Ethernet Switch

Quick start Guide

1. Description

The products described in this manual, including but not limited to the products shown, please refer to the actual product purchased. If there are any changes in the appearance of the product and the packing list, please refer to the official product information.

2. Packing list

3. Switch Installation

The switch supports a variety of installation methods: desktop, rack mount. Please install according to the actual environmental requirements.

Rack type switch installation instructions:

  1. Place the device in the cabinet.
  2. Align the lugs on each end of the device with the hole bars.
  3. Screw mounting.

Rack mounting, as shown in the following figure:

[Diagram showing rack mounting with labels: Front Hole bar, Front hanger, Front panel, Fixed screw, 19in]

Please pay attention to the direction of the switch during installation.

Desktop type switch installation instruction:

The switch can be placed directly on a smooth, flat, and secure desktop. Ensure that the working environment has enough space for ventilation and heat dissipation. The following two points should be noted:

  1. Ensure that the physical surface of the switch can withstand a weight of 3 kg or more.
  2. Ensure that there is a space distance of 3cm ~ 5cm around the switch, and prohibit heavy objects from being placed on the switch.

Wall Mounting Instructions:

  1. Fix the screws on the wall.
  2. Place the wall mounting holes on the unit against the screws.

[Diagram showing wall mounting preparation with two screw holes and a device with corresponding mounting holes]

4. Device Connecting

Network Cable

  1. When the RJ45 port is 100M rate, use Cat5 and above network cable.
  2. When the RJ45 port is 1000M rate, use Cat5E and above network cable.
  3. When the RJ45 port is 2.5G rate, use Cat5E and above network cable.
  4. When the RJ45 port is 5G rate, use Cat5E and above network cable.
  5. When the RJ45 port is 10G rate, use Cat6A and above network cable.

Optical Fiber

  1. Fiber must be used with optical modules.
  2. The bending radius of the optical fiber cannot be less than 40mm.

Power Cable

  1. The distance between the power cord and the network cable should be more than 10cm.
  2. Please use AC power cord for AC power supply.

5. Login management

This content applies only to the network management type of product. Please read this help information for first-time application.

Web Management

  1. Connect the device and the PC to ensure that the device initialization is complete.
  2. Configure the PC's IP address to be on the same network segment as the switch's default IP address.
  3. Enter address "http://192.168.1.168" in PC browser. For Light Management Switch, the address is http://192.168.1.1. Press "Enter" to go to the Web management login page. Input the default user name "admin" and password "admin", then press "Enter".

Console Port Management

  1. Use the console cable to connect the PC to the console port of the switch.
  2. Open the terminal emulation software, establish a connection, select the serial port, and set the communication parameters according to the default configuration of the console port of the switch, as follows:

6. PoE Function

※ This feature is applicable to PoE switches and not to non-PoE switches.

Standard PoE power supply

[Diagram showing a PoE Switch connected to a device via a cable, with the cable's pins labeled for power and data, leading to a PoE-Camera]

Standard PoE power supply includes: Protocol detection, Power pin sequence detection, Power output, Abnormal protection, Link abnormal monitoring.

PoE power protocol includes: IEEE802.3af (15.4W), IEEE802.3at (30W), IEEE802.3bt (60W-90W).

The standard PoE power supply pin is 1,2+/3,6-. Standard PoE++ power supply pin is 1,2,4,5+/3,6,7,8-. Standard PoE switches automatically detect and power standard-compliant PoE devices; non-PoE devices do not power up and only transmit data.

7. Indicator Definition

Marks Definition Status Description
PWR Power Indicator Light on/Light off Power on/ Abnormal
SYS/NMS System indicator Light on/ Light off Whether the system work
AI POE AI PoE indicator Light on/ Light off AI PoE activated/not activated
100M Copper portConnection Status Indicator Left Indicator Speed Light on 100M connected
Light off 10M connected
Right Indicator Link/act Light stay on Port connected
Light off Port not connected
Light flash Port is connected and sending/receiving data
1000M Copper portConnection Status Indicator Left Indicator Speed Light on 1000M connected
Light off 10/100M connected
Right Indicator Link/act Light stay on Port connected
Light off Port not connected
Light flash Port is connected and sending/receiving data
2.5G Copper port Connection Status Indicator Left Indicator Speed Yellow light on 2.5G connected
Green light on 1G connected
Right Indicator Link/act Light flash Port is connected and sending/receiving data
Yellow light on 100M connected
Green light on 10M connected
2.5G Copper port Connection Status Indicator Right Indicator Link/act Light off Port not connected
10G Copper port Connection Status Indicator Left Indicator Speed Yellow light on 10G connected
Green light on 5G connected
Right Indicator Link/act Light flash Port is connected and sending/receiving data
Optical port connection status indicator Link/act Yellow light on 2.5G connected
Green light on 1G connected
Light off Port not connected
Light on Port connected
Light off Port not connected

8. DIP Switches Definition

Type of DIP Switches Definition Description
POE AI POE Auto detect and reboot the unresponsive PoE devices for recovery
Extend 250m long distance transmission (PoE port)
Port Isolation Port isolation
Storm Control Suppresses broadcast data
No-POE Reserve Reserve
Extend 250m long distance transmission (PoE port)
Port Isolation Port isolation
Storm Control Suppresses broadcast data
Light Managment Web-manage Web management
Standard Standard mode
Port Control Port isolation
AI PoE Off Off
On On

After-sales Service Letter of Commitment

Within thirty days from the date of sale, if the whole device fails, you can choose to repair, replace or return it.

If performance failure occurs within thirty days to one year from the date of sale (based on the date of purchase invoice and proof of three guarantees (repair, replacement, refund)), the whole machine can be selected for repair or replacement.

Beyond the one-year hardware warranty period, the cost of replacing the hardware will be borne by the user, and the company will not add other costs.

Other service commitments

Provide 7 × 24 hour after-sales support services.

The following are not warranted

Failure or damage to the device (including parts) is not covered by the warranty in the following cases:

  1. Accessories supplied by other companies (e.g., power supplies, adapters, etc.) are guaranteed by the manufacturer of the product.
  2. The whole device and parts are out of warranty.
  3. Failure of or damage to the device was not caused by repair, remodeling or removal by the company's personnel.
  4. Failure or damage caused by accidental or human causes, including improper operation, scratches, improper handling, improper movement, improper knocking, improper voltage input, etc.
  5. Failure or damage caused by the use of non-genuine or unreleased software.
  6. Failures or losses caused by natural disasters such as force majeure (earthquakes, fires, etc.).

Warranty Card

User Name
User Address
Post code
Contact address
Contact person
Tel
E-mail
Product model number
Serial Number
Date of purchase
Models: S200-8G 54 Port PoE Gigabit Ethernet Switch, S200-8G, 54 Port PoE Gigabit Ethernet Switch, Gigabit Ethernet Switch, Ethernet Switch

File Info : application/pdf, 13 Pages, 1.64MB

PDF preview unavailable. Download the PDF instead.

A1mTkXE4WML

References

Adobe PDF library 15.00 Adobe Illustrator 25.0 (Windows)