AprilAire S86N MU / S86N MUPR Owner's Manual

Multi-Stage Universal Thermostat

Multi-Stage Universal Thermostat with IAQ

READ AND SAVE THESE INSTRUCTIONS

About Your New Thermostat

Thermostat Features

Key Features

Quick Reference to Controls & Display

Home Screen

The Home Screen shows the current mode (e.g., HEATING), room temperature (e.g., 70°F), temperature setting (e.g., 72°F), and hold status (e.g., HOLD 5:00 PM).

Controls include: [Up Arrow] ⬆️, [Down Arrow] ⬇️, [BACK], [SELECT] (opens menu from Home Screen).

Main Menu

The Main Menu provides access to various functions. Items available depend on installed options and thermostat model.

Screen Saver

The screen saver activates 45 seconds after inactivity. Press any button to wake the screen.

The screen saver display shows the current time, room temperature, indoor humidity (RH%), and outdoor temperature.

Operation

Select System Mode (Em Heat / Heat / Cool / Auto / Off)

1. Press [SELECT] to enter the Main Menu.

2. Use [⬆️] or [⬇️] to select the 'Mode' option.

3. Press [SELECT] to enter the Mode menu.

4. Use [⬆️] or [⬇️] to select the desired mode:

5. Press [SELECT] to save the mode and return to the home screen, or [BACK] to exit without saving.

Change Temperature Setting

1. From the Home screen, press [⬆️] or [⬇️] to adjust the current temperature setting.

2. The temperature setting will enlarge during adjustment.

3. The temperature setting takes effect 3 seconds after the last adjustment, or press [SELECT] to save and return to the home screen.

Refer to 'How to Modify Program Schedules' on pages 23-24 for more information.

Select Fan Setting (Auto / On / Circulate)

When the fan mode is changed during a program event, it remains in that mode until the next event starts. The fan must be programmed to 'Fan On' in the schedule to run continuously through all events.

1. Press [SELECT] to enter the Main Menu.

2. Use [⬆️] or [⬇️] to select the 'Fan' option.

3. Press [SELECT] to enter the Fan menu.

4. Use [⬆️] or [⬇️] to select the desired fan mode:

5. Press [SELECT] to save the fan mode and return to the home screen, or [BACK] to exit without saving.

Maintenance Reminders and Lockout

Maintenance Reminders

Reminders are set by the installer for equipment service. Call your HVAC dealer if a reminder is displayed. Reminders can be reset via the 'Reset' option in the Settings menu.

Lockout

This feature disables thermostat access. It can be overridden by pressing and holding the [SELECT] button for 7 seconds.

Indoor Air Quality Functions

Event-Based™ Air Cleaning (If Installed)

This function activates the fan for air cleaning. It offers temporary events and persistent modes.

Events (Temporary)

Modes (Persistent)

Note: The thermostat manages fan and air cleaning selections when they overlap.

Humidifier Control (S86N MUPR Only, If Installed)

The thermostat can control a humidifier in either Automatic or Manual mode, based on installer setup. Automatic mode adjusts humidity based on outdoor temperature to prevent window condensation. Manual mode allows setting a specific humidity level.

Automatic Mode

In Automatic Mode, the thermostat aims to provide optimal humidity, protecting your home and furnishings. It automatically adjusts home humidity based on outdoor temperature to maximize humidity while preventing window condensation.

Initial Setup: Adjust the humidity setting to '3' (low-normal range). Monitor over 24-48 hours and adjust as needed for comfort and home construction. Minor adjustments may be necessary during the first heating season based on window insulation and overall home insulation.

Manual Mode

In Manual Mode, it's important to anticipate temperature changes. Use Table 1 to determine the proper relative humidity setting. Adjustments may be needed throughout the heating season.

Table 1 – Recommended Relative Humidity
Outdoor Temperature Indoor Relative Humidity
+50°F 50%
+40°F 45%
+30°F 40%
+20°F 35%
+10°F 30%
0°F 25%
-10°F 20%
-20°F 15%

Dehumidifier Control (S86N MUPR Only, If Installed)

This thermostat can control a whole-home dehumidifier or the air conditioner (cooling unit) for dehumidification. You can set the desired humidity level (% relative humidity) and turn dehumidification On or Off.

Initial Setup: Set the dehumidification setpoint to 60% when first installed. Allow it to run until the setpoint is reached before adjusting. Raising the setting makes the air less dry (reduces run time); lowering it makes the air more dry (increases run time).

Note on Initial Run: It's common for dehumidification to run for an extended period initially as it removes moisture from home materials.

If Dehumidification is Done with the Air Conditioner

The thermostat will cool up to 3°F beyond the cooling setpoint for dehumidification. Note: Overcooling may not always be sufficient to meet the dehumidification setpoint.

Energy Saving Tips:

Fresh Air Ventilation (S86N MUPR Only, If Installed)

This thermostat can control fresh air ventilation based on a schedule. You can temporarily override the schedule or turn it off if outdoor conditions are poor.

Events (Temporary)

Mode (Persistent)

Program Schedule and Holds

Set Time and Date

1. Select 'Settings' from the Main Menu.

2. From the Settings menu, select 'Clock' to set the time or 'Date' to set the date.

Understanding Program Schedules

The daily schedule is divided into four sections:

Table 2 shows default times and temperatures. These can be changed to fit your schedule and can help reduce heating/cooling expenses. The fan program defaults to 'Auto' for all events.

Table 2 - Default Schedule
Event Designator Start Time Set Temperature (Heat) Set Temperature (Cool) Fan
Wake 6:00 AM 70°F (21°C) 78°F (25.5°C) Auto
Leave 8:00 AM 62°F (16.5°C) 85°F (29.5°C) Auto
Return 5:00 PM 70°F (21°C) 78°F (25.5°C) Auto
Sleep 10:00 PM 62°F (16.5°C) 82°F (27.5°C) Auto

Progressive Recovery

This feature allows pre-heating or pre-cooling before a scheduled event to reach the desired temperature by the event's start time. For example, if the Wake time is 6:00 AM with a 70°F heat set point, the heat will turn on before 6:00 AM to ensure the temperature is 70°F by then.

How to Modify Program Schedules

1. From the 'Schedule' option in the Main Menu, you can turn the schedule On or Off and make changes.

2. Select 'Modify' to change default schedule settings.

3. Select the group of days or the specific day you wish to modify.

4. Adjust Wake details (Start Time, Heat, Cool, Fan) and select 'Next' to proceed.

5. Adjust Leave details and select 'Next'.

6. Adjust Return details and select 'Next'.

7. Adjust Sleep details and select 'Next'.

8. After modifying a group of days, you can 'Save & Exit' back to the Home screen. If you modified a single day, you can copy the settings to another day or group of days.

9. Confirm copies using the provided options, then return to the Modify menu by selecting 'Edit More Days' or return to the Home screen by selecting 'Save and Exit'.

Heat Blast® (If Installed)

Heat Blast® raises the room temperature by 3°F to 5°F (based on installer settings) before resuming normal operation. To activate, select 'Heat Blast' from the Menu and set the toggle to ON. This feature is only available if enabled in Installer Setup and the thermostat is in Heat or Emergency Heat mode. To cancel, select 'Heat Blast' from the Menu and set the toggle to OFF.

Program Schedule Holds

Temporary Hold

Press [⬆️] or [⬇️] to immediately adjust the temperature. This temporarily holds the setting until the next scheduled event. A temporary hold can also be set from the 'Hold' option in the Menu, where the end time can be adjusted. The hold can be canceled from the 'Hold' option in the Menu or by adjusting the temperature back to the scheduled setting.

Vacation

This energy-saving feature suspends the programmed schedule for an extended period. The selected temperature and dehumidification setpoint (if applicable) are maintained until the vacation hold end date and time. The programmed schedule resumes automatically. If you return early, turn off the Vacation hold via the 'Vacation' option in the Menu.

Setup Menu

Table 3 - User System Settings
Setting Description
Clock Set time.
Date Set date.
Display Display can be disabled during sleep for light-sensitive locations.
Scale Change temperature scale from Fahrenheit to Celsius.
About Contains thermostat model number and software/hardware version.
Reset Reminder Reset expired service reminders.
Lockout Locks controls to prevent tampering. To temporarily override, press and hold the [SELECT] button for 7 seconds.

Limited Warranty

Your Research Products Corporation AprilAire® Thermostat is warranted for five (5) years from the date of installation against defects in materials or workmanship. Research Products Corporation will supply a replacement for any defective thermostat returned within the five-year period, along with the installation date, no later than thirty (30) days after the five-year period ends, to your original supplier or to Research Products Corporation, Madison, Wisconsin 53701.

This warranty does not cover labor costs or defects in workmanship or materials furnished by your installer. Implied warranties of merchantability or fitness for a particular purpose are limited to the five-year period. Research Products Corporation is not liable for incidental or consequential damages, except for personal injuries, resulting from any breach of implied or express warranties.

This limited warranty is void if the thermostat is not installed by a qualified heating and air conditioning contractor. If voided due to improper installation, all disclaimers of implied warranties become effective.

Some states may have limitations on implied warranty duration or consequential damages, so these exclusions may not apply to you. This warranty grants specific legal rights, and you may have other rights that vary by state.

Warranty Registration

Register your AprilAire product online at www.aprilaire.com. If online access is unavailable, mail a postcard with your name, address, phone number, email address, product purchased, model number, date of purchase, and dealer name/address to: Research Products Corporation, P.O. Box 1467, Madison, WI 53701. Your warranty registration information will not be sold or shared.

Model Information: B2208832B • 61001883 • 1.22

© 2022 AprilAire | aprilaire.com | 800.334.6011

U.S. Patent Numbers: 8,146,376, 8,596,078, 9,874,366 and other patents pending.

AprilAire reserves the right to change specifications without notice.

Models: S86N MU, S86N MUPR, S86N MU Multi Stage Universal Thermostat, S86N MU, Multi Stage Universal Thermostat, Stage Universal Thermostat, Universal Thermostat

File Info : application/pdf, 15 Pages, 1.23MB

PDF preview unavailable. Download the PDF instead.

Aprilaire S86 thermostat Owners Manual

References

Adobe PDF Library 16.0.5

Related Documents

Preview AprilAire S84N Thermostat Owner's Manual
Comprehensive owner's manual for the AprilAire S84N 1H1C and S84N SU thermostats, detailing features, operation, programming, and maintenance.
Preview Aprilaire 8400 Series Thermostats: Features and Comparisons
Explore the full-featured, contractor-exclusive Aprilaire 8400 Series thermostats. Compare models 8463, 8465, 8466, and 8476 with key features like large backlit displays, dual power, 5-year warranties, and advanced IAQ circulation modes. Includes a detailed product comparison table.
Preview AprilAire S86WMUPR Wi-Fi Thermostat Installation Guide
This guide provides step-by-step instructions for installing and configuring the AprilAire S86WMUPR Wi-Fi Thermostat, including wiring, dehumidifier setup, and Wi-Fi control configuration.
Preview Aprilaire Model 8145 and 8145NC Fresh Air Ventilator Installation and Operating Instructions
This document provides comprehensive installation and operating instructions for the Aprilaire Model 8145 and 8145NC Fresh Air Ventilators. Learn about safety precautions, specifications, installation steps, wiring diagrams, operation modes, and maintenance.
Preview AprilAire Series 720 Fan-Powered Evaporative Humidifier Installation Guide
Comprehensive installation guide for the AprilAire Series 720 Fan-Powered Evaporative Humidifier, covering location, configuration, mounting, water supply, and electrical connections.
Preview AprilAire Z101DT Wireless Indoor Temperature and Humidity Sensor Installation and Operator's Manual
This manual provides installation and operational instructions for the AprilAire Z101DT Wireless Indoor Temperature and Humidity Sensor. It covers battery replacement, mounting guidelines, pairing with the S8610UPR thermostat, troubleshooting, and warranty information.
Preview Aprilaire Model 8024 24-Volt Relay Card Technical Specifications and Wiring
Detailed specifications and wiring diagram for the Aprilaire Model 8024 24-Volt Relay Card, a versatile three-relay switching device for HVAC systems, including application notes for hydronic and forced air configurations.
Preview Aprilaire E130 Dehumidifier Owner's Manual
Comprehensive guide to operating and maintaining the Aprilaire E130 Whole Home Dehumidifier, including setup, energy-saving tips, troubleshooting, and warranty information.