied between the primary conductor and the current transducers. equipment damage. Schneider Electric assumes no responsibility for damage of equipment or personal injury caused by products operated on circuits above their published ratings. © 2021 Schneider Electric All Rights Reserved. iii PowerLogic HDPM6000 Series CT Models for 75A and 125A Split and Solid Core Introduction Ordering Information Split-Core Schneider Electric PowerLogic HDPM6000S and Solid-Core Current Transducers (CTs) provide secondary voltage AC proportional to the primary (sensed) current. For use with the HDPM6000 platform only, these CTs provide a means to transform electrical service amperages to a voltage compatible with monitoring equipment. Split-core models are available with 75A voltage ratings and solid-core models with 125A voltage ratings. Part Number METSEHDPM75A12 METSEHDPM75A30 METSEHDPM75A60 METSEHDPM75A4 METSEHDPM75A16 Description 75A, SCCT, 12' lead 75A, SCCT, 30' lead 75A, SCCT, 60' lead 75A, SCCT, HDPM6000S, 4" lead 75A, SCCT, HDPM6000B, 16" lead Weight (lbs.) 0.35 0.71 1.31 0.13 0.14 Solid-Core Specifications Split-Core Part Number METSEHDPM125A12 METSEHDPM125A30 METSEHDPM125A4 METSEHDPM125A10 METSEHDPM125A16 Description 125A, SC, 12' lead 125A, SC, 30' lead 125A, SC, 4" lead, HDPM6000S 125A, SC, 10" lead, HDPM6000S 125A, SC, 16" lead, HDPM6000B Weight (lbs.) 0.35 0.71 0.13 0.13 0.14 Type Output at Rated Current Accuracy Frequency Range Leads Max. Voltage L-N Sensed Conductor Continuous Current Rating Factor Insulation class Operating Temperature Range Storage Temperature Range Humidity Range Altitude of Operation Installation Category Agency Approvals Description 0.25 VAC 1% 50/60 Hz Black and white twisted pair, 18 AWG, AWM, UL1015, 600V, 105 °C 600 VAC 1 Class 105(A) -40 to 55 °C (-40 to 131 °F) -50 to 60 °C (-58 to 140 °F) 0 to 95% non-condensing 2000 m max. Cat III, Pollution Degree 2 IEEE C57.13 CAN/CSA-C61869-1:14, CAN/CSA-C61869-2:14 CE i © 2021 Schneider Electric All Rights Reserved. Specifications (cont.) Solid-Core Dimensions Split-Core PowerLogic HDPM6000 Series CT Models for 75A and 125A Split and Solid Core Type Output at Rated Current Accuracy Frequency Range Leads Max. Voltage L-N Sensed Conductor Continuous Current Rating Factor Insulation class Operating Temperature Range Storage Temperature Range Humidity Range Altitude of Operation Installation Category Agency Approvals Description 0.25 VAC 0.1% 50/60 Hz Black and white twisted pair, 18 AWG, AWM, UL1015, 600V, 105°C 600 VAC 1 Class 105(A) -40 to 85°C (-40 to 185°F) -50 to 105°C (-58 to 221°F) 0 to 95% non-condensing 1000 m max. Cat III, Pollution Degree 2 UL2808 CE Solid-Core © 2021 Schneider Electric All Rights Reserved. 1 PowerLogic HDPM6000 Series CT Models for 75A and 125A Split and Solid Core Installation Installation must be performed by a qualified electrician. Turn off and lock out power to the primary circuit before installing these CTs. Use a properly rated voltage sensing device to confirm that power is off. NOTICE INCORRECT POLARITY Align CT arrow to point in the direction of the power flow. Failure to follow this instruction can result in incorrect readings. Solid-Core Models 1. Turn off and lock out power to the primary circuit before installing CT. 2. Use a properly rated voltage sensing device to confirm that power is off. 3. Connect the transducer output leads to the meter inputs. Reference the wiring diagram from the installation guide for the appropriate module for details. 4. Route the primary conductor through the center of the CT and complete the conductor connections. A label on the product indicates the source side. All solid-core CT models should be oriented such that the wire leads face the source: 5. Reconnect power to the panel. 2 © 2021 Schneider Electric All Rights Reserved. Installation (cont.) PowerLogic HDPM6000 Series CT Models for 75A and 125A Split and Solid Core Split-Core Models 1. Turn off and lock out power to the primary circuit before installing CT. 2. Use a properly rated voltage sensing device to confirm that power is off 3. Connect the transducer output leads to the meter inputs. The white wire is the x1 lead. 4. Release the clasp on one side of the CT and open it on the hinge. Check the core ends on both sections of the CT to ensure there is no rust or debris in the closure areas. 5. Wrap the CT around the primary lead. A label on the product indicates the source side. In the diagram below, the arrow indicates the current flow (i.e., the label faces away from the circuit breaker). Current Flow Circuit Breaker Load CTs may be simply hung on the wire on which they snap around. An alternative is the use of VELCRO® strips on the bottom or hinged side of the unit, to allow for ease of mounting and removal as necessary. VELCRO is non-conductive. 6. Close the CT until the clasp clicks into place to ensure that the contact surfaces are firmly seated. 7. Reconnect power to the panel. © 2021 Schneider Electric All Rights Reserved. 3 Schneider Electric 12345 SW Leveton Drive Tualatin, OR 97062 USA +1-503-598-4564 schneider-electric.com Schneider Electric Limited Stafford Park 5 Telford TF3 3BL United Kingdom © 2021 Schneider Electric. All Rights Reserved. PowerLogic and Schneider Electric are trademarks or registered trademarks of Schneider Electric in France, the USA and other countries. Other companies' trademarks are the property of their respective owners. As standards, specifications, and designs change from time to time, please ask for confirmation of the information given in this publication. Z208150-0C 08/2021