Instruction Manual for HILTI models including: CP 674 Fire cavity barrier non-ventilated - Preformed joints, CP 674, Fire cavity barrier non-ventilated - Preformed joints, cavity barrier non-ventilated - Preformed joints, barrier non-ventilated - Preformed joints, Preformed joints, joints

en zoeken in technische bibliotheek - Hilti België

FIRESTOP CAVITY BARRIER CP 674 - Hilti

Firestop Cavity Barrier CP 10/21 3 INSTRUCTIONS FOR USE: VENTILATED CAVITY BARRIER INSTRUCTIONS FOR USE: NON-VENTILATED CAVITY BARRIER Cn Before handling and for specific application details, refer to Hilti product literature, 3rd party published listings and national approvals. For industrial use only


File Info : application/pdf, 10 Pages, 1.33MB

PDF preview unavailable. Download the PDF instead.

Product-Guide-CP-674-2019-en- ation-ASSET-DOC-13630110
FIRESTOP CAVITY BARRIER CP 674
Product Information

Firestop Cavity Barrier CP 674

VENTILATED FIRESTOP CAVITY BARRIER CP 674 V

Areas of application
· Pre-formed intumescent fire cavity barrier for ventilated façades
Advantages
· Faster, easier installation ­ cavity barriers arrive on-site ready to fasten in place using the included stainless-steel brackets
· Verified fire resistance ­ tested according to Association for Specialist Fire Protection (ASFP) TGD 19 & BS 476-20
· Extensive range ­ barriers and brackets available f or most common cavity widths
· Design support available ­ contact your local Hilti Building Envelope Specialists for advice on complex passive fire protection detailing

Technical Data

Approvals Base Materials
Intumescent Length Storage and Transport Temp Shelf life Max Width available (E/I) TGD19 (Pr EN 1364-6) (E/I) BS476- 20

BS 476-20, TGD-19 Concrete, Masonry, Brick, SFS frame Yes 1 meter ­10 °C to 40 °C no restriction 400 mm 60/30 90/60

* For detailed approval information, please contact Hilti representative

Product Options
Product Name
CP 674 V 100-25 CP 674 V 150-25 CP 674 V 200-25 CP 674 V 250-25 CP 674 V 300-25 CP 674 V 400-25

Panel Gap Size
100 150 200 250 300 400

Item Number
2312926 2312927 2312928 2312929 2313190 2313191

NON-VENTILATED FIRESTOP CAVITY BARRIER CP 674 NV

Areas of application
· Pre-formed intumescent fire cavity barrier for ventilated and non-ventilated façades
Advantages
· Faster, easier installation ­ cavity barriers arrive on-site ready to fasten in place using the included stainless-steel brackets
· Verified fire resistance ­ tested according to Association for Specialist Fire Protection (ASFP) TGD 19 & BS 476-20
· High tolerance ­ compressible foam strip simplifies correct installation despite building tolerances
· Extensive range ­ barriers and brackets available for most common cavity widths
· Design support available ­ contact your local Hilti Building Envelope Specialists for advice on complex passive fire protection detailing

Technical Data

Approvals Base Materials
Intumescent Length Storage and Transport Temp Shelf life Max Width available E/I) TGD19 (Pr EN 1364-6) (E/I) BS476-20

BS 476-20, TGD-19 Concrete, Masonry, Brick, SFS frame Yes 1 meter ­10 °C to 40 °C no restriction 400 mm 60/30 120/120

* For detailed approval information, please contact Hilti representative

Product Options

Product Name
CP 674 NV 100 CP 674 NV 150 CP 674 NV 200 CP 674 NV 250 CP 674 NV 300 CP 674 NV 400

Panel Gap Size
100 150 200 250 300 400

Item Number
2313192 2313193 2313194 2313195 2313196 2313197

Cavity barriers pre-cut to your project requirements are available ­ please contact your Hilti representative for more information

10/21

2

Firestop Cavity Barrier CP 674

INSTRUCTIONS FOR USE: VENTILATED CAVITY BARRIER

CP 674 V

A

CP 674 V

3×

CP 674 Bracket
3A



700 mm

www.hilti.group

Cn Before handling and for specific application details, refer to Hilti product literature, 3rd party published listings and national approvals. For industrial use only Fr Avant toute utilization et pour tout detail concernant une application, référer à la documentation Hilti, à la liste de publications des tierces parties et aux
approbations nationales. Seulement pour utilisateurs professionnels. Es Antes de usar y para detalles específicos de aplicación, véase la información que acompaña al producto Hilti, el listado publicado por terceros y las
aprobaciones nacionales. Solamente para los usuarios profesionales.

CP 674 V

B <55mm

1 AB

 175 mm  350 mm

2A

<700 mm

2×  350 mm
 175 mm

CP 674 Bracket

1030mm

1030mm

4A

5A

6A

7A

2B

INSTRUCTIONS FOR USE: NON-VENTILATED CAVITY BARRIER CP 674 NV



www.hilti.group

Cn Before handling and for specific application details, refer to Hilti product literature, 3rd party published listings and national approvals. For industrial use only Fr Avant toute utilization et pour tout detail concernant une application, référer à la documentation Hilti, à la liste de publications des tierces parties et aux
approbations nationales. Seulement pour utilisateurs professionnels. Es Antes de usar y para detalles específicos de aplicación, véase la información que acompaña al producto Hilti, el listado publicado por terceros y las
aprobaciones nacionales. Solamente para los usuarios profesionales.

AB

CP 674 NV

C

< 90 mm 1 A B

3/4

2 AB

 230 mm  560 mm

 230 mm

CP 674 Bracket 3A

4A

5A

6A

7A

3B

4B  230 mm
 560 mm  230 mm

10/21

5B

6B

1C

 230 mm  560 mm  230 mm

3

Firestop Cavity Barrier CP 674

FIXING COMPONENTS FOR BASE MATERIAL

Substrate

Hilti Screw anchor: HUS HR6

Hilti Nail Anchor: HFB-R-6

Masonry Wall

X

Concrete

X

X

For Panel gap size < 80mm, use Hilti Frame anchor HRD-HR 10x140 as shown in the instrcution of use

Hilti Expansion anchor: HST3 R M6
X

APPLICATIONS

Joint Type
Base Material Joint / cavity width (min-max) Approvals E/I Rating ­ CP 674 V E/I Rating ­ CP 674 NV

Joint between wall/floor and Rainscreen
Concrete, Masonry, Brick, SFS Frame 40­400 mm TGD19 (Pr EN 1364-6) & BS 476-20 60/30 - TGD19 (Pr EN 1364-6) & 90/60 (BS476- 20) 60/30 - TGD19 (Pr EN 1364-6) & 120/120 (BS476- 20)

10/21

4

Firestop Cavity Barrier CP 674 Exterior Corners: Should have a continuous strip of intumescent barrier on leading edge

Fit CP 674 to extend past the corner by the width of the CP 674 barrier. Remove section of mineral wool from CP 674 back to corner leaving intumescent strip.

Coat back of intumescent facing strip with CP 606/CFS-S ACR. Take section of CP 674 barrier for other wall face and position end to the intumescent strip from previous step.

Fix barrier to substrate

Butt barriers together

Ensure barrier alignment/flush surfaces

Butt Joints: Cavity Barriers must tightly abut one another

Can be installed NonVentilated first and then Ventilated, or vice-versa

Space Constraints: Brackets installed below the barrier need to be protected
Where access constraints mean brackets cannot be fixed above the cavity barrier, the brackets may be fixed beneath the barrier, with 50 mm CP 670 (coated board) used to protect brackets.

10/21

PP
Notice: The product's foil cover is used for branding purposes only. Therefore, wrinkles or local detachments do not influence the product's functionality.
5

Test Report Reference: Report: NC11653 Test Date: 2nd December 2020

Scope of Report
This summary sheet covers 4 specimens; of which: 2 specimens are non-ventilated vertically installed (wall mounted) and 2 specimens are ventilated `open-state' horizontally installed (floor mounted) barriers, tested utilising the general principles of BS476: Part 20 (1987).

Table 1 ­ Tested Cavity Barriers

Specimen

Orientation Substrates

Cavity Width Seal details

Hilti CP 674NV 400, installed by compression

and 2 Nr stainless-steel brackets.

A

Vertical, Wall

AAC to AAC

400 mm

5 layers of 50 mm thick mineral fibre insulation

(50 kg/m³) fixed back to inner wall with steel

screws (abutting cavity barrier).

Hilti CP 674NV 200, installed by compression

and 2 Nr stainless-steel brackets.

B

Vertical, Wall

AAC to AAC

200 mm

3 layers of 50 mm thick mineral fibre insulation

(50 kg/m³) fixed back to inner wall with steel

screws (abutting cavity barrier).

Hilti CP 674V 225-25, installed by 3 Nr stainless-

steel brackets with 25 mm air gap between

C

Horizontal, Floor

AAC to AAC

225 mm

leading edge and external wall. 3 layers of 50 mm thick mineral fibre insulation

(50 kg/m³) fixed back to inner wall with steel

screws (abutting cavity barrier).

Hilti CP 674V 400-25, installed by 3 Nr stainless-

steel brackets with 25 mm air gap between

D

Horizontal, Floor

AAC to AAC

400 mm

leading edge and external wall. 5 layers of 50 mm thick mineral fibre insulation

(50 kg/m³) fixed back to inner wall with steel

screws (abutting cavity barrier).

Table 2 ­ Fire Resistance Performance Utilising the General Principles of BS476: Part 20 (1987).

Specimen

Integrity

Insulation

Closure time

Comments

A

132 minutes*

75 minutes

N/A

B

132 minutes*

132 minutes*

N/A

Due to the intended end use of Specimen C & D,

C

0 minutes

0 minutes

4:00**

the specimens were tested incorporating a

25 mm through gap along one edge, at the start

of the test. As a result, the specimens automati-

cally failed the integrity and insulation criteria of

D

0 minutes

0 minutes

2:21**

the test via penetration of a 25 mm gap gauge

upon commencement of the test.

* Test was discontinued after a period of 132 minutes. ** After 4:00 mins (specimen C) and 2:21 mins (specimen D), the specimens had sealed the gaps to the point that no gaps in excess of those permitted by the standard
were present. Therefore if assessed against the integrity and insulation (max temperature rise only) performance criteria of BS 476: Part 20: 1987, from this point, then: 111 mins integrity and 88 mins insulation (specimen C); and 105 mins integrity and 83 mins insulation (specimen D) were recorded.

For detailed approval information and guidance on field of applications, please contact Hilti representative

10/21

6

Warringtonfire Holmesfield Road Warrington Cheshire WA1 2DS United Kingdom T: +44 (0)1925 655116 W: www.warringtonfire.com

Test Report Reference: WF No. 417308 Test Date: 21st August 2019

Test Report Summary for Hilti (Gt Britain) Ltd

Scope of Report
This Test Report Summary has been prepared by Warringtonfire and is a summary of the test report referenced below. Full details of the constructions, the test procedure, and the test results are given in that report. This summary sheet covers two specimens of floor mounted `open-state' cavity barriers as previously fire tested by Warringtonfire utilising the general principles of ASFP Technical Guidance Document - TGD 19: Nov 2017 `Fire resistance tests for `Open-State' Cavity Barriers used in the external envelope or fabric of buildings in the configuration described below.

Test Report Reference WF No. 417308

Test Date 21st August 2019

Specimen

Table 1 ­ Tested `Open-State' Cavity Barriers

Orientation

Substrates

Cavity Width

Seal details

B

Horizontal, floor

AAC to AAC

C

Horizontal, floor

AAC to AAC

313 mm 318 mm

Hilti CP 674V 288, installed with a 25 mm air gap. A vertical section of Hilti CP 674NV 307-313 above
and below the barrier.
Hilti CP 674V 241-288, installed with a 25 mm air gap. A Hilti Eurofox MFT-S2S TT rail & U bracket penetrated the barrier with Hilti CFS F FX expanding firestop within the cavity of the rail.

Table 2 ­ Fire Resistance Performance Utilising the General Principles of ASFP Technical Guidance Document - TGD 19: Nov 2017

Specimen
B C

Integrity (cotton pad)
64 minutes 71 minutes

Integrity (sustained
flaming)
66 minutes 71 minutes*

Insulation
46 minutes 36 minutes

Insulation (Suspended
T/C's)
46 minutes 38 minutes

Closure time
3 minutes 3 minutes

* Test was discontinued after a period of 71 minutes.

Registered Office: Warringtonfire Testing and Certification Limited, 10 Lower Grosvenor Place, London, United Kingdom, SW1W 0EN. Reg No. 11371436

10/21

7

WF Test Report Summary WF No. 412510
Page 2 of 2

Specimen B

Table 3 ­ Brief Details of Specimens Construction
Description
Specimen B comprised of a foil faced stone wool fibre cavity barrier referenced `Hilti CP 674V 288' which had a stated density of 120 kg/m3. The barrier had overall dimensions of 1300 mm long, 288 mm wide and 75 mm thick. The barrier was installed with a butt joint which was taped with aluminium foil tape at 300 mm from one end of the barrier. The barrier incorporated a 25 mm wide by 1.5 mm thick graphite based intumescent strip which was bonded to the leading edge. The barrier was fixed to the supporting construction using four steel hangers. Above and below the joint was two vertical section of `Hilti CP 674NV 307-313' cavity barrier which incorporated a 30 mm x 30 mm section of intumescent foam strip down the length of the sections. The specimen also included a layer of 150 mm thick `RW3' stone wool insulation above and below the barrier with a stated density of 60kg/m3. The insulation was fixed to one face of the supporting construction using metal insulation fixings. The barrier was installed to provide a 25 mm air gap.

C

Specimen C comprised of a foil faced stone wool fibre cavity barrier referenced `Hilti CP 674V

241-288' which had a stated density of 120 kg/m3. The barrier had overall dimensions of 1300

mm long, 288 mm wide and 75 mm thick. The barrier was installed in two sections. The barrier

incorporated a 25 mm wide by 1.5 mm thick graphite based intumescent strip which was bonded

to the leading edge. The barrier was fixed to the supporting construction using four steel hangers.

Between the two sections of barrier was a penetrating `Hilti Eurofox MFT-S2S TT rail & U

bracket'. The bracket was fixed to the supporting construction using 4 No. Hilti HRD-H anchors.

The rail was fixed to the bracket using 8 No. S-AD 01SS screws. The barrier was installed around

the rail and bracket and sealed with Hilti Mastic CP606. The intumescent strip of the barrier was

cut and overlapped around the front of the rail to provide a continuous length of intumescent across the full length of the barrier. 60kg/m3 mineral wool was installed in the cavity between the

bracket and rail. The cavity within the rail was sealed with Hilti CFS F FX expanding firestop at the

exposed face of the barrier. The specimen also included a layer of 150 mm thick `RW3' stone wool insulation above and below the barrier with a stated density of 60kg/m3. The insulation was

fixed to one face of the supporting construction using metal insulation fixings. The barrier was

installed to provide a 25 mm air gap.

This test report summary may only be reproduced in full. Extracts or abridgements of reports shall not be published without
permission of Warringtonfire. All work and services carried out by Warringtonfire Testing and Certification Limited are subject to, and conducted in accordance with, the Standard Terms and Conditions of Warringtonfire Testing and Certification Limited, which are available at https://www.element.com/terms/terms-and-conditions or upon request.

10/21

8

Warringtonfire Holmesfield Road Warrington Cheshire WA1 2DS United Kingdom T: +44 (0)1925 655116 W: www.warringtonfire.com
This Report Summary is based upon a test report, as referenced above, prepared by Warringtonfire. Full details of the constructions the test procedure, and the test results are given in that report. The test report does not provide an endorsement by Warringtonfire, of the performance of the actual products supplied. This report summary has been compiled between Warringtonfire and Hilti (Gt Britain) Ltd. It is intended to provide a brief outline of the above referenced test report and not to replace it. Full copies of the test report may be obtained from: Hilti (Gt Britain) Ltd only
Responsible Officer D. Whittle* Technical Officer 11th December 2019
This copy has been produced from a .pdf format electronic file that has been provided by Warringtonfire to the sponsor of the report and must only be reproduced in full. Extracts or abridgements of reports must not be published without permission of Warringtonfire. The pdf copy supplied is the sole authentic version of this document. All pdf versions of this report bear authentic signatures of the responsible Warringtonfire staff.

Registered Office: Warringtonfire Testing and Certification Limited, 10 Lower Grosvenor Place, London, United Kingdom, SW1W 0EN. Reg No. 11371436

10/21

9

Hilti Corporation 9494 Schaan, Liechtenstein P +423-234 2965

www.facebook.com/hiltigroup www.hilti.group

Hilti = registered trademark of Hilti Corp., Schaan W4558 1021 0-en 2 Printed in Liechtenstein © 2021 Right of technical and programme changes reserved S. E. & O.



References

Adobe PDF Library 16.0 Adobe InDesign 16.4 (Macintosh)